首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Reveal Salmonella Enteritidis (SE) is a lateral flow-based immunodiagnostic assay used for rapid detection of Salmonella enterica serovar Enteritidis from pooled shell eggs and environmental samples. This assay uses highly specific antibodies to accurately detect S. Enteritidis. Studies were conducted to compare the performance of this test against reference procedures for detection of S. Enteritidis from both pooled shell eggs and environmental samples. Pooled shell eggs were inoculated with low levels ofS. Enteritidis and were enriched according to the procedure prescribed by the U.S. Food and Drug Administration. Uninoculated samples were included in each trial. Reveal SE exhibited 100% sensitivity and 100% specificity in comparison to the reference method in all trials. An abbreviated 48 h/(no hold) enrichment procedure was also developed and validated for detection ofS. Enteritidis from pooled shell egg samples. This shortened enrichment procedure can be used in conjunction with the Reveal SE test and offers a significant enrichment time savings of 96 h. Chi-square analysis revealed that there was no significant difference between the abbreviated Reveal method and the reference procedure for detection ofS. Enteritidis from pooled shell egg samples. Out of 245 natural drag swabs screened internally, only three samples tested Reveal SE positive and were confirmed by the reference procedure, resulting in 100% sensitivity and 100% specificity. An external laboratory screened 147 poultry house environmental samples and obtained 35 Reveal SE confirmed positives for Reveal SE sensitivity of 100% and specificity of 90%. Inoculation trials with drag swabs resulted in 96% sensitivity and 100% specificity. Thus, these data demonstrate that Reveal SE is a highly sensitive and specific assay for the detection of S. Enteritidis from both pooled shell eggs and environmental samples.  相似文献   

2.
The SDIX RapidChek Listeria F.A.S.T. test system was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) cultural reference method for the detection of Listeria species on stainless steel, plastic, rubber, and painted concrete. The SDIX method uses a proprietary RapidChek Listeria enrichment media for a one-step, 24-40 h enrichment at 30 degrees C, and detects Listeria on an immunochromatographic lateral flow device in 10 min. Different Listeria species were used to spike each of the environmental surfaces. Environmental surfaces were spiked at levels ranging from 50 to 400 CFU/surface (1 in.2 swabs for painted concrete, 4 in.(2) for sponge). A total of 120 spiked samples were tested by the SDIX method at 24 and 40 h and the cultural reference method. Total confirmed positives were 49, 54, and 48 for the SDIX 24 h method, the SDIX 40 h method, and the USDA-FSIS cultural reference method, respectively. Nonspiked samples from all environmental surfaces were reported as negative for Listeria spp. by all methods. The overall Chi square was 0.017 (P = 0.104) and 0.611 (P= 0.566) after a 24 and 40 h enrichment, respectively, indicating that the test method was equivalent in performance to the reference method at both enrichment times. The SDIX method was evaluated for the detection of 50 Listeria and 35 non-Listeria bacterial strains. All 50 Listeria strains were detected by the method (100% sensitivity). Five out of 35 non-Listeria species gave light test signals when grown in nonselective broth culture and tested undiluted. However, when grown in the RapidChek Listeria F.A.S.T. proprietary media, only one bacterial strain (Staphylococcus aureus) was detected, giving a very low test signal (97% specificity). The method was shown to be robust toward several alterations in testing and storage conditions.  相似文献   

