首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report enhanced sample confinement on microfluidic devices using a combination of electrokinetic flow from adjacent control channels and electric field shaping with an array of channels perpendicular to the sample stream. The basic device design consisted of a single first dimension (1D) channel, intersecting an array of 32 or 96 parallel second dimension (2D) channels. To minimize sample dispersion and leakage into the parallel channels as the sample traversed the sample transfer region, control channels were placed to the left and right of the 1D and waste channels. The electrokinetic flow from the control channels confined the sample stream and acted as a buffer between the sample stream and the 2D channels. To further enhance sample confinement, the electric field was shaped parallel to the sample stream by placing the channel array in close proximity to the sample transfer region. Using COMSOL Multiphysics, initial work focused on simulating the electric fields and fluid flows in various device geometries, and the results guided device design. Following the design phase, we fabricated devices with 40, 80, and 120 microm wide control channels and evaluated the sample stream width as a function of the electric field strength ratio in the control and 1D channels (E(C)/E(1D)). For the 32 channel design, the 40 and 80 microm wide control channels produced the most effective sample confinement with stream widths as narrow as 75 microm, and for the 96 channel design, all three control channel widths generated comparable sample stream widths. Comparison of the 32 and 96 channel designs showed sample confinement scaled easily with the length of the sample transfer region.  相似文献   

2.
We study the elastic deformation of poly(dimethylsiloxane) (PDMS) microchannels under imposed flow rates and the effect of this deformation on the laminar flow profile and pressure distribution within the channels. Deformation is demonstrated to be an important consideration in low aspect ratio (height to width) channels and the effect becomes increasingly pronounced for very shallow channels. Bulging channels are imaged under varying flow conditions by confocal microscopy. The deformation is related to the pressure and is thus non-uniform throughout the channel, with tapering occurring along the stream-wise axis. The measured pressure drop is monitored as a function of the imposed flow rate. For a given pressure drop, the corresponding flow rate in a deforming channel is found to be several times higher than expected in a non-deforming channel. The experimental results are supported by scaling analysis and computational fluid dynamics simulations coupled to materials deformation models.  相似文献   

3.
The effects of flow rate, flow direction, flow ratio, pressure, membrane area, channel depth and channel shape on the optimization of gas-diffusion flow-injection systems are described in detail. A nonreacting chemical system, chlorine dioxide, was used to study the physical dispersion of the gas-diffusion systems. It was found that slow flow rates and shallow channels are optimal. Stopped-flow conditions in a nonreacting chemical system may not be worth the cost in time. For chemical systems in which the analyte is consumed, the optimized parameters included stopped flow.  相似文献   

4.
Hydrodynamic dispersion in shallow microchannels with almost parabolic cross-sectional shapes and with heights much less than their widths is studied experimentally. Both long serpentine channels and rotary mixers are used. The experimental results demonstrate that the dispersion depends on the width rather than the height of the channel. The results are in quantitative agreement with a recently proposed theory of dispersion in shallow channels.  相似文献   

5.
A one-step immunomagnetic separation technique was performed on a microfluidic platform for the isolation of specific cells from blood samples. The cell isolation and purification studies targeted T cells, as a model for low abundance cells (about 1:10,000 cells), with more dilute cells as the ultimate goal. T cells were successfully separated on-chip from human blood and from reconstituted blood samples. Quantitative polymerase chain reaction analysis of the captured cells was used to characterize the efficiency of T cell capture in a variety of flow path designs. Employing many (4-8), 50 microm deep narrow channels, with the same overall cross section as a single, 3 mm wide channel, was much more effective in structuring dense enough magnetic bead beds to trap cells in a flowing stream. The use of 8-multiple bifurcated flow paths increased capture efficiencies from approximately 20 up to 37%, when compared to a straight 8-way split design, indicating the value of ensuring uniform flow distribution into each channel in a flow manifold for effective cell capture. Sample flow rates of up to 3 microL min(-1) were evaluated in these capture beds.  相似文献   

