首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
This work is concerned with ion beam dynamics and compares the emittance to aberration ratios of two-and three-electrode extraction systems. The study is conducted with the aid of Version 7 of SIMION 3D ray-tracing software. The beam dependence on various parameters of the extraction systems is studied and the numerical results lead to qualitative conclusions.  相似文献   

2.
不同磁路电子回旋共振离子源引出实验   总被引:1,自引:0,他引:1       下载免费PDF全文
金逸舟  杨涓  冯冰冰  罗立涛  汤明杰 《物理学报》2016,65(4):45201-045201
空间推进所用的电子回旋共振离子源(ECRIS)应具有体积小、效率高的特点. 本文研究的ECRIS使用永磁体环产生磁场, 有效减小了体积, 该离子源利用微波在磁场中加热电子, 电子与中性气体发生电离碰撞产生等离子体. 磁场在微波加热电子的过程中起关键作用, 同时影响离子源内等离子体的约束和输运. 通过比较四种磁路结构离子源的离子电流引出特性来研究磁场对10 cm ECRIS性能的影响. 实验发现: 在使用氩气的条件下, 特定结构的离子源可引出160 mA的离子电流, 最高推进剂利用率达60%, 最小放电损耗为120 W·A-1; 所有离子源均存在多个工作状态, 工作状态在微波功率、气体流量、引出电压变化时会发生突变. 离子源发生状态突变时的微波功率、气体流量的大小与离子源内磁体的位置有关. 通过比较不同离子源的引出离子束流、放电损耗、气体利用率、工作稳定性的差异, 归纳了磁场结构对此种ECRIS引出特性的影响规律, 分析了其中的机理. 实验结果表明: 保持输入微波功率、气体流量、引出电压不变时, 增大共振区的范围、减小共振区到栅极的距离, 离子源能引出更大的离子电流; 减小共振区到微波功率入口、气体入口的距离能降低维持离子源高状态所需的最小微波功率和最小气体流量, 提高气体利用率, 但会导致放电损耗增大. 研究结果有助于深化对此类离子源工作过程的认识, 为其设计和性能优化提供参考.  相似文献   

3.
The characteristics of ion beam extraction and focused to a volume as small as possible were investigated with the aid of computer code SIMION 3D version 7.This has been used to evaluate the extraction characteristics(accel-decel system)to generate an ion beam with low beam emittance and high brightness.The simulation process can provide a good study for optimizing the extraction and focusing system of the ion beam without any losses and transported to the required target.Also,a study of a simulation model for the extraction system of the ion source was used to describe the possible plasma boundary curvatures during the ion extraction that may be affected by the change in an extraction potential with a constant plasma density meniscus.  相似文献   

4.
The characteristics of ion beam extraction and focused to a volume as small as possible were investigated with the aid of computer code SIMION 3D version 7. This has been used to evaluate the extraction characteristics (accel-decel system) to generate an ion beam with low beam emittance and high brightness. The simulation process can provide a good study for optimizing the extraction and focusing system of the ion beam without any losses and transported to the required target. Also, a study of a simulation model for the extraction system of the ion source was used to describe the possible plasma boundary curvatures during the ion extraction that may be affected by the change in an extraction potential with a constant plasma density meniscus.  相似文献   

5.
6.
张宝武  张萍萍  马艳  李同保 《物理学报》2011,60(11):113701-113701
激光汇聚铬原子沉积实验中,铬原子束准直度的好坏非常重要.利用蒙特卡罗随机思想选取原子轨迹初始条件,将52Cr原子以外的其他同位素、纵向速度分布和横向发散角等因素综合考虑,对铬原子束横向一维激光冷却进行了优化分析.经过与均匀取值法比较,这种方法能够更好地体现原子运动的不确定性,挑选出不参与冷却过程的同位素,使考察界面内原子束的横向位置分布更好的符合实验结果.结果显示,冷却过程中其他同位素的存在使原子束横向位置分布的中心最大值减小9.3%,半高宽增加11%,并且增加轮廓曲线的基底. 关键词: 激光冷却 蒙特卡罗方法 铬原子束  相似文献   

