首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
建立了超声波溶剂提取-气相色谱法同时测定烟草及其制品中19种有机氯农药残留。样品采用正己烷-丙酮超声提取,经Florisil固相萃取柱净化后,采用气相色谱-电子捕获检测法(GC-ECD)进行检测。结果发现,19种有机氯农药加标回收率均在72%以上,相对标准偏差(RSD)在0.1%~9.0%,能满足当前烟草中有机氯农药残留的同时快速检测要求。  相似文献   

2.
分子烙印固相萃取技术克服了传统固相萃取技术选择性差的缺陷,实现了对复杂样品中特定分析对象或杂质的选择性提取,从而大大提高了分析测试的精度和准确性,并降低了检测限。该文对分子烙印聚合物(MIPs)作为固相萃取填料从复杂的环境样品中分离、富集和纯化微量及痕量的目标化合物进行了综述,涉及的目标化合物包括杀虫剂、除草剂、兽药等各类农药残留以及重金属离子和某些生物毒素等。  相似文献   

3.
A procedure for the multiresidue determination of organochlorine pesticides and polychlorinated biphenyls in fish muscle samples has been developed. The method is based on the microwave-assisted extraction (MAE) of food samples from an acetonitrile-water (95 + 5, v/v) mixture followed by SPE cleanup of the extracts and analysis by GC with an electron capture detector. MAE operational parameters, such as the extraction solvent, temperature, and time, were optimized with respect to the extraction efficiency of the target compounds from food samples with 10-13% fat content. The chosen extraction technique allows reduction of the solvent consumption and extraction time when compared with methods already used. Acetonitrile is a good extraction solvent for low-fat matrixes (2-20% fat content), such as fish samples, because it does not significantly dissolve the highly polar proteins, salts, and sugars commonly found in food and gives high recoveries of a wide polarity range of analytes. For purification, SPE using LC-Florisil was shown to be sufficient for the removal of coextracted substances. Recoveries > 78% with RSD values < 15% were obtained for all compounds under the selected conditions. Method quantification limits were in the 5-10 microg/kg range. The method was applied to the analysis of samples of herring (Clupea harengus) purchased at the local fish market. The method is rapid and reliable for the determination of organochlorine analytes in fish muscle.  相似文献   

4.
In this study, an extraction and preconcentration technique using solid-phase extraction (SPE) along with hollow fiber (HF) has been developed as an ultra-preconcentration technique for some triazole pesticides in aqueous samples. Triazole pesticides were employed as model compounds to assess the method and were monitored by gas chromatography-flame ionization detection (GC-FID). Initially, an aqueous solution of target analytes was passed through an RP-8 SPE cartridge and then the adsorbed analytes were eluted with μL amounts of toluene. The collected elute was slowly introduced into an HF that had one end blocked. This allowed precipitation inside the lumen and pores of the HF. Finally, the obtained HF was mounted on a home-made solid-phase microextraction syringe and entered into the GC injection port for thermal desorption-GC analysis. The effect of various experimental parameters including injection port temperature, desorption time, state of HF, washing solvent, elution solvent and its volume, sample volume, etc. were investigated for finding the optimum conditions. The calibration graphs were linear in the ranges of 2-1000 ng/mL (penconazole and hexaconazole), 5-1000 ng/mL (tebuconazole), 15-1000 ng/mL (triticonazole) and the detection limits (LODs) ranged from 0.6 to 4.5 ng/mL. The enhancement factors were in the range of 870-950. The relative standard deviations (RSD%) for five repeated experiments (C=250 ng/mL of each pesticide) varied from 4.5 to 8.7%. The relative recoveries obtained for analytes in grape juice samples, spiked with different levels of each pesticide, were in the range of 87-119%.  相似文献   

