首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   148篇
  免费   13篇
化学   130篇
晶体学   1篇
力学   4篇
数学   9篇
物理学   17篇
  2023年   1篇
  2022年   2篇
  2021年   6篇
  2020年   11篇
  2019年   6篇
  2018年   9篇
  2017年   3篇
  2016年   12篇
  2015年   7篇
  2014年   8篇
  2013年   20篇
  2012年   10篇
  2011年   14篇
  2010年   4篇
  2009年   5篇
  2008年   5篇
  2007年   12篇
  2006年   9篇
  2005年   6篇
  2004年   1篇
  2003年   3篇
  2002年   1篇
  2001年   1篇
  1999年   2篇
  1984年   1篇
  1983年   1篇
  1974年   1篇
排序方式: 共有161条查询结果,搜索用时 15 毫秒
1.
Previous hotel performance studies neglected the role of information entropy in feedback processes between input and output management. This paper focuses on this gap by exploring the relationship between hotel performance at the industry level and the capability of learning by doing and adopting best practices using a sample of 153 UK hotels over a 10-year period between 2008–2017. Besides, this research also fills a literature gap by addressing the issues of measuring hotel performance in light of negative outputs. In order to achieve this, we apply a novel Modified slack-based model for the efficiency analysis and Least Absolute Shrinkage and Selection Operator to examine the influence of entropy related variable on efficiency score. The Results indicate that less can be learnt from inputs than from outputs to improve efficiency levels and resource allocation is more balanced than cash flow and liquidity. The findings suggest that market dynamics explains the cash flow generation potential and liquidity. We find that market conditions are increasingly offering the opportunities for learning and improving hotel efficiency. The results report that the distinctive characteristic of superior performance in hotel operations is the capability to match the cash flow generation potential with market opportunities.  相似文献   
2.
A reduced surface electric field in AlGaN/GaN high electron mobility transistor (HEMT) is investigated by employing a localized Mg-doped layer under the two-dimensional electron gas (2-DEG) channel as an electric field shaping layer. The electric field strength around the gate edge is effectively relieved and the surface electric field is distributed evenly as compared with those of HEMTs with conventional source-connected field plate and double field plate structures with the same device physical dimensions. Compared with the HEMTs with conventional source-connected field plate and double field plate, the HEMT with Mg-doped layer also shows that the breakdown location shifts from the surface of the gate edge to the bulk Mg-doped layer edge. By optimizing both the length of Mg-doped layer, Lm, and the doping concentration, a 5.5 times and 3 times the reduction in the peak electric field near the drain side gate edge is observed as compared with those of the HEMTs with source-connected field plate structure and double field plate structure, respectively. In a device with VGS=-5 V, Lm=1.5 μm, a peak Mg doping concentration of 8× 1017 cm-3 and a drift region length of 10 μm, the breakdown voltage is observed to increase from 560 V in a conventional device without field plate structure to over 900 V without any area overhead penalty.  相似文献   
3.
4.
A new stereoselective synthesis of lysophosphatidylcholines is reported. The synthesis is based upon (1) the use of 3-p-toluenesulfonyl-sn-glycerol to provide the stereocenter for construction of the optically active lysophospholipid molecule, (2) tetrahydropyranylation of the secondary alcohol function to achieve orthogonal protection of the sn-2- and sn-3-glycerol positions, and (3) elaboration of the phosphodiester headgroup using a 2-chloro-1,3,2-dioxaphospholane/trimethylamine sequence. In the course of developing the synthesis it has been discovered that methoxyacetate displacement of the sn-3-p-toluenesulfonate yields a reactive methoxyacetyl ester, which in turn can be selectively cleaved with methanol/tert-butylamine, while the ester group at the sn-1-position remains unaffected. The sequence has been shown to be suitable for preparation of spectroscopically labeled lysophosphatidylcholines. One of these compounds was readily converted to a double-labeled mixed-chain phosphatidylcholine applicable for real-time fluorescence resonance energy transfer (FRET) assay of lipolytic enzymes. In addition, the work led to new synthetic strategies based on chemoselective manipulation of the tosyl group in the presence of other base-labile groups such as FMOC derivatives that are often used for the protection of amino and hydroxyl groups in syntheses.  相似文献   
5.