3.
Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.  相似文献   

4.
In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.  相似文献   

5.
Singlepath Salmonella is an immunochromatographic (lateral flow) assay for the presumptive qualitative detection of Salmonella spp. in food. The AOAC Performance-Tested Method study evaluated Singlepath Salmonella as an effective method for the detection of Salmonella spp. in the following selected foods: dried skimmed milk, black pepper, dried pet food, desiccated coconut, cooked peeled frozen prawns, raw ground beef, and raw ground turkey. When the foods were inoculated with Salmonella spp. at levels ranging from low [0.23-1.08 colony forming units (CFU)/25 g] to high (2.3-6.0 CFU/25 g), a Chi-square value of 0.9 indicated that there was no significant difference between Singlepath Salmonella and the ISO 6579:2002 reference method. Singlepath Salmonella gave a false-positive rate of 7.3% and a false-negative rate of 2.5%. For the inclusivity study, all 105 Salmonella serovars reacted with Singlepath Salmonella. For the exclusivity study, 58 non-Salmonella spp. were tested. There were no cross-reactions with Singlepath Salmonella from these strains.  相似文献   

6.
The clonal analysis of a diverse collection of Salmonella Enteritidis indicates that most strains belong to a single multilocus genotype (i.e., ET-3) regardless of phage type, geographic origin, or time of isolation that spanned over 2 decades (1978 to 2004). Attachment and invasion assays, however, indicate that, among ET-3 isolates, there is a distinct invasive bacterial subpopulation that is more readily recovered from eggs and clinical cases in humans than from chicken cecal samples. These observations support the hypothesis that the specialized ability of S. Enteritidis to infect the avian reproductive tract and contaminate eggs has been critical in its emergence as a frequent cause of human illness.  相似文献   

7.
Cost-effective and rapid monitoring of Salmonella in the meat production chain can contribute to food safety. The objective of this study was to validate an easy-to-use pre-PCR sample preparation method based on a simple boiling protocol for screening of Salmonella in meat and carcass swab samples using a real-time PCR method. The protocol included incubation in buffered peptone water, centrifugation of an aliquot, and a boiling procedure. The validation study included comparative and interlaboratory trials recommended by the Nordic Organization for Validation of Alternative Microbiological Methods (NordVal). The comparative trial was performed against a reference method (NMKL 187, 2007) and a PCR method previously approved by NordVal with a semiautomated magnetic bead-based DNA extraction step using 122 artificially contaminated samples. The LOD was found to be 3.0, 3.2, and 3.4 CFU/sample for the boiling, magnetic bead-based, and NMKL 187 methods, respectively. When comparing the boiling method with the magnetic beads, the relative accuracy (AC), relative sensitivity (SE), and relative specificity (SP) were 98, 102, and 98%, respectively (Cohen's kappa index 0.95). When comparing results obtained by the boiling to the culture-based method, the AC, SE, and SP were found to be 98, 102, and 98%, respectively (kappa index 0.93). In the interlaboratory trial including valid results from 11 laboratories, apart from two false-positive samples by the boiling method combined with PCR, no deviating results were obtained (SP, SE, and AC were 100, 95, and 97%, respectively). This test is under implementation by the Danish meat industry, and can be useful for screening of large number of samples in the meat production, especially for fast release of minced meat with a short shelf life.  相似文献   

8.
New enrichment protocols are described for use with a DNA hybridization (DNAH) method for detection of Salmonella spp. in select foods. GeneQuence Salmonella, in its original version, utilized a 3-stage enrichment of minimum 42 h duration. New 2-stage procedures of 24-28 h duration are described for raw poultry, raw beef, pasteurized egg products, milk chocolate, and dry pet food. In the validation study described here, a total of 345 samples were tested by the abbreviated DNAH method in parallel with either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedures. Results showed an overall sensitivity for the DNAH method of 97.1% (false-negative rate 2.9%). There were no false-positive results by the DNAH method; therefore the specificity was 100%. Overall agreement between the DNAH and reference culture methods was 98.5%. There were no significant differences in performance between the DNAH and reference methods for any of the foods tested as determined by Chi-square analysis. It is recommended that the DNAH method be subjected to AOAC collaborative study.  相似文献   

