首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   190篇
  免费   12篇
  国内免费   4篇
化学   137篇
晶体学   2篇
力学   5篇
数学   36篇
物理学   26篇
  2023年   1篇
  2022年   2篇
  2021年   8篇
  2020年   6篇
  2019年   7篇
  2018年   9篇
  2017年   8篇
  2016年   15篇
  2015年   11篇
  2014年   16篇
  2013年   15篇
  2012年   24篇
  2011年   15篇
  2010年   10篇
  2009年   11篇
  2008年   14篇
  2007年   5篇
  2006年   6篇
  2005年   6篇
  2004年   6篇
  2003年   3篇
  2002年   4篇
  2001年   2篇
  1999年   1篇
  1994年   1篇
排序方式: 共有206条查询结果,搜索用时 15 毫秒
31.
Bismuth-modified glassy carbon electrodes have been investigated for their suitability in sonoelectroanalysis. The stability of the bismuth film to the application of ultrasound was assessed via voltammetric and atomic force microscopy (AFM) studies which revealed little ablation at powers up to an intensity of 130 W cm–2 delivered from a 25-kHz sonic horn. Furthermore, bismuth-film-modified glassy carbon electrodes were evaluated for the sonoelectroanalytical quantification of zinc and cadmium. Detection limits of 2×10–7 M and 6×10–9 M respectively were found after a 60-s deposition time via an acoustically assisted deposition protocol.  相似文献   
32.
Silica-bonded S-sulfonic acid (SBSSA) is employed as a recyclable catalyst for the condensation reaction of aromatic aldehydes with 3-methyl-l-phenyl-5-pyrazolone. This condensation reaction was performed in ethanol under refluxing conditions giving 4,4′-alkylmethylene-bis(3-methyl-5-pyrazolones) in 75-90% yields.  相似文献   
33.
Potential cycling was used for oxidation of chloropromazine and producing an electroactive redox couples which strongly adsorbed on the electrode surface modified with carbon nanotubes and ionic liquid nanocomposite. The modified electrode shows excellent electrocatalytic activity toward NADH oxidation. The differential pulse voltammetry detection provided high sensitivity, 0.5835 A M?1, low detection limit, 80 nM at concentration range up to 20 μM. An ethanol biosensor was also developed by immobilizing alcohol dehydrogenase enzyme onto nanocomposite. Differential pulse voltammetric detection of ethanol gives linear responses over the concentration range 40 μM–1.5 mM with detection limit 5 μM and sensitivity 1.97 μA mM?1.  相似文献   
34.
Direct electron transfer of immobilized superoxide dismutase (Cu, Zn‐SOD) onto silicon carbide (SiC) nanoparticles displays a pair of well defined and nearly reversible redox peaks with formal potential (′) of −0.03 V in pH 7.4. The heterogeneous electron transfer rate constant (ks) and surface coverage (Γ) of immobilized SOD are 11.0±0.4 s−1 and 1.42×10−11 mol cm−2. Biosensor shows fast amperometric response (3s) with sensitivity and detection limit of 1.416 nA μM−1, 1.66 μM, and 1.375 nA μM−1, 2.1 μM for cathodically or anodically detection of superoxide, respectively. This biosensor also exhibits good stability, reproducibility and long life‐time.  相似文献   
35.
We have synthesized epoxy nanocomposites with various percents of nanoalumina by using ultrasonic dispersion treatment. Scanning calorimetry studies revealed that the composition having 1% nanoalumina results in the highest value of cross-link density as evidenced by the glass transition temperature (T g). Thermal degradation of the systems consisting of diglycidyl ether bisphenol A (DGEBA)/1,3-Poropane diamine and with 1% and without nanoalumina were studied by thermogravimetry analysis to determine the reaction mechanism in air. The obtained results indicated that a relatively low concentration of nanoalumina led to an impressive improvement of thermal stability of epoxy resin. The Coats?CRedfern, Van Krevelen, Horowitz?CMetzger, and Criado methods were utilized to find the solid state thermal degradation mechanism. Analysis of our experimental results suggests that the reaction mechanism is depending on the applied thermal history. For the nanocomposite, the mechanism was recognized to be one-dimensional diffusion (D1) reaction at low heating rates and it changes to be a random nucleation process with one nucleus on the individual particle (F1) at high heating speeds. The results also indicated that the degradation mechanism of organic phase is influenced by the presence of inorganic nanofiller.  相似文献   
36.
