首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   74篇
  免费   3篇
化学   72篇
力学   1篇
物理学   4篇
  2023年   1篇
  2021年   3篇
  2020年   3篇
  2019年   1篇
  2018年   3篇
  2017年   3篇
  2016年   10篇
  2015年   3篇
  2014年   4篇
  2013年   4篇
  2012年   4篇
  2011年   7篇
  2010年   5篇
  2009年   1篇
  2008年   2篇
  2007年   7篇
  2006年   4篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2001年   1篇
  1999年   1篇
  1995年   2篇
  1993年   2篇
  1992年   1篇
排序方式: 共有77条查询结果,搜索用时 93 毫秒
71.
In this study, a simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME) combined gas chromatography-electron capture detection (GC-ECD), for the determination of chlorobenzenes (CBs) in water samples, has been described. This method involves the use of an appropriate mixture of extraction solvent (9.5 μl chlorobenzene) and disperser solvent (0.50 ml acetone) for the formation of cloudy solution in 5.00 ml aqueous sample containing analytes. After extraction, phase separation was performed by centrifugation and the enriched analytes in sedimented phase were determined by gas chromatography-electron capture detection (GC-ECD). Our simple conditions were conducted at room temperature with no stiring and no salt addition in order to minimize sample preparation steps. Parameters such as the kind and volume of extraction solvent, the kind and volume of disperser solvent, extraction time and salt effect, were studied and optimized. The method exhibited enrichment factors and recoveries ranging from 711 to 813 and 71.1 to 81.3%, respectively, within very short extraction time. The linearity of the method ranged from 0.05 to 100 μg l−1 for dichlorobenzene isomers (DCB), 0.002-20 μg l−1 for trichlorobenzene (TCB) and tetrachlorobenzene (TeCB) isomers and from 0.001 to 4 μg l−1 for pentachlorobenzene (PeCB) and hexachlorobenzene (HCB). The limit of detection was in the low μg l−1 level, ranging between 0.0005 and 0.05 μg l−1. The relative standard deviations (R.S.D.s) for the concentration of DCB isomers, 5.00 μg l−1, TCB and TeCB isomers, 0.500 μg l−1, PeCB and HCB 0.100 μg l−1 in water by using the internal standard were in the range of 0.52-2.8% (n = 5) and without the internal standard were in the range of 4.6-6.0% (n = 5). The relative recoveries of spiked CBs at different levels of chlorobenzene isomers in tap, well and river water samples were 109-121%, 105-113% and 87-120%, respectively. It is concluded that this method can be successfully applied for the determination of CBs in tap, river and well water samples.  相似文献   
72.
A simple and useful method employing cloud point extraction is proposed for the preconcentration and separation of silver in water samples. The silver cation reacts with bis(2-mercaptoanil) acetylacetone (BMAA) at pH 6. The resulting compound is subsequently entrapped in the Triton X-114 micelles. After optimization of the complexation and extraction conditions, a preconcentration factor of 50 was obtained (volume of initial sample was 10 mL). As an analytical example, trace amounts of Ag were determined, after preconcentration, in a complex aqueous matrix such as seawater using flame atomic absorption spectrometry. The calibration curve was linear in the range 2–200 ng/mL and the limit of detection was 0.43 ng/mL. The relative standard deviation was lower than 2.4%. The text was submitted by the authors in English.  相似文献   
73.
A simple and sensitive method has been developed for species selective determination of chromium(III) and chromium(VI) in water by electrothermal atomic absorption spectrometry. The procedure is based on selective absorption of Cr(III) on a cellulose micro column (pH 11, 0.5 mol L(-1) NaCl). Total chromium was subsequently determined after appropriate reduction of Cr(VI) to Cr(III). Recoveries of more than 97% were found. A concentration factor of 100 was achieved. The relative standard deviations (n=10) at the 40 ng L(-1) level for chromium(III) and chromium(VI) were 2.3% and 1.8% and corresponding limits of detection (based on 36) were 1.8 ng L(-1) and 5.1 ng L(-1), respectively. No interference effects have been observed from other investigated species and the method has been successfully applied to natural water samples.  相似文献   
74.
