共查询到20条相似文献,搜索用时 0 毫秒
1.
Gotti R El-Hady DA Andrisano V Bertucci C El-Maali NA Cavrini V 《Electrophoresis》2004,25(16):2830-2837
A cyclodextrin-modified micellar electrokinetic chromatographic (CD-MEKC) method for the determination of the most important potential impurities of methotrexate (MTX): 2,4-diamino-6-(hydroxymethyl)pteridine, aminopterine hydrate, 4-[N-(2-amino-4-hydroxy-6-pteridinylmethyl)-N-methylamino] benzoic acid, 4-[N-(2,4-diamino-6-pteridinylmethyl)-N-methylamino] benzoic acid, and the distomer D-MTX is presented. The MEKC separation of these compounds was optimized by applying a step-by-step approach. The addition of beta-CD to a conventional MEKC system, based on sodium dodecyl sulfate (SDS) as surfactant, showed to be essential for the enantioresolution of racemic MTX as well as for the separation of the achiral impurities. To achieve high-resolution factor between the peaks adjacent to the main component (L-MTX), as required in the analysis of related impurities, the separation conditions were stressed; in particular, the addition of methanol to the CD-MEKC system resulted in a very effective choice. Under the optimized final conditions (100 mM SDS and 45 mM beta-CD in a mixture of 50 mM borate buffer, pH 9.30-methanol (75:25 v/v)), the method was validated showing a general adequate accuracy (93-106% recovery) in the determination of L-MTX related substances at the impurity level of 0.12% w/w with a relative standard deviation (RSD)% lower than 8% (n = 4). The method was successfully applied to the analysis of pharmaceuticals (tablets and injections) which showed to contain the distomer D-MTX as major impurity and aminopterine hydrate as a further related substance in the commercial tablets. 相似文献
2.
In this study, enantioseparations of five phenothiazines in cyclodextrin (CD)-modified micellar electrokinetic chromatography (MEKC) were investigated using a citrate buffer containing tetradecyltrimethylammonium bromide (TTAB) as a cationic surfactant at low pH. Beta-cyclodextrin (beta-CD) and hydroxylpropyl-beta-CD (HP-beta-CD) were selected as chiral selectors. The results indicate that the separation window is greatly enlarged by beta-CD concentration and that the separability and selectivity of phenothiazines are remarkably influenced by the concentrations of both beta-CD and TTAB, as well as buffer pH. The interaction of thioridazine with beta-CDs is considerably reduced in the presence of TTAB micelles due to competitive complexation of thioridazine with TTAB micelles, which is pH-dependent. As a result, effective enantioseparation of thioridazine is simultaneously achievable with that of trimeprazine and promethazine or ethopropazine in MEKC with addition of either beta-CD or HP-beta-CD, respectively, to a micellar citrate buffer containing TTAB at pH 3.5. Better enantioresolution of thioridazine in MEKC than in capillary zone electrophoresis can be obtained. 相似文献
3.
A rapid and effective method was developed for the chiral separation of raltitrexed (RD) enantiomers by carboxymethyl-beta-cyclodextrin
(CM-β-CD)-modified micellar electrokinetic chromatography (MEKC). Optimization of conditions including the type and concentration
of the chiral selector, concentration of sodium dodecyl sulfate (SDS), pH and concentration of the background electrolyte
(BGE), capillary temperature, and applied voltage was investigated. The enantiomers of raltitrexed could be separated with
satisfactory resolution and linear response by using 75 mM Tris-phosphate at pH 8.0 containing 30 mM SDS and 8 mM CM-β-CD
as buffer system. Furthermore, the usefulness of this method was demonstrated in a purity test of a real synthetic drug sample.
Figure Chiral separation of raltitrexed by CM-β-CD MEKC was optimized and applied to test the purity of a synthetic drug sample 相似文献
4.
5.
Determination of oleanolic acid and ursolic acid in cornel by cyclodextrin-modified micellar electrokinetic chromatography 总被引:2,自引:0,他引:2
A cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) method was established for the determination of oleanolic acid and ursolic acid in cornel. The two components were separated in the running buffer of 40 mmol/L sodium borate containing 5% methanol, 25 mmol/L SDS and 15 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD). The applied voltage was 24 kV. The wavelength of detection was 200 nm. The temperature was kept at 25 C. Cinnamic acid was used as the internal standard. The analytical performance of the method was tested with respect to linearity, precision and recovery. The calibration curves were linear in the range of 10.15-243.6 microg/mL, r=0.9993 (oleanolic acid) and 10.07-241.7 microg/mL, r=0.9994 (ursolic acid); the intra-day precision (RSD) was less than 3.7% (oleanolic acid) and 4.1% (ursolic acid); the inter-day precision (RSD) was less than 4.2% (oleanolic acid) and 4.9% (ursolic acid). The limits of detection were 1.6 microg/mL for both components. The method proved to be sensitive, rapid, accurate and suitable for the determination of oleanolic acid and ursolic acid in cornel. 相似文献
6.
