首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   108篇
  免费   4篇
化学   75篇
力学   9篇
数学   19篇
物理学   9篇
  2022年   2篇
  2021年   2篇
  2020年   3篇
  2019年   4篇
  2018年   7篇
  2017年   8篇
  2016年   9篇
  2015年   10篇
  2014年   8篇
  2013年   9篇
  2012年   12篇
  2011年   6篇
  2010年   6篇
  2009年   5篇
  2008年   5篇
  2007年   3篇
  2006年   4篇
  2004年   2篇
  2002年   2篇
  1998年   1篇
  1993年   2篇
  1992年   2篇
排序方式: 共有112条查询结果,搜索用时 15 毫秒
1.
The electrocatalytic oxidation of aspirin has been investigated on a nickel oxide-modified nickel electrode in alkaline solution. The process of oxidation and its kinetics have been investigated by using cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy techniques and also steady-state polarization measurements. Voltammetric studies have indicated that in the presence of aspirin, the anodic peak current of low-valence nickel species increases, followed by a decrease in the corresponding cathodic current. This indicates that aspirin was oxidized on the redox mediator immobilized on the electrode surface via an electrocatalytic mechanism. The rate constant of the catalytic oxidation of aspirin and the electron transfer coefficient have been found to be 1.15×105 cm3 mol−1s−1 and 0.49, respectively. Impedance measurements show that aspirin is diffused into the bulk of the modifier film, and the oxidation process of aspirin occurs in the bulk of nickel oxide film. It has been shown that by using this modified electrode, aspirin can be determined with a detection limit of 4.8×10−5 and successfully applied for determination of aspirin in tablet.  相似文献   
2.
3.
The present study deals with preparation and optimization of a novel chitosan hydrogel‐based matrix by suspension cross‐linking method for controlled release of Depo‐Medrol. The controlled release of Depo‐Medrol for effective Rheumatoid arthritis disease has become an imperative field in the drug delivery system. In this context, it was intended to optimize loading circumstances by experimental design and also study the release kinetics of Depo‐Medrol entrapped in the chitosan matrix in order to obtain maximal efficiency for drug loading. The optimum concentrations of chitosan (2.5 g), glutaraldehyde (3.05 μL) and Depo‐Medrol (0.1 mg) were set up to achieve the highest value of drug loaded and the most sustained release from the chitosan matrix. In vitro monitoring of drug release kinetic using high‐performance liquid chromatography showed that 73% of the Depo‐Medrol was released within 120 min, whereas remained drug was released during the next 67 h. High correlation between first‐order and Higuchi's kinetic models indicates a controlled diffusion of Depo‐Medrol through the surrounding media. Moreover, recovery capacity >82% and entrapment efficiency of 58–88% were achieved under optimal conditions. Therefore, the new synthesized Depo Medrol–chitosan is an applicable appliance for arthritis therapy by slow release mechanism. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
4.
Journal of Radioanalytical and Nuclear Chemistry - In this work, graphene oxide (GO) and (aminomethyl)phosphonic acid–Graphene oxide (AMPA–GO) adsorbents were prepared by the modified...  相似文献   
5.
Jabbari  A.  Mohasefi  J. B. 《Nonlinear dynamics》2019,95(4):3177-3191
Nonlinear Dynamics - A three-party-authenticated key agreement (3PAKA) scheme allows two participants to establish shared secure session key (3SK) via trusted server over a public network....  相似文献   
6.
