This work describes development of a flow injection (FI) system for determination of iodide, based on the chemiluminescence (CL) reaction between iodine and luminol. Iodide in the sample zone is oxidized to iodine. Employment of a gas-diffusion (GD) unit allows for selective detection of the generated CL (425 nm). Preliminary results showed for concentrations of less than 2 mg L−1, that signals were irreproducible and that the calibration was not linear.In order to solve these problems, a method of ‘membrane conditioning’ was investigated, in which iodide stream was continuously merged with oxidant to generate I2 that conditioned the GD membrane and tubing. This minimized surface interaction between the active surface and the I2 generated from the samples, thus improving both precision and sensitivity. By employing membrane conditioning, it has been possible to reliably detect concentrations down to 0.1 mg L−1.At the optimized condition, an excellent linear calibration (r2 = 0.999) was obtained from 0.1 to 1.0 mg L−1. The method was successfully applied to determine iodide in some pharmaceutical products such as potassium iodide tablets and a liquid patent medicine. However, for vitamin tablets, ascorbic acid was found to interfere seriously by causing a negative signal.  相似文献   
2.
Dioscorealide B is a pharmacologically active compound from the rhizome of the Thai medicinal plant Dioscorea membranacea. Here, we demonstrated that in vitro treatment of dioscorealide B resulted in a cytotoxic effect on MCF-7 human breast cancer cells (IC50 = 2.82 microM). To determine whether this compound induces apoptosis in MCF-7, the Annexin V assay was performed. The data showed that the number of apoptotic cells were increased 7-12 folds over that of the control cells after treatment with various concentrations of dioscorealide B (3, 6 and 12 microM) for 24 hours. Dioscorealide B-induced apoptosis was associated with modulation of the multidomain Bcl-2 family members Bax, Bak and Bcl-2. After treatment with 3 microM dioscorealide B, acceleration of the level of proapoptotic proteins Bax and Bak were observed at 6 hours and 12 hours, respectively, while the decrease in the expression of antiapoptotic protein Bcl-2 was observed 3 hours after the treatment. These effects of dioscorealide B might result in the activation of caspase-8, -9 and -7, which lead to apoptosis in MCF-7 cells. Taken together, the results of this study provide evidence that dioscorealide B possesses an antitumor property against human breast cancer cells and thus provide the molecular basis for the further development of dioscorealide B as a novel chemotherapeutic agent for breast cancer treatment.  相似文献   
3.
An in‐house flow‐injection capillary electrophoresis with capacitively coupled contactless conductivity detection method was developed for the direct measurement of colistin in pharmaceutical samples. The flow injection and capillary electrophoresis systems are connected by an acrylic interface. Capillary electrophoresis separation is achieved within 2 min using a background electrolyte solution of 5 mM 2‐morpholinoethanesulfonic acid and 5 mM histidine (pH 6). The flow‐injection section allows for convenient filling of the capillary and sample introduction without the use of a pressure/vacuum manifold. Capacitively coupled contactless conductivity detection is employed since colistin has no chromophore but is cationic at pH 6. Calibration curve is linear from 20 to 150 mg/L, with a correlation coefficient (r2) of 0.997. The limit of quantitation is 20 mg/L. The developed method provides precision, simplicity, and short analysis time.  相似文献   
4.
A simple and rapid method based on micro‐liquid chromatography using a synthetic monolithic capillary column was developed for determination of iohexol in human serums, a marker to evaluate the glomerular filtration rate. A hydrophilic methacrylic acid‐ethylene dimethacrylate monolith provided excellent selectivity and efficiency for iohexol with separation time of 3 min using a mobile phase of 40:60 v/v 50 mM phosphate buffer pH 5/methanol. Four serum protein removal, methods using perchloric acid, 50% acetonitrile, 0.1 M zinc sulfate, and centrifuge membrane filter were examined. The method of zinc sulfate was chosen due to its simplicity, compatibility with the mobile phase system, nontoxicity, and low cost. Interday calibration curves were conducted over iohexol concentrations range of 2–500 mg/L (R2 = 0.9997 ± 0.0001) with detection limit of 0.44 mg/L. Intra‐ and interday precisions for peak area and retention time were less than 2.8 and 1.4%, respectively. The method was successfully applied to serum samples with percent recoveries from 102 to 104. The method was applied to monitor released iohexol from healthy subject. Compared with the commercially available reversed‐phase high‐performance liquid chromatography method, the presented method provided simpler chromatogram, faster separation with higher separation efficiency and much lower sample and solvent consumption.  相似文献   
5.