6.
Electrophoretic exclusion (EE) is a counterflow gradient technique that exploits hydrodynamic flow and electrophoretic forces to exclude, enrich, and separate analytes. Resolution for this technique has been theoretically examined and the smallest difference in electrophoretic mobilities that can be completely separated is estimated to be 10?13 cm2/Vs. Traditional and mesoscale systems have been used, whereas microfluidics offers a greater range of geometries and configurations towards approaching this theoretical limit. To begin to understand the impact of seemingly subtle changes to the entrance flow and the electric field configurations, three closely related microfluidic interfaces were modeled, fabricated, and tested. These interfaces consisted of systematically varying placement of an asymmetric electrode relative to a channel entrance: leading electrode placed outside the channel entrance, leading electrode aligned with the channel, and leading electrode placed within the channel. A charged fluorescent dye is used as a sensitive and accurate probe for the model and to test the concentration variation at these interfaces. Models and experiments focused on visualizing the concentration profile in areas of high temporal dynamics, thus providing a severe test of the models. Experimental data and simulation results showed strong qualitative agreement. The complexity of the electric and flow fields about this interface and the agreement between models and testing suggests the theoretical assessment capabilities can be used to faithfully design novel and more efficient interfaces.  相似文献   

7.
Ross D  Ivory CF  Locascio LE  Van Cott KE 《Electrophoresis》2004,25(21-22):3694-3704
We report the results of experiments and simulations on electrokinetic flow in diverging microchannels (with cross-sectional area that increases with distance along the channel). Because of conservation of mass and charge, the velocity of an analyte in the channel decreases as the channel cross-section increases. Consequently, the leading edge of a band of sample moves more slowly than the trailing edge and the sample band is compressed. Sample peak widths, rather than increasing diffusively with time, can then be controlled by the geometry of the channel and can even be made to decrease with time. We consider the possibility of using this peak compression effect to improve the resolution of electrophoretic separations. Our results indicate that for typical separations that are dispersion limited, this peak compression effect is more than offset by the decreased distance between peaks, and the separation resolution in diverging channels is worse than that found for straight channels at the same applied voltage. For separations in very short channels or at very high field strengths, however, when the separation efficiency is injection limited, the peak compression effect is dominant and diverging channels can then be used to achieve improved separation resolution.  相似文献   

8.
We propose a strategy for optimizing distribution of flow in a microfluidic chamber for microreactor, lateral flow assay and immunocapture applications. It is aimed at maximizing flow throughput, while keeping footprint, cell thickness, and shear stress in the distribution channels at a minimum, and offering a uniform flow field along the whole analysis chamber. In order to minimize footprint, the traditional tree-like or "rhombus" design, in which distribution microchannels undergo a series of splittings into two subchannels with equal lengths and widths, was replaced by a design in which subchannel lengths are unequal, and widths are analytically adapted within the Hele-Shaw approximation, in order to keep the flow resistance uniform along all flow paths. The design was validated by hydrodynamic flow simulation using COMSOL finite element software. Simulations show that, if the channel is too narrow, the Hele-Shaw approximation loses accuracy, and the flow velocity in the chamber can fluctuate by up to 20%. We thus used COMSOL simulation to fine-tune the channel parameters, and obtained a fluctuation of flow velocity across the whole chamber below 10%. The design was then implemented into a PDMS device, and flow profiles were measured experimentally using particle tracking. Finally, we show that this system can be applied to cell sorting in self-assembling magnetic arrays, increasing flow throughput by a factor 100 as compared to earlier reported designs.  相似文献   

9.
We investigate the flux of particles in a smooth single-file channel where particles cannot cross each other as well as in wider channels of varying cross section where particles execute normal diffusion. All the channels are connected to an infinite reservoir at one end and the flux of particles is measured at the other open end. We perform random walk Monte Carlo simulation using lattice model. The flux decreases monotonically as the channel cross section is increased from single-file channel to wider channel and finally reaches a constant value for a sufficiently wide channel. The observation of enhanced flux in single-file channel as compared to a wider channel can be tested for efficient separation of particles through smooth nanochannels.  相似文献   

