首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
A highly reproducible, specific and cost-effective LC-MS/MS method was developed for simultaneous estimation of eszopiclone (ESZ) with 50 μL of human plasma using paroxetine as an internal standard (IS). The API-4000 LC-MS/MS was operated under the multiple reaction-monitoring mode using the electrospray ionization technique. A simple liquid-liquid extraction process was used to extract ESZ and IS from human plasma. The total run time was 1.5 min and the elution of ESZ and IS occurred at 0.90 min; this was achieved with a mobile phase consisting of 0.1% formic acid-methanol (15:85, v/v) at a flow rate of 0.50 mL/min on a Discover C(18) (50 × 4.6 mm, 5 μm) column. The developed method was validated in human plasma with a lower limit of quantitation of 0.1 ng/mL for ESZ. A linear response function was established for the range of concentrations 0.10-120 ng/mL (r > 0.998) for ESZ. The intra- and inter-day precision values for ESZ were acceptable as per FDA guidelines. Eszopiclone was stable in the battery of stability studies, viz. bench-top, autosampler and freeze-thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans.  相似文献   

4.
A rapid and sensitive method for the quantitation of buspirone in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed. Plasma samples were treated by liquid-liquid extraction with methyl tert-butyl ether (MTBE). The chromatographic separation was performed isocratically on a reversed-phase Shiseido C18 column (50 mm x 2.0 mm, 3 microm) with a mobile phase of acetonitrile/0.1% acetic acid (1:1, v/v). The acquisition was performed in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 386 --> 122 for buspirone and m/z 409 --> 238 for amlodipine (the internal standard). The method was validated to determine its specificity, recovery, limit of quantitation, accuracy and precision. The lower limit of quantitation was 0.02 ng/mL with a relative standard deviation of less than 10%. The present method provides an accurate, precise and sensitive tool for buspirone and was successfully applied to a pharmacokinetic study in eight subjects.  相似文献   

5.
6.
A highly sensitive, specific and simple LC-MS/MS method was developed for the simultaneous estimation of dexlansoprazole (DEX) with 50 μL of human plasma using omeprazole as an internal standard (IS). The API-4000 LC-MS/MS was operated under multiple reaction-monitoring mode using electrospray ionization. A simple liquid-liquid extraction process was used to extract DEX and IS from human plasma. The total run time was 2.00 min and the elution of DEX and IS occurred at 1.20 min. This was achieved with a mobile phase consisting of 0.2% ammonia-acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on an X-terra RP 18 (50 × 4.6 mm, 5 μm) column. The developed method was validated in human plasma with a lower limit of quantitation of 2 ng/mL for DEX. A linear response function was established for the range of concentrations 2.00-2500.0 ng/mL (r > 0.998) for DEX. The intra- and inter-day precision values for DEX met the acceptance criteria as per FDA guidelines. DEX was stable in the battery of stability studies, viz. bench-top, auto-sampler and freeze-thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans.  相似文献   

7.
A highly sensitive, specific and fully validated LC‐MS/MS method as per general practices of industry has been developed for estimation of lamotrigine (LAM) with 100 μL of human plasma using flucanozole as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using electrospray ionization. A simple liquid–liquid extraction process was used to extract LAM and IS from human plasma. The total run time was 2.0 min and the elution of LAM and IS occurred at 1.25 and 1.45 min; this was achieved with a mobile phase consisting of 0.1% formic acid–methanol (20:40:40, v/v) at a flow rate of 0.50 mL/min on a Discovery CN (50 × 4.6 mm, 5 µm) column. The developed method was validated in human plasma with a lower limit of quantitation of 0.1 ng/mL for LAM. A linear response function was established for the range of concentrations 0.1–1500 ng/mL (r > 0.998) for LAM. The intra‐ and inter‐day precision values for LAM met the acceptance as per Food and Drug Administration guidelines. LAM was stable in the set of stability studies, viz. bench‐top, autosampler and freeze–thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
9.
10.
11.
A sensitive, specific and simple LC‐MS/MS method was developed for the identification and quantification of bivalirudin in human plasma using diazepam as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under multiple‐reaction monitoring mode using electrospray ionization. The sample preparation consisted of an easy protein precipitation sample pretreatment with methanol. Chromatographic separation was achieved on a Zorbax Eclipse plus C18 100 × 2.1 mm column with a mobile phase of water–methanol–0.1% formic acid. The analytes were detected with a triple quadrupole Quantum Access with positive ionization. Ions monitored in the multiple‐reaction monitoring mode were m/z 1091 → 650 for bivalirudin (at 2.70 min) and m/z 285 → 193 for diazepam (at 3.85 min). The developed method was validated in human plasma with a lower limit of quantitation of 20 µg/L for bivalirudin. A linear response function was established for the range of concentrations 20–10,000 µg/L (r > 0.998) for bivalirudin. The intra‐ and inter‐day precision values for bivalirudin met the acceptance criteria as per US Food and Drug Administration guidelines. Bivalirudin was stable in the battery of stability studies, viz. bench‐top, freeze–thaw cycles and long‐term stability. The developed assay method was applied to an intravenous administration study in humans. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A rapid and easy procedure to screen for trichothecenes in plasma and urine is presented. The toxins are extracted using a Clin-Elut column, hydrolyzed to their corresponding parent alcohols and cleaned up with a silica cartridge followed by derivatization for gas chromatographic analysis. The detection of any of the parent alcohols in plasma or urine would indicate an exposure to trichothecenes. Recoveries in urine are between 78 and 119% at levels of 50-1000 ng/ml and recoveries in plasma are between 80 and 116% at levels of 50-500 ng/ml. The limit of detection is better than 25 ppb.  相似文献   