5.
A solid‐phase extraction (SPE) method was developed to extract 14 pesticides simultaneously from environment samples using cigarette filter as the sorbent before gas chromatography‐mass spectrometry (GC‐MS) analysis. Parameters influencing the extraction efficiency, such as the sample loading flow rate, eluent and elution volume, were optimized. The optimum sample loading rate was 3 mL/min, and the retained compounds were eluted with 6 mL of eluent at 1 mL/min under vacuum. Good linearity was obtained for all the 14 pesticides (r2>0.99) from 0.1 to 20 μg/L for water and from 2 to 400 μg/kg for soil samples. The detection limits (signal‐to‐noise=3) of the proposed method ranged from 0.01 to 0.20 μg/L for water samples and from 0.42 to 6.95 μg/kg for soil samples. The developed method was successfully applied for determination of the analytes in real environmental samples, and the mean recoveries ranged from 76.4 to 103.7% for water samples and from 79.9 to 105.3% for soil samples with the precisions (relative standard deviation) between 2.0 and 13.6%.  相似文献   

6.
A multiresidue method for screening of emerging contaminants in aquatic environments was developed. The method was based on sample pretreatment with solid phase extraction (SPE) and analysis with an ultra performance liquid chromatograph-time-of-flight mass spectrometer (UPLC-TOF-MS). The method was optimized and tested with standard solutions of model compounds containing 84 pesticides and pharmaceuticals. Four different SPE sorbents were evaluated to gain maximum recovery for the analytes. For the final procedure a combination of two different sorbents was chosen. In spite of high matrix suppression, the method quantification limits (MQLs) were acceptable. Therefore, the method can be used for screening known target compounds. The applicability of the method for posttarget and nontarget screening will be reported later. To preliminarily assess the quantitative performance of the method, some compounds in wastewater effluent were quantified using the standard addition method. Three pesticides and eight pharmaceuticals were found in concentrations up to ~2200 ng/L.  相似文献   

7.
In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples. For sample preconcentration, the performance of a prototype programmable field extraction system (PROFEXS) was evaluated against the commercial laboratory bench Prospekt system used for method development. The Profexs is designed for the automated on-site sampling, SPE preconcentration, and storage of up to 16 samples in SPE cartridges. These cartridges are further eluted and on-line analyzed with the Prospekt coupled to the chromatographic system. In the optimized method, where completely on-line SPE-LC-MS analysis of the samples is carried out with the Prospekt in the laboratory, detection limits lower than 100 ng/L, and satisfactory precision (relative standard deviations <25%) and accuracies (recovery percentages >75%) were obtained for most investigated compounds from the analysis of spiked Milli-Q water. The extraction efficiency achieved with the Profexs was comparable to that of the Prospekt for most compounds and somewhat lower for the most apolar analytes, probably due to adsorption on the pump filters. The completely on-line optimized method was applied to the analysis of surface water, ground water and drinking water from a waterworks in Barcelona. Some pesticides and phenols were found in both surface water and groundwater at ng/L or µg/L levels, but not in the final drinking water. Di(2-ethylhexyl)phthalate (DEHP) was present in all samples investigated, including blanks. To the author's knowledge, this is the first work describing the application of a fully automated on-line SPE-LC-MS method for the simultaneous analysis of pesticides, phenols, and phthalates in water, and the second one that examines the possibilities of the prototype Profexs for automated on-site SPE preconcentration of organic pollutants from water samples.  相似文献   

8.
Summary A two-level orthogonal array design (OAD) to optimize the solid phase extraction of organochlorine pesticides is described. Parameters including eluting solvents, SPE cartridges packed with C18-bonded silica from different manufacturers, duration of air drying, pH, salinity and humic acid have been examined using OAD. This systematic approach was then used to optimize the relevant parameters required for off-line solid phase extraction of organochlorine pesticides from water. The optimized parameters were employed to perform extraction of the pesticides from natural waters.  相似文献   

9.
An analytical method was developed and validated for simultaneous quantitation of 65 pesticides, including one single solid-phase extraction (SPE) procedure in surface water by liquid chromatography coupled to tandem mass spectroscopy. Different parameters that have an influence on extraction efficiency were evaluated in this research. Different types of cartridges, elution solvents, and sorbent drying time were investigated, and the most appropriate one was selected. Moreover, various pretreatment techniques were applied to remove sediments from water without the loss of pesticides. Centrifugation was introduced as the best option at the beginning of sample preparation to resolve the clogging of the sorbent cartridges. The recoveries of all pesticides ranged from 70% to 120%, with a relative standard deviation of less than 13.7%. The feasibility of the method was evaluated on 10 surface water samples with different concentrations of sand, sediment, and particles.  相似文献   

