首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
毛细管电泳法分离联萘酚对映体   总被引:5,自引:1,他引:4  
张玉霞  叶英植 《分析化学》1998,26(10):1189-1191
利用新的手性选择剂苄基氯化辛可宁,在非水相中成功地分离了联萘酚的对映体,并对分离的机理作了初步地探讨。  相似文献   

2.
Lecnik O  Gübitz G  Schmid MG 《Electrophoresis》2003,24(17):2983-2985
This paper deals with the chiral separation of hydroxy acids using diallyl-dimethylammonium chloride as a positive charge-providing agent in the continuous bed. The chiral continuous bed was prepared by in situ copolymerization of monomers, including an L-4-hydroxyproline derivative as a chiral selector. This phase was applied to the chiral separation of hydroxy monocarboxylic acids and hydroxy dicarboxylic acids, respectively. The influence of both the selector concentration and the charge-providing agent on retention and separation was investigated.  相似文献   

3.
Capillary electrophoresis methods were developed for the enantiomeric separation of 27 citalopram analogues. Sulfated β‐cyclodextrin was the most broadly selective and useful chiral selector. The separations of most of the citalopram analogue compounds reported in this work have not been reported previously. Excellent enantiomeric separations were obtained for 26 out of 27 compounds, and most of the separations were achieved within 10 min. The effects of chemical parameters such as chiral selector types, buffer types, chiral selector and buffer concentrations, buffer pH and organic modifiers on the separation were investigated. The influence of analyte structure on separation also was examined and discussed.  相似文献   

4.
卡那霉素作为手性选择剂的毛细管电泳手性药物分离研究   总被引:3,自引:0,他引:3  
建立了一种以天然易得的卡那霉素为手性添加剂,用毛细管区带电泳法快速分离市售对乙肝有良好治疗效果的药物联苯双脂衍生物的方法,拓宽了毛细管电泳中手性选择剂的范围,通过实验研究了卡那霉素、甲醇 含量PH值,磷酸盐缓冲体系和硼硝缓冲体系对手性分离的影响,以及三种有机溶剂(甲醇、乙晴、异丙醇)添加剂对手性分离的影响,结果表明,在含有3%卡那霉素,30mol/L,硼砂缓冲体系(PH=8.0)添加30%异丙醇是最佳的分离条件。  相似文献   

5.
Dai R  Nie X  Li H  Saeed MK  Deng Y  Yao G 《Electrophoresis》2007,28(15):2566-2572
A novel water-soluble beta-CD-derivatized erythromycin (EM) was synthesized and used as an effective chiral selector for the resolution of chiral compounds in CZE. The purpose of substitution at the primary hydroxyl site of beta-CD with 1-oxygen-2,3-epoxypropane is to produce a compound having functions of both beta-CD and EM. beta-CD-derivatized EM exhibited excellent enantioselectivities compared with single beta-CD and EM for chiral separation in CE. We also investigated the influence of pH and concentration of BGE, concentration of chiral selector, applied potential, and organic modifier on chiral compounds' separation.  相似文献   

6.
In capillary electrophoresis (CE), separation of enantiomers of a chiral compound can be achieved through the chiral interactions and/or complex formation between the chiral selector and the enantiomeric analytes on leaving their diastereomeric forms with different stability constants and hence different mobilities. A great number of chiral selectors have been employed in CE and among them macrocyclic antibiotics exhibited excellent enantioselective properties towards a wide number of racemic compounds. The use of azithromycin (AZM) as a chiral selector has not been reported previously. This work reports the use of AZM as a chiral selector for the enantiomeric separations of five chiral drugs and one amino acid (tryptophan) in CE. The enantioseparation is carried out using polar organic mixtures of acetonitrile (ACN), methanol (MeOH), acetic acid and triethylamine as run buffer. The influences of the chiral selector concentration, ACN/MeOH ratio, applied voltage and capillary temperature on enantioseparation are investigated. The results show that AZM is a viable chiral selector in CE for the enantioseparation of the type of chiral drugs investigated.  相似文献   

