首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   52篇
  免费   0篇
化学   20篇
数学   2篇
物理学   30篇
  2021年   1篇
  2019年   1篇
  2014年   2篇
  2013年   1篇
  2012年   2篇
  2010年   2篇
  2009年   3篇
  2008年   4篇
  2007年   1篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  2001年   2篇
  2000年   3篇
  1999年   2篇
  1996年   2篇
  1995年   1篇
  1994年   5篇
  1993年   3篇
  1992年   5篇
  1991年   4篇
  1989年   2篇
  1980年   1篇
  1976年   1篇
排序方式: 共有52条查询结果,搜索用时 0 毫秒
21.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
22.
R Palit  HC Jain  PK Joshi  JA Sheikh 《Pramana》2001,57(1):191-194
Lifetimes of high spin states up to { }=22+ in the yrast positive parity bands have been measured to investigate the shape evolution with increasing spin in 72, 74Se. The Q t values derived from these measurements indicate that prolate shape stabilizes for 72Se, while a triaxial shape develops for 74Se at higher spins. Comparison of the observed trend in Q t with spin for 72, 74Se with that of the corresponding kryptones isotones emphasizes the stability provided by N=38 prolate shell gap even at high rotational frequency.  相似文献   
23.
通过三氯锗仿与抗坏血酸分子的加成反应,合成了一种新型有机锗倍半氧化物,产物的结构通过元素分析、IR及UV光谱等方法进行了表征.生物活性实验表明合成物对小鼠S-180肿瘤生长具有显著的抑制作用.  相似文献   
24.
The radial distribution of the main characteristics (elution time and standard deviation) of the elution profiles of a flat injected band recorded at the exit of a monolithic column were determined. These distributions provide the radial distributions of the average mobile phase velocity, the elution time and the maximum height of the peak of an analyte, the column efficiency and the analyte concentration. The band profiles were measured at the exit of a 10-mm i.d., 100-mm long silica-based monolithic column. An on-column local electrochemical amperometric detector allowed the recording of the elution profiles at different spatial positions throughout the column cross-section. The local spatial distribution of the mobile phase velocity does not follow a piston-flow behavior but exhibits radial heterogeneity. The local efficiency near the wall is lower than that near the column center. The radial distribution of the maximum concentration of the peaks varies throughout the column exit section, partially due to the radial variations of the column efficiency. These results might explain the rather large value of the A term of the Van Deemter or the Knox equations reported previously for monolithic columns.  相似文献   
25.
钛酸钡纳米粉体样品用盐酸溶解,在所得样品溶液中用电感耦合等离子体原子发射光谱法测定了以氧化物存在于样品中的7种杂质元素(包括镁、锶、钾、钠、铝、硅及铁),对测定的光谱条件进行了试验并优化达到上述各元素的测定上限为0.1%(质量分数).测得方法的检出限(3S/b)为(单位μg·L-1):2.0(铝),1.0(铁),20.0(钾),0.2(镁),4.0(钠),3.0(硅)及0.5(锶).应用此方法分析了两件实样,所得结果的相对标准偏差(n=6)小于等于2.0%,对其中4种杂质元素(镁、钾、钠和锶)同时用HG/T 3587-1999标准中的方法作分析校核,所得结果与此方法结果一致.  相似文献   
26.
27.
28.
29.
30.
An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm × 4.6 mm C18 bonded silica-based monolithic column, a 150 mm × 4.6 mm column packed with 2.7 μm porous shell particles of C18 bonded silica (HALO), and a 150 mm × 4.6 mm column packed with 3 μm fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35–50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5–4.0% lower in the wall region for the two particle-packed columns.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号