首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   319篇
  免费   4篇
  国内免费   4篇
化学   220篇
晶体学   6篇
力学   10篇
数学   50篇
物理学   41篇
  2022年   12篇
  2021年   8篇
  2020年   14篇
  2019年   12篇
  2018年   7篇
  2017年   5篇
  2016年   11篇
  2015年   13篇
  2014年   16篇
  2013年   33篇
  2012年   17篇
  2011年   23篇
  2010年   28篇
  2009年   20篇
  2008年   28篇
  2007年   19篇
  2006年   13篇
  2005年   10篇
  2004年   7篇
  2003年   9篇
  2002年   3篇
  2001年   1篇
  2000年   5篇
  1999年   2篇
  1997年   2篇
  1996年   3篇
  1995年   4篇
  1994年   1篇
  1993年   1篇
排序方式: 共有327条查询结果,搜索用时 15 毫秒
1.
The molecular structures and vibrational spectra of the three isomers of pyridinecarboxamide (picolinamide, nicotinamide, isonicotinamide) were calculated with the Density Functional Theory (DFT) method using the B3LYP function and the 6-31++G(d,p), Z2PolX, Z3PolX basis sets. The calculations were performed by using the Gaussian98W packet program set. The total energy distributions (TED) of the vibrational modes of these molecules were calculated by using the Scale 2.0 program and the vibrational modes of the molecules were determined. The Scaled Quantum Mechanical (SQM) method was used in the scaling procedure. In the experimental part of the study, the solid phase FT-IR and Micro Raman spectra of the three isomers of pyridinecarboxamide have been recorded in the range of 4000-650 and 1200-100 cm−1, respectively. The calculated wavenumbers were compared to the corresponding experimental values. As a result, the observed bands of the three isomers of pyridinecarboxamide were assigned with good accuracy.  相似文献   
2.
Journal of Thermal Analysis and Calorimetry - In the original publication of the article, the following equations has been incorrectly published. The corrected equations are given.  相似文献   
3.
Sargin  Idris  Karakurt  Serdar  Alkan  Sinan  Arslan  Gulsin 《Journal of fluorescence》2021,31(5):1461-1473

In the study, fluorescent imaging of live cells was performed using fluorescent carbon quantum dots derived from edible mushrooms species; Agaricus bisporus, Pleurotus ostreatus, and Suillus luteus as a fluorophore agent. Carbon quantum dots were synthesized through a facile and low-cost method based on microwave irradiation of dried mushroom samples in hydrogen peroxide solution under optimized conditions (microwave energy, solution type, duration of microwave treatment, amount of mushroom). Upon purification with centrifugation, microfiltration, and dialysis, the lyophilized carbon quantum dots were identified through UV–visible, fluorescence and FT-IR, X-ray photoelectron spectroscopy, X-ray diffraction, high-resolution transmission electron microscopy, and quantum yield calculation. Cell viability assessment of the carbon quantum dots was evaluated against human epithelial cell line PNT1A using the Alamar Blue Assay. In vitro fluorescence cell imaging studies demonstrated that the carbon dots could dynamically penetrate the cell membrane and nuclear membrane and localize in both the cytoplasm and the nucleus.

  相似文献   
4.
England DB  Eagan JM  Merey G  Anac O  Padwa A 《Tetrahedron》2008,64(6):988-1001
Tandem carbonyl ylide formation-1,3-dipolar cycloaddition of α-diazo N-acetyl-tetrahydro-β-carbolin-1-one derivatives occur efficiently in the presence of a dirhodium catalyst to afford bimolecular cycloadducts in high yield. The Rh(II)-catalyzed reaction also takes place intramolecularly to give products derived from trapping of the carbonyl ylide dipole with a tethered alkene. The power of the intramolecular cascade sequence is that it rapidly assembles a pentacyclic ring system containing three new stereocenters and two adjacent quaternary centers stereospecifically in a single step and in high yield.  相似文献   
5.
Somer G  Sezer S  Doğan M  Kalaycı S  Sendil O 《Talanta》2011,85(3):1461-1465
A new borate ion selective electrode using solid salts of Ag3BO3, Ag2S and Cu2S has been developed. Detailed information is provided concerning the composition, working pH and conditioning of the electrode. An analytically useful potential change occurred from 1 × 10−6 to 1 × 10−1 M borate ion. The slope of the linear portion was 31 ± 2 mV/10-fold changes in borate concentration. The measurements were made at constant ionic strength (0.1 M NaNO3) and at room temperature. The effect of Cl, Br, NO3, SO=4, H2PO4 anions and K+, Na+, Cu2+, Ag+, Ca2+ cations on borate response is evaluated and it was found that only Ag+ had a small interference effect. The lifetime of the electrode was more than two years, when used at least 4-5 times a day, and the response time was about 20-30 s. Borate content in waste water of borax factory, tap water of a town situated near to the borax factory and city tap water far from these mines were also determined. The validation was made with differential pulse polarography for the same water sample, and high consistency was obtained.  相似文献   
6.
New bis(NHC)-Pd complexes were synthesized and characterized by elemental analysis, 1H NMR, 13C NMR, and IR spectroscopy. The reaction of Pd(OAc)2 and bis(benzimidazolium) salts in DMSO gave the monomeric palladium complex in which the N-heterocyclic carbene was bound to the metal centre. The crystal and molecular structure of the cis-dibromo{1,1′-di[2,3,4,5,6-pentamethylbenzyl]-3,3′-butylenedibenzimidazol-2,2′-diylidene}-palladium(II) complex was determined by single-crystal X-ray diffraction. The activity of the Pd(II) complexes in the direct arylation of benzothiazole with arylbromides was investigated. A preliminary catalytic study showed that these bis(NHC)-Pd complexes were highly active in the direct arylation of benzothiazole with arylbromides.  相似文献   
7.