A micellar electrokinetic chromatographic (MEKC) method was developed for the quantification of mesalazine or 5-aminosalicylic acid (5-ASA) and its major impurities 3-aminosalicylic acid, salicylic acid, sulfanilic acid and 4-aminophenol. The optimisation of the experimental conditions was carried out considering some important requirements: resolution, reproducibility, detection limits of 0.1% (m/m) or less, short total analysis time. Preliminary investigations employing sodium dodecyl sulfate (SDS) as surfactant did not lead to the necessary resolution of the studied compounds; the addition of tetrabutylammonium bromide (TBAB) to the SDS micellar system resulted in the complete separation of all the compounds. The effects on the separation by several parameters such as TBAB concentration, SDS concentration, background electrolyte pH and concentration, were evaluated. Using a fused-silica capillary (8.5 cm effective length) complete analysis was obtained in a very short time. Under the optimised final conditions [120 mM 3-(cyclohexylamino)-2-hydroxy-1-propanesulfonic acid buffer, pH 10.20, 65 mM SDS in the presence of 55 mM TBAB and 5% methanol] the method was validated for specificity, precision, linearity, limits of detection and quantitation, and robustness: the 5-ASA related impurities can be quantified at least at the 0.1% (m/m) level. 相似文献
7.
Doxorubicinol (DOXol) is a human metabolite of the chemotherapy agent doxorubicin (DOX), and is associated with dose-dependent cardiotoxicity and decreased drug efficacy. Due to the structural similarities and equal molecular charges of DOXol and DOX, their electrophoretic separation is commonly ineffective. A method for separating and detecting DOX and DOXol, as well as two DOXol enantiomers, was established using cyclodextrin-modified micellar electrokinetic capillary chromatography with laser-induced fluorescence detection. Differential DOXol production was detected in a DOX-sensitive and resistant pair of cell lines, with a 0.08 +/- 0.01 fmol limit of detection. 相似文献
8.
Herrero-Martínez JM Fernández-Martí M Simó-Alfonso E Ramis-Ramos G 《Electrophoresis》2001,22(3):526-534
Octyl- and nonylphenol ethoxylates (OPEs and NPEs) with different numbers of ethoxy units (average values: n = 10 and N = 40 for OPEs, and n = 10 for NPEs) were separated by micellar electrokinetic chromatography under positive polarity using an 80 mM borate buffer of pH 8.5 containing sodium deoxycholate (SDC) or sodium cholate (SC). When sodium dodecyl sulfate (SDS) was added to the background electrolyte (BGE) in the absence of the bile salt, a single peak at a migration time longer than that of the EOF was obtained. Substituting the SDS by a bile salt, the homologues were resolved. At the same bile salt concentration, resolution between the homologues was higher with SDC than using SC. Optimum resolution between consecutive homologues was obtained with 50 mM SDC. In the presence of low or moderate amounts of acetonitrile or n-propanol, the background line improved significantly, whereas resolution may increase or decrease slightly. We propose a procedure for the determination of OPEs and NPEs with optimum resolution between the homologues as well as a modified procedure with improved selectivity for the single-run determination of other absorbing nonionic, cationic, and anionic (such as linear alkylbenzene sulfonates) surfactants in industrial and household cleaning products and its application to a variety of samples. The detection limit was ca. 28 microg x mL(-1) of total NPE (n = 10), and peak area repeatabilities at 50 microg x mL(-1) were 1.7% (intraday) and 5.6% (interday). 相似文献
9.