7.
Enantioseparations of fourteen dansyl amino acids were achieved by using a positively-charged single-isomer beta-cyclodextrin, mono-(3-methyl-imidazolium)-beta-cyclodextrin chloride, as a chiral selector. Separation parameters such as buffer pH, selector concentration, separation temperature, and organic modifier were investigated for the enantioseparation in order to achieve the maximum possible resolution. Chiral separation of dansyl amino acids was found to be highly dependent on pH since the degree of protonation of these amino acids can alter the strength of electrostatic interaction and/or inclusion complexation between each enantiomer and chiral selector. In general, the chiral resolution of dansyl amino acids was enhanced at higher pH, which indicates that the carboxylate group on the analytes may interact with the imidazolium group of cationic cyclodextrin. For most analytes, a distinct maximum in enantioresolution was obtained at pH 8.0. Moreover, the chiral separation can be further improved by careful tuning of the separation parameters such as higher selector concentration (e.g. 10 mM), lower temperature, and addition of methanol. Enantioseparation of a standard mixture of these dansyl amino acids was further achieved in a single run within 30 min.  相似文献   

8.
Na N  Hu Y  Ouyang J  Baeyens WR  Delanghe JR  Taes YE  Xie M  Chen H  Yang Y 《Talanta》2006,69(4):866-872
A new strategy for chiral separation by capillary electrophoresis employing modified-nanoparticles as chiral selector is described for clenbuterol analysis. Nanoparticles modified with β-cyclodextrin (β-CD) form a large surface area platform to serve as a pseudostationary chiral phase, which can be applied for the enhancement of the enantioseparation. The application of four kinds of nanoparticles was investigated (multi-walled nanotubes (MWNTs), polystyrene (PS), TiO2 and Al2O3) modified with single layer β-CD as chiral selector in the enantioseparation of clenbuterol by capillary electrophoresis (CE). Successful clenbuterol enantioseparation could be achieved with the β-CD-modified MWNTs as chiral selector. X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) confirmed the β-CD modification of the nanoparticles. The effects of nanoparticles, surfactant, chiral selector (β-CD) and run buffer were studied in relation to the enantiomeric separation of clenbuterol. This study opens attractive perspectives for the use of modified nanoparticles for chiral separational purposes in CE.  相似文献   

9.
Micellar electrokinetic chromatography (MEKC) was successfully and conveniently applied to the chiral separation with the addition of cyclodextrins (CDs) as chiral selector to the running buffer. Chiral separation depended on the type of CD; in particular, beta-CD was effective for the chiral separation of racemorphan. We investigated the optimal conditions of type and concentration of CD as chiral selector for the routine enantiomeric separation of racemorphan with good reproducibility. The effects of other parameters such as buffer pH and detection wavelength were also investigated to obtain the optimum conditions for the enantiomeric separation of racemorphan. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used for confirmation of racemorphan. The optimal conditions for enantiomeric separation of the racemorphan were as follows: 50 mM borate buffer at pH 9.4 with 50 mM SDS, 10 mM beta-CD and 20% 1-propanol, 57 cm x 50 microns fused-silica capillary column, and UV detection at 192 nm. Based on the developed method, racemorphan in human urine was also separated and determined using solid-phase extraction and MEKC.  相似文献   

10.
Nonlinear effects caused by molecular association of enantiomers in non-racemic mixtures can cause unexpected effects in chiroptics, NMR spectroscopy, homogeneous catalysis, and chromatography. Herein we present a theoretical model to simulate and verify unusual elution orders of enantiomers on an achiral stationary phase doped with a small amount of a chiral selector or achiral columns coupled with columns doped with a chiral selector. Scenarios with strong, medium, and weak associations of enantiomers, different separation efficiencies typical for flash chromatography and liquid chromatography, and the influence of the enantioselectivity of the chiral selector on the complex equilibria have been investigated. The findings presented here are of importance for the validation of the determination of enantiomeric ratios in not fully separated elution zones as well as for the preparative separation of non-racemic enantiomeric mixtures on chiral stationary phases bonded to achiral matrices.  相似文献   