In this study, a novel adsorbent from a mesoporous family (MCM-41) coating with CoFe2O4 and piperazine was synthesized by a simple and easy route. Its application for simultaneous preconcentration of three heavy metals including lead, cadmium and copper in real samples followed by a flame atomic absorption spectroscopy was investigated. The central composite design was employed for investigating the most effective factors of pH, amount of adsorbent, the equilibrium time and their interactions. Under the optimum conditions, the detection limits for lead, cadmium and copper were 0.50, 0.30 and 0.25 μg L?1, respectively, and the preconcentration factor (PF) was 33. The presented method was successfully employed for the simultaneous determination of the three mentioned heavy metals in real samples with recoveries of 90%–105%. The accuracy of the suggested methods was also investigated through spiking samples and a reasonable range for recoveries from 90.3% to 107% was acquired. The isotherm models and thermodynamic parameters have also been studied. The new adsorbent showed fast adsorption kinetics within 10 min and maximum Langmuir monolayer capacities of 238.09, 178.57 and 208.33 mg g?1 for lead, cadmium and copper, respectively.  相似文献   
75.
A new combined method including fiber optic-linear array detection spectrophotometry (FO-LADS) and cloud point extraction (CPE) was developed using a cylindrical micro cell for simultaneous preconcentration and determination of different species. The CPE and FO-LADS methods have good matching conditions for combination because FO-LADS is suitable as a detection technique for the low volume of remained phase obtained after CPE. This combination was carried out using 50 μL cylindrical micro cell and then employed for simultaneous preconcentration and determination of cobalt and nickel.Cloud point extraction method was based on the chromogenic reaction of metal ions and 1-(2-pyridylazo)-2-naphthol (PAN) and then preconcentration of formed complexes using octylphenoxypolyethoxyethanol (Triton X-114). The remained phase after CPE was transferred into cylindrical micro cell and located at the cell holder of FO-LADS. The spectra of cobalt and nickel complexes were collected by FO-LADS and processed for ordinary and first derivative spectrophotometry.Optimization of different parameters was evaluated. Under optimum conditions, calibration curves were linear in the range of 0.6-30.0 and 0.1-15.0 μg L−1 with detection limits of 0.2 and 0.04 μg L−1 for Co and Ni respectively. The relative standard deviations (R.S.D.s) were lower than 4%. The obtained enhancement factors were 198 and 199 for cobalt and nickel, respectively.The proposed method was compared with the other methods and applied to the analysis of several real and spiked samples.  相似文献   
76.
This paper introduces a design of experiments (DOE) approach for method optimisation in hydrophilic interaction chromatography (HILIC). An optimisation strategy for the separation of acetylsalicylic acid, its major impurity salicylic acid and ascorbic acid in pharmaceutical formulations by HILIC is presented, with the aid of response surface methodology (RSM) and Derringer's desirability function. A Box-Behnken experimental design was used to build the mathematical models and then to choose the significant parameters for the optimisation by simultaneously taking both resolution and retention time as the responses. The refined model had a satisfactory coefficient (R2>0.92, n=27). The four independent variables studied simultaneously were: acetonitrile content of the mobile phase, pH and concentration of buffer and column temperature each at three levels. Of these, the concentration of buffer and its cross-product with pH had a significant, positive influence on all studied responses. For the test compounds, the best separation conditions were: acetonitrile/22 mM ammonium acetate, pH 4.4 (82:18, v/v) as the mobile phase and column temperature of 28°C. The methodology also captured the interaction between variables which enabled exploration of the retention mechanism involved. It would be inferred that the retention is governed by a compromise between hydrophilic partitioning and ionic interaction. The optimised method was further validated according to the ICH guidelines with respect to linearity and range, precision, accuracy, specificity and sensitivity. The robustness of the method was also determined and confirmed by overlying counter plots of responses which were derived from the experimental design utilised for method optimisation.  相似文献   
77.
Burn is one of the physically debilitating injuries that can be potentially fatal; therefore, providing appropriate coverage in order to reduce possible mortality risk and accelerate wound healing is mandatory. In this study, collagen/exo-polysaccharide (Col/EPS 1–3%) scaffolds are synthesized from rainbow trout (Oncorhynchus mykiss) skins incorporated with Rhodotorula mucilaginosa sp. GUMS16, respectively, for promoting Grade 3 burn wound healing. Physicochemical characterizations and, consequently, biological properties of the Col/EPS scaffolds are tested. The results show that the presence of EPS does not affect the minimum porosity dimensions, while raising the EPS amount significantly reduces the maximum porosity dimensions. Thermogravimetric analysis (TGA), FTIR, and tensile property results confirm the successful incorporation of the EPS into Col scaffolds. Furthermore,the biological results show that the increasing EPS does not affect Col biodegradability and cell viability, and the use of Col/EPS 1% on rat models displays a faster healing rate. Finally, histopathological examination reveals that the Col/EPS 1% treatment accelerates wound healing, through greater re-epithelialization and dermal remodeling, more abundant fibroblast cells and Col accumulation. These findings suggest that Col/EPS 1% promotes dermal wound healing via antioxidant and anti-inflammatory activities, which can be a potential medical process in the treatment of burn wounds.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号