10.
Wang Y  Lin Q  Mukherjee T 《Lab on a chip》2004,4(5):453-463
This paper presents a system-oriented model for analyzing the dispersion of electrophoretic transport of charged analyte molecules in a general-shaped microchannel, which is represented as a system of serially connected elemental channels of simple geometry. Parameterized analytical models that hold for analyte bands of virtually arbitrary initial shape are derived to describe analyte dispersion, including both the skew and broadening of the band, in elemental channels. These models are then integrated to describe dispersion in the general-shaped channel using appropriate parameters to represent interfaces of adjacent elements. This lumped-parameter system model offers orders-of-magnitude improvement in computational efficiency over full numerical simulations, and is verified by results from experiments and numerical simulations. The model is used to perform a systematic parametric study of serpentine channels consisting of a pair of complementary turn microchannels, and the results indicate that dispersion in a particular turn can contribute to either an increase or decrease of the overall band broadening. The efficiency and accuracy of the system model is further demonstrated by its application to general-shaped channels that occur in practice, including a serpentine channel with multiple complementary turns and a multi-turn spiral-shaped channel. The results indicate that our model is an accurate and efficient simulation tool useful for designing optimal electrophoretic separation microchips.  相似文献   

11.
In eccentric septate channels the pores connecting adjacent compartments are shifted off-axis, either periodically or randomly, so that straight trajectories parallel to the axis are not allowed. Driven transport of a Brownian particle in such a channel is characterized by a strong suppression of the current and its dispersion. For large driving forces, both quantities approach an asymptotic value, which can be analytically approximated in terms of the stationary distribution of the particle exit times out of a single channel compartment.  相似文献   

12.
Generating stable microscale concentration gradients is key to numerous biological and chemical analyses. Microfluidic systems offer the ability to maintain laminar fluid diffusion interfaces ideal for the production of temporally stable concentration gradients. Previous efforts have focused on pressure driven flows and have relied on networks of branching channels to create streams of varying concentrations which can subsequently be combined to form the desired gradients. In this study, we numerically and experimentally demonstrate a novel electrokinetic technique which utilizes applied voltages and surface charge heterogeneity in simpler channel geometries to control and manipulate microscale concentration gradients without the need for parallel lamination. Flow rates ranged from 30 to 460 nl min(-1) for Peclet numbers between 70 and 1100. Spatial stability of 0.6 mm or greater was obtained for a wide range of gradient shapes and magnitudes over lateral dimensions of 400-450 microm. Sensitivity analysis determined that this technique is largely independent of channel depth and species electrophoretic mobility, however channel width and the diffusion coefficient of the analyte are critical. It was concluded that by adjusting applied voltages and/or channel width, this approach to concentration gradient generation can be adapted to a wide range of applications.  相似文献   

13.
采用Langevin动力学方法模拟研究了弱电场驱动下高分子链在无限长周期管道中的输运过程. 管道由长度相等的αβ两部分周期排列而成, 其中高分子链与α管道间存在相互吸引作用, 而与β管道间存在纯排斥作用. 模拟结果表明, 高分子链在输运过程中存在明显的受限阶段, 其逃离受限的方式与管道宽度有关且满足不同的规律. 对于窄管道, 高分子链在输运过程中呈直线伸展构型且运动具有“蛇爬行”特征. 高分子链逃离受限过程伴随着整条链的运动, 从而导致迁移率随高分子链长呈周期变化, 而且在迁移率极值位置, 高分子链投影长度与管道半周期之间存在简单的整数倍关系. 对于宽管道, 高分子链在输运过程中出现弯折构型且运动具有“蠕虫运动”特征. 当链长比较长时, 高分子链可通过链前端部分的伸长逃离受限, 从而导致迁移率与高分子链长度无关. 模拟结果可能有助于利用周期管道对不同长度的高分子链进行分离及可控输运.  相似文献   