13.
A highly sensitive and specific LC‐MS/MS method has been developed for simultaneous quantification of ethionamide and ethionamide sulfoxide in human plasma (300 µL) using prothionamide as an internal standard (IS). Solid‐phase extraction was used to extract ethionamide, ethionamide sulfoxide and IS from human plasma. The chromatographic separation of ethionamide, ethionamide sulfoxide and IS was achieved with a mobile phase consisting of 0.1% acetic acid : acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Peerless Basic C18 column. The total run time was 3.5 min and the elution of ethionamide, ethionamide sulfoxide and IS occurred at 2.50, 2.18 and 2.68 min, respectively. A linear response function was established for the range of concentrations 25.7–6120 ng/mL (r > 0.998) for ethionamide and 50.5–3030 ng/mL (r > 0.998) for ethionamide sulfoxide. The intra‐ and inter‐day precision values for ethionamide and ethionamide sulfoxide met the acceptance as per FDA guidelines. Ethionamide and ethionamide sulfoxide were stable in battery of stability studies, viz. bench‐top, autosampler and freeze–thaw cycles. The developed assay was applied to a pharmacokinetic study in humans. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of rhein with 100 microL human plasma using celecoxib as an internal standard (IS). The API-4,000 Q-Trap LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of rhein and IS from human plasma with acetonitrile, which yielded consistent recoveries of 36.01 and 65.85% for rhein and IS, respectively. The total chromatographic run time was 5.0 min and the elution of rhein and IS occurred at approximately 1.60 and 3.96 min, respectively. The resolution of peaks was achieved with 0.01 m ammonium acetate (pH 6.0):acetonitrile:methanol (30:58:12, v/v) on an Inertsil ODS-3 column. The method was proved to be accurate and precise at a linearity range of 0.005-5.00 microg/mL with a correlation coefficient (r) of >or=0.995. The lower limit of quantitation was 0.005 microg/mL. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. Rhein was found to be stable in the battery of stability studies. The application of the assay to pre-clinical pharmacokinetic studies confirmed the utility of the assay to derive pharmacokinetic parameters.  相似文献   

15.
16.

A simple method for the simultaneous quantification of meropenem and the recently approved β-lactamase inhibitor, vaborbactam, in human plasma and renal replacement therapy effluent (RRTE) was developed and validated. This antibiotic combination protects a primary β-lactam, meropenem, with a new β-lactamase inhibitor, and expands the limited options for treatment of multidrug-resistant Gram-negative infections. Meropenem, vaborbactam, and the internal standards [2H6]-meropenem and sulbactam in plasma and RRTE were processed using acetonitrile followed by a chromatographic separation on a Poroshell HPH-C18 column with a gradient elution of the mobile phases and monitored using mass spectrometry detection. The calibration range was 0.05 to 100 μg mL−1 for both meropenem and vaborbactam. The intra-day and inter-day precision and accuracy were less than 15% for both meropenem and vaborbactam and the recovery from plasma was 96% for both meropenem and vaborbactam and the recovery from RRTE was 93% and 103% for meropenem and vaborbactam, respectively. This methodology was successfully applied to an ex vivo characterisation study of the effects of renal replacement therapy modalities on the pharmacokinetics of meropenem and vaborbactam (Antimicrob Agents Chemother 62(10), 2018).

