We report an electrospray ionisation multistage mass spectrometry (ESI-MSn) method that utilises molecular mass information for determination of sequence distribution and chemical structure of mass-selected macromolecules of poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) biopolyester, PHBH. On the basis of ESI-MSn studies of PHBH oligomers obtained by partial alkaline depolymerisation of natural PHBH containing 13-14 mol% of hydroxyhexanoate (HH) units, the microstructure of this bacterial copolyester was assessed up to the level of 28 repeat units. The subtle structural details of the PHBH were evaluated based on sequencing of individual macromolecular ions thus showing the utility of this technique for the analysis of biological copolyester macromolecules. It was confirmed that both HH and hydroxybutyrate (HB) units of the PHBH copolymer are randomly distributed. 相似文献
Recent large helical device experiments revealed that the transition from ion root to electron root occurred for the first time in neutral-beam-heated discharges, where no nonthermal electrons exist. The measured values of the radial electric field were found to be in qualitative agreement with those estimated by neoclassical theory. A clear reduction of ion thermal diffusivity was observed after the mode transition from ion root to electron root as predicted by neoclassical theory when the neoclassical ion loss is more dominant than the anomalous ion loss. 相似文献
It was observed that the vacuum magnetic island produced by an external error magnetic field in the large helical device shrank in the presence of plasma. This was evidenced by the disappearance of flat regions in the electron temperature profile obtained by Thomson scattering. This island behavior depended on the magnetic configuration in which the plasmas were produced. 相似文献
A new method to remove water adsorbed on flouride glass preforms is reported. This method, using NF3 plasma, can remove surface water on fluoride glasses 相似文献
The quantitative evaluation on measurement of liver volume and the hepatic accumulation rate of the radioactive agent were studied with respect to body constitution, background activity and splenic consumption rate, using single photon emission computed tomography (SPECT). The optical cut-off level for liver volume determination was proved to be reasonable as 35%. The background less than 5% had no influence to their clinical estimation with the error of less than 1.6%. The estimation of liver volume was mostly influenced by the splenic activity. When the splenic activity was increased two times of the hepatic activity, the liver volume was determined as 4.2% larger. Calculated counts by SPECT was well correlated with the hepatic activity. This study proved that SPECT was useful for the quantitative evaluation of the liver volume and the hepatic accumulation rate. 相似文献
In our photo‐induced immobilization technique for an antibody (IgG) using azopolymers, the introduction of COOH and NMe2 into the azopolymers, which can introduce surface charges, strongly affected the immobilization properties such as the efficiency of immobilization and the activity of the immobilized IgG (i.e., the orientation of the immobilized IgG). The introduction of COOH promoted a more active orientation of the immobilized IgG. The orientation was determined during the adsorption process onto the azopolymer surface in solution before photo‐immobilization, and was maintained during the photo‐immobilization. The surface charge of the azopolymer appears to be an important factor for IgG orientation, which involves electrostatic interactions between its Fab and the azopolymer surface.