9.
The BAX System PCR assay for Salmonella detection in foods was previously validated as AOAC Research Institute (RI) Performance Tested Method (PTM) 100201. New studies were conducted on beef and produce using the same media and protocol currently approved for the BAX System PCR assay for E. coli O157:H7 multiplex (MP). Additionally, soy protein isolate was tested for matrix extension using the U.S. Food and Drug Administration-Bacteriological Analytical Manual (FDA-BAM) enrichment protocols. The studies compared the BAX System method to the U.S. Department of Agriculture culture method for detecting Salmonella in beef and the FDA-BAM culture method for detecting Salmonella in produce and soy protein isolate. Method comparison studies on low-level inoculates showed that the BAX System assay for Salmonella performed as well as or better than the reference method for detecting Salmonella in beef and produce in 8-24 h enrichment when the BAX System E. coli O157:H7 MP media was used, and soy protein isolate in 20 h enrichment with lactose broth followed by 3 h regrowth in brain heart infusion broth. An inclusivity panel of 104 Salmonella strains with diverse serotypes was tested by the BAX System using the proprietary BAX System media and returned all positive results. Ruggedness factors involved in the enrichment phase were also evaluated by testing outside the specified parameters, and none of the factors examined affected the performance of the assay.  相似文献   

10.
The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.  相似文献   

11.
A multilaboratory study was conducted to compare performance of the GeneQuence DNA hybridization (DNAH) method incorporating new 24 h enrichment protocols and reference culture procedures for detection of Salmonella spp. in select foods. Six food types (raw ground turkey, raw ground beef, dried whole egg, milk chocolate, walnuts, and dry pet food) were tested by the DNAH method and by the culture methods of either the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) or the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM). Fifteen laboratories participated in the study. Four of the foods tested (raw ground turkey, dried whole egg, milk chocolate, and dry pet food), showed no statistically significant differences in performance between the DNAH method and the reference procedure as determined by Chi square analysis. Sensitivity rates for the DNAH method ranged from 92 to 100%. The DNAH method, with the specific enrichment protocol evaluated, was found to be ineffective for detection of Salmonella spp. in walnuts. For raw ground beef, results from one trial showed a statistically significant difference in performance, with more positives obtained by the reference method. However, evidence suggests that the difference in the number of positives was likely due to lack of homogeneity of the test samples rather than to DNAH method performance.  相似文献   

12.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay (TSVIA) with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (7th Ed.). Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. The TECRA method was evaluated using both Rappaport-Vassiliadis R10 (RV(R10)) and tetrathionate (TT) broths for selective enrichment. M broth cultures arising from each of the 2 selective enrichment broths were tested in the TSVIA using 2 individual wells, one for each selective broth, and a single well to test the pooled selective enrichment broths. The results for the pooled enrichment broths were reported elsewhere. This study presents the results for the use of single enrichment broths, i.e., RV(R10) only or TT only, with the TSVIA. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for either RV(R10) or TT used as a single enrichment broth for the TSVIA with that for the reference method.  相似文献   

13.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM 7th Ed.). Three food types (milk powder, black pepper, and soy flour) were analyzed in Australia, and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for the TECRA method with that for the reference method. The new enrichment procedure for the TECRA method has been adopted First Action by AOAC INTERNATIONAL.  相似文献   

14.
The BIOLINE Salmonella ELISA Test for Salmonella spp., which is a rapid, easy, and convenient assay was evaluated for use in detecting Salmonella in foods and feeds. Each food matrix or feed was artificially contaminated with low levels of Salmonella. Twenty different matrixes were studied and 20 different Salmonella strains from a broad variety of serogroups (B, C, D, E, F, G, H, I, M, O, P, and U) were used. The EUSA Test kit detected levels as low as 1 cfu/25 g sample with at least 4 of the 20 matrixes tested. The test kit is applicable to all sample types tested. The BIOLINE Salmonella ELISA Test kit has been granted AOAC-RI performance tested status.  相似文献   