11.
Cho SI  Lee KN  Kim YK  Jang J  Chung DS 《Electrophoresis》2002,23(6):972-977
Chiral crown ether, (+)-(18-crown-6)-tetracarboxylic acid (18C6H(4)), is an effective chiral selector for resolving enantiomeric primary amines owing to the difference in affinities between 18C6H(4) and each of the amine enantiomers. In addition to the destacking effect of sodium ion in the sample solution, the strong affinity of sodium ion to the polyether ring of crown ether is unfavorable to chiral capillary electrophoresis using 18C6H(4) as a chiral selector. In this report, the chiral separation of gemifloxacin dissolved in a saline sample matrix using 18C6H(4) was investigated. Adding a chelating agent, ethylenediaminetetraacetic acid (EDTA), to the run buffer greatly improved the separation efficiencies and peak shapes. The successful chiral separation of gemifloxacin in a urinary solution was demonstrated for both capillary and microchip electrophoresis.  相似文献   

12.
Fritless particle-loaded monoliths for chiral capillary electrochromatographic (CEC) separation were prepared. Silica particles containing a chiral selector are suspended in a monomer solution, which is drawn into the capillary followed by in situ polymerization. Thereby the silica-based particles containing the chiral selector are embedded in a nonchiral continuous bed. This kind of chiral stationary phase is inexpensive, easy, and reproducible to prepare and circumvents the preparation of frits. As a model, teicoplanin aglycone as chiral selector bonded to 3 microm silica particles was used. The applicability of this approach is demonstrated by means of the chiral separation of aliphatic and aromatic amino acids and dipeptides. As a further application, the chiral selector ristocetin A bonded to 3 microm silica particles was used for the enantiomeric separation of chiral alpha-hydroxy acids. Since alpha-hydroxy acids migrate toward the anode, a cationic charge-providing agent was copolymerized with the matrix. This served to reverse the direction of the electroosmatic flow (EOF).  相似文献   

13.
In this work a chiral stationary phase was prepared by dynamically coating a monolithic reversed-phase HPLC column with a vancomycin-derivative as chiral selector. A hydrophobic alkyl-chain was attached to the vancomycin molecule, providing the immobilization of the chiral selector on the reversed-phase material. Dansyl amino acids were chosen as model analytes for testing the separation power of the dynamically coated phase. All investigated compounds were separated into their enantiomers. Compared with a conventionally packed vancomycin-CSP, a reversal of the enantiomer elution order was obtained.  相似文献   

14.
采用手性多羟基化合物—硼酸络合酸为手性选择剂,建立了分离盐酸莱克多巴胺4个立体异构体的手性毛细管电泳(NACE)方法.实验考察了手性选择剂的种类、浓度和三乙胺浓度对手性分离效果的影响.结果表明,双丙酮-D-甘露糖醇—硼酸络合酸手性选择剂的分离效果最好,优化的缓冲溶液组成为含100 mmol/L双丙酮-D-甘露糖醇、10...  相似文献   

15.
The enantiomeric separation of gemfibrozil chiral analogues was performed by capillary zone electrophoresis (CZE). Resolution of the enantiomers was achieved using heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin (TM-beta-CD) as chiral selector dissolved into a buffer solution. In order to optimize the separation conditions, type, pH and concentration of running buffer and chiral selector concentration were varied. For each pH value, the optimum chiral selector concentration that produced the resolution of the isomers was found. The migration order of labile diastereoisomers formed was valued at the optimum experimental conditions by adding a pure optical isomer to the racemic mixture. Data from 1H NMR studies confirmed host-guest interaction between TM-beta-CD and 5-(2,5-dimethylphenoxy)-2-ethylpentanoic acid sodium salt. The hypothesized stoichiometry host:guest was 1:1. An apparent equilibrium constant (Ka) was estimated monitoring the chemical shift variation as a function of TM-beta-CD concentration. Salt effect on complexation equilibrium constant was also investigated.  相似文献   