7.
Interest in preconcentration techniques for the determination of metals at ultratrace levels still continues increasingly because of some disadvantages of flameless atomic absorption spectrometry as well as the high costs of other sensitive methods in compared to flame atomic absorption spectrometry.In this study,thiol-containing sulfonamide resin was synthesized,characterized and applied as a new sorption material for solid phase extraction of nickel in drinking water samples.After preconcentration procedure,flame atomic absorption spectrometry was used for determinations.Optimum parameters were found to be pH=3.2,contact time =20 min and eluate volume=3 mL.The limit of detection was found to be 0.75 ng · mL-1.The synthesized resin exhibits the superiority in compared to the other adsorption reagents because of the fact that there is no necessity of any complexing reagent,high sorption capacity as well as the relatively fast extraction rate.The Ni concentrations in the studied 21 kind of water samples were found to be in the range of BDL-4.0 ng ·mL-1.  相似文献   

8.
A Novel exploding wire type ion source device is proposed as a metallic ion source of intense pulsed heavy ion beam (PHIB) accelerator. In the device, multiple shot operations are realized without breaking the vacuum. The basic characteristics of the device are evaluated experimentally with an aluminum wire of diameter 0.2 mm and length 25 mm. A capacitor bank of capacitance 3 μF and a charging voltage of 30 kV was used, and the wire was successfully exploded by a discharge current of 15 kA with a rise time of 5.3 μs. Plasma flux of ion current density around 70 A/cm2 was obtained at 150 mm downstream from the device. The drift velocity of ions evaluated by a time-of-flight method was 2.7×104 m/ s, which corresponds to the kinetic energy of 100 eV for aluminum ions. From the measurement of the ion current density distribution, the ion flow is found to be concentrated toward the direction where the ion acceleration gap is placed. From the experiment, the device is found to be acceptable for applying the PHIB accelerator.  相似文献   

9.
采用离子束增强沉积方法在Si和SiO2/Si衬底上制备In-N共掺杂ZnO薄膜(INZO),溅射靶是用ZnO和2 atm% In2O3粉体均匀混合并压制而成,在氩离子溅射ZnO靶的同时,氮、氩混合离子束垂直注入沉积的薄膜.实验结果显示INZO薄膜具有(002)的择优取向,并且为p型导电,电阻率最低为0.9Ωcm.薄膜在氮气、氧气气氛下退火,对薄膜的结构和电学特性与成膜和退火条件的关系进行了分析. 关键词: 氧化锌薄膜 p型掺杂 离子束增强沉积  相似文献   

10.
运用电子束、离子辅助和离子束溅射三种镀膜工艺分别制备光学薄膜,包括单层氧化物薄膜和增透膜,然后采取一系列测试手段,如Zygo轮廓仪、原子力显微镜、表面热透镜技术和X射线衍射等技术,来分析和研究不同的工艺对这些薄膜性能的不同影响,以判断合理的沉积工艺。  相似文献   

11.
蒙特卡罗模拟单阻止柱双散射体质子束流扩展方法   总被引:1,自引:0,他引:1       下载免费PDF全文
束流扩展是研究质子治疗大体积深度肿瘤的基础,利用Monte Carlo多粒子模拟软件Fluka2006.3b.10,计算质子经过单阻止柱双散射体后束流横向分布特性,与相同条件下由Highland公式经解析计算相比较.结果表明:在束流分布均匀性大于95%的范围内,Fluka计算得到的质子通量小于由Highland公式经解析计算得到的结果,膜薄的条件下二者符合好于膜厚的条件.束流扩展半径随着两个散射膜厚度的增加而增大,束流利用率先增加后减小,最大值是16.9%.  相似文献   

