排序方式: 共有40条查询结果,搜索用时 15 毫秒
21.
Relevant equivalent circuit parameters and values of material constants of a piezoelectric resonator can be determined from measurements of its electrical input impedance as a function of frequency. The complex electrical impedance curves and the associated critical frequencies are the basis of this characterization by the piezoelectric resonance method. In this paper, the previously introduced concept of normalized electrical impedance of the lossy resonator, extended to include piezoelectric losses, is applied to the analysis of the effects of different types of intrinsic losses on peak values, bandwidths and characteristic frequencies. The resulting impedance patterns depend solely on the electromechanical coupling coefficient and the loss tangents, providing a useful tool for the analysis of low-Q resonators. The normalized impedance is experimentally evaluated from the basic data provided by an HP 4194A impedance analyser by means of specifically developed ASP programs. 相似文献
22.
Hydrogenic (two-body) systems are the only atomic systems for which uncertainties in calculations of the energy levels approach the current state of the art in frequency measurement. This article discusses progress in the theory and measurement of transition frequencies in hydrogenic systems. These studies have relevance to the determination of fundamental constants and the testing of physical theories, especially quantum electrodynamics. A set of high accuracy calculable frequency standards could also be realized by using hydrogenic systems. 相似文献
23.
Performance analysis of a 3D unstructured mesh hydrodynamics code on multi‐core and many‐core architectures
下载免费PDF全文
![点击此处可从《国际流体数值方法杂志》网站下载免费的PDF全文](/ch/ext_images/free.gif)
J. Waltz J. G. Wohlbier L. D. Risinger T. R. Canfield M. R. J. Charest A. R. Long N. R. Morgan 《国际流体数值方法杂志》2015,77(6):319-333
Several next generation high performance computing platforms are or will be based on the so‐called many‐core architectures, which represent a significant departure from commodity multi‐core architectures. A key issue in transitioning large‐scale simulation codes from multi‐core to many‐core systems is closing the serial performance gap, that is, overcoming the large difference in single‐core performance between multi‐core and many‐core systems. In this paper, we discuss how this problem was addressed for a 3D unstructured mesh hydrodynamics code, describe how Amdahl's law can be used to estimate performance targets and guide optimization efforts, and present timing studies performed on multi‐core and many‐core platforms. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. 相似文献
24.
Three sharp absorption features in the energy range 2.36–2.55 eV have been detected in the transmission spectrum of Co-diffused ZnSe, and a number of luminescence transitions originating from the lowest of these states at 2.361 eV have been observed. Photoluminescence excitation spectra prove that these are high energy excited states of the Co2+Zn impurity, a conclusion confirmed by comparison of measured and predicted luminescence energies. This represents the first identification of luminescence branching from a higher excited state of a transition metal ion in any semiconductor. The sharp, weakly phonon-coupled transitions involve either intra-impurity excitation or transitions from the impurity to localised states split off from a minimum in the conduction band. The implications of these observations for the mechanism of host-impurity energy transfer and for the nature of the excited state wavefunctions are discussed. 相似文献
25.
A nodal Godunov method for Lagrangian shock hydrodynamics on unstructured tetrahedral grids
下载免费PDF全文
![点击此处可从《国际流体数值方法杂志》网站下载免费的PDF全文](/ch/ext_images/free.gif)
We present a nodal Godunov method for Lagrangian shock hydrodynamics. The method is designed to operate on three‐dimensional unstructured grids composed of tetrahedral cells. A node‐centered finite element formulation avoids mesh stiffness, and an approximate Riemann solver in the fluid reference frame ensures a stable, upwind formulation. This choice leads to a non‐zero mass flux between control volumes, even though the mesh moves at the fluid velocity, but eliminates volume errors that arise due to the difference between the fluid velocity and the contact wave speed. A monotone piecewise linear reconstruction of primitive variables is used to compute interface unknowns and recover second‐order accuracy. The scheme has been tested on a variety of standard test problems and exhibits first‐order accuracy on shock problems and second‐order accuracy on smooth flows using meshes of up to O(106) tetrahedra. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
26.
Ian Charest Cyril R Pernet Guillaume A Rousselet Ileana Qui?ones Marianne Latinus Sarah Fillion-Bilodeau Jean-Pierre Chartrand Pascal Belin 《BMC neuroscience》2009,10(1):127-11
Background
Previous electrophysiological studies have identified a "voice specific response" (VSR) peaking around 320 ms after stimulus onset, a latency markedly longer than the 70 ms needed to discriminate living from non-living sound sources and the 150 ms to 200 ms needed for the processing of voice paralinguistic qualities. In the present study, we investigated whether an early electrophysiological difference between voice and non-voice stimuli could be observed. 相似文献27.
A direct sample fraction deposition method was developed for off-line size-exclusion chromatography (SEC)/matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. By using electrospray, the SEC eluent, together with a suitable matrix solution added coaxially, was directly deposited on the MALDI plate. Owing to the formation of very small droplets in electrospray, solvent evaporation is much faster. The fractionation volume in narrow-bore SEC, which can directly be collected in one MALDI spot, can easily be optimized in the range of a few microlitres. In addition, fairly homogeneous sample spots were obtained. The possible influence of composition variation of the SEC effluent on the analytical results using direct fraction deposition was investigated; no substantial effects were observed. The applicability of the method was demonstrated by characterizing a broad poly(methyl methacrylate) sample. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
28.
29.
30.