全文获取类型
收费全文 | 60篇 |
免费 | 3篇 |
国内免费 | 1篇 |
专业分类
化学 | 46篇 |
数学 | 9篇 |
物理学 | 9篇 |
出版年
2023年 | 1篇 |
2022年 | 1篇 |
2021年 | 3篇 |
2020年 | 1篇 |
2017年 | 1篇 |
2016年 | 3篇 |
2015年 | 2篇 |
2014年 | 2篇 |
2012年 | 1篇 |
2011年 | 1篇 |
2010年 | 4篇 |
2009年 | 1篇 |
2008年 | 2篇 |
2007年 | 6篇 |
2006年 | 4篇 |
2005年 | 4篇 |
2004年 | 8篇 |
2003年 | 6篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1998年 | 1篇 |
1996年 | 1篇 |
1994年 | 2篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1981年 | 1篇 |
1977年 | 1篇 |
1976年 | 1篇 |
1973年 | 1篇 |
排序方式: 共有64条查询结果,搜索用时 15 毫秒
51.
Rosemary Castorina Marie Tysman Asa Bradman Sara Hoover Shoba Iyer Marion Russell 《International journal of environmental analytical chemistry》2016,96(13):1247-1263
There is little published research examining volatile organic compound (VOC) emissions from art markers. In this study, we characterised VOC emission rates from markers commonly used by children at home and in school, and by teachers in their classrooms. We developed a method to measure standardised emission rates under controlled laboratory conditions, focusing on four major marker types: permanent, dry erase, highlighter, and washable. Emission rates for other less common marker types were also measured. We conducted additional experiments determining changes in emission profiles over short and long time periods (several hours up to daily use over about 2 months), as well as during periods of active drawing. We tested a total of 101 markers and report emission rates for 60 chemicals. Permanent and dry erase markers had average total VOC emissions more than 400 times higher than highlighters and washable markers. Alcohols were the most highly emitted class of VOCs from permanent and dry erase markers. Some chemicals associated with potentially serious health concerns were also identified. Future studies that employ full-scale chamber experiments and personal monitoring in classrooms to measure children’s actual exposures are recommended. 相似文献
52.
Wan H Ostlund A Jönsson S Lindberg W 《Rapid communications in mass spectrometry : RCM》2005,19(12):1603-1610
A novel drug-protein binding measurement method based on high-performance frontal analysis and capillary electrophoresis (HPFA/CE) is presented. A single run measurement approach is proposed to circumvent utilization of a calibration curve that is often performed with HPFA. A sensitive mass spectrometer is applied as a detector enabling the measurement of in vitro protein binding at lower drug concentrations. Unbound free fraction and binding constants can be determined by a single run measurement by consecutive injections of an internal drug standard, a buffer plug and a drug-protein mixture. Effects of injection volumes on peak height and plateau profile were investigated in two different separation systems, non-volatile buffer and volatile buffer, with UV and mass spectrometry detection, respectively. A simplified one-to-one binding model is employed to evaluate the proposed method by using both single and multiple drug concentrations to measure the unbound free fraction and calculate the binding constants of some selected compounds. The method is suitable for rapid and direct screening of the binding of a drug to a specific protein or drug-plasma protein binding. 相似文献
53.
Saara Mikkonen Johan Jacksén Åsa Emmer 《Analytical and bioanalytical chemistry》2014,406(14):3521-3524
A new instrumental concept for extraction of nanovolumes from open microchannels (dimensions 150 μm?×?50 μm, length 10 mm) manufactured on silicon microchips has been used in combination with a previously developed method for preconcentrating proteins and peptides in the open channels through electromigration. The extracted nanovolumes were further analyzed using nanoelectrospray ionization (nESI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) directly or with subsequent enzymatic protein digestion in a nanodroplet prior to the MS analysis. Preconcentration of the samples resulted in a 15-fold sensitivity increase in nESI for a neurotensin solution, and using MALDI-MS, amyloid beta (Aβ) peptides could be detected in concentrations down to 1 nM. The method was also successfully applied for detection of cell culture Aβ. 相似文献
54.
