A simple, robust and sensitive sequential injection spectrofluorimetric method for the determination of penicillamine (PA)
in pharmaceutical formulations is developed. The method is based on the formation of a highly fluorescent derivative when
penicillamine is reacted with fluorescamine (FL) in borate buffer of pH 9.3. The derivative produced is monitored at an emission
wavelength of 495 nm using an excitation wavelength of 355 nm. The optimum conditions for the determination of PA with FL
were: 3 mM FL, pH 9.3, 5 mM methyl-β-cyclodextrin, sample volume of 75 μL and reagent volume of 75 μL. Furthermore, the effect
of various media on the fluorescence intensity of the PA–FL derivative was studied and methyl-β-cyclodextrin was found to
give the largest enhancement. A linear dynamic range for the determination of PA of 5–80 ppm was obtained with a sampling
frequency of 50 h−1 and a relative standard deviation of less than 2.5%. The method was applied to the determination of PA in pharmaceutical
formulations with reasonable recoveries ranging from 101.0–103.1%, indicating that no interference is observed from concomitants
usually present in dosage forms. 相似文献
23.
24.
25.
26.
Ali BH Al-Lawati I Beegam S Ziada A Al Salam S Nemmar A Blunden G 《Natural product communications》2012,7(1):41-44
An aqueous extract of Hibiscus sabdariffa L. is a common beverage in many parts of the world. Reports on its effect on reproduction are conflicting, with anecdotal evidence that the plant is an aphrodisiac, while others report that it is estrogenic, and adversely affects spermatogenesis in rats. We have studied the effect of different concentrations of aqueous extracts of H. sabdariffa calyces (10%, 15% and 20%) used as drinking water for 10 consecutive weeks, and its anthocyanins (50, 100, 200 mg/kg for 5 days, orally) on the weight and histology of the testis, and on some biochemical constituents in testicular homogenates, in addition to the plasma concentrations of testosterone, luteinizing hormone and estradiol. The possible presence of an estrogenic effect of the extract and anthocyanins on the uteri of immature female rats was also tested. Neither the H. sabdariffa extract nor the anthocyanins significantly altered either testicular weight and histology, or uterus weight. Plasma concentrations of the three hormones studied, the testicular concentrations of protein, reduced glutathione and total cholesterol, and superoxide dismutase activity were all insignificantly affected by either the extract or the anthocyanins, except for a slight, but statistically significant, decrease in testicular protein concentration caused by the 15% aqueous extract when compared with controls. These results suggest that H. sabdariffa exerts no adverse effect on the male reproductive system. Consumption of H. sabdariffa aqueous extract inhibited the growth of the rats compared with the controls. 相似文献
27.
Suliman FE Al-Kindi SS Al-Kindy SM Al-Lawati HA 《Journal of chromatography. A》2006,1101(1-2):179-184
A simple, sensitive and rapid reversed-phase high-performance liquid chromatography (RP-HPLC) method is proposed for the analysis of some environmentally important phenols in water. The use of coumarin-6-sulphonyl chloride (C6SCl) as a fluorescence-labeling reagent has been investigated. The compound reacts with phenols within 20 min under mild conditions (ambient temperature, pH 9.0) to give sulphonates that can be separated by RP-HPLC employing fluorescence detection at lambda(ex) = 360 and lambda(em) = 460 nm. The optimum conditions for fluorescence, derivatization and chromatographic separation have been established and detection limits in the range 0.1-0.9 microg l(-1) were obtained for the studied compounds. The calibration curves were linear for the range 6-200 microg l(-1) for phenol, 3-200 microg l(-1) for 2-chlorophenol, 4-chlorophenol and 2,3,5-trichlorophenol and for the range of 3-100 microg l(-1) for 2,3-dichlorophenol and 3,5-dichlorophenol. The practical applicability of the method to environmental samples was demonstrated by analyzing drinking and industrial water samples spiked with the phenolic compounds. 相似文献
28.
A highly efficient protein digestion device has been fabricated using commercially available immobilized trypsin on agarose beads, packed into a silica capillary and connected either directly to an electrospray mass spectrometer via a 'microtight T' connector, from which aqueous acetic acid (0.2%) was pumped, or via a monolithic column connected to the mass spectrometer ion source. Six proteins with molecular mass ranging from 2848 to 77703 Da were digested completely using this system. In the second set of experiments a short monolithic separation column was placed after the immobilized trypsin capillary and partial separation of the generated peptides was obtained. The detection limits were increased from the micromol to pmol range by utilization of this separation column. Gradient elution, using a binary HPLC pump and a flow splitter, was used to optimize the peptide separation. This provided significantly enhanced resolution of the tryptic peptides but increased the analysis time to 30 minutes. 相似文献
29.
Munshi G Mustafa Sudhir Raniwala T Awes B Rai RS Bhalerao JG Contreras RV Gavai SK Ghosh P Jaikumar GC Mishra AP Mishra H Mishra B Mohanty J Nayak J-Y Ollitrault SC Phatak L Ramello R Ray PK Sahu AM Srivastava DK Srivastava VK Tiwari 《Pramana》2006,67(5):961-981
This is the report of Heavy Ion Physics and Quark-Gluon Plasma at WHEPP-09 which was part of Working Group-4. Discussion and
work on some aspects of quark-gluon plasma believed to have created in heavy-ion collisions and in early Universe are reported. 相似文献
30.
RE Tribble A Azhari HL Clark CA Gagliardi Y-W Lui AM Mukhamedzhanov A Sattaroy X Tang L Trache V Burjan J Cejpek V Kroha S Piskor J Vincour F Carstoiu 《Pramana》1999,53(3):585-594
S-factors for direct capture reactions can be found at astrophysical energies from asymptotic normalization coefficients which
provide the normalization of the tail of the overlap function. For example the overlap for 8B → 7Be+p defines the S-factor for 7Be (p, γ)8B. Peripheral transfer reactions offer a technique to determine these asymptotic normalization coefficients. As a test of
the technique, the 16O(3He, d)17F reaction has been used to determine asymptotic normalization coefficients for transitions to the ground and first excited
states of 17F. The S-factors for 16O(p, γ)17F calculated from these 17F → 16O+p asymptotic normalization coefficients are found to be in very good agreement with recent measurements. Following the same
technique, the 10B(7Be, 8B)9Be and 14N(7Be, 8B)13C reactions have been used to measure the asymptotic normalization coefficient for 7Be(p, γ)8B. This result provides an indirect determination of S
17(0). 相似文献