排序方式: 共有24条查询结果,搜索用时 31 毫秒
1.
Yallouz AV Calixto de Campos R Paciornik S 《Fresenius' Journal of Analytical Chemistry》2000,368(5):461-465
A non instrumental method for the semiquantitative determination of mercury in fish is described. The sample is acid digested and the mercury vapor released after chemical reduction with SnCl2. The mercury vapor is then collected on a detecting paper covered with an emulsion of Cu2I2, 3% carboxymethylcellulose and MgCl2 as moistener agent. The colored Cu2[HgI4] complex is formed and the color intensity is proportional to the mercury concentration in the original sample. Parameters such as sample mass/digestion solution volume ratio, emulsion composition, paper covering technique, carrier gas flow were investigated. Comparative studies using CVAAS and digital color analysis after scanning the papers confirmed the applicability of the method to real samples. 相似文献
2.
Marli Roehsig Daniela Mendes Louzada de Paula Sidnei Moura Edna Maria de Albuquerque Diniz Mauricio Yonamine 《Journal of separation science》2010,33(14):2115-2122
A number of fatty acid ethyl esters (FAEEs) have recently been detected in meconium samples. Several of these FAEEs have been evaluated as possible biomarkers for in utero ethanol exposure. In the present study, a method was optimized and validated for the simultaneous determination of eight FAEEs (ethyl laurate, ethyl myristate, ethyl palmitate, ethyl palmitoleate, ethyl stearate, ethyl oleate, ethyl linoleate and ethyl arachidonate) in meconium samples. FAEEs were extracted by headspace solid‐phase microextraction. Analyte detection and quantification were carried out using GC‐MS operated in chemical ionization mode. The corresponding D5‐ethyl esters were synthesized and used as internal standards. The LOQ and LOD for each analyte were <150 and <100 ng/g, respectively. The method showed good linearity (r2>0.98) in the concentration range studied (LOQ – 2000 ng/g). The intra‐ and interday imprecision, given by the RSD of the method, was lower than 15% for all FAEEs studied. The validated method was applied to 63 authentic specimens. FAEEs could be detected in alcohol‐exposed newborns (>600 ng/g cumulative concentration). Interestingly, FAEEs could also be detected in some non‐exposed newborns, although the concentrations were much lower than those measured in exposed cases. 相似文献
3.
Silva SG Morales-Rubio A de La Guardia M Rocha FR 《Analytical and bioanalytical chemistry》2011,401(1):365-371
A new procedure for spectrofluorimetric determination of free and total glycerol in biodiesel samples is presented. It is
based on the oxidation of glycerol by periodate, forming formaldehyde, which reacts with acetylacetone, producing the luminescent
3,5-diacetyl-1,4-dihydrolutidine. A flow system with solenoid micro-pumps is proposed for solution handling. Free glycerol
was extracted off-line from biodiesel samples with water, and total glycerol was converted to free glycerol by saponification
with sodium ethylate under sonication. For free glycerol, a linear response was observed from 5 to 70 mg L−1 with a detection limit of 0.5 mg L−1, which corresponds to 2 mg kg−1 in biodiesel. The coefficient of variation was 0.9% (20 mg L−1, n = 10). For total glycerol, samples were diluted on-line, and the linear response range was 25 to 300 mg L−1. The detection limit was 1.4 mg L−1 (2.8 mg kg−1 in biodiesel) with a coefficient of variation of 1.4% (200 mg L−1, n = 10). The sampling rate was ca. 35 samples h−1 and the procedure was applied to determination of free and total glycerol in biodiesel samples from soybean, cottonseed,
and castor beans. 相似文献
4.
Lisiani Ritter Eduarda Possa Larissa Bergoza Fabiana Agostini Sidnei M. Silva Leandro Tasso 《Biomedical chromatography : BMC》2020,34(11):e4977
Clindamycin is used for infections caused by Gram-positive and Gram-negative anaerobic pathogens and Gram-positive aerobes. Propionibacterium acnes is an important opportunistic microorganism of the human skin and is related to prostatitis. An LC–electrospray ionization–quadrupole time-of-flight–MS method was validated for determining clindamycin concentrations in plasma and prostate microdialysate. Clindamycin separation was carried out on a C18 column at 0.5 mL/min. The mobile phase employed gradient elution of formic acid and methanol. A mass spectrometer was operated in positive electrospray ionization mode to monitor ion 425.1784 and 253.1152 for clindamycin and cimetidine (internal standard), respectively. Linearity was obtained at 0.5–10.0 μg/mL (plasma) and 0.05–1.0 μg/mL (microdialysate) with coefficients of determination ≥0.999. The intra- and inter-day precision (coefficient of variation - CV%) values were ≤13.83% and 12.51% for plasma, respectively, and ≤10.90% and 9.35% for microdialysate, respectively. The accuracy was between 90.82% and 108.25% for plasma, and 96.97% and 106.98% for microdialysate. The present method was fully validated and applied to investigate clindamycin concentrations in both plasma and prostate by microdialysis in Wistar rats (80 mg/kg, intravenous). Because the penetration of antibiotics into the prostate may be restricted, this method allows us to investigate the prostate concentrations of clindamycin for the first time. 相似文献
5.
