首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   120篇
  免费   10篇
  国内免费   3篇
化学   117篇
力学   1篇
数学   5篇
物理学   10篇
  2022年   3篇
  2021年   3篇
  2020年   6篇
  2019年   5篇
  2018年   9篇
  2017年   2篇
  2016年   7篇
  2015年   9篇
  2014年   10篇
  2013年   12篇
  2012年   9篇
  2011年   8篇
  2010年   11篇
  2009年   3篇
  2008年   5篇
  2007年   10篇
  2006年   2篇
  2005年   4篇
  2004年   1篇
  2003年   2篇
  2002年   7篇
  1998年   1篇
  1990年   1篇
  1984年   1篇
  1982年   1篇
  1981年   1篇
排序方式: 共有133条查询结果,搜索用时 15 毫秒
61.
The reversed-phase high-performance liquid chromatographic (RP-HPLC) behavior of some newly synthesized hydroxythioxanthone derivatives using binary acetonitrile-water mixtures as mobile phase has been examined. First, the variation in the retention time of each molecule as a function of mobile phase properties was studied by Kamlet-Taft solvatochromic equations. Then, the influences of molecular structure of the hydroxythioxanthone derivatives on their retention time in various mobile phase mixtures were investigated by quantitative structure-property relationship (QSPR) analysis. Finally, a unified model containing both the molecular structure parameters and mobile phase properties was developed to describe the chromatographic behavior of the systems studied. Among the solvent properties, polarity/polarizability parameter (π*) and hydrogen-bond basicity (β), and among the solute properties, the most positive local charge (MPC), the sum of positive charges on hydrogen atoms contributing in hydrogen bonding (SPCH) and lipophilicity index (log P) were identified as controlling factors in the RP-HPLC behavior of hydroxythioxanthone derivatives in actonitrile-water binary solvents.  相似文献   
62.
The objective of this study was to synthesize and characterize a set of biodegradable block copolymers based on TPGS-block-poly(ε-caprolactone) (TPGS-b-PCL) and to assess their self-assembled structures as a nanodelivery system for paclitaxel (PAX). The conjugation of PCL to TPGS was hypothesized to increase the stability and the drug solubilization characteristics of TPGS micelles. TPGS-b-PCL copolymer with various PCL/TPGS ratios were synthesized via ring opening bulk polymerization of ε-caprolactone using TPGS, with different molecular weights of PEG (1–5 kDa), as initiators and stannous octoate as a catalyst. The synthesized copolymers were characterized using 1H NMR, GPC, FTIR, XRD, and DSC. Assembly of block copolymers was achieved via the cosolvent evaporation method. The self-assembled structures were characterized for their size, polydispersity, and CMC using dynamic light scattering (DLS) technique. The results from the spectroscopic and thermal analyses confirmed the successful synthesis of the copolymers. Only copolymers that consisted of TPGS with PEG molecular weights ≥ 2000 Da were able to self-assemble and form nanocarriers of ≤200 nm in diameter. Moreover, TPGS2000-b-PCL4000, TPGS3500-b-PCL7000, and TPGS5000-b-PCL15000 micelles enhanced the aqueous solubility of PAX from 0.3 µg/mL up to 88.4 ug/mL in TPGS5000-b-PCL15000. Of the abovementioned micellar formulations, TPGS5000-b-PCL15000 showed the slowest in vitro release of PAX. Specifically, the PAX-loaded TPGS5000-b-PCL15000 micellar formulation showed less than 10% drug release within the first 12 h, and around 36% cumulative drug release within 72 h compared to 61% and 100% PAX release, respectively, from the commercially available formulation (Ebetaxel®) at the same time points. Our results point to a great potential for TPGS-b-PCL micelles to efficiently solubilize and control the release of PAX.  相似文献   
63.
Bismuth nanostructure‐carbon ionic liquid electrode has been employed for sensitive determination of cysteine (Cys). Bismuth nanostructure was incorporated into the carbon ionic liquid electrode (CILE) and applied for determination of cysteine. An interaction was taking place between bismuth nanostructure and the thiol group of cysteine. The bismuth cysteinate complex oxidation potential occurred at more negative potential compared to the cysteine oxidation peak obtained at bare carbon ionic liquid electrode (CILE). Square wave voltammetry (SWV) was used for the determination of the cysteine and satisfactory results were obtained. The calibration curve was linear in the concentration range of 1 to 500 µM and 0.5–2 mM of Cys. A low detection limit of 0.5 µM was achieved for Cys. The electrode showed a good selectivity for determination of cysteine in the presence of other amino acids. The proposed electrode was satisfactory applied for the determination of cysteine in human serum plasma sample.  相似文献   
64.
A sensitive catalytic method for determining ng ml? concentration of selenium is described. The method is based on the catalytic action of Se(IV) on the reduction of resazurin by sulphide, monitored spectrophotometrically at 605 nm. The linearity range of the calibration graph is dependent on the concentration of sulphide. The variables affecting the rate of the reaction were investigated and the optimum conditions were established. The method is simple, rapid, precise, sensitive and widely applicable. As low as 8.0 × 10?4 μg ml?1 of selenium can be determined. The relative standard deviation of seven determination of 10 ng Se was 0.7%. The determination of Se(IV) in the presence of Se(VI) and the determination of total selenium are also described.  相似文献   
65.
