首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   48篇
  免费   2篇
化学   37篇
数学   2篇
物理学   11篇
  2023年   1篇
  2021年   2篇
  2020年   1篇
  2019年   3篇
  2018年   1篇
  2016年   6篇
  2015年   3篇
  2014年   1篇
  2013年   5篇
  2012年   1篇
  2011年   7篇
  2008年   2篇
  2007年   3篇
  2006年   1篇
  2005年   3篇
  2003年   1篇
  2002年   1篇
  1992年   1篇
  1982年   1篇
  1942年   1篇
  1939年   2篇
  1937年   1篇
  1930年   2篇
排序方式: 共有50条查询结果,搜索用时 0 毫秒
1.
The value of ECG-gated single-shot black-blood MR imaging for rapid visualization of the origin and course of the coronary arteries was investigated. The study population included 28 patients with known or suspected cardiac disease. ECG-gated single-shot black-blood MR acquisitions were acquired in the transverse, coronal, sagittal and LAO orientations, during free breathing and breath-holding. The origin of the left coronary artery was most frequently visualized in the coronal and LAO orientations and the origin of the right coronary artery was most frequently visualized in the LAO orientation. Overall, no significant difference was found for the visualization of the coronary artery segments and the overall image quality among acquisitions during breath-holding and free breathing. ECG-gated single-shot black-blood MR imaging (HASTE) appears to be a time-efficient and robust method for mapping of the entire coronary artery tree, without the need for breath-holding. The LAO orientation provides the most consistent visualization of the origins and major coronary artery segments.  相似文献   
2.
Effective denoising is vital for proper analysis and accurate quantitative measurements from magnetic resonance (MR) images. Even though many methods were proposed to denoise MR images, only few deal with the estimation of true signal from MR images acquired with phased-array coils. If the magnitude data from phased array coils are reconstructed as the root sum of squares, in the absence of noise correlations and subsampling, the data is assumed to follow a non central-χ distribution. However, when the k-space is subsampled to increase the acquisition speed (as in GRAPPA like methods), noise becomes spatially varying. In this note, we propose a method to denoise multiple-coil acquired MR images. Both the non central-χ distribution and the spatially varying nature of the noise is taken into account in the proposed method. Experiments were conducted on both simulated and real data sets to validate and to demonstrate the effectiveness of the proposed method.  相似文献   
3.
4.
5.
We describe the development and validation of a high-resolution screening (HRS) platform which couples gradient reversed-phase high-performance liquid chromatography (RP-HPLC) on-line to estrogen receptor α (ERα) affinity detection using fluorescence polarization (FP). FP, which allows detection at high wavelengths, limits the occurrence of interference from the autofluorescence of test compounds in the bioassay. A fluorescein-labeled estradiol derivative (E2-F) was synthesized and a binding assay was optimized in platereader format. After subsequent optimization in flow-injection analysis (FIA) mode, the optimized parameters were translated to the on-line HRS bioassay. Proof of principle was demonstrated by separating a mixture of five compounds known to be estrogenic (17β-estradiol, 17α-ethinylestradiol and the phytoestrogens coumestrol, coumarol and zearalenone), followed by post-column bioaffinity screening of the individual affinities for ERα. Using the HRS-based FP setup, we were able to screen affinities of off-line-generated metabolites of zearalenone for ERα. It is concluded that the on-line FP-based bioassay can be used to screen for the affinity of compounds without the disturbing occurrence of autofluorescence.  相似文献   
6.
7.
Herein, we describe the preparation of patterned photoresponsive hydrogels by using a facile method. This polymer‐network hydrogel coating consists of N‐isopropylacrylamide (NIPAAM), cross‐linking agent tripropylene glycol diacrylate (TPGDA), and a new photochromic spiropyran monoacrylate. In a pre‐study, a linear NIPAAM copolymer (without TPGDA) that contained the spiropyran dye was synthesised, which showed relatively fast photoswitching behaviour. Subsequently, the photopolymerisation of a similar monomer mixture that included TPGDA afforded freestanding hydrogel polymer networks. The light‐induced isomerisation of protonated merocyanine into neutral spiropyran under slightly acidic conditions resulted in macroscopic changes in the hydrophilicity of the entire polymer film, that is, shrinkage of the hydrogel. The degree of shrinkage could be controlled by changing the chemical composition of the acrylate mixture. After these pre‐studies, a hydrogel film with spatially modulated cross‐link density was fabricated through polymerisation‐induced diffusion, by using a patterned photomask. The resulting smooth patterned hydrogel coating swelled in slightly acidic media and the swelling was higher in the regions with lower cross‐linking densities, thus yielding a corrugated surface. Upon exposure to visible light, the surface topography flattened again, thus showing that a hydrogel coating could be created, the topography of which could be controlled by light irradiation.  相似文献   
8.
9.
10.
Surface-mounted metal–organic frameworks (SURMOFs) are crystalline films of MOFs and have garnered a great deal of attention in the past years. So far, thin-film MOF research has been mainly focused on the synthesis and the exploration of potential applications of these materials, while a detailed understanding of their growth is still lacking. In this report evidence is provided for the inter-grown nature of surface-mounted thin films of Zn-ZIF-8 (SURZIF-8; ZIF=zeolitic imidazolate framework). Two distinct SURZIF-8 thin films have been made through layer-by-layer (LBL) growth after applying 20 and 50 LBL cycles. They have been characterized with atomic force microscopy (AFM) and Raman micro-spectroscopy. A detailed analysis of the Raman mapping data, inter alia using principal component analysis (PCA), revealed the existence of phase boundaries within the 20-cycle thin film, while the 50-cycle thin film is chemically more homogeneous. To further analyze these chemical heterogeneities, density functional theory (DFT) calculations were performed of three theoretical models providing spectroscopic fingerprints of the molecular vibrations associated with the Zn-ZIF-8 thin films. Based on these calculations and the experimental data distinct vibrational markers indicative for the presence of defects sites were identified.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号