10.
The purpose of this study is to demonstrate an application of 2-D high-performance planar chromatography-diode array detector (DAD) and HPLC-DAD after solid-phase extraction (SPE) for identification and quantitative analysis of pesticides (isoproturon, aziprotryne, hexazinone, flufenoxuron, methabenzthiazuron, procymidone, and α-cypermethrin) in Melissa officinalis L. (Labiatae) samples. The procedure described for the determination of compounds is inexpensive and can be applied to routine analysis of analytes in medical herbs' samples after preliminary cleanup and concentration by SPE. Average recoveries on C18 SPE cartridges of pesticides eluted with 5 mL tetrahydrofuran by the proposed HPLC-DAD method, before and after 2-D-high-performance planar chromatography separation of analytes from M. officinalis L. samples spiked with pesticide at a concentration level of 10 μg/g in plant material are presented. Method validation parameters for the quantification of pesticides by the proposed HPLC-DAD after SPE method are also presented.  相似文献   

11.
Summary A two-level orthogonal array design (OAD) to optimize the solid phase extraction of organochlorine pesticides is described. Parameters including eluting solvents, SPE cartridges packed with C18-bonded silica from different manufacturers, duration of air drying, pH, salinity and humic acid have been examined using OAD. This systematic approach was then used to optimize the relevant parameters required for off-line solid phase extraction of organochlorine pesticides from water. The optimized parameters were employed to perform extraction of the pesticides from natural waters.  相似文献   

12.
Triazole fungicides are pesticides widely employed in the cultivation of fruits, vegetables and grains. However, their ability to change the steroid hormone biosynthesis may result in endocrine complications for mammals, as well as changes in cholesterol and triglyceride levels and hepatotoxicity. The analysis of the triazole fungicides in superficial waters is important in order to monitor the risk for the biota. However, the use of efficient extraction procedures has been necessary in order to concentrate these pesticides before the analysis. In-disk solid-phase extraction (SPE) can be highlighted as a potential pre-concentration technique, mainly because the possibility to extract the analytes from a large sample volume, increasing the method detectability. Carbon nanotubes (CNTs) have been often used as solid extraction phase due to their high sorption capacity, surface area and internal volume, as well as mechanical, chemical and thermal stability. In this paper, we proposed the preparation of a new SPE disk impregnated with CNTs for the extraction of triazole fungicides from environmental water samples. The disks were obtained by acid corrosion of a cellulose membrane followed by its impregnation with CNTs. The developed method was validated for the analysis of triadimenol, tebuconazole and epoxiconazole, according to international validation protocols. The limits of quantification obtained for triadimenol, tebuconazole and epoxiconazole were 0.1, 0.1 and 0.05 µg L?1, respectively. The linearity ranged from 0.05 to 10.00 µg L?1 for epoxiconazole and from 0.1 to 10.00 µg L?1 for triadimenol and tebuconazole, with correlation coefficients higher than 0.999 for all of them. The precisions, expressed as relative standard deviation, were lower than 12%. The accuracies were within ?12.07% to 17.7% (expressed as relative error).  相似文献   

13.
Summary Three polymeric adsorbents, two of which had been chemically modified with different hydrophilic functional moieties and the third, which was the corresponding unmodified polystyrene-divinylbenzene (PSDVB) resin, were compared for solid-phase extraction (SPE) of several polar pesticides and phenolic compounds from water samples. The SPE system was online coupled to a liquid chromatograph with UV detector. Chemical modification of the PS-DVB resin with either 2-carboxy-3/4-nitrobenzoyl or 2,4-dicarboxybenzoyl, improved the efficiency of the SPE process by increasing polar interactions with the analytes. The adsorbent with the nitro group gave higher recoveries, mainly for the most polar analytes. This adsorbent enabled 100 mL river water to be preconcentrated to determine the target analytes in this matrix.  相似文献   

