首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   48篇
  免费   1篇
化学   42篇
数学   2篇
物理学   5篇
  2022年   1篇
  2021年   1篇
  2017年   1篇
  2016年   2篇
  2015年   1篇
  2014年   1篇
  2013年   7篇
  2012年   3篇
  2011年   3篇
  2010年   2篇
  2009年   2篇
  2008年   2篇
  2007年   3篇
  2006年   3篇
  2005年   4篇
  2004年   3篇
  2002年   1篇
  2001年   1篇
  2000年   3篇
  1999年   1篇
  1997年   1篇
  1994年   1篇
  1993年   1篇
  1974年   1篇
排序方式: 共有49条查询结果,搜索用时 15 毫秒
21.
An LC–MS–MS-based procedure for determination in hair of 14 different drugs of abuse belonging to the classes cocaine, amphetamine-like compounds, opiates, and hallucinogens has been developed. A pressurized-liquid extraction procedure was used and proved useful for quantitative recovery of all the analytes tested. This procedure, in conjunction with a simple decontamination step, performed to avoid false-positive samples, enabled the detection of all the analytes with LOQ ranging from 1.8 to 16 pg mg?1 and accuracy varying from 85 to 111 %. The procedure was validated in accordance with the SOFT/AAFS guidelines and seems to be suitable for routine determination of the drugs tested in hair.  相似文献   
22.
The ‘anomalous perihelion precession’ of Mercury, announced by Le Verrier in 1859, was a highly controversial topic for more than half a century and invoked many alternative theories until 1916, when Einstein presented his theory of general relativity as an alternative theory of gravitation and showed perihelion precession to be one of its potential manifestations. As perihelion precession was a directly derived result of the full General Theory and not just the Equivalence Principle, Einstein viewed it as the most critical test of his theory. This paper presents the computed value of the anomalous perihelion precession of Mercury's orbit using a new relativistic simulation model that employs a simple transformation factor for mass and time, proposed in an earlier paper. This computed value compares well with the prediction of general relativity and is, also, in complete agreement with the observed value within its range of uncertainty. No general relativistic equations have been used for computing the results presented in this paper.  相似文献   
23.
The essential oil from leaves of Croton gossypiifolius Vahl. (Euphorbiaceae) was obtained by hydrodistillation, and analyzed by GC/FID and GC/MS. The constituents were identified by their mass spectra and Kovats' indices. Fifty-one compounds accounting for 92% of the oil were detected, and 47 of them were identified. The oil was dominated by oxygenated sesquiterpenes with the major presence of alpha-cedrene oxide (18.6%), spathulenol (16.3%), valencene (5.8%), geranyl-pentanoate (5.3%), alpha-cadinol (4.0%), germacrene D (3.5%) and longifolene (3.3%).  相似文献   
24.
Abstract

Recent studies on the fragmentation of some organic disulfides upon electron impact in a mass spectrometer have shown two main decomposition routes besides simple bond disconnection: skeletal rearrangements1–3 and proton transfer4. Transposition of the molecular components takes place via loss of one or two sulfur atoms while the carbon skeleton is preserved. Such molecular rearrangements are particularly noticeable in small molecules like dimethyl disulfide. Larger systems show a different fragmentation pattern in which proton transfer to give alkyl hydro-disulfides becomes predominant. The transfer of protons has been shown to proceed by way of intramolecular 1,2 and 1,3 hydrogen shifts from α and β carbons respectively by means of selective deuterium labbeling of diethyl disulfide.4  相似文献   
25.
An electrochemical assay used for detecting acetylcholinesterase (AChE) inhibitors has been optimised to detect pirimiphos-methyl in durum wheat. Pirimiphos-methyl is a phosphothionate insecticide and so it needs to be transformed into the corresponding oxo form to act as an effective AChE inhibitor. The inhibition assay was based on the electrochemical detection of the product of AChE, choline, via choline oxidase biosensors obtained with Prussian-Blue modified screen printed electrodes. The procedure for the oxidation of pirimiphos methyl via N-bromosuccinimide (NBS) and AChE inhibition was optimised for reagent concentrations and inhibition time in a buffer solution. A calibration of the pirimiphos-methyl (25–1,000 ng/ml) was obtained in the buffer. The intra-electrode CV ranged between 1.6 and 15.0, whereas the inter-electrode CV ranged between 4.6 and 16.0. The detection limit (LOD) was 38 ng/ml, and the I50% was 360 ng/ml. The assay conditions were then re-optimised to work with durum wheat extracts, and the calibrations were obtained under different experimental conditions, such as sample pretreatment (milled or whole grains) and extract concentration. The calibrations were slightly affected by the sample matrix, resulting in an increased LOD (65–133 ng/ml) and I50% (640–1,650 ng/ml). The LOD found for the sample, determined under optimal conditions, was 3 mg/kg. Spiked samples were prepared at the EU regulated level (5 mg/kg) and analysed with the optimised protocol, resulting in an average recovery of 70.3%.  相似文献   
26.