Graphical abstract

  相似文献   

17.
A simple, sensitive and specific high-performance liquid chromatography method is described for simultaneous determination of rosuvastatin (RST) and gemfibrozil (GFZ) in human plasma using celecoxib as an internal standard (IS). The assay procedure involved extraction of RST, GFZ and IS from plasma into acetonitrile. Following separation and evaporation of the organic layer the residue was reconstituted in the mobile phase and injected onto an X-Terra C(18) column (4.6 x 150 mm, 5.0 microm). The chromatographic run time was less than 20 min using flow gradient (0.0-1.60 mL/min) with a mobile phase consisting of 0.01 M ammonium acetate:acetonitrile:methanol (50:40:10, v/v/v) and UV detection at 275 nm. Nominal retention times of RST, GFZ and IS were 6.7, 13.9 and 16.4 min, respectively. Absolute recovery of both analytes and IS was greater than 90%. The lower limit of quantification (LLOQ) of RST and GFZ was 0.03 and 0.30 microg/mL, respectively. Linearity was excellent (r(2) = 0.999) in the 0.03-10 microg/mL and 0.3-100 microg/mL ranges for RST and GFZ, respectively. The inter- and intra-day precisions in the measurement of RST quality control (QC) samples 0.03, 0.09, 2.50 and 8.00 microg/mL were in the range 2.37-9.78% relative standard deviation (RSD) and 0.92-10.08% RSD, respectively. Similarly, the inter- and intra-day precisions in the measurement of GFZ quality control (QC) samples 0.30, 0.90, 25.0 and 80.0 microg/mL were in the ranges 2.79-6.27 and 0.96-9.69% RSD, respectively. Accuracies in the measurement of QC samples for RST and GFZ were in the range 85.43-107.23 and 84.98-102.35% respectively, of the nominal values. RST and GFZ were stable in the array of stability studies viz., bench-top, auto-sampler and freeze-thaw cycles. Stability of RST and GFZ was established for 1 month at -80C. The application of the assay in an oral pharmacokinetic study in rats co-administered with RST and GFZ is described.  相似文献   

18.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 microL human plasma using memantine as an internal standard (IS). The API-4000 was operated under multiple-reaction monitoring mode (MRM) using the electrospray ionization technique. Solid-phase extraction was used to extract PPX and IS from human plasma. The resolution of peaks was achieved with 0.01 m ammonium acetate buffer (pH 4.4):acetonitrile (30:70, v/v) on a Discovery CN column. The total chromatographic run time was 3.0 min and the elution of PPX and IS occurred at approximately 2.32 and 2.52, respectively. The MS/MS ion transitions monitored were 212.10 --> 153.10 for PPX and 180.20 --> 107.30 for IS. The method was proved to be accurate and precise at linearity range of 20-3540 pg/mL with a correlation coefficient (r) of > or =0.999. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 0.25 mg PPX tablet.  相似文献   

19.
Phenoprolamine hydrochloride is a novel compound that works against a variety of types of hypertension. The purpose of this study was to develop a simple and sensitive high-performance liquid chromatographic method for quantitation of low phenoprolamine hydrochloride concentrations in human plasma and to apply it to pharmacokinetic study. The procedure involved extraction of the drug and clonidine (internal standard) from the plasma using diethyl ether. Chromatographic separations were carried out on a 4.6 x 200 mm Hypersil silica column with UV detection at 230 nm. The isocratic mobile phase, 1% ammonium acetate (pH 5.4) and methanol (0.3:99.7, v/v), was run at 1 mL/min. Extraction recovery was 84% for phenoprolamine hydrochloride at a concentration level of 200 ng/mL, and 76% for clonidine at 200 ng/mL. The method was linear in the concentration range 5-4000 ng/mL with a lower limit of quantitation of 5 ng/mL for phenoprolamine hydrochloride. Inter- and intra-day coefficients of variation were less than 10%. The validated method was successfully applied to a pharmacokinetic study in human after an oral administration of the drug, and the pharmacokinetic parameters are presented.  相似文献   

20.
Immunoassays for the measurement of glucuronides in human urine can be a helpful tool for the assessment of human exposure to toxic chemicals. Therefore an enzyme imimunoassay (EIA) for the specific detection of phenyl-beta-D-thioglucuronide was developed. The immunoconjugate was formed by coupling p-aminophenyl-beta-D-thioglucuronide to the carrier protein thyroglobulin leaving an exposed glucuronic acid. The hapten-protein conjugate was adsorbed to gold colloids in order to enhance the immunogenic effect. Rabbits were injected with the immunogold conjugates to raise polyclonal antibodies. The resulting competitive assay showed an inhibition by phenyl-beta-D-thioglucuronide at sample concentrations of 23.0 +/- 1.3 ng/mL (50% B/B0) and a high cross-reactivity to p-aminophenyl-beta-D-thioglucuronide (120%). Little cross-reactivities (< 2%) were observed for potential urinary cross reactants. In addition human urine samples were incubated with beta-glucuronidase in order to investigate the EIA for specific matrix effects. An integration of high-performance liquid chromatography (HPLC) and EIA was developed in an attempt to decrease the matrix effects and increase the sensitivity of the overall method. The hyphenated technique HPLC-EIA may be used to monitor human exposure to toxic thiophenol which is excreted by mammals as urinary phenyl thioglucuronide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号