A micellar electrokinetic chromatography (MEKC) method was developed for the quantitation of polyphenols (+)-catechin and (-)-epicatechin (catechin monomers) and the methylxanthine theobromine in Theobroma cacao beans. Owing to the poor stability of catechin monomers in alkaline conditions, a 50 mM Britton-Robinson buffer at a pH 2.50 was preferred as the background electrolyte. Under these conditions, the addition of hydroxypropyl-beta-cyclodextrin (HP-beta-CD) at a concentration of 12 mM to the SDS micellar solution (90 mM), resulted in a cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) endowed with two peculiar advantages compare to the conventional MEKC: (i) strong improvement of separation of the most important phytomarkers of T. cacao and (ii) enantioselectivity toward (+/-)-catechin. In particular, separation of methylxanthines (theobromine and caffeine), procyanidin dimers B1 and B2, and catechins (epicatechin and catechin) was obtained simultaneously to the enantioseparation of racemic catechin within 10min. The enantioselectivity of the method makes it suitable in evaluation of possible epimerisation at the C-2 position of epicatechin monomer potentially occurring during heat processing and storage of T. cacao beans. The extraction procedure of the phytomarkers from the beans was approached using ultrasonic bath under mild conditions optimized by a multivariate strategy. The method was validated for robustness, selectivity, sensitivity, linearity, range, accuracy and precision and it was applied to T. cacao beans from different countries; interestingly, the native enantiomer (+)-catechin was found in the beans whereas, for the first time we reported that in chocolate, predominantly (-)-catechin is present, probably yielded by epimerisation of (-)-epicatechin occurred during the manufacture of chocolate. 相似文献
10.
Separation of nine important alkyl methylbutyl- and isobutylamides (known as alkamides) obtained from Echinacea purpurea extracts was investigated by using cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC). Hydrophobic alkamides interact strongly with the micelles from the most common surfactants used in MEKC and this lead to predominant partition of the analytes into the micellar phase, resulting in poor resolution. The addition of neutral CDs to the alkaline (10 mM phosphate buffer pH 8.0) micellar system of sodium dodecyl sulfate (SDS), sodium cholate (SC) and sodium deoxycholate (SDC) was found to improve the separation of the studied alkamides. Among the several combinations surfactant/CD, three different systems showed to be particularly effective: SDS/hydroxypropyl-beta-CD (110 mM/100 mM) and SC/heptakis (2, 3, 6-tri-O-methyl)-beta-CD (200 mM/40 mM) which provided a complete separation of the studied compounds, and SDC/heptakis (2, 6-di-O-methyl)-beta-CD. The importance of appropriate surfactant vs. CD concentration ratio as well as that of total concentration of both surfactant and CD was considered. The optimization of the separation was performed by focussing the need for a rapid separation of nine alkamides diagnostically useful to define the fingerprint of Echinacea species. 相似文献
11.
On-line preconcentration and chiral separation of propiconazole by cyclodextrin-modified micellar electrokinetic chromatography 总被引:1,自引:0,他引:1
A method for the chiral separation of propiconazole using cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) with hydroxypropyl-gamma-cyclodextrin (HP-gamma-CD) as chiral selector is reported. The use of a mixture of 30 mM HP-gamma-CD, 50mM SDS, methanol-acetonitrile 10%:5% (v/v) in 25 mM phosphate buffer solution was able to separate two enantiomeric pairs of propiconazole. Stacking- and sweeping-CD-MEKC under neutral pH (pH 7) and under acidic condition (pH 3.0) were used as two on-line preconcentration methods to increase detection sensitivity of propiconazole. Good repeatabilities in the migration time, peak area and peak height were obtained in terms of relative standard deviation (RSD). A sensitivity enhancement factor of 100-fold was achieved using sweeping-CD-MEKC at acidic pH. This is the first report on the separation of two pairs of propiconazole enantiomers and all the enantiomers of fenbuconazole and tebuconazole using sweeping-CD-MEKC. The limit of detection (S/N=3) for the three triazole fungicides ranged from 0.09 to 0.1 microg/mL, which is well below the maximum residue limits (MRL) set by Codex Alimentarius Commission (CAC). Combination of solid-phase extraction (SPE) pretreatment and sweeping-CD-MEKC procedure was applied to the determination of selected triazole fungicides in grapes samples spiked at concentration 10-40 times lower than the MRL established by the CAC. The average recoveries of the selected fungicides in spiked grapes samples were good, ranging from 73% to 109% with RSD of 9-12% (n=3). 相似文献
12.