14.
The feasibility of different extraction procedures was tested and compared for the determination of 12 organophosphorus and carbamates insecticides in honey samples. In this sense, once the samples were pre-treated - essentially dissolved in hot water by stirring - and before they could be analyzed by liquid chromatography-ion trap-second stage mass spectrometry (LC-MS(2)), four different approaches were studied for the extraction step: QuEChERS, solid-phase extraction (SPE), pressurized liquid extraction (PLE) and solid-phase microextraction (SPME). The main aim of this work was to maximise the sensitivity of pesticides and to minimise the presence of interfering compounds in the extract. All pesticides were linear in the range from CC(β) to 1000× CC(β) for the four extraction methods (three orders of magnitude). Detection capabilities (CC(β)) were 0.024-1.155 mg kg(-1) with QuEChERS, 0.010-0.646 mg kg(-1) with SPE, 0.007-0.595 mg kg(-1) with PLE, and 0.001-0.060 mg kg(-1) with SPME. All the target compounds could be recovered by any of the methods, at a CC(β) fortification level ranged from 28 to 90% for the SPME. In comparison, the PLE method was the most efficient extraction method with recoveries from 82 to 104%. It was followed by the QuEChERS method with recoveries between 78 and 101% and the SPE method with recoveries between 72 and 100%. The repeatability expressed as relative standard deviation (RSDs) was below 20% for all the pesticides by any of the tested extraction methods. Results obtained applying the four extraction techniques to real honey samples are analogous.  相似文献   

15.
SPE is a commonly applied technique for preconcentration of pesticides from water samples. Microwave‐assisted extraction (MAE) technique is the extraction applied for preconcentration of different compounds from solid samples. SPE coupled with MAE is capable of preconcentrating these compounds from water samples too. This investigation was aimed at improving the efficiency of atrazine, alachlor, and α‐cypermethrin pesticide extraction from the spiked water samples applying SPE followed by MAE. In this way, MAE served for elution of pesticides from C18‐extraction disks with solvent heated by microwave energy. Various elution conditions were tested for their effects on the extraction efficiency of the SPE–MAE combined technique. Several parameters, such as elution solvent volume (mL), elution temperature (°C), and duration of elution (min), affect the extraction efficiency of the SPE–MAE coupled system and need to be optimized for the selected pesticides. In order to develop a mathematical model, 15 experiments were performed in the central composite design. The equation was then used to predict recoveries of the pesticides under specific experimental conditions. Optimization of microwave extraction was accomplished using the genetic algorithm approach. Best results were achieved using 20 mL of ethanol at 60°C. Optimal hold time was 5 min and 24 s. The SPE–MAE combination was also compared with the conventional SPE extraction technique with elution of a nonpolar or a moderately polar compound with nonpolar solvents.  相似文献   

16.
Open-vessel focused microwave (FMW) extraction with a purely aqueous carbonate solution was used for the extraction of chlorophenols from various solid matrices. After SPE on C18-bonded silica, the analytes were determined as such by LC-UV or, as their acetyl derivatives, by GC-ECD. The FMW aqueous extraction is efficient and rapid and no organic solvents are used. PCP was detected in several solid samples, with recoveries of 101-115% (RSD, 2-4%) relative to Soxhlet extraction. Similar recoveries were obtained for the other chlorophenols for spiked samples.  相似文献   

17.
A simple and sensitive method for simultaneous analysis of 43 pharmaceutical compounds in sewage sludge and sediment samples was developed and validated. The target compounds were extracted using pressurized liquid extraction (PLE) and then purified and pre-concentrated by solid phase extraction (SPE) using a hydrophilic-lipophilic balanced polymer. PLE extraction was performed on temperature of 100 °C, with methanol/water mixture (1/2, v/v) as extraction solvent. The quantitative analysis was performed by liquid chromatography tandem mass spectrometry using a hybrid triple quadrupole-linear ion trap mass spectrometer (LC-QqLIT-MS). Data acquisition was carried out in selected reaction monitoring (SRM) mode, monitoring two SRM transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the Information Dependent Acquisition (IDA) function. The method was validated through the estimation of the linearity, sensitivity, repeatability, reproducibility and matrix effects. The internal standard approach was used for quantification because it efficiently corrected matrix effects. Despite the strong matrix interferences, the recoveries were generally higher of 50% in both matrixes and the detection and quantification limits were very low. Beside the very good sensitivity provided by LC-QqLIT-MS, an important characteristic of the method is that all the target compounds can be simultaneously extracted, treated and analysed. Hence, it can be used for routine analysis of pharmaceuticals providing large amount of data. The method was applied for the analysis of pharmaceuticals in river sediment and wastewater sludge from three treatment plants with different treatment properties (i.e. capacity, secondary treatment, quality of influent waters). The analysis showed a widespread occurrence of pharmaceuticals in the sludge matrices.  相似文献   

