首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The activity of fused silica capillary tubing has been shown to vary considerably, which severely influences the reproducibility of column deactivation and inertness. Methods for producing a reproducible, high activity surface with maximum hydroxylation by various hydrothermal treatments were evaluated. Columns pretreated with 20% nitric acid at 200°C for 10 hours, deactivated with D4, coated with OV-73, and crosslinked with azo-tert-butane were found to possess excellent inertness for sensitive analytes such as alcohols, amines, and alkaloid drugs.  相似文献   

2.
In this study, application of a fused silica capillary column for analysis of toxic anthraquinones and related compounds found in plants was investigated.  相似文献   

3.
4.
Summary Flexibility, strength and adsorption inertness of fused-silica capillaries permits their extensive application for the preparation of micro-packed columns in gas chromatography. Decreasing the column diameter (from 0.5 to 0.15 mm) and the diameter of the sorbent particles (from 100 to 5 μm) results in a marked reduction of the height equivalent to a theoretical plate (HETP), as well as in diminishing the dependence of the HETP on the carrier gas flow rate. The chromatographic characteristics of fused-silica capillary micro-packed columns and open-tubular columns are compared. The fused-silica capillary micro-packed column can be used to advantage for performing rapid and trace analyses and have been shown to be adapted for application in gas-solid chromatography. Separation of organic and inorganic compounds on fused-silica capillary micro-packed columns is illustrated by practical examples. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

5.
The effect of deactivating a fused silica surface by silylation with 1,1,3,3-tetraphenyl-1,3-dimethylilazane (TPDMDS), triphenylsilylamine (TPSA), and octamethylcyclotetrasiloxane (D4) and by polydimethylsiloxane degradation (PSD) is studied. Rehydrated, dried, and deactivated Cab-O-Sil M5 samples are used as model materials for 29Si CP-MAS NMR analysis. At about 350 °C, TPDMDS yelds mainly diphenylmethylsiloxysilane, dimethyldisiloxysilane, and triphenylsiloxysilane groups. TPSA yields phenyltrisiloxysilane, diphenyldisiloxysilane, and triphenylsiloxysilane groups. At 400°C, the products formed initially are eventually replaced by methyltrisiloxysilane or phenyltrisiloxysilane groups, while a substantial number of silanol groups still remains. The possible consequences for wettability are discussed. D4 reacts with Cab-O-Sil even at 200°C, but a large number of silanol groups remains. This number decreases gradually at higher temperatures and becomes negligible above 400°C. The formation of methyltrisiloxysilane groups, which starts at 425°C, is predominant at 490°C.  相似文献   

6.
In this work, an investigation of new organosilicon hydride reagents with phenyl functional groups for deactivation and surface modification of fused silica capillary columns is described. Different reagents were tested for their ability to deactivate the fused silica surface, and actual critical surface tension measurements were made using the capillary rise method. The deactivation procedure required lower optimum temperatures than conventional methods. Deactivated capillaries and coated capillary columns were prepared and tested for reproducibility, efficiency, and surface inertness towards basic and acidic compounds at the low nanogram level.  相似文献   

7.
8.
In this study, application of a fused silica capillary column for analysis of major mutagenic heterocyclic compounds found in cooked foods was investigated.  相似文献   

9.
10.
11.
A method is described for surface deactivation and modification of fused silica capillary columns with a cyanopropyl-containing reagent. The deactivation procedure involved a dehydrocondensation reaction between a bis(cyanopropyl)methylhydropolysiloxane reagent and surface silanol groups at an optimum temperature of only 250°C. Actual critical surface tension measurements were made using the capillary rise method. Excellent deactivation for acidic and basic compounds at the low ng level, and wettability for nonpolar and polar polysiloxane stationary phases were obtained. A procedure was developed to remove acidic impurities that are present in polar stationary phases.  相似文献   

12.
13.
14.
15.
16.
17.
18.
A test mixture containing 28 compounds plus their stable isotopically labeled analogs was analyzed on a daily basis for one month during a series of routine fused silica capillary column GC/MS analyses in order to establish the precision with which retention times and responses were produced. These long-term precision data were evaluated to determine how to best predict retention times and how to best reproduce quantification. Results clearly indicate that relative retention times should be calculated using the reference compound eluted most closely to the target compound and that quantification should be based on relative response using a chemically “similar” compound.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号