Krystian Purgat Kamila Borowczyk Robert Zakrzewski Rafa Gowacki Pawe Kubalczyk 《Biomedical chromatography : BMC》2019,33(10)
A simple, fast, sensitive and reproducible micellar electrokinetic chromatography (MEKC)–UV method for the determination of nikethamide (NKD) in human urine and pharmaceutical formulation has been developed and validated. The method exhibits high trueness, good precision, short analysis time and low reagent consumption. NKD is an organic compound belonging to the psychoactive stimulants used as an analeptic drugs. The proposed analytical procedure consists of few steps: dilution of urine or drug in distilled water, centrifugation for 2 min (12,000 g ), separation by MEKC and ultraviolet‐absorbance detection of NKD at 260 nm. The background electrolyte used was 0.035 mol/L pH 9 borate buffer with the addition of 0.05 mol/L sodium dodecyl sulfate and 6.5% ACN. Effective separation was achieved within 5.5 min under a voltage of 21 kV (~90 μA) using a standard fused‐silica capillary (effective length 51 cm, 75 μm i.d.). The determined limit of detection for NKD in urine was 1 μmol/L (0.18 μg/mL). The calibration curve obtained for NKD in urine showed linearity in the range 4–280 μmol/L (0.71–49.90 μg/mL), with R2 0.9998. The RSD of the points of the calibration curve varied from 5.4 to 9.5%. The analytical procedure was successfully applied to analysis of pharmaceutical formulation and spiked urine samples from healthy volunteers. 相似文献
13.
A method was proposed for the simultaneous determination of steroids of the endo- and exogeneous origin with the use of micellar electrokinetic chromatography, which provides the determination of residual medicines in biological fluids and the control of medication efficiency at different steroidogenesis abnormalities. The introduction of a macrocyclic addition of β-cyclodextrin (from 1 to 6 mM) into a buffer electrolyte solution (25 mM phosphoric acid, 20 mM sodium dodecyl sulfate, 4.5 mM urea, pH 2.5) or into a sample solution decreases the detection limit by a factor of 20–200. 相似文献
14.
Determination of antitubercular drugs by micellar electrokinetic capillary chromatography (MEKC) 总被引:4,自引:0,他引:4
Acedo-Valenzuela MI Espinosa-Mansilla A Muñoz De La Peña A Cañada-Cañada F 《Analytical and bioanalytical chemistry》2002,374(3):432-436
A method for the determination of isoniazid (ISO), pyrazinamide (PYR) and rifampicin (RIF) in pharmaceutical products, by micellar electrokinetic capillary chromatography (MEKC) with ultraviolet detection is described. The influence of pH, concentration of surfactants, buffer and organic solvents, over the separation were studied as experimental variables. The optimal separation was carried out at 30 degrees C and 20 kV, using a 40 mM borate buffer and 100 mM sodium dodecylsulphate (SDS) adjusted to pH 8.5. Under these conditions, the analysis is accomplished in about 8 min. The method was applied to the determination of these compounds in different pharmaceuticals with good results when compared with a reference liquid chromatographic (LC) method. 相似文献
15.
Enantioseparation of dopa and related compounds by cyclodextrin-modified microemulsion electrokinetic chromatography 总被引:2,自引:0,他引:2
A chiral microemulsion electrokinetic chromatography method has been developed for the enantiomeric separation of 3,4-dihydroxyphenylalanine (dopa), its precursors phenylalanine and tyrosine, and the structurally related substance methyldopa. The separations were achieved using an oil-in-water microemulsion, which consisted of the oil-compound ethyl acetate, the surfactant sodium dodecylsulfate (SDS), the co-surfactant 1-butanol, the organic modifier propan-2-ol and 20mM phosphate buffer pH 2.5 or 2.0 as aqueous phase. For enantioseparation sulfated beta-cyclodextrin was added. The resolution of each racemate was optimized by varying the concentration of the buffer and all components of the microemulsion. Enantioseparation could be achieved for dl-dopa, dl-phenylalanine and dl-tyrosine within 13min with a resolution of 4.3, 3.1 and 3.3, respectively, and for methyldopa in 17min (Rs: 1.4). The established methods allowed the detection of dopa, phenylalanine, tyrosine and methyldopa with a limit at 0.5, 1.0, 0.2 and 2.0mug/ml. 相似文献
16.
Xiaoyu Shang Zhuobin Yuan 《Analytica chimica acta》2002,456(2):183-188
A cyclodextrin-modified micellar electrokinetic chromatographic method was established to determine five anthraquinone derivatives and a distyrene derivative in Rhubarb. The six components were successfully separated by using the mixed micellar system consisting of 20 mmol/l SC and 20 mmol/l STC with 15 mmol/l β-CD in the BGE of 20 mmol/l borax buffer (pH 11) in less than 20 min. Effect of SC and STC concentrations, pH of BGE and concentration of β-CD on the separation was studied. The analytical performance of the method was discussed in terms of linearity response, precision, detection limits, quantitation limits and recoveries. The method developed was applied to the determination of three commercial Rhubarb samples. The results obtained agreed with those of the reported documents. 相似文献
17.