Determination of amines in biological samples as markers of exposure to the amines or the corresponding isocyanates is an important tool for industrial exposure assessment. In this study, a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for determination of amines in biological samples as perfluorofatty amides derivatives is presented. The method enables determination of diamines such as methylene diamine (MDA), toluene diamine (TDA), naphthalene diamine (NDA), hexamethylene diamine (HDA), isophorone diamine (IPDA), methylenedi(cyclohexylamine)(HMDA) and 4,4'-methylene-(2-chloroaniline)(MOCA) in human urine and plasma. The work-up procedure included hydrolysis of the biological samples with 3 M H(2)SO(4) at 100 degrees C for 16 h and extraction of the amines into toluene, where derivatisation of the amines with perfluorofatty acid anhydride was performed. Following removal of excess reagent and the acid formed and an exchange of solvent, the derivatives were analysed using gradient elution with an acetonitrile/water mobile phase composition and electrospray ionisation (ESI) with multiple reaction monitoring (MRM) of [M - H](-)-->[M - H - 120](-) or [119](-). Several perfluorofatty acid anhydrides were evaluated as derivatisation reagents, but the LC chromatographic properties of the pentafluoropropionic acid anhydride (PFPA) derivatives were favourable. Quantification of amine-PFPA derivatives was performed using deuterium labelled amine-PFPA derivatives as internals standards with good precision and linearity in the investigated range of 0-20 ng ml(-1) urine. The instrumental detection limits for the amine-PFPA derivatives were 0.2-3 fmol for MRM of [M - H](-)-->[119](-) and 0.3-8 fmol for [M - H](-)-->[M - H - 120](-). In 10 urine and 6 plasma samples from workers exposed to isocyanates, determination of TDA and MDA as PFPA derivatives was performed using LC-MS/MS and a reference GC-MS method. No significant difference between the two methods was observed. 相似文献
55.
Determination of fluoroquinolones in bovine milk samples using a pipette‐tip SPE step based on multiwalled carbon nanotubes prior to CE separation 下载免费PDF全文
Valeria Springer Johan Jacksén Patrik Ek Adriana G. Lista Åsa Emmer 《Journal of separation science》2014,37(1-2):158-164
A simple CE–UV method was developed for the simultaneous determination of ciprofloxacin, norfloxacin, and ofloxacin in milk samples. The optimum separation was obtained using a 20 mM ammonium dihydrogenphosphate solution with 2 mM cetyltrimethylammonium bromide at pH 3.0 as the BGE. Satisfactory resolution for structurally very similar analytes, like norfloxacin and ciprofloxacin, was achieved without including any organic solvent. Milk samples were prepared using a simple/extraction procedure based on acidic protein precipitation followed by an SPE step using only 5 mg of multiwalled carbon nanotubes as the sorbent material. The LODs for the three compounds were between 7.5 and 11.6 μg/L and the RSDs for the peak areas were between 2.6 and 4.9%. The complete method was applied to spiked real milk samples with satisfactory recoveries for all analytes (84–106%). 相似文献
56.
Lindh CH Littorin M Amilon A Jönsson BA 《Rapid communications in mass spectrometry : RCM》2008,22(2):143-150
Phenoxyacetic acids are widely used herbicides. The toxicity of phenoxyacetic acids is debated, but high-level exposure has been shown to be hepatotoxic as well as nephrotoxic in animal studies. An inter-species difference in toxic effects has been found, with dogs particularly susceptible. In this study a method using liquid chromatography/triple quadrupole mass spectrometry (LC/MS/MS) is described for the analysis of 4-chloro-2-methylphenoxyacetic acid (MCPA), and its metabolite 4-chloro-2-hydroxymethylphenoxyacetic acid (HMCPA), 2,4-dichlorophenoxyacetic acid (2,4-D), and 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in human urine. The urine samples were treated by acid hydrolysis to degrade possible conjugations. The sample preparation was performed using solid-phase extraction. Analysis was carried out using selected reaction monitoring (SRM) in the negative ion mode. Quantification of the phenoxyacetic acids was performed using [(2)H(3)]-labeled MCPA and 2,4-D as internal standards. The method was linear in the range 0.05-310 ng/mL urine and has a within-run precision of 2-5%. The between-run precision in lower concentration ranges was between 6-15% and between 2-8% in higher concentration ranges. The limit of detection was determined to 0.05 ng/mL. The metabolites in urine were found to be stable during storage at -20 degrees C. To validate the phenoxyacetic acids as biomarkers of exposure, the method was applied in a human experimental oral exposure to MCPA, 2,4-D and 2,4,5-T. Two healthy volunteers received 200 microg of each phenoxyacetic acid in a single oral dose followed by urine sampling for 72 h post-exposure. After exposure, between 90 and 101% of the dose was recovered in the urine. In the female subject, 23%, and in the male subject 17%, of MCPA was excreted as HMCPA. 相似文献
57.