15.
Reveal for Salmonella test system.   总被引:2,自引:0,他引:2  
The Reveal for Salmonella (RSS) test system is a presumptive qualitative test that detects the presence of Salmonella organisms in foods within 21 h total testing time, allowing the user to release negative products 24 h earlier than when using other rapid test kits. Foods are enriched with a proprietary resuscitation medium called Revive and then selectively enriched with either Selenite Cystine or Rappaport-Vassiliadis selective media. The enriched culture is used to inoculate the RSS detection device, which initiates a lateral flow through a reagent zone containing anti-Salmonella antibodies conjugated to colloidal gold particles that capture antigens present in the culture. The antigen-antibody complex migrates farther and is captured by an additional anti-Salmonella antibody, causing the colloidal gold to precipitate and form a visual line, indicating a positive result. A procedural control line also will form regardless of the presence of Salmonella organisms to indicate the test is working properly. Existing AOAC Official Methods for Salmonella organisms require a 48 h enrichment before testing. Hence, a food product has to be held before release, adding extra cost to the company and the consumer. The RSS test system was evaluated by quantitative spiking studies. Although AOAC encourages inclusion of naturally contaminated foods, almost all microbiological AOAC validation studies have been performed with artificially contaminated foods for absolute control over the study. The RSS test system is designed to test many food types for Salmonella organisms and has a limit of detection of 5-10 colony-forming units (cfu)/25 g with a false-negative rate of < 1% and a false-positive rate of < 5.0%. It showed an 81% overall agreement with the traditional procedure of the U.S. Department of Agriculture's Food Safety Inspection Service.  相似文献   

16.

The presence of Salmonella in natural freshwater and drinking water is a leading cause of intestinal illness all over the world; thus, the detection of Salmonella in water is of great importance to public health. The objective of this study is to develop a rapid screening method for the detection of Salmonella enterica serovar Enteritidis in water involving surface-enhanced Raman spectroscopy (SERS), aptamers, and filtration. SERS offers a great alternative to traditional methods of pathogen detection, with a simplified detection assay and shortened detection time. The specific capturing and labeling of Salmonella Enteritidis are realized by a specific single-stranded DNA aptamer, which is modified with an additional chain of adenine and fluorescein (FAM) and used as presence/absence indicator of Salmonella Enteritidis. By incorporating a vacuum filtration system, bacterial cells recognized by the specific aptamer are concentrated onto a membrane. With additional filtration of gold nanoparticles, the aptamer signals were captured and used to construct a SERS mapping indicating the presence and absence of target bacterial strains with potential quantitative capability. The specificity of the method was validated by using other strains of bacteria such as Escherichia coli and Listeria monocytogenes. The sensitivity of the method goes down to 103 CFU/mL for 1 mL of sample with a total detection and analyzing time within 3 h. This study demonstrates the capability of the filtration-based SERS platform for detecting Salmonella Enteritidis in various aqueous matrices such as distilled water and rinsing water from fresh produce with high selectivity and sensitivity.

Graphical abstract

  相似文献   

17.
Seafood, including fish, shrimp, clam, crab, mussel, oyster, lobster, squid, octopus, and cuttlefish samples, was used to compare the recovery of Salmonella serovars by different selective enrichment and isolation media. The samples were selectively enriched in Rappaport-Vassiliadis (RV) broth and tetrathionate broth (TT), followed by selective isolation on Hektoen enteric (HE) agar, xylose lysine desoxycholate (XLD) agar, bismuth sulfite (BS) agar, and Brilliant Green (BG) agar media. Of 443 seafood samples analyzed, 108 were found to be contaminated with Salmonella. The role of selective enrichment in Salmonella spp. recovery with RV medium was distinctly high (70%) compared to TT broth (30%). The selective enrichment in RV broth followed by selective isolation on XLD, HE, BS, and BG agar recovered Salmonella at levels of 56, 41, 28, and 16%, respectively. Similarly, after enrichment in TT broth, XLD and HE agars recovered 27 and 23% respectively. The recovery of Salmonella with enrichment in TT followed by isolation on BS and BG was abysmally low at 4.6 and 5%, respectively. There was no significant difference (P > 0.05) in the recovery of Salmonella using the combinations of XLD and HE media with selective enrichment in RV broth. However, performance difference (P < 0.05) was observed in the recovery when BS and BG with RV, and XLD, HE, BS, and BG agars with TT broth were used. The present study showed that the combination of RV with XLD was the most efficient media for isolation of Salmonella from seafood when compared to other isolation media combinations.  相似文献   