In this study both native and chemically modified cyclodextrins (CDs) were investigated as buffer additives to improve the micellar electrokinetic capillary chromatography (MEKC) separation of endogenous bioanalytes in human urine. The following CDs were investigated: alpha, beta, gamma-CDs; hydroxypropyl-alpha-CD, hydroxypropyl-beta-CD, methylated beta-CD, sulphated beta-CD, sulphobutyl ether-beta-CD and hydroxypropyl-gamma-CD. The separations were compared to MEKC without additives. The best improvement in peak resolution and separation of urine components was observed with the sulphated beta-CD. A four-factor three-level full factorial design study was conducted on voltage, temperature, pH and sulphated beta-CD molarity. The optimum conditions were 25 mM sodium tetraborate, pH 9.5, 75 mM sodium dodecyl sulphate (SDS) and 6.25 mM sulphated beta-CD and were able to resolve 70 peaks from a urine pool in 12 min. These optimum conditions have been successfully applied to a number of clinical samples. 相似文献
18.
Xin Liu 《Analytica chimica acta》2004,512(2):297-304
A micellar electrokinetic capillary chromatography (MEKC) method with laser-induced fluorescence detection (LIF) was developed for analyzing three phosphoamino acids including phosphotyrosine (P-Tyr), phosphoserine (P-Ser), and phosphothreonine (P-Thr). 3-(2-Furoyl)quinoline-2-carboxaldehyde (FQ), a fluorogenic dye, was employed for derivatization of these phosphoamino acids. Results indicated that the complete baseline resolution of each phosphoamino acid was obtained within 10 min, using 20 mmol l−1 sodium borate buffer (pH 9.35) containing 20 mmol l−1sodium deoxycholate (SDC) and 10 mmol l−1 Brij35. Other common amino acids, especially Glu and Asp, did not disturb the assay of these phosphoamino acids. There was a linear relationship between the peak area for analyte and its concentration, with correlation coefficients in the range of 0.9966-0.9996. The concentration detection limits (signal-to-noise = 3) for P-Tyr, P-Ser, and P-Thr were 10, 40, and 75 nmol l−1, respectively. The developed method was successfully applied for determining phosphoamino acids in the hydrolysis sample of a phosphorylated protein kinase. 相似文献
19.
A fast and highly selective micellar electrokinetic capillary chromatography (MEKC) method for quantitative analysis of vancomycin and related impurities is described. Among the tested surfactants, cetyltrimethylammonium chloride (CTAC) offered the best selectivity. Another important parameter, which strongly influenced the selectivity, was buffer pH. It was found that the selectivity increased with buffer pH decreasing from 9 to 5. Using Tris-phosphate buffer containing CTAC, satisfactory separation could be obtained in the pH range from 5.0 to 5.5. Excellent repeatability in terms of migration time and peak area could be obtained when the capillary was carefully washed between two runs. In order to obtain optimal conditions and to evaluate the method robustness, a central composite experimental design was carried out. The optimal conditions were: 44 cm length of fused-silica capillary with 50 microm ID, 120 mM Tris-phosphate buffer (pH 5.2) containing 50 mM CTAC, -15 kV applied voltage, UV detection at 210 nm, and a column temperature of 25 degrees C. Under the optimal conditions, more than 20 peaks could be separated within 8 min. The method has a linearity range from 0.004 to 1.2 mg/ml (concentration of vancomycin B, active component). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.4 microg/mL vancomycin, equivalent to 0.3 microg/mL vancomycin B (0.04%) and 1.1 microg/mL vancomycin, equivalent to 0.9 microg/mL vancomycin B (0.1%), respectively. 相似文献
20.
Okamoto H Uetake A Tamaya R Nakajima T Sagara K Ito Y 《Journal of chromatography. A》2000,888(1-2):299-308
Cyclodextrin-modified micellar electrokinetic chromatography was applied to determine simultaneously 11 active ingredients in ophthalmic solutions. All the ingredients were successfully separated by using the mixed carrier system containing sodium dodecyl sulfate with beta-cyclodextrin and tetrabutylammonium phosphate. The effects of the cyclodextrin type on selectivity were also examined. Excellent separation of the all ingredients was obtained by the use of dimethyl-beta-cyclodextrin. The established method was validated and confirmed to be applicable to the determination of the active ingredients in a commercial ophthalmic solution. These results suggest that capillary electrophoresis can be applied to the quantitative analysis as well as qualitative analysis in pharmaceuticals. 相似文献