A method for automatic classification of the shape of graphite particles in cast iron is proposed. In a typical supervised classification procedure, the standard charts from the ISO-945 standard are used as a training and validation population. Several shape and size parameters are described and used as discriminants. A new parameter, the average internal angle, is proposed and is shown to be relevant for accurate classification. The ideal parameter sets are determined, leading to validation success rates above 90%. The classifier is then applied to real cast iron samples and provides results that are consistent with visual examination. The method provides classification results per particle, different from the traditional per field chart comparison methods. The full procedure can run automatically without user interference. 相似文献
6.
Stacia E. Dancsak Sidnei G. Silva Joaquim A. Nóbrega Bradley T. Jones George L. Donati 《Analytica chimica acta》2014
High levels of sodium and potassium can be present in biodiesel fuel and contribute to corrosion, reduced performance and shorter engine lifetime. On the other hand, trace amounts of chromium and vanadium can increase the emission of pollutants during biodiesel combustion. Sample viscosity, immiscibility with aqueous solutions and high carbon content can compromise biodiesel analyzes. In this work, tungsten filaments extracted from microscope light bulbs are used to successively decompose biodiesel's organic matrix, and atomize and excite the analytes to determine sodium, potassium, chromium and vanadium by tungsten coil atomic emission spectrometry (WCAES). No sample preparation other than simple dilution in methanol or ethanol is required. Direct analysis of 10-μL sample aliquots using heating cycles with less than 150 s results in limits of detection (LOD) as low as 20, 70, 70 and 90 μg kg−1 for Na, K, Cr and V, respectively. The procedure's accuracy is checked by determining Na and K in a biodiesel reference sample and carrying out spike experiments for Cr and V. No statistically significant differences were observed between reference and determined values for all analytes at a 95% confidence level. The procedure was applied to three different biodiesel samples and concentrations between 6.08 and 95.6 mg kg−1 for Na and K, and between 0.22 and 0.43 mg kg−1 for V were obtained. The procedure is simple, fast and environmentally friendly. Small volumes of reagents, samples and gases are used and no residues are generated. Powers of detection are comparable to other traditional methods. 相似文献
7.
Sidnei G. Silva George L. Donati Luana N. Santos Bradley T. Jones Joaquim A. Nóbrega 《Analytica chimica acta》2013
Cobalt is used as chemical modifier to improve sensitivity and minimize matrix effects in Cr determinations by tungsten coil atomic emission spectrometry (WCAES). The atomizer is a tungsten filament extracted from microscope light bulbs. A solid-state power supply and a handheld CCD-based spectrometer are also used in the instrumental setup. In the presence of 1000 mg L−1 Co, WCAES limit of detection for Cr (λ = 425.4 nm) is calculated as 0.070 mg L−1; a 10-fold improvement compared to determinations without Co modifier. The mechanism involved in such signal enhancement is similar to the one observed in ICP OES and ICP-MS determinations of As and Se in the presence of C. Cobalt increases the population of Cr+ by charge transfer reactions. In a second step, Cr+/e− recombination takes place, which results in a larger population of excited-state Cr atoms. This alternative excitation route is energetically more efficient than heat transfer from atomizer and gas phase to analyte atoms. A linear dynamic range of 0.25–10 mg L−1 and repeatability of 3.8% (RSD, n = 10) for a 2.0 mg L−1 Cr solution are obtained with this strategy. The modifier high concentration also contributes to improving accuracy due to a matrix-matching effect. The method was applied to a certified reference material of Dogfish Muscle (DORM-2) and no statistically significant difference was observed between determined and certified Cr values at a 95% confidence level. Spike experiments with bottled water samples resulted in recoveries between 93% and 112%. 相似文献
8.
Marcos A.P Martins Claudio M.P Pereira Nilo E.K Zimmermann Wilson Cunico Sidnei Moura Paulo Beck Nilo Zanatta Helio G Bonacorso 《Journal of fluorine chemistry》2003,123(2):261-265
A series of 10 heterocycles was obtained from the reaction of 1,1,1-trifluoro-4,4-diethoxy-3-buten-2-one and 1,1,1,2,2-pentafluoro-4,4-diethoxy-3-penten-2-one with different dinucleofiles (hydrazine, methyl hydrazine, hydroxylamine and sodium cyanide). The pyrazoles, 4,5-dihydroisoxazoles and pyrrolidinones polyfluoroalkyl substituted were obtained in moderate to good yields under mild conditions. 相似文献
9.
Pereira Bruna Á. de Bastos Alcione V. Teixeira Wystan K. O. e Silva Sidnei Moura Flores Alex F. C. Flores Darlene C. 《Molecular diversity》2017,21(4):1021-1026
Molecular Diversity - An elegant, efficient, and highly regioselective approach for the synthesis of novel methyl 5-amino-3-(methylthio)-1-differently substituted-1H-pyrazole-4-carboxylates is... 相似文献
10.
Hobuss CB Venzke D Pacheco BS Souza AO Santos MA Moura S Quina FH Fiametti KG Vladimir Oliveira J Pereira CM 《Ultrasonics sonochemistry》2012,19(3):387-389
This work describes the ultrasound-assisted synthesis of saturated aliphatic esters from synthetic aliphatic acids and either methanol or ethanol. The products were isolated in good yields after short reaction times under mild conditions. 相似文献