排序方式: 共有59条查询结果,搜索用时 0 毫秒
31.
A design of polarization-maintaining retro-reflectors(PMRRs) for folded-path applications is proposed and analyzed.The prism-based scheme enables the output light,which is parallel to the input,to have an identical state of polarization.The principle of the design is theoretically verified,and the related error is analyzed due to possible manufacturing imperfection.The maximum spatial angle error is ±2.75°.The effect on the extinction ratio and insertion loss is also discussed,which further proves the design’s feasibility in practical applications. 相似文献
32.
本文报道了多光束共振光压作用下钠原子束偏转的实验研究结果。文中提出了用多光束与原子束相互作用以增大原子束的偏转量,并可大大降低对激光功率的要求。用一台染料激光器照射钠原子束得到1×10-2rad的偏转角,偏转距离约7.2mm,并用激光诱导原子束荧光的方法检测原子束的偏转。 相似文献
33.
本文证明了n+k多体系(k≥4)的全部可能的封闭网均可以通过若干相应的子n+3相多体系的拼合运算得出,从而为具体构造n+k相多体系(k≥4)的全部合理的封闭网,提供了基本方法。 相似文献
34.
在文献[1]中,我们导出了超导临界温度T-c的一个严格级数表式.本文讨论这个级数的收敛范围,以及通过解析延拓来扩展收敛范围的可能性.结论是:我们的Tc级数(指文献[1]原来的级数,或者经过延拓后的级数)在∞>λ>λ0的整个范围内,都是收敛的.这里λ0是Matsubara表象中使决定Tc的方程具有正实数解的最小的λ值.它实际上就是库伦赝势.因此,也许除了少数非常弱耦合的超导体以外,我们的Tc级数能适用于一切超导体. 相似文献
35.
36.
RE Tribble A Azhari HL Clark CA Gagliardi Y-W Lui AM Mukhamedzhanov A Sattaroy X Tang L Trache V Burjan J Cejpek V Kroha S Piskor J Vincour F Carstoiu 《Pramana》1999,53(3):585-594
S-factors for direct capture reactions can be found at astrophysical energies from asymptotic normalization coefficients which
provide the normalization of the tail of the overlap function. For example the overlap for 8B → 7Be+p defines the S-factor for 7Be (p, γ)8B. Peripheral transfer reactions offer a technique to determine these asymptotic normalization coefficients. As a test of
the technique, the 16O(3He, d)17F reaction has been used to determine asymptotic normalization coefficients for transitions to the ground and first excited
states of 17F. The S-factors for 16O(p, γ)17F calculated from these 17F → 16O+p asymptotic normalization coefficients are found to be in very good agreement with recent measurements. Following the same
technique, the 10B(7Be, 8B)9Be and 14N(7Be, 8B)13C reactions have been used to measure the asymptotic normalization coefficient for 7Be(p, γ)8B. This result provides an indirect determination of S
17(0). 相似文献
37.
Hoogesteger FJ van Walree CA Jenneskens LW Roest MR Verhoeven JW Schuddeboom W Piet JJ Warman JM 《Chemistry (Weinheim an der Bergstrasse, Germany)》2000,6(16):2948-2959
The photophysical properties of a bicyclohexylidene (1DA) and a bicyclohexyl (2DA) substituted with an anilino electron donor and a dicyanoethylene electron acceptor have been studied. Quenching of local donor emission is observed for these compounds as well as quenching of the "pseudo-local" acceptor emission. Transient absorption spectra show dialkylanilino-type radical-cation and dicyanoethylene-type radical-anion absorptions. These results show that intramolecular charge separation takes place in 1DA and 2DA. This was corroborated by time-resolved microwave conductivity measurements from which large excited-state dipole moments were found for both 1DA and 2DA. Time-resolved fluorescence spectroscopy revealed that in the charge-separated state in cyclohexane for 2DA, molecular folding takes place on a nanosecond timescale. For 1DA in cyclohexane, either charge separation takes place in a (fully) folded conformation or very rapid (subnanosecond timescale) folding takes place subsequent to charge separation. In addition to this difference in conformational behavior, the presence of the exocyclic double bond between the cyclohexyl-type rings results in efficient quenching of the anilino donor triplet state and acceleration of the charge recombination rate by a factor of 20. 相似文献
38.
The objective of this study was to determine if topical anesthesia to the larynx and pharynx affects vocal fold motion during dynamic voice evaluation with transnasal flexible endoscopy. Transnasal dynamic laryngeal examinations of 10 patients with no voice complaints were evaluated by five blinded fellowship-trained laryngologists. Each patient was examined before and after application of topical anesthetic. Reviewers rated briskness of right and left vocal fold movement and longitudinal tension on a visual analogue scale. Statistical comparisons were made between individual subject scores before and after anesthetic application. Inter-rater reliability was also assessed. No statistical difference was observed between subject scores before and after anesthetic application. Average intraclass correlation coefficients were 0.643 and 0.591 for pre- and postanesthesia scores, respectively. Application of topical anesthesia to the larynx and pharynx does not affect vocal fold motion. 相似文献
39.
40.
MJ Lazaro AA Herod M Domin Y Zhuo CA Islas R Kandiyoti 《Rapid communications in mass spectrometry : RCM》1999,13(14):1401-1412
Three methods for determining a 'safe' estimate for high-mass limits of MALDI spectra of coal derived liquids were explored, using a sample of coal-tar pitch and its pyridine-insoluble fraction. Co-addition of increasing numbers of single-shot spectra (10, 30, 50 and 100 pulses) showed visually observable reductions in noise levels, consistent with robust and statistically meaningful signals. Three separate types of post-acquisition calculation were used to identify high-mass limits of the spectra. (i) A literature method indicated high-mass limits similar to those observed visually-as a shift from baseline at the highest masses, nearly 350 000 u for the coal tar pitch and about 390 000 u for its pyridine insoluble fraction. (ii) Comparing instrument signal with pre-selected multiples of the standard deviation, upper mass estimates of between 40-60 000 u for the coal-tar pitch and about 95 000 u for its pyridine-insoluble fraction were found. (iii) Calculation of the slope was used to identify 'lift-off' of the spectrum from baseline. The angle between the smoothed spectrum and the baseline was matched to a pre-selected value (e.g. 0.5 degrees and 1 degrees ). However, the arbitrary specification of the key parameter did not establish this last method on a firm basis. The choice of a criterion for estimating high-mass limits of MALDI spectra remains a semi-quantitative procedure; a reasonably conservative high-mass limit may be estimated by comparison of signal with five times the standard deviation. However, evaluation of size exclusion chromatograms of the present samples using polystyrene standards suggests that molecular mass distributions of pitch samples arrived at by MALDI mass spectrometry are, at least partly, determined by the limitations of available instruments. Copyright 1999 John Wiley & Sons, Ltd. 相似文献