Salimi A  Pourbeyram S 《Talanta》2003,60(1):205-214
A renewable three-dimensional chemically modified carbon ceramic electrode containing Ru [(tpy)(bpy)Cl] PF6 was constructed by sol-gel technique. It exhibits an excellent electro-catalytic activity for oxidation of l-cysteine and glutathione at pH range 2-8. Cyclic voltammetry was employed to characterize the electrochemical behavior of the chemically modified electrode. The electrocatalytic behavior is further exploited as a sensitive detection scheme for l-cysteine and glutathione by hydrodynamic amperometry. Optimum pH value for detection is 2 for both l-cysteine and glutathione. The catalytic rate constants for l-cysteine and glutathione were determined, which were about 2.1×103 and 2.5×103 M−1 s−1, respectively. Under the optimized condition the calibration curves are linear in the concentration range 5-685 and 5-700 μM for l-cysteine and glutathione determination, respectively. The detection limit (S/N=3) and sensitivity is 1 μM, 5 nA/μM for l-cysteine and 1 μM, 7.8 nA/μM for glutathione. The relative standard deviation (RSD) for the amperogram's currents with five injections of l-cysteine or glutathione at concentration range of linear calibration is <1.5%. The advantages of this amperometric detector are: high sensitivity, good catalytic effect, short response time (t<3 s), remarkable long-term stability, simplicity of preparation and reproducibility of surface fouling (RSD for six successive polishing is 3.31%). This sensor can be used as a chromatographic detector for analysis of l-cysteine and glutathione.  相似文献   
37.
38.
39.
Boronic acid functionalized materials have gained much attention in both chemistry and biology fields due to their multivalent covalent interactions with cis-diol containing (macro) molecules. The remarkable progress in this field has resulted in the development of their biomedical applications, such as, biosensors and nanocarriers. In this study, the spherical nanoparticles consisting of glycerol and 2,5-thiophenediylbisboronic acid were synthesized by one-pot ring opening copolymerization of a mixture of glycidol and 2,5-thiophenediylbisboronic acid. The synthesized nanoparticles were used for the modification of the glassy carbon electrode and the determination of Guaifenesin. The synthesized polymeric nanoparticles were characterized by different spectroscopic and microscopic methods including UV–vis, IR, NMR, DLS, and SEM. Additionally, the electrochemical behavior of the fabricated electrode toward Guaifenesin was investigated with cyclic voltammetry and electrochemical impedance spectroscopy.  相似文献   
40.
Salimi A  Mamkhezri H  Hallaj R 《Talanta》2006,70(4):823-832
A sol-gel carbon composite electrode (CCE) has been prepared by mixing a sol-gel precursor (e.g. methyltrimethoxysilane) and carbon powder without adding any electron transfer mediator or specific reagents. It was demonstrated that this sensor can be used for simultaneous determination ascorbic acid, neurotransmitters (dopamine and adrenaline) and uric acid. Direct electrochemical oxidation of ascorbic acid, uric acid and catecholamines at a carbon composite electrode was investigated. The experimental results were compared with other common carbon based electrodes, specifically, boron doped diamond, glassy carbon, graphite and carbon paste electrodes. It was found that the CCE shows a significantly higher of reversibility for dopamine. In addition, in comparison to the other electrodes used, for CCE the oxidation peaks of uric acid, ascorbic acid and catecholamines in cyclic and square wave voltammetry were well resolved at the low positive potential with good sensitivity. The advantages of this sensor were high sensitivity, inherent stability and simplicity and ability for simultaneous determination of uric acid, catecholamines and ascorbic acid without using any chromatography or separation systems. The analytical performance of this sensor has been evaluated for detection of biological molecules in urine and serum as real samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号