排序方式: 共有38条查询结果,搜索用时 171 毫秒
11.
Group theory can be used to model and synthesize the neighborhood of Traveling Salesman tours reachable through k-OPT exchanges. A primary concept is that a dihedral group action partitions the sets of cut arcs so that k-OPT exchanges of orbital elements are conjugate. Also presented is a method to produce all k-OPT exchanges for a given set of cut arcs. 相似文献
12.
Increased bone water content resulting from repetitive patellofemoral joint overloading has been suggested to be a possible mechanism underlying patellofemoral pain (PFP). To date, it remains unknown whether persons with PFP exhibit elevated bone water content. The purpose of this study was to determine whether recreational runners with PFP exhibit elevated patella water content when compared to pain-free controls. Ten female recreational runners with a diagnosis of PFP (22 to 39 years of age) and 10 gender, age, weight, height, and activity matched controls underwent chemical-shift-encoded water-fat magnetic resonance imaging (MRI) to quantify patella water content (i.e., water-signal fraction). Differences in bone water content of the total patella, lateral aspect of the patella, and medial aspect of the patella were compared between groups using independent t tests. Compared with the control group, the PFP group demonstrated significantly greater total patella bone water content (15.4 ± 3.5% vs. 10.3 ± 2.1%; P = 0.001), lateral patella water content (17.2 ± 4.2% vs. 11.5 ± 2.5%; P = 0.002), and medial patella water content (13.2 ± 2.7% vs. 8.4 ± 2.3%; P < 0.001). The higher patella water content observed in female runners with PFP is suggestive of venous engorgement and elevated extracellular fluid. In turn, this may lead to an increase in intraosseous pressure and pain. 相似文献
13.
Marina Massaro Carmelo G. Colletti Bruno Fiore Valeria La Parola Giuseppe Lazzara Susanna Guernelli Nelsi Zaccheroni Serena Riela 《应用有机金属化学》2019,33(3)
A highly sustainable prototype of a flow system based on gold nanoparticles (4.2 nm) supported on thiol‐functionalized halloysite nanotubes (HNTs) was developed for catalytic applications. The catalytic performances were evaluated using the reduction of 4‐nitrophenol to 4‐aminophenol as a model system. Under the best experimental conditions (0.0001 mol%, 1.97 × 10?8 mg of Au nanoparticles), an impressive apparent turnover frequency value up to 2 204 530 h?1 was achieved and the halloysite‐based catalyst showed full recyclability even after ten cycles. The high catalytic activity confirms the importance of the use of HNTs as support for Au nanoparticles that can exert a synergistic effect both as medium for transfer of electrons from borohydride ions to 4‐nitrophenol and by modulating interfacial electron transfer dynamics. With the application of flow technology, the obtained heterogeneous HNT@Au catalyst was fully recovered and reused for at least one month. 相似文献
14.
MRI was performed in 54 patients with abnormalities of the inferior vena cava (IVC). These included 16 patients with extrinsic IVC compression, 32 patients with intrinsic IVC abnormalities, and 6 patients with IVC dilatation. All patients had spin-echo imaging, and 21 had MR angiography. While presaturated spin-echo images showed intrinsic lesions to advantage, collateral vessels were best appreciated with MR angiography. The IVC is well evaluated with MRI techniques. 相似文献
15.
Hong T. Dang Michael R. Terk Patrick M. Colletti John B. Schlaerth John P. Curtin 《Magnetic resonance imaging》1991,9(6):941-944
MRI evaluation of primary cervical lymphoma has not been reported. We report such a case of primary cervical lymphoma, a lesion well seen and well delineated from normal tissue by MRI. Although primary lymphoma of the cervix is a rare entity, the disease does exist and can be well demonstrated by MRI. We evaluated the MR appearance of this lesion with both nonenhanced and gadolinium-enhanced imaging. 相似文献
16.
