首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   37篇
  免费   0篇
化学   25篇
数学   3篇
物理学   9篇
  2022年   1篇
  2015年   1篇
  2014年   1篇
  2013年   2篇
  2012年   2篇
  2011年   2篇
  2010年   3篇
  2008年   2篇
  2007年   2篇
  2006年   2篇
  2002年   1篇
  2000年   1篇
  1999年   2篇
  1998年   1篇
  1994年   1篇
  1993年   1篇
  1992年   1篇
  1987年   1篇
  1985年   1篇
  1984年   1篇
  1983年   3篇
  1982年   2篇
  1977年   1篇
  1976年   1篇
  1974年   1篇
排序方式: 共有37条查询结果,搜索用时 15 毫秒
21.
We report the results of abundant plasma protein depletion on the analysis of underivatized N-linked glycans derived from plasma proteins by nanoLC Fourier-transform ion cyclotron resonance mass spectrometry. N-linked glycan profiles were compared between plasma samples where the six most abundant plasma proteins were depleted (n = 3) through a solid-phase immunoaffinity column and undepleted plasma samples (n = 3). Three exogenous glycan standards were spiked into all samples which allowed for normalization of the N-glycan abundances. The abundances of 20 glycans varying in type, structure, composition, and molecular weight (1,200–3,700 Da) were compared between the two sets of samples. Small fucosylated non-sialylated complex glycans were found to decrease in abundance in the depleted samples (greater than or equal to tenfold) relative to the undepleted samples. Protein depletion was found to marginally effect (less than threefold) the abundance of high mannose, hybrid, and large highly sialylated complex species. The significance of these findings in terms of future biomarker discovery experiments via global glycan profiling is discussed.  相似文献   
22.
First, the basic concept of the vector derivative in geometric algebra is introduced. Second, beginning with the Fourier transform on a scalar function we generalize to a real Fourier transform on Clifford multivector-valued functions Third, we show a set of important properties of the Clifford Fourier transform on Cl3,0 such as differentiation properties, and the Plancherel theorem. Finally, we apply the Clifford Fourier transform properties for proving an uncertainty principle for Cl3,0 multivector functions.  相似文献   
23.
24.
Relaxation of toroidal discharges is described by the principle of minimum energy dissipation together with the constraint of conserved global helicity. The resulting Euler-Lagrange equation is solved in toroidal coordinates for an axisymmetric torus by expressing the solutions in terms of Chandrasekhar-Kendall (C-K) eigenfunctions analytically continued in the complex domain. The C-K eigenfunctions are obtained as hypergeometric functions that are solutions of scalar Helmholtz equation in toroidal coordinates in the large aspect-ratio approximation. Equilibria are constructed by assuming the current to vanish at the edge of plasma. For the m=0, n=0 (m and n are the poloidal and toroidal mode numbers respectively) relaxed states, the magnetic field, current, q (safety factor) and pressure profiles are calculated for a given value of aspect-ratio of the torus and for different values of the eigenvalue λ r 0. The new feature of the present model is that solutions allow for both tokamak as well as RFP-like behaviour with increase in the values of λ r 0, which is related directly to volt-sec in the experiment.  相似文献   
25.
We report an algorithm designed for the calibration of low resolution peptide mass spectra. Our algorithm is implemented in a program called FineTune, which corrects systematic mass measurement error in 1?min, with no input required besides the mass spectra themselves. The mass measurement accuracy for a set of spectra collected on an LTQ-Velos improved 20-fold from ?C0.1776?±?0.0010?m/z to 0.0078?±?0.0006?m/z after calibration (avg?±?95?% confidence interval). The precision in mass measurement was improved due to the correction of non-linear variation in mass measurement accuracy across the m/z range.  相似文献   
26.
We report the use of fluorescence spectroscopy to investigate the amount of material removed from a PTFE surface and detected during desorption electrospray ionization (DESI) mass spectrometry measurements. The fluorescence intensity before and after DESI analysis of rhodamine 6G is used to determine the amount of material removed from the surface per mass spectrum. Calculations indicate low attomole amounts are removed per linear ion trap mass spectrum.  相似文献   
27.
28.
29.
30.
We report a direct comparison of the mass measurement accuracies (MMAs) obtained on different mass spectrometry instrument types; a magnetic sector as the 'gold standard' and an electrospray ionization time-of-flight (ESI-TOF) instrument. Sixty samples, obtained from the Department of Chemistry at North Carolina State University, were analyzed on each instrument. Data are presented and compared between the different instruments. The average absolute MMAs achieved for the magnetic sector and Agilent ESI-TOF mass spectrometers were 3.0 and 1.1 ppm, respectively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号