A slurry sampling method has been developed for the determination of Pb in marine plankton by ETAAS using a freshwater plankton certified reference material (CRM 414). Slurries were prepared in 1–3% m/v range with 1% v/v HNO3 by ultrasonic agitation for 5 min. The effects of several chemical modifiers, including Ir(NO3)2, Mg(NO3)2, Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, and Mg(NO3)2 + NH4H2PO4, were investigated for the stabilization of Pb during thermal pretreatment. Lead in slurries was effectively stabilized up to 1000 °C with Ir, Pd and Pd + Mg modifiers among which Pd + Mg provided the best results with complete atomization at 1850 °C. Firings in the presence of Ir were, problematic due to ash formation inside the atomizer. Water, dilute HNO3 and HF were examined as suspension medium. Dilute HNO3 (1–2% v/v) proved to be advantageous over water as it afforded extraction of Pb from plankton almost quantitatively in 5 min agitation. Hydrofluoric acid was the least suitable medium. Increasing HF concentration up to 5% v/v resulted in inaccuracy and substantial background absorption. Fast-heating furnace method provided comparable accuracy and precision to that of conventional-heating in slurries of CRM 414. Detection limits and characteristic masses were, respectively, 0.49 μg L− 1 and 32 pg for the conventional method and 0.62 μg L− 1 and 37 pg for the fast-heating method. However, fast-heating approach suffered from distorted peaks at high temperatures and incomplete pyrolysis of matrix at lower temperatures. Analysis of marine plankton samples for Pb was performed by using the conventional furnace program. The results showed a high correlation with those obtained by solution ICP-MS. Differences were statistically insignificant within 95% confidence interval.  相似文献   
8.
Four new Hofmann–3-phenylpropylamine (3PPA) type complexes with chemical formulae M(3PPA)2Ni(CN)4 (M = Ni, Co, Cd, and Pd) have been prepared and their vibrational spectra are reported in the region of 4000–60 cm−1. The vibrational bands arising from 3PPA ligand molecule, the polymeric sheet and metal–ligand bands of the compounds are assigned. The thermal behaviour of these complexes is also provided using the DTA and TGA along with the magnetic susceptibility data. The results indicate that the monodentate 3PPA ligand molecule bonds to the metal atom of |M–Ni(CN)4| polymeric layers and hence the compounds are similar in structure to Hofmann-type complexes.  相似文献   
9.
A method has been developed for the determination of 23 elements in marine plankton in which inductively coupled plasma (ICP) source mass spectrometry (MS) was used to quantify the elements in the solution after digestion in a mixture of hydrofluoric and nitric acids in sealed PTFE vessels in a microwave field. The procedure was validated by the analysis of a standard reference soil (SRM 2709 San Joaquin Soil) and a standard reference fresh water plankton (CRM 414). The method was applied to the analysis of several marine plankton samples grown under controlled conditions including several whose growth media had been enriched with selenium. Matrix induced signal suppressions and instrumental drift were corrected by internal standardization. The suitabilities of germanium, indium, rhodium, scandium and yttrium as internal standard elements were evaluated. Neither scandium nor yttrium could be used due to the presence of these elements in the samples, germanium was used for the determination of As, Co, Cu, Fe, Ni, Se, Si and Zn, indium was used for Al, Ba, Ca, Eu, Sr, and Tl, and rhodium was used for Cd, Cr, Hg, Mg, Pb, Sb, Sn, and V. For Al, Ca, Cr, Cu, Fe, Mg, Mn, Ni, Si, Sr, V, and Zn internal standardization did not completely compensate for the suppressive effect of the heavier elements and the solutions were diluted. However, for As, Ba, Cd, Co, Eu, Hg, Pb, Sb, Se, Sn and T1, it was possible to obtain accurate results despite the 35-40% suppression in the signals. Isobaric overlap was only a problem in the cases of 42Ca and 78Se; 44Ca and 77Se, respectively, were used. Memory effects were only observed with Hg for which a nitric acid-sodium chloride solution was the most effective wash-out solution. The marine plankton samples were able to tolerate a higher concentration of Hg as the selenium concentration increased.  相似文献   
10.
Arslan Z 《Talanta》2005,65(5):1326-1334
A method is developed for determination of trace elements, including Ag, As, Cd, Co, Cr, Cu, Mn, Ni, Se, Tl and Zn, in fish otoliths by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Hydrofluoric acid was used to precipitate calcium resulting from acid dissolution of otolith calcium carbonate. Initial acidity of the sample solution influenced the precipitation efficiency of calcium fluoride. Up to 99.5% of Ca was precipitated in solutions that contained less than 2% (v/v) HNO3. Recoveries of the elements obtained from spiked artificial otolith solutions were between 90 and 103%. Stabilization of the elements within the ETV cell was achieved with 0.3 μg Pd/0.2 μg Rh chemical modifier that also afforded optimum sensitivity for multielement determination. The method was validated by the analysis of a fish otolith reference material (CRM) of emperor snapper, and then applied to the determination of the trace elements in otoliths of several fish species captured in Raritan Bay, New Jersey. Results indicated that fish physiology and biological processes could influence the levels of Cu, Mn, Se and Zn in the otoliths of fish inhabiting a similar aqueous environment. Otolith concentrations of Cr and Ni did not show any significant differences among different species. Concentrations for Ag, As, Cd, Co and Tl were also not significantly different, but were very low indicating low affinity of otolith calcium carbonate to these elements.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号