In this paper, a survey has been undertaken to clarify the possible reasons for the electrocatalytic activity obtained by the presence of ionic liquid in carbon paste electrode (CPE). For this purpose, the effect of the addition of traces of ionic liquid to conventional CPE was investigated. Fe(CN)63?/4? was used as a probe and two ionic liquids, namely n‐octylpyridinum hexafluorophosphate and 1‐octyl‐3‐methylimidazolium hexaflourophosphate were tested for their electrocatalytic activity. The reasons for this electrocatalytic behavior were evaluated and it was found that different factors such as increase in the ionic conduction of the binder, decrease in the resistance of the modified electrode, increase in ion exchange properties of the electrode and the inherent catalytic activity of ionic liquids are responsible for the considerable improved electrochemical response obtained in the presence of traces of ionic liquid.  相似文献   
66.
A novel optical sensor has been proposed for sensitive determination of thorium (IV) ion in aqueous solutions. The thorium sensing membrane was prepared by incorporating 4-(p-nitrophenyl azo)-pyrocatechol (NAP) as ionophore in the plasticized PVC membrane containing tributyl phosphate (TBP) as plasticizer. The membrane responds to thorium ion by changing color reversibly from yellow to red-brown in glycine buffer solution at pH 3.5. The proposed sensor displays a linear range of 8.66 × 10−6-2.00 × 10−4 M with a limit of detection of 6 × 10−6 M. The response time of the optode was about 8.8-12.5 min, depending on the concentration of Th (IV) ions. The selectivity of optode to Th (IV) ions in glycine buffer is good. The sensor can readily be regenerated by exposure to a solution mixture of sodium fluoride and 5-sulfosalicylic acid (dihydrate) (0.01 M each). The optode is fully reversible. The proposed optode was applied to the determination of thorium (IV) in environmental water samples.  相似文献   
67.
A rapid and sensitive flow-injection chemiluminescence method is described for the determination of dichloro- and trichloroisocyanuric acids based on the chemiluminescence produced during their reaction with luminol in alkaline medium. The effects of analytical and flow-injection variables on these chemiluminescence systems and determination of both oxidants are discussed. The optimized method yielded 3sigma detection limits of 8x10(-8) and 5x10(-8) mol L(-1) for the sodium dichloroisocyanurate and trichloroisocyanuric acid, respectively. The optimum conditions were found to be as follows: NaOH, 1x10(-1) mol L(-1); luminol, 5x10(-3) mol L(-1); KI, 2x10(-3) mol L(-1) and flow rate, 3.5 mL min(-1).  相似文献   
68.
The characterization of an optical sensor membrane is described for indirect determination of isoniazid. The sensing membrane was consisted of immobilized 3-(2-pyridyl)-5,6-diphenyl-1,2,4-triazine (PDT) on a triacetylcellulose membrane. The procedure is based on the reaction of Fe(III) with isoniazid in the presence of PDT. Fe(III) is reduced by isoniazid to Fe(II) which forms a complex with PDT. The complex shows an absorption maximum at 558nm. By measuring the absorbance of the complex at this wavelength, isoniazid can be determined in the range of 0.62-6.15mugmL(-1). This method was applied to the determination of isoniazid in pharmaceutical formulation and enabled the determination of isoniazid in microgram quantities.  相似文献   
69.
An optical probe responsive to gallium(III) ion has been developed. The gallium sensing system was prepared by incorporating 4-(p-nitrophenyl azo)-pyrocatechol (NAP) as ionophore in a plasticized PVC membrane containing tributylphosphate (TBP) as plasticizer. The sensing membrane in contact with gallium ion at pH 3.5, changes color from yellow-brown to pink-brown. Under optimum conditions, the proposed membrane displayed a linear range of 5-83 μM with a limit of detection of 4 μM. The response time of the membrane was within 10-15 min depending on the concentration of Ga3+ ions. The selectivity of the probe towards gallium determination was found to be very good. Experimental results showed that the probe could be used as an effective tool in analyzing the gallium content of water samples.  相似文献   
70.
Hemoglobin (Hb) was directly immobilized on a multiwalled carbon nanotubes ionic liquid electrode by immersing this electrode in a solution consisting of Hb and 1‐octyl‐pyridinium chloride as an ionic liquid. The immobilized Hb displayed a pair of well‐defined cyclic voltammetric peaks with a formal potential of ?0.187 V in acetate buffer solution, pH 5.0. This modified electrode exhibits fast response, a long linearity range, a low detection limit, high stability and excellent sensitivity through hydrogen peroxide detection with a detection limit (3σ) of 3.18 µM. The electrode was also used for electrocatalysis and voltammetric determination of oxygen and trichloroacetic acid.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号