P M Colletti A DeFrance T Tak W D Boswell P A Chandraratna 《Magnetic resonance imaging》1991,9(3):343-347
Cardiac cine field echo MRI and color Doppler were performed in 13 patients with aortic regurgitation (n = 4) or multiple valvular diseases (n = 9). The size, shape, and direction of regurgitation jets correlated well. Color Doppler was better able to follow flow jets in oblique planes. Cine MRI was better able to evaluate patients with marked cardiac dilatation. 相似文献
17.
Currently, magnetic resonance (MR) is most useful as a means of providing distinct images of gross abnormalities in major blood vessels. While new advances and further refinements will continue, MR has proven its value as a convenient and effective diagnostic tool for the recognition and delineation of vascular abnormalities, such as acquired arteriovenous fistulae (AVFs). We report a case of a chronic, post-traumatic AVF, in which MR angiography provided excellent anatomic detail and angiographic correlation. 相似文献
18.
Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW) 总被引:2,自引:0,他引:2
We introduce a novel on-chip microparticle focusing technique using standing surface acoustic waves (SSAW). Our method is simple, fast, dilution-free, and applicable to virtually any type of microparticle. 相似文献
19.
Magnetic resonance imaging features in melanoma 总被引:3,自引:0,他引:3
T1 and T2 relaxation time shortening secondary to paramagnetic compounds has been described in melanoma. The purpose of this paper is to evaluate the signal behavior of melanoma involved in various body areas using short TR, TE and long TR, TE sequences. Twenty-seven sites of melanoma were evaluated with MR using T1 weighted and T2-weighted techniques. Using fat and muscle signal intensities as references tissues, lesions were graded into high, low or intermediate intensity categories for each of the sequences. Four signal patterns emerged. The typical pattern characterized by high signal on T1-weighted images and low signal on T2-weighted images reflected T1 and T2 shortening. The other pattern categories comprised of lesions demonstrating low signal T1-weighted images and high signal on T2-weighted images, high signal on both T1- and T2-weighted images and lesions showing intermediate signal on either T1- or T2-weighted images. We observed a tendency away from the typical signal pattern in extraocular melanoma cases with only one of 14 demonstrating this pattern. Moreover, only seven of thirteen ocular melanomas exhibited such behavior. Possible explanations for this findings as well as the existence of a variety of MR appearances to melanoma are offered. We conclude that while signal patterns showing T1 and T2 shortening are typical of melanoma, the absence of these does not exclude the diagnosis. 相似文献
20.
Shen Z Bakhtiar R Komuro M Awano K Taga F Colletti A Hora D Feeney W Iliff S Franklin RB Vincent S 《Rapid communications in mass spectrometry : RCM》2005,19(9):1125-1129
MK-0767, (+/-)-5-[(2,4-dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)phenyl]methyl]benzamide, is a thiazolidinedione-containing dual peroxisome proliferator-activated receptor (PPAR) alpha/gamma agonist that has been studied as a potential treatment for patients with type 2 diabetes. MK-0767 contains a chiral center at the C-5 position of the thiazolidinedione ring and was being developed as the racemate, due to the rapid interconversion of its enantiomers in biological samples. In the present work the in vitro and in vivo concentration ratios of the (+)-(R) to (-)-(S) enantiomers of MK-0767 were determined in plasma from humans (in vitro only) and nonclinical species used in the toxicological evaluation of rac-MK-0767, namely CD-1 mice, Sprague-Dawley rats, beagle dogs, New Zealand white rabbits, and rhesus monkeys. The R/S ratio was determined by chiral liquid chromatography/tandem mass spectrometry. Species differences were observed in the in vitro and in vivo enantiomeric ratios, as well as differences between in vitro and in vivo in some species. The in vitro R/S ratio was similar in dogs and humans (approximately 1.5-1.7). In rats and monkeys, the ratio was approximately unity, both in vitro and in vivo. In mice, the ratio was higher in vitro (approximately 1) than in vivo (approximately 0.6), while in rabbits it was higher in vivo (approximately 1) than in vitro (approximately 0.5). These results suggested that differential binding of the MK-0767 enantiomers to plasma and tissue proteins and other macromolecules may be affecting the R/S ratio both in vitro and in vivo, since in protein-free systems MK-0767 exists as the racemate. 相似文献