14.
Guo L  Huang Y  Kikutani Y  Tanaka Y  Kitamori T  Kim DH 《Lab on a chip》2011,11(19):3299-3304
Herein, a simple and effective approach is reported for the in situ generation and regeneration of a Au nanorod (AuNR) monolayer inside a glass/silica-based, closed-surface flow channel. The density of the AuNR monolayer in the flow channel can be easily modified by varying the concentration of the AuNR and the cetyltrimethylammonium bromide as well as the incubation time. The fabricated AuNR monolayer in the flow channels was stable under harsh conditions, such as in extreme pH, organic solvents and at a fast flow rate. In addition, the flow channel could be reused by removing the immobilized AuNRs via the injection of diluted aqua regia or potassium iodide; the AuNR monolayer can subsequently be regenerated. The AuNRs in the closed flow channel were further exploited as a label-free detection method for a clinical biomarker, neutrophil gelatinase-associated lipocalin (NGAL), based on single-nanoparticle plasmonic assay. The corresponding limit of detection for NGAL was measured to be 8.5 ng mL(-1) (~340 pM) based on a signal-to-noise ratio of 3. The estimated recovery of NGAL in human serum and urine was higher than 80%, which indicates that this technique could potentially be used for the diagnosis of acute kidney injury.  相似文献   

15.
Polyimide-based microfluidic devices   总被引:1,自引:0,他引:1  
This paper describes the development of polyimide-based microfluidic devices. A layer transfer and lamination technique is used to fabricate flexible microfluidic channels in various shapes and with a wide range of dimensions. High bond strengths can be achieved by cure cycle adaptation and surface treatment of the polyimide layers prior to bonding. The polyimide microchannels can be combined with metallization layers to fabricate electrodes inside and outside channels. The resulting devices can be used for flexible fluidic and electrical connectors, implantable fluid delivery devices, microelectrodes with embedded fluidic channels, chip-based flow cytometry and for a great variety of other applications in medical, chemical or biological research.  相似文献   

16.
This Article describes the use of capillary pressure to initiate and control the rate of spontaneous liquid-liquid flow through microfluidic channels. In contrast to flow driven by external pressure, flow driven by capillary pressure is dominated by interfacial phenomena and is exquisitely sensitive to the chemical composition and geometry of the fluids and channels. A stepwise change in capillary force was initiated on a hydrophobic SlipChip by slipping a shallow channel containing an aqueous droplet into contact with a slightly deeper channel filled with immiscible oil. This action induced spontaneous flow of the droplet into the deeper channel. A model predicting the rate of spontaneous flow was developed on the basis of the balance of net capillary force with viscous flow resistance, using as inputs the liquid-liquid surface tension, the advancing and receding contact angles at the three-phase aqueous-oil-surface contact line, and the geometry of the devices. The impact of contact angle hysteresis, the presence or absence of a lubricating oil layer, and adsorption of surface-active compounds at liquid-liquid or liquid-solid interfaces were quantified. Two regimes of flow spanning a 10(4)-fold range of flow rates were obtained and modeled quantitatively, with faster (mm/s) flow obtained when oil could escape through connected channels as it was displaced by flowing aqueous solution, and slower (micrometer/s) flow obtained when oil escape was mostly restricted to a micrometer-scale gap between the plates of the SlipChip ("dead-end flow"). Rupture of the lubricating oil layer (reminiscent of a Cassie-Wenzel transition) was proposed as a cause of discrepancy between the model and the experiment. Both dilute salt solutions and complex biological solutions such as human blood plasma could be flowed using this approach. We anticipate that flow driven by capillary pressure will be useful for the design and operation of flow in microfluidic applications that do not require external power, valves, or pumps, including on SlipChip and other droplet- or plug-based microfluidic devices. In addition, this approach may be used as a sensitive method of evaluating interfacial tension, contact angles, and wetting phenomena on chip.  相似文献   