A novel Fe3O4/graphene/polypyrrole nanocomposite has been successfully synthesised via a simple chemical method and applied as a new magnetic solid-phase extraction (MSPE) sorbent for the separation and pre-concentration of trace amounts of Pt (IV) in environmental samples followed by flame atomic absorption spectrometric (FAAS) detection. The nanocomposite has been characterised by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Fourier transform infrared (FTIR) spectroscopy. Seven important parameters, affecting the extraction efficiency of Pt (IV), including pH, adsorption time, desorption solvent type and concentration, desorption time, elution volume and sample volume, were investigated. Under the optimised conditions, the calibration graph was linear in the range of 50–1500 μg L?1 (R = 0.993). The detection limit and pre-concentration factor (PF) for Pt (IV) were found to be 16 μg L?1 and 112.5, respectively. Under the optimised solid-phase extraction (SPE) conditions, the adsorption isotherm and the adsorption capacity of the nanocomposite for Pt (IV) were studied. Pt (IV) adsorption equilibrium data were fitted well to the Langmuir isotherm and the maximum adsorption capacity of the magnetic sorbent was calculated from the Langmuir isotherm model as 416.7 mg g?1. The precision of the method was studied as intraday and interday variations. A relative standard deviation percentage (RSD%) value less than 3.0 indicates that the method is precise. Also, the accuracy of the method was tested by the analysis of the standard reference material (NIST SRM 2556) and by recovery measurements on spiked real samples. It was also shown that the optimised method was suitable for the analysis of trace amounts of Pt (IV) in roadside soil, tap water and wastewater samples.  相似文献   
7.
Mehdinia  Ali  Shoormeij  Zeynab  Jabbari  Ali 《Mikrochimica acta》2017,184(5):1529-1537
Microchimica Acta - The authors describe a magnetic nanoadsorbent consisting of magnetite nanoparticles coated first with titanium dioxide and then with polypyrrole (PPy). It is shown to be a...  相似文献   
8.
The electrocatalytic oxidation of acyclovir (Zovirax) on two different copper-based electrodes: copper microparticles- and copper nanoparticles-modified carbon paste electrodes (denoted as micro-CPE and nano-CPE, respectively) was voltammetrically investigated. In the voltammogram recorded using micro-CPE, a single anodic oxidation peak appeared, while nano-CPE resulted in two overlapped anodic peaks. The anodic currents were related to the electrocatalytic oxidation of acyclovir via the electrogenerated active species of Cu(III) with an EC’ mechanism. Acyclovir was oxidized with higher rates at low potentials on nano-CPE compared to micro-CPE. This was related to the nanosize effect of copper nanoparticles. The constants of the electrocatalytic oxidation process and the diffusion coefficient of acyclovir were reported. A sensitive and time-saving determination procedure was developed for the analysis of acyclovir and the corresponding analytical parameters were reported. The proposed amperometric method was applied to the analysis of commercial pharmaceutical products (tablets and topical cream) and the results were in good agreement with the declared values.  相似文献   
9.
The electrooxidation of dextromethorphan on a composite constructed with carbon nanotube–ionic liquid–carbon microparticles was investigated by cyclic voltammetry in a 100 mM phosphate buffer solution, pH 7.40. In the voltammograms, an irreversible diffusion-controlled anodic peak appeared. The diffusion coefficient of dextromethorphan, the electron-transfer coefficient, and the standard rate constant of the electrooxidation process were found to be 3.45?×?10?6 cm2 s?1, 0.65, and 1.67?×?10?3 cm s?1, respectively. A sensitive and timesaving determination procedure was developed for the analysis of dextromethorphan, and the corresponding analytical parameters were reported. Using this method, dextromethorphan was determined with an LOD and LOQ of 8.81 and 29.36 μM in a linear range of 2.5?×?10?4 to 3.3?×?10?3 M, respectively. The proposed amperometric method was successfully applied to the analysis of commercial pharmaceutical products (syrup and oral drop), and the results were in good agreement with the declared values.  相似文献   
10.
In this paper, the local radial point interpolation meshless method (LRPIM) is used for the analysis of two‐dimensional potential flows, based on a local‐weighted residual method with the Heaviside step function as the weighting function over a local subdomain. Trial functions are constructed using radial basis functions. The present method is a truly meshless method based only on a number of randomly located nodes. Integration over the subdomains requires only a simple integration cell to obtain the solution. No element matrix assembly is required and no special treatment is needed to impose the essential boundary conditions. The novelty of the paper is the use of a local Heaviside weight function in the LRPIM, which does not need local domain integration and integrations only on the boundary of the local domains are needed. Effects of the sizes of local subdomain and interpolation domain on the performance of the present method are investigated. The behavior of shape parameters of multiquadrics has been systematically studied. Two numerical tests in groundwater and fluid flows are presented and compared with closed‐form solutions and finite element method. The results show that the use of a local Heaviside weight function in the LRPIM is highly accurate and possesses no numerical difficulties. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号