12.
为了对高压倍加器和静电加速器等低能加速器中一些具有特殊结构的轴对称静电元件进行模拟和设计,采用传输矩阵法编写了直流束的束流光学计算程序,并利用该程序对高频离子源预聚焦系统和移动式加速器中子源的束流光学系统进行了模拟和设计。程序将整个轴对称静电场区域看作厚透镜,并均分成若干个小区间,先利用其他电磁场软件计算区域内的轴上电势分布,然后根据该电势分布计算每个小区间内的束流传输情况得到束流的包络曲线。该程序可以用于计算非线性效应可忽略的复杂轴对称静电场中强流和弱流束的传输,且所需计算时间很短。  相似文献   

13.
14.
The bidirectional beam propagation method based on the method of lines is proposed as an innovative and efficient algorithm to investigate the optical properties of photonic band gap (PBG) structures. A few examples illustrate the application of this technique to the modeling of passive, lossy and active one-dimensional and index confined PBG structures. The algorithm results are validated by comparison with those obtained via the transfer matrix method, the mode-matching method and the finite difference time domain method. With respect to these methods, the present algorithm exhibits accurate results with reduced computer resources.  相似文献   

15.
分别在室温(25℃)和高温(300℃)下,通过X射线衍射实验对MgF2和SrF2晶体进行了晶体结构的检测.利用基于Rietveld精修方法的RIETAN-2000程序对所得实验结果进行了解析,精修了MgF2和SrF2晶体在不同温度下的各晶体结构参数,获得了原子各向同性温度因子B.通过Maximum Entropy Meth-od ( MEM)解析得到了MgF2和SrF2晶体的等高电子密度分布图谱,实现了电子密度分布的可视化.  相似文献   

16.
17.
为了研究靶前高功率束流的物理特性,欧洲散裂中子源计划研制一套靶前多丝束流剖面监测器及束晕监测器样机,样机的在线测试将在日本质子加速器研究设施的3 GeV质子束传输束线上进行。针对此束线现场安装管道狭小、监测器样机传动机构行程大的特点,提出一种适用于小通道的多点定位多丝束流剖面探头,将其与束晕探头集成在一个样机上,结构紧凑,可实现双探头的独立驱动。使用ANSYS workbench对探头及传动杆进行了变形分析,完成了样机的研制,通过丝间距光学影像测量、真空检漏、小孔通过性测试及通断检测,确保了样机的可靠性。  相似文献   

18.
 运用电子束、离子辅助和离子束溅射三种镀膜工艺分别制备光学薄膜,包括单层氧化物薄膜和增透膜,然后采取一系列测试手段,如Zygo轮廓仪、原子力显微镜、表面热透镜技术和X射线衍射等技术,来分析和研究不同的工艺对这些薄膜性能的不同影响,以判断合理的沉积工艺。  相似文献   

19.
The ^13 N+p elastic resonance scattering has been studied at the secondary radioactive beam facility of CIAE in inverse kinematics via a thick-target method. The excitation function for the ^13N(p,p) scattering was obtained in the energy interval of Ecru ≈0.5-3.2 MeV with a ^13 N secondary beam of (47.8±1.5) MeV. Careful analysis of the secondary beam components and extensive Monte-Carlo simulations enable the resolution of the experimental proton spectra. The resonance parameters for five low-lying levels in ^14 O were deduced by Rmatrix fitting calculations with MULTI7 and SAMMY-M6-BETA. The present results show general agreement with those from a recent similar work, and thus confirm the observation of a new 0^- level at 5.7 MeV in 140 with an improved width of 400(45) keV.  相似文献   

20.
石东平  李芳昱  张义 《物理学报》2006,55(10):5041-5047
高斯束谐振系统为早期宇宙遗留的随机高频引力波的探测开启了一个非常重要的窗口.计算结果表明,当入射引力波频率和高斯束不同时,高斯束谐振系统产生的一阶扰动光子流没有观测效应;当入射引力波的传播方向与高斯束对称轴的正方向不同时,高斯束谐振系统产生的一阶扰动光子流将降低几个数量级,即高斯束谐振系统只对沿某一特定方向传播的高频遗迹引力波产生有效的响应.因此,高斯束谐振系统对高频遗迹引力波的频率和传播方向具有良好的选择效应. 关键词: 高斯束谐振系统 高频遗迹引力波 一阶扰动光子流 频率选择效应 方向选择效应  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