17.
A method to separate suspended particles from their medium in a continuous mode at microchip level is described. The method combines an ultrasonic standing wave field with the extreme laminar flow properties obtained in a silicon micro channel. The channel was 750 microm wide and 250 microm deep with vertical side walls defined by anisotropic wet etching. The suspension comprised "Orgasol 5 microm" polyamide spheres and distilled water. The channel was perfused by applying an under pressure (suction) to the outlets. The channel was ultrasonically actuated from the back side of the chip by a piezoceramic plate. When operating the acoustic separator at the fundamental resonance frequency the acoustic forces were not strong enough to focus the particles into a well defined single band in the centre of the channel. The frequency was therefore changed to about 2 MHz, the first harmonic with two pressure nodes in the standing wave, and consequently two lines of particles were formed which were collected via the side outlets. Two different microchip separator designs were investigated with exit channels branching off from the separation channel at angles of 90 degrees and 45 degrees respectively. The 45 degrees separator displayed the most optimal fluid dynamic properties and 90% of the particles were gathered in 2/3 of the original fluid volume.  相似文献   

18.
J B Edel  E K Hill  A J de Mello 《The Analyst》2001,126(11):1953-1957
This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (0.93 microm diameter) passing through a focused laser beam at a variety of flow rates (50 nL min(-1)-8 microL min(-1)). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate velocity data for the flowing particles. Fluid manipulation is achieved by hydrodynamically pumping fluid through microchannels (150 microm wide and 50 microm deep) structured in a polydimethylsiloxane (PDMS) substrate. The mean fluorescence burst frequency is shown to be directly proportional to flow speed. Furthermore, the Poisson recurrence time and width of recovered autocorrelation curves is demonstrated to be inversely proportional to flow speed. The component-based confocal fluorescence detection system is simple and can be applied to a diversity of planar chip systems. In addition, velocity measurement only involves interrogation of the fluidic system at a single point along the flow stream, as opposed to more normal multiple-point measurements.  相似文献   

19.
Mao P  Han J 《Lab on a chip》2005,5(8):837-844
We have characterized glass-glass and glass-Si bonding processes for the fabrication of wide, shallow nanofluidic channels with depths down to the nanometer scale. Nanochannels on glass or Si substrate are formed by reactive ion etching or a wet etching process, and are sealed with another flat substrate either by glass-glass fusion bonding (550 degrees C) or an anodic bonding process. We demonstrate that glass-glass nanofluidic channels as shallow as 25 nm with low aspect ratio of 0.0005 (depth to width) can be achieved with the developed glass-glass bonding technique. We also find that silicon-glass nanofluidic channels, as shallow as 20 nm with aspect ratio of 0.004, can be reliably obtained with the anodic bonding technique. The thickness uniformity of sealed nanofluidic channels is confirmed by cross-sectional SEM analysis after bonding. It is shown that there is no significant change in the depth of the nanofluidic channels due to anodic bonding and glass-glass fusion bonding processes.  相似文献   

20.
Wang L  Flanagan LA  Monuki E  Jeon NL  Lee AP 《Lab on a chip》2007,7(9):1114-1120
A novel dielectrophoresis switching with vertical electrodes in the sidewall of microchannels for multiplexed switching of objects has been designed, fabricated and tested. With appropriate electrode design, lateral DEP force can be generated so that one can dynamically position particulates along the width of the channel. A set of interdigitated electrodes in the sidewall of the microchannels is used for the generation of non-uniform electrical fields to generate negative DEP forces that repel beads/cells from the sidewalls. A countering DEP force is generated from another set of electrodes patterned on the opposing sidewall. These lateral negative DEP forces can be adjusted by the voltage and frequency applied. By manipulating the coupled DEP forces, the particles flowing through the microchannel can be positioned at different equilibrium points along the width direction and continue to flow into different outlet channels. Experimental results for switching biological cells and polystyrene microbeads to multiple outlets (up to 5) have been achieved. This novel particle switching technique can be integrated with other particle detection components to enable microfluidic flow cytometry systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号