18.
A collaborative study was conducted to compare the VIDAS Salmonella (SLM) with Rappaport-Vassiliadis (RV) method for detection of Salmonella in foods to the current standard method presented in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) and the culture method presented in AOAC's Official Methods of Analysis. The VIDAS SLM with RV method uses tetrathionate broth in combination with RV medium in place of selenite cystine broth for selective enrichment, thereby eliminating the hazardous waste issue for laboratories. Twenty five laboratories participated in the evaluation, each testing one or more of 8 test products: nonfat dry milk, dried egg, soy flour, lactic casein, milk chocolate, raw ground pork, raw ground turkey, and raw peeled shrimp. Results of the study showed no significant differences in the numbers of confirmed positive samples with the VIDAS SLM with RV procedure and the BAM/AOAC culture procedure. The VIDAS SLM with RV method was effective for rapid detection of Salmonella in foods. It is recommended that AOAC INTERNATIONAL modify the VIDAS Salmonella SLM procedure to include the RV method.  相似文献   

19.
Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time-to-results compared to traditional culture methods. In this study, the MicroSEQ real-time PCR system was evaluated for detection of Salmonella spp. in 10 different food matrixes following the AOAC Research Institute's Performance Tested Method validation program. In addition, the performance of the MicroSEQ system was evaluated for the detection of Salmonella in peanut butter as a part of the Emergency Response Validation Program sponsored by the AOAC Research Institute. The system was compared to the ISO 6579 reference method using a paired-study design for detecting Salmonella spp. in raw ground beef, raw chicken, raw shrimp, Brie cheese, shell eggs, cantaloupe, chocolate, black pepper, dry infant formula, and dry pet food. For the peanut butter study, the system was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures using an unpaired-study design. No significant difference in performance was observed between the MicroSEQ Salmonella spp. detection system and the corresponding reference methods for all 11 food matrixes. The MicroSEQ system detected all Salmonella strains tested, while showing good discrimination against detection of an exclusivity panel of 30 strains, with high accuracy.  相似文献   

20.
As part of a standardization project, an interlaboratory trial including 15 laboratories from 13 European countries was conducted to evaluate the performance of a noproprietary polymerase chain reaction (PCR)-based method for the detection of Salmonella on artificially contaminated chicken rinse and pig swab samples. The 3 levels were 1-10, 10-100, and 100-1000 colony-forming units (CFU)/100 mL. Sample preparations, including inoculation and pre-enrichment in buffered peptone water (BPW), were performed centrally in a German laboratory; the pre-PCR sample preparation (by a resin-based method) and PCR assay (gel electrophoresis detection) were performed by the receiving laboratories. Aliquots of BPW enrichment cultures were sent to the participants, who analyzed them using a thermal lysis procedure followed by a validated Salmonella-specific PCR assay. The results were reported as negative or positive. Outlier results caused, for example, by gross departures from the experimental protocol, were omitted from the analysis. For both the chicken rinse and the pig swab samples, the diagnostic sensitivity was 100%, with 100% accordance (repeatability) and concordance (reproducibility). The diagnostic specificity was 80.1% (with 85.7% accordance and 67.5% concordance) for chicken rinse, and 91.7% (with 100% accordance and 83.3% concordance) for pig swab. Thus, the interlaboratory variation due to personnel, reagents, thermal cyclers, etc., did not affect the performance of the method, which will be proposed as part of a developing international PCR standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号