首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   86篇
  免费   0篇
化学   28篇
数学   9篇
物理学   49篇
  2015年   1篇
  2014年   1篇
  2013年   2篇
  2012年   1篇
  2011年   1篇
  2010年   1篇
  2009年   2篇
  2008年   5篇
  2007年   3篇
  2006年   4篇
  2005年   3篇
  2001年   3篇
  2000年   7篇
  1999年   6篇
  1998年   3篇
  1996年   7篇
  1995年   3篇
  1994年   10篇
  1993年   6篇
  1992年   4篇
  1991年   1篇
  1989年   1篇
  1988年   1篇
  1987年   3篇
  1985年   1篇
  1984年   2篇
  1982年   2篇
  1978年   1篇
  1969年   1篇
排序方式: 共有86条查询结果,搜索用时 0 毫秒
61.
Polyaniline deposited on As(2)O(3) surface resulted in a new material, which was characterized by infrared spectoscopy, thermogravimetry, differential scanning calorimetry, scanning electron microscopy, X-ray diffraction, and cyclic voltammetry. The mass percentage of polymer deposited on oxide surface is approximately 13%. The scanning electron microscopy images as well as the X-ray diffraction patterns provided conclusive evidence that the oxide surface is coated by the polymer. The cyclic voltammograms of the polyaniline adsorbed on As(2)O(3) surface showed that the adsorbate exerts remarkable effects on redox processes on this oxide. The pure oxide exhibited two oxidation/reduction peaks at 0.25/-0.06 and 0.47/-0.25 V attributed tentatively to the processes As(2)O(3)(s)+6H(+)+6e(-)=2As(s)+3H(2)O and As(s)+3H(+)+3e(-)=AsH(3)(g), respectively. The polyaniline-coated sample exhibited a better-defined voltammogram in which the first oxidation peak of the oxide had its intensity increased about four times. Copyright 2000 Academic Press.  相似文献   
62.
Kinetics of polyurethane formation between several polyols and isocyanates with dibutyltin dilaurate (DBTDL) as the curing catalyst, were studied in the bulk state by differential scanning calorimetry (DSC) using an improved method of interpretation. The molar enthalpy of urethane formation from secondary hydroxyl groups and aliphatic isocyanates is 72±3 kJ mol-1 and for aromatic isocyanates it is 55±2 kJ mol-1 . In the case of a single second order reaction for aliphatic isocyanates reaction, activation energy is 70±5 kJ mol-1 with oxypropylated polyols and 50±3 kJ mol-1 with Castor oil. For aromatic isocyanates and oxypropylated polyols the activation energy is higher around 77 kJ mol-1 . In the case of two parallel reactions (situation for IPDI and TDI 2-4) best fits are observed considering two different activation energies.  相似文献   
63.
64.
65.
Protein A-coated magnetic beads (0.3 mum) have been trapped in a small portion of a neutrally coated capillary (50 mum id). Anti-beta-lactoglobulin (beta-LG) antibodies have then been immobilized on the beads through strong affinity with protein A to subsequently capture beta-LG from model or real samples. Once the immunocomplexes formed at physiological pH, a discontinuous buffer system has been used to release the partners and preconcentrate them by transient ITP. The antigens and antibodies have finally been separated by CZE and detected by UV absorbance. An LOQ of 55 nM has been achieved. This methodology has been applied to quantify native beta-LG in pasteurized and ultra-high-temperature-treated bovine milk. All the described procedures, including immunosorbent preparation, sample extraction, cleanup, preconcentration, and separation are completely automated on a commercial CE instrument. As this CE immunoassay method is simple, rapid, selective, and sensitive, it should be a practical and attractive technology for the analysis of complicated biological samples.  相似文献   
66.
Carrier ampholyte-based capillary electrophoresis (CABCE) has recently been introduced as an alternative to CE (CZE) in the classical buffers. In this study, isoelectric BGEs were obtained by fractionation of Servalyt pH 4-9 carrier ampholytes to cuts of typical width of 0.2 pH unit. CABCE feasibility was examined on a series of insect oostatic peptides, i.e. proline-rich di- to decapeptides, and phosphinic pseudopeptides--tetrapeptide mimetics synthesized as a mixture of four diastereomers having the -P(O)(OH)-CH(2)- moiety embedded into the peptide backbone. With identical selectivity, the separation efficiency of CABCE proved to be as good as classical CE for the insect oostatic peptides and better for diastereomers of the phosphinic pseudopeptides. In addition, despite the numerous species present in the narrow pH cuts of carrier ampholytes, CABCE seems to be free of system zones that could hamper the analysis. Peak symmetry was good for moderately to low mobile peptides, whereas some peak distortion due to electromigration dispersion, was observed for short peptides of rather high mobility.  相似文献   
67.
The present work reports on the quantification of total IgE in human serum using a microanalytical device whose fluidics is driven by gravity and capillary forces only. Thanks to the eight parallel microchannels in each microchip, calibration and sample analysis are performed simultaneously. A mixture of magnetic bead/analyte/second antibody is incubated off-line and then percolated through the channels where magnetic beads are trapped, enabling the separation of the solid phase from the excess reagents. The entire assay is performed in less than 1 h, and thanks to the miniaturized format, only a small volume of serum is required. Non-specific adsorption was first investigated and a blocking agent compatible with this allergy-based test was chosen. Then, the assay was optimized by determining the best magnetic bead and labelled antibody concentrations. After achievement of a calibration curve with a reference material, the protocol was applied to total IgE quantification of a patient serum sample that showed results in good accordance with those obtained by ImmunoCap® and Immunoaffinity capillary electrophoresis measurements. A detection limit of 17.5 ng ml?1 was achieved and good reproducibility (RSD?
Figure Off-line incubation of the patient sample with anti-IgE grafted magnetic beads and ALP-labelled anti-IgE is carried out in an Eppendorff. Detection is then performed with the GRAVI®-Cell device from DiagnoSwiss, where fluidics is driven by gravity and capillary forces only.
  相似文献   
68.

Background

Recent studies have shown that the human right-hemispheric auditory cortex is particularly sensitive to reduction in sound quality, with an increase in distortion resulting in an amplification of the auditory N1m response measured in the magnetoencephalography (MEG). Here, we examined whether this sensitivity is specific to the processing of acoustic properties of speech or whether it can be observed also in the processing of sounds with a simple spectral structure. We degraded speech stimuli (vowel /a/), complex non-speech stimuli (a composite of five sinusoidals), and sinusoidal tones by decreasing the amplitude resolution of the signal waveform. The amplitude resolution was impoverished by reducing the number of bits to represent the signal samples. Auditory evoked magnetic fields (AEFs) were measured in the left and right hemisphere of sixteen healthy subjects.

Results

We found that the AEF amplitudes increased significantly with stimulus distortion for all stimulus types, which indicates that the right-hemispheric N1m sensitivity is not related exclusively to degradation of acoustic properties of speech. In addition, the P1m and P2m responses were amplified with increasing distortion similarly in both hemispheres. The AEF latencies were not systematically affected by the distortion.

Conclusions

We propose that the increased activity of AEFs reflects cortical processing of acoustic properties common to both speech and non-speech stimuli. More specifically, the enhancement is most likely caused by spectral changes brought about by the decrease of amplitude resolution, in particular the introduction of periodic, signal-dependent distortion to the original sound. Converging evidence suggests that the observed AEF amplification could reflect cortical sensitivity to periodic sounds.  相似文献   
69.
70.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号