18.
Planar chromatography with diode array scanning (TLC-DAD) and high-performance chromatography with diode array detection (HPLC-DAD) were used to screen water samples for pesticides. Pesticides were enriched from lake water samples by SPE on C18/SDB-1, C18, C18 Polar Plus and cyanopropyl (CN) cartridges. The recovery rates were high for all extraction materials except for all pesticides on CN cartridges, for which the values were lower. SPE was used not only for preconcentration of analytes but also for their fractionation. The analytes were eluted first with methanol and then with dichloromethane. Methanol eluates were analysed by HPLC-DAD, the dichloromethane eluates with TLC-DAD. The method was validated for precision, repeatability and accuracy. The calibration plots were linear between 0.1 and 50.0 microg/mL for all pesticides, the correlation coefficients, r, were between 0.9992 and 1.000 as determined by HPLC-DAD. In the TLC experiments, the best fit for the calibration lines was found when the calibration data were analysed using a second-degree polynomial regression. Calibration plots lay between 0.1 and 17 microg/spot for all pesticides, the correlation coefficients, r, were between 0.9974 and 0.9997 determined by TLC-DAD. The LOD was between 0.04 and 0.65 microg/spot (TLC-DAD) and between 0.02 and 3.68 microg/mL (HPLC-DAD).  相似文献   

19.
固相萃取气相色谱-质谱法测定蔬菜中含氮杂环农药残留   总被引:1,自引:0,他引:1  
建立了固相萃取(SPE)气相色谱-质谱(GC-MS)同时测定蔬菜中敌菌灵、噻菌灵、氟虫腈和噻嗪酮4种含氮杂环农药残留量的分析方法.蔬菜样品用乙腈匀浆提取后经弗罗里硅(Florisil)固相萃取柱净化.采用GC-MS检测,在选择离子检测(SIM)模式下以特征离子定量,用全扫描(SCAN)方法确证.方法具有良好的线性关系(R≥0.9953)和重现性(峰面积RSD≤9.1%),最低检出限(S/N=3)在3.6~1.8×10-4μg/mL之间,4种农药添加回收率在76.1%~116.4%之间,RSD≤9.8%,用于实际样品菜心的检测,结果满意.方法操作简单,灵敏度高,可作为测定各种蔬菜基质中含氮杂环农药残留量的确证方法.  相似文献   

20.
A simple off-line solid-phase extraction (SPE) method for isolation of polychlorinated biphenyls (PCBs) and selected organochlorine pesticides (OCPs) from human serum has been developed. The procedure includes denaturation of serum proteins by a mixture of water-1-propanol, application of the sample by aspiration twice repeatedly through the SPE column and elution with a mixture of n-hexane-dichlormethane. After final clean-up the compounds of interest were analysed by gas chromatography with micro-electron capture detection (GC-microECD). The recoveries achieved for PCB congeners using spiked porcine serum samples were 99-120% and for OCPs 88-115%. Relative standard deviations (RSD) ranged from 3 to 7%. The method was applied to real human serum samples and the recoveries of analytes in the serum were proportionally recalculated considering the recovery of the internal standard PCB-174. PCB-103 served as a syringe standard to correct volume of samples analysed. The aim of this study was to develop an effective off-line SPE procedure by optimization of existing SPE methods to supply laborious, solvent- and time-consuming liquid-liquid extraction (LLE) in routine analytical process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号