An analytical procedure for the determination of phenyltin compounds in environmental sample waters was studied. Chromatography of mono-, di- tri-phenyltin (MPT, DPT and TPT) was performed on a reversed-phase C18 column with the mobile phase comprising methanol/10−2 M H3PO4 (80:20 v/v) at pH 3 and UV detection at 214 nm. To enhance the sensitivity of the detection system, the post-column reaction between morin or 3-hydroxyflavone and phenyltin compounds was formed before fluorescence detection. Several parameters affecting the fluorescence intensity were studied systematically, including the optimum condition for the post-column reagent that was also compatible with the eluent. The parameters concerned in this study were the pH, the percentage of Triton X-100, the ratio of fluorigenic reagent to phenyltin compounds and the amount of methanol in the eluent. Detection limits before the preconcentration process were in the region of 1.5 ppb for TPT and 150–250 ppb for MPT and DPT, respectively. Utilizing solid-phase extraction on a C18 cartridge for sample clean-up as well as preconcentration successfully reduced the detection limit of TPT to the level of ng dm−3 and can be applied to seawater analysis. Recovery in the range 95.0–98.0% was obtained by developing the optimum elution profile in the preconcentration step. © 1998 John Wiley & Sons, Ltd.  相似文献   
6.
7.
CE methods with capacitively coupled contactless conductivity detection (C4D) were developed for the enantiomeric separation of the following stimulants: amphetamine (AP), methamphetamine (MA), ephedrine (EP), pseudoephedrine (PE), norephedrine (NE) and norpseudoephedrine (NPE). Acetic acid (pH 2.5 and 2.8) was found to be the optimal background electrolyte for the CE‐C4D system. The chiral selectors, carboxymethyl‐β‐cyclodextrin (CMBCD), heptakis(2,6‐di‐O‐methyl)‐β‐cyclodextrin (DMBCD) and chiral crown ether (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid (18C6H4), were investigated for their enantioseparation properties in the BGE. The use of either a single or a combination of two chiral selectors was chosen to obtain optimal condition of enantiomeric selectivity. Enantiomeric separation of AP and MA was achieved using the single chiral selector CMBCD and (hydroxypropyl)methyl cellulose (HPMC) as the modifier. A combination of the two chiral selectors, CMBCD and DMBCD and HPMC as the modifier, was required for enantiomeric separation of EP and PE. In addition, a combination of DMBCD and 18C6H4 was successfully applied for the enantiomeric separation of NE and NPE. The detection limits of the enantiomers were found to be in the range of 2.3–5.7 μmol/L. Good precisions of migration time and peak area were obtained. The developed CE‐C4D method was successfully applied to urine samples of athletes for the identification of enantiomers of the detected stimulants.  相似文献   
8.
Arsenic (As) in soils and hair collected from schools in Ron Phibun district, Nakhon Si Thammarat province, Thailand, where former tin mining operation were located, was determined by hydride generation atomic absorption spectrophotometry. The relationship between As content in soils and hair with distance from secured landfill was also investigated. Soil and hair samples were collected from 6 schools in summer (February) and rainy season (July). For soils, silt+clay (<45 µm) fraction and sand (45 µm–2 mm) fraction were analyzed. The average concentrations of arsenic in soils during summer (21.70 ± 16.79 mg/kg) and rainy season (22.45 ± 14.17 mg/kg) were at the same concentration level. The average arsenic content in hair samples was 2.24 ± 0.05 mg/kg in rainy season which was higher than 1.05 ± 0.04 mg/kg in summer. It was found that arsenic contents in hair and soils are correlated with the distance from the secured landfill. Most importantly, a positive relationship between arsenic content in hair and soil was obtained for rainy season, which indicated that arsenic in soil corresponded to arsenic in hair. The cancer risk from soils ranged from 4.48 × 10?7 to 2.06 × 10?6 indicating low carcinogenic risk to school children.  相似文献   
9.
This work describes the development of a telemetric system in conjunction with a computer sound card for recording of signals. For signal transmission, a transmission wireless microphone was utilized, making the telemeter compatible with the sound card normally equipped inside a personal computer. The developed telemeter is a low-cost apparatus capable of remote monitoring. With the sampling rate of 10 Hz, 100% accuracy was obtained up to a distance of 30 m. The precision was good (%RSD = 0.03-0.09), with relatively low noise. The effective signal range was from 0 to 2 V, with approximately 1100 working steps (greater than 10 bit A/D). The telemetric system was shown to be suitable for wireless recording of outputs from spectrophotometer and pH meter. Potential applications in chemical analysis were demonstrated.  相似文献   
10.
The electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2 = 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s−1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2 = 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets.  相似文献   