16.
Jing  Guo  HOU  Tian  Xi  HE 《中国化学快报》2003,14(3):280-282
Erythromycin as a new chiral selector was first used for chrial separation of four derivatives of biphenyldimethylester enantiomers on CE.The influence of pH,the chiral selector concentration and organic modifiers were preliminarily studied.Experiments show that the erythromycin as chiral selector is useful to CE.  相似文献   

17.
林秀丽  李关宾  主沉浮  吴培  关亚风 《色谱》2001,19(2):109-111
 建立了一种以L 白氨酸为手性选择剂用毛细管区带电泳法快速分离 12种手性药物的方法。实验结果表明 ,手性对映体的分离度受L 白氨酸浓度和缓冲液 pH的影响。在含有 70mmol/LL 白氨酸 ,5 0mmol/L硼砂 (pH9.0 )的溶液中 ,12种手性药物在 11min之内得到了基线分离。  相似文献   

18.
Herein we focused on using a novel separation technology, solvent sublation, for the enantioseparation of α-cyclohexylmandelic acid (CHMA). The experiment was carried out in a conventional bubble column using d-iso-butyl tartrate (d-IBTA) and sodium dodecyl sulfate (SDS) as a chiral selector and surfactant, respectively (Fig. 7). Several important parameters influencing the separation performance, such as the type of organic phase, the pH in the aqueous phase, and the concentrations of CHMA, d-IBTA, and SDS were investigated. Under the optimal operating conditions, the enantiomeric excess and separation factor were 54.85% and 4.5, respectively. The yields of d-enantiomer and l-enantiomer were 82.20% and 38.94%, respectively. Finally, the thermodynamic properties of the separation were investigated, which indicated an enthalpy-controlled process. This technique is an efficient chiral separation method, with many advantages, such as low amounts of organic solvent and chiral selector required and easier realization of the multi-stage operation.  相似文献   

19.
Chiral separation of iodiconazole, a new antifungal drug, and 12 new structurally related triadimenol analogues had been developed by capillary electrophoresis (CE) using hydroxypropyl-γ-cyclodextrin (HP-γ-CD) as the chiral selector. The effect of structural features of analytes on Δt and Rs was studied under the optimum separation conditions. Using molecular docking technique and binding energy calculations, the inclusion process between HP-γ-CD and enantiomers was investigated and chiral recognition mechanisms were discussed. The results suggest that hydrogen bonding between fluorine at position 4 of the phenyl group beside the chiral carbon and the hydroxyl group on the HP-γ-CD rim and face to face π–π interactions between two phenyl rings highly contributed to the enantiorecognition process between HP-γ-CD and iodiconazole. The N-methyl group beside chiral carbon also played an important role in enantiomeric separation. Additionally, the big difference in binding energy (ΔΔE) highly contributed to good separation in the presence of HP-γ-CD chiral selector, which may be a helpful initial guide for chiral selector selection and predicting the result of enantioseparation. Furthermore, the new mathematical equation established based on the results of molecular mechanics calculations exhibited good capability in predicting chiral separation of these triadimenol analogues using HP-γ-CD mediated CE.  相似文献   

20.
The enantiomeric resolution of N-t-butyloxycarbonyl (N-t-Boc) amino acids D/L isomers by reversed-phase HPLC was investigated using cyclodextrins (CD's) as chiral selectors for the mobile phase. The use of a low pH (pH<4) for the mobile phase enabled the enantioseparation of N-t-Boc amino acids. The opposite elution order of D/L isomers was observed when hydroxypropyl-derivatized beta-CD was used instead of native beta-CD. A computer simulation of the enantioseparation showed that the ratio of the retention factors of the chiral selector and the sample determined the elution order and the resolution. When the retention factor of the chiral selector is smaller than that of the sample, an isomer having larger complex formation constant eluted faster. However, when the chiral selector had a larger retention factor than the sample, an opposite elution order of the isomers was obtained. The large difference in the retention factors between the chiral selector and the sample led to good enantiomeric separation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号