Glucose oxidase/hexokinase electrode for the determination of ATP   总被引:2,自引:0,他引:2  
A hydrogen peroxide based enzyme electrode for the determination of ATP has been developed by the immobilization of glucose oxidase and hexokinase. Competition between the enzymes for the substrate glucose allowed the measurement of ATP. Different immobilization procedures and different types of hexokinase have been tested. Using a BSA-glutaraldehyde procedure and hexokinase from an overproducing strain of bakers' yeast, ATP was measured in the 0.05–0.5 mmol l−1 range with a detection limit of 0.01 mmol l−1. ATP concentrations comparable to those reported in the literature and a good recovery were obtained when the enzyme electrode was used with human erythrocyte hemolysate.  相似文献   
27.
Amperometric enzyme electrode probes have been constructed for the specific determination of L-lysine and used in batch and flow analysis. The enzyme lysine oxidase was immobilized on a preactivated polymer support which was placed on a platinum electrode. Additional blocking membranes conferred high stability, reproducibility and avoided electrochemical and enzyme interferences. Parameters including pH, temperature, storage and operational times were optimized. Lysine was determined in the range 10(-6)-2.10(-3)M with a detection limit of 5 x 10(-7)M. The Michaelis constant was 2 x 10(-3)M. This value was approximately two order of magnitudes higher than that reported in literature for the free enzyme. The response time of the probe was about 2 min in batch and flow analysis and 30 sec in flow injection analysis (FIA). The resulting probes were stable for more than three months with more than 300 analyses performed. The determination of lysine was carried out by both flow-through analysis and FIA. Analysis in feeds was carried out by acid hydrolysis to liberate lysine; then the solution was analyzed by the bioprobe and HPLC procedures. Results by the two methods correlated well.  相似文献   
28.
A confirmatory method for the determination of illicit drugs based on micro-solid phase extraction with modified tips, made of a functionalized fiberglass with apolar chains of octadecylsilane into monolithic structure, has been developed in this study. Drugs belonging to different chemical classes, such as amphetamine, methamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethylamphetamine, cocaine, benzoylecgonine, ketamine, mescaline, phencyclidine and psilocybine were analyzed. The quantitation was performed by liquid chromatography-tandem mass spectrometry and the analytes were detected in positive ionization by means of an electrospray source. The limits of quantification ranged between 0.3 ng mL−1 for cocaine and 4.9 ng mL−1 for psilocybine, with coefficients of determination (r2) >0.99 for all the analytes as recommended in the guidelines of Society of Forensic Toxicologists-American Association Forensic Sciences.  相似文献   
29.
Carbon black nanoparticle (CBNP) press‐transferred film‐based transducers for the molecular detection at the microscale level were proposed for the first time. Current‐sensing atomic force microscopy (CS‐AFM) revealed that the CBNP films were effectively press‐transferred, retaining their good conductivity. A significant correlation between the morphology and the resistance was observed. The highest resistance was localized at the top of the press‐transferred film protrusions, whereas low values are usually obtained at the deep crevices or grooves. The amount of press‐transferred CBNPs is the key parameter to obtain films with improved conductivity, which is in good agreement with the electrochemical response. In addition, the conductivity of such optimum films was not only Ohmic; in fact, tunneling/hopping contributions were observed, as assessed by CS‐AFM. The CBNP films acted as exclusive electrochemical transducers as evidenced by using two classes of molecules, that is, neurotransmitters and environmental organic contaminants. These results revealed the potential of these CBNP press‐transferred films for providing new options in microfluidics and other related micro‐ and nanochemistry applications.  相似文献   
30.
A sensitive and reliable high‐performance liquid chromatography–mass spectrometry (LC–MS/MS) was developed and validated for simultaneous quantification IC87114, roflumilast (RFM), and its active metabolite roflumilast N‐oxide (RFN) using tolbutamide as an internal standard. The analytes were extracted by using liquid–liquid extraction and separated on a reverse phase C18 column (50 mm × 3 mm i.d., 4.6 µ) using methanol: 2 mM ammonium acetate buffer, pH 4.0 as mobile phase at a flow rate 1 mL/min in gradient mode. Selective reaction monitoring was performed using the transitions m/z 398.3 > 145.9, 403.1 >186.9, 419.1 > 187.0 and 271.1 > 155.0 to quantify quantification IC87114, RFM, RFN and tolbutamide, respectively. The method was validated over the concentration range of 0.1–60 ng.mL?1 for RFM and RFN and 6 to 2980 ng.mL?1 for IC87114. Intra‐ and inter‐day accuracy and precision of validated method were within the acceptable limits of <15% at all concentrations. Coefficients of correlation (r2) for the calibration curves were >0.99 for all analytes. The quantitation method was successfully applied for simultaneous estimation of IC87114, RFM and RFN in a pharmacokinetic drug–drug interaction study in Wistar rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号