A simple isocratic reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the simultaneous determination of buprenorphine hydrochloride, naloxone hydrochloride dihydrate and its major impurity, noroxymorphone, in pharmaceutical tablets. The chromatographic separation was achieved with 10 mmol L−1 potassium phosphate buffer adjusted to pH 6.0 with orthophosphoric acid and acetonitrile (17:83, v/v) as mobile phase, a C-18 column, Perfectsil Target ODS3 (150 mm × 4.6 mm i.d., 5 μm) kept at 35 °C and UV detection at 210 nm. The compounds were eluted isocratically at a flow rate of 1.0 mL min−1. The average retention times for naloxone, noroxymorphone and buprenorphine were 2.4, 3.8 and 8.1 min, respectively. The method was validated according to the ICH guidelines. The validation characteristics included accuracy, precision, linearity, range, specificity, limit of quantitation and robustness. The calibration curves were linear (r > 0.996) over the concentration range 0.22-220 μg mL−1 for buprenorphine hydrochloride and 0.1-100 μg mL−1 for naloxone hydrochloride dihydrate and noroxymorphone. The recoveries for all three compounds were above 96%. No spectral or chromatographic interferences from the tablet excipients were found. This method is rapid and simple, does not require any sample preparation and is suitable for routine quality control analyses.  相似文献   
6.
The interactions of rare gas atoms (Rg = Ar, Kr, and Xe) with small neutral and cationic silver clusters have been investigated by density functional methods and the effect of these weak interactions on the resonance Raman spectra of the complexes has been evaluated. The resonance Raman technique that depends on the properties of ground and excited state, seems deeply sensitive to the weak rare gas–metal cluster interactions, and the use of inert gases has been proven to be an excellent approach to recognize the ability of this technique to detect extremely weak interactions. In this work, for , and complexes the IR, normal and resonance Raman spectra have been calculated and the effect of rare gas–cluster stretching vibration ( ) on the pattern and the relative intensities of different spectra have been investigated. The resonance Raman spectra for the weakly interacted complexes (with the interaction energies less than ?2.0 kcal/mol) exhibit the vibration with the detectable intensity that its intensity increases by going from Ag6–Ar to Ag6–Xe complex. Moreover, the resonance Raman spectra (based on the excited state gradient approximation) for high intensity nearly degenerate excited states, proved the effect of accumulation of the excited state charge density on the relative intensity of vibration.  相似文献   
7.
Research on Chemical Intermediates - This article presents an ultrasound-assisted dispersive magnetic solid-phase extraction method (USA-DMSPE) to preconcentration Cd(II) and Pb(II) simultaneously....  相似文献   
8.
A novel heterogeneous nanocatalyst was established by supporting molybdenum (VI) on Zr6 nodes in the structure of the well‐known UiO‐66 metal–organic framework (MOF). The structure of the UiO‐66 before and after Mo (VI) immobilization was confirmed with XRD, DR‐FTIR and UV–vis spectroscopy, and the presence and amount of Mo (VI) was identified by X‐ray photoelectron spectroscopy and inductively coupled plasma atomic emission spectroscopy. TEM imaging confirmed the absence of Mo clusters on the MOF surface, while SEM confirmed that the appearance of the MOF has not changed upon immobilizing the Mo (VI) catalyst. BET adsorption measurements were used to confirm the porosity of the catalyst. The catalytic activity of this heterogeneous catalyst was investigated in oxidation of sulfides with H2O2 in acetonitrile and oxidative desulfurization of dibenzothiophene. Easy work up, convenient and steady reuse and high activity and selectivity are prominent properties of this new hybrid material.  相似文献   
9.
A simple and practical procedure for synthesis of 2-arylbenzimidazoles by a one-pot condensation of o-phenylenediamine with aromatic aldehydes in the presence of a catalytic amount of M(NO3)2·6H2O (M = Mn, Fe, Co, Ni, Cu) in ethanol at room temperature is described. Major advantages of this practical procedure are use of a readily available catalyst, high yields, short reaction times, and simplicity of the reaction and workup.  相似文献   
10.
In this work, a novel, efficient, and green sorbent, SiO2@Fe3O4 has been created and functionalized with 1‐butyl‐3‐methylimidazolium hexafluorophosphate as an ionic liquid. This sorbent was applied for microextraction of four beta blockers, propranolol, metoprolol, atenolol, and alprenolol with bupivacaine as internal standard from human plasma followed by liquid chromatography with mass spectrometric detection. A mixture of sodium bicarbonate and sodium dihydrogen phosphate was used as an extractant dispersive agent (effervescent power) to enhance the interaction between the magnetic sorbent and analytes. Main affecting parameters on microextraction and elution were optimized. Figures of merit for dispersive solid phase extraction with ionic liquid coated magnetic nanoparticles assisted by effervescent powder were calculated under the optimized conditions. The detection limits for propranolol, metoprolol, atenolol, and alprenolol were found at 0.33, 0.62, 0.03, and 0.44 ng/mL, respectively. For all analytes, good linearity was obtained. Intra‐ (n = 5) and interday (n = 10) precision were both under 6.3% while the preconcentration factors were obtained in the range between 15–18. The extraction efficiencies for each analyte ranged from 75 to 91%. The method was successfully applied for determination of trace amounts of the beta blockers in human plasma samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号