排序方式: 共有73条查询结果,搜索用时 15 毫秒
51.
52.
53.
G. Emory Anderson 《Fiber and Integrated Optics》2002,21(5):345-359
This article discusses the evolution of Synchronous Optical Network (SONET) towards support for shared packet media, particularly in light of new developments in the control plane, such as Generalized Multiprotocol Label Switching (GMPLS) and the (UNI) specification. Whereas the current SONET network is largely static and circuitcentered, and typically supports DS-1 and DS-3-level granularities, the emerging packet-centric, GMPLS-controlled optical network will be significantly more dynamic, and characterized by concatenated or virtually concatenated payloads such as STS-3c/12c/48c/192c, and, possibly, STS-1-24v (i.e., 'STS-24c'). In this environment, it will be shown that the differences between such packet-centric SONET networks and 'IP over Optical' network architectures begin to disappear. 相似文献
54.
Clauwaert KM Van Bocxlaer JF Major HJ Claereboudt JA Lambert WE Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
55.
56.
57.
58.
59.
60.