Carlsson A Starck G Ljungberg M Ekholm S Forssell-Aronsson E 《Magnetic resonance imaging》2006,24(9):1179-1185
Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imaging for the determination of magnetic susceptibility of materials. J Magn Reson 1996; Series B(112):111-118] was improved to facilitate sensitive in-house measurements of different phantom materials so that such artifacts can more easily be minimized. Using standard MRI protocols and distilled water as reference, we measured magnetic volume susceptibility differences with a clinical MR system. Two imaging techniques, echo planar imaging (EPI) and spin echo, were compared using liquid samples whose susceptibilities were verified by MR spectroscopy. The EPI sequence has a very narrow bandwidth in the phase-encoding direction, which gives an increased sensitivity to magnetic field inhomogeneities. All MRI measurements were evaluated in two ways: (1) manual image analysis and (2) model fitting. The narrow bandwidth of the EPI made it possible to detect very small susceptibility differences (equivalent susceptibility difference, Deltachi(e)> or =0.02 ppm), and even plastics could be measured. Model fitting yielded high accuracy and high sensitivity and was less sensitive to other image artifacts as compared with manual image analysis. 相似文献
58.
Michele Emmer Prof. 《ZDM》1998,30(3):74-77
During the Desert Storm, the Gulf war, it was possible to read in the newspapers words such as: “Inmathematical terms, was is becoming more and more electronically controlled and, as a result, it is moving away from the battlefield. Then, when war comes down to earth, it becomes bloody, it loses its mathematical asceticism” Reading the newspapers in those days, one had the impression that modern warfare is based on mathematics, as if it were not men but computers that decided where to carry out “surgical operations”. By contrast, the volume published a few years before the Gulf war conceived as a didactic unit to be used in schools with a guide for the teacher with the titleLa matematica della guerra (The Mathematics of War) published by Gruppo Abele in Turin begins with the words “Mathematics, like any other discipline, lends itself to building several paths towards education for peace”. The volume, written by a group of teachers belonging to an anti-violence organisation forming part of the “education for peace” project, highlights the power or ambiguitiy of mathematical models used to simulate war or conflict situations and demonstrates that in some cases the use of mathematics leads to a better understanding of the situation, but in other cases, the mathematical model itself can lead to conclusions which are either wrong or morally unacceptable. 相似文献
59.
A new prestructured target plate for matrix-assisted laser desorption/ionization (MALDI) was developed specifically for hydrophobic integral membrane proteins. This sample support contains predefined concentrating sample spots with a focusing effect on droplets with a high content of hexafluoroisopropanol (HFIP). This fluorinated organic solvent is advantageous for solubilizing hydrophobic proteins that are not soluble in water or the organic solvents normally used in sample preparation protocols for MALDI-MS. The prestructured plate was constructed by coating a regular steel plate with a thin layer of a silicone polymer, leaving sample spots of bare steel. Fabrication of the concentrating silicone structure was fast and very straightforward, without expensive or complicated equipment. Removing the layer, and thus regenerating the steel plate, was done by a simple washing procedure. The application and cleaning procedure are not constrained by a particular design of sample support or to any specific brand of mass spectrometer. When using the prestructured MALDI plate with HFIP as the sample solvent for 17 pmol of a cyanogen bromide digest of the highly hydrophobic membrane protein bacteriorhodopsin, an improved focusing effect and an increase of more than five-fold in average sensitivity were observed, compared with a regular steel target. Experimental results show a two-fold increase in average sensitivity when the new prestructured target plate was used, compared with a commercially available concentrating support. 相似文献
60.
We have developed an array-based resequencing method to determine genetic alterations in putative cancer genes. The method relies on that the specificity of DNA polymerase in allele-specific extensions can be enhanced by terminating the extension reactions with apyrase and that a tiling set of primers are synthesized covering the investigated gene sequence. We report on such apyrase-mediated allele-specific primer extension (AMASE) assay as a method suitable for high-throughout resequencing and mutation detection in tumor suppressor genes and oncogenes. In the experimental setup, primers complementary to codons 12, 13 and codon 61 of the N-ras proto-oncogene were spotted onto glass slides. Overlapping sense and anti-sense primers were designed so that complementary primers for all possible mutations in each base position were investigated. The extension reactions were performed in a single step following hybridization of target DNA to the immobilized primers on the array surface. Mutation detection limits and the possibility of quantifying the mutations were investigated using synthetic oligonucleotides. In addition, 64 clinical samples were sequenced and 16 of these showed mutations in the N-ras gene. 相似文献