首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2003,15(3):183-190
The important parameters in defining the response of the portable channel biosensor described previously are explored by connecting the portable flow cell to a gravity feed flow system and using a highly defined enzyme immobilization protocol which ensures the enzyme reaction is a surface reaction. The enzyme glucose oxidase (GOD) was immobilized by covalent attachment to a self‐assembled monolayer modified gold surface. As a glucose solution flowed down the rectangular duct defined by the flow cell, it passed over the enzyme layer where the enzyme reaction produced hydrogen peroxide. The hydrogen peroxide was swept further downstream to the detector electrode. The response of such an enzyme electrode was shown to be limited by mass transport of the cosubstrate oxygen to the enzyme layer. Increasing the amount of oxygen in the sample meant the response of the biosensor became limited by the enzyme kinetics. The influence of parameters such as flow rate, height of the channel, enzyme layer length and the gap between the enzyme layer and the detector electrode were explored.  相似文献   

2.
界面微环境是影响酶催化反应及酶传感性能的关键因素. 本研究基于三维微纳米结构多孔金基底, 通过调控电极表面的亲水和疏水浸润性, 制备了具有固-液-气三相界面微环境的氧化酶电极, 并研究了界面微环境对酶催化反应动力学的影响规律. 基于所制备的三相界面多孔金结构酶电极, 反应物氧气能够从气相直接快速地传输到酶催化反应界面, 极大地提升了界面氧气浓度及其稳定性, 从而大幅度提高了氧化酶活性及酶电极响应的稳定性. 以葡萄糖为模型待测物, 基于该三相界面酶电极的电化学酶生物传感器拥有宽的线性范围、 高的灵敏度、 低的检出限以及良好的稳定性. 这类独特的三相反应界面设计为高效酶生物传感器的建构以及生物分子的精准检测提供了新思路.  相似文献   

3.
A novel film of chitosan-gold nanoparticles is fabricated by a direct and facile electrochemical deposition method and its application in glucose biosensor is investigated. HAuCl(4) solution is mixed with chitosan and electrochemically reduced to gold nanoparticles, which can be stabilized by chitosan and electrodeposited onto glassy carbon electrode surfaces along with the electrodeposition of chitosan. Then a model enzyme, glucose oxidase (GOD) is immobilized onto the resulting film to construct a glucose biosensor through self-assembly. The resulting modified electrode surfaces are characterized with both AFM and cyclic voltammetry. Effects of chitosan and HAuCl(4) concentration in the mixture together with the deposition time and the applied voltage on the amperometric response of the biosensor are also investigated. The linear range of the glucose biosensor is from 5.0 x 10(-5) approximately 1.30 x 10(-3) M with a Michaelis-Menten constant of 3.5 mM and a detection limit of about 13 microM.  相似文献   

4.
电化学酶传感器在环境污染监测中的应用   总被引:1,自引:0,他引:1  
电化学酶传感器是一种应用广泛的生物传感器,它将酶及其底物相互作用的特异性与电化学的强大分析功能相结合,已经被广泛应用于药理学、临床、食品、农业以及环境监测中。制备电化学酶传感器的关键步骤是酶的固定化,选择用于制备电化学酶传感器的合适的酶固定化方法,在传感器电子转移动力学、稳定性和重现性等方面起着主要作用。本文在阐述电化学酶传感器工作原理的基础上,简要介绍了用于电化学酶传感器制备过程中的酶固定化方法,重点讨论了电化学酶传感器在监测环境中广泛存在的有机污染物、无机污染物和重金属等方面的应用,并对电化学酶传感器的发展方向进行了展望。  相似文献   

5.
This paper presents a mathematical model of a potentiometric biosensor based on a potentiometric electrode covered with an enzyme membrane. The model is based on the reaction–diffusion equations containing a non-linear term related to theMichaelis–Menten kinetics of the enzymatic reaction. Using computer simulation the influence of the thickness of the enzyme membrane on the biosensor response was investigated. The digital simulation was performed using the finite difference technique. Results of the numerical simulation were compared with known analytical solutions.   相似文献   

6.
A new electrochemical biosensor was developed by incorporating an enzyme into a solid-paraffin-graphite-particle matrix. Tyrosinase served as model enzyme and the biosensor response was characterized with respect to its response to dopamine. The influence of different experimental parameters (tyrosinase loading, flow rate, oxygen dependence, pH, etc.) was investigated in order to optimize the biosensor performance. The electrode response was fast, reversible and linear in a large concentration domain (0.1 muM-1 mM). The enzyme-solid paraffin carbon paste electrode (CPE) showed markedly improved stability in flow injection analysis compared to the classical liquid paraffin-graphite-based biosensors. The biosensor allowed a sampling rate of 79 samples per hour, the repeatability of the injections was improved with respect to the classical CPE with a relative standard deviation of 2.2% (N = 63), and the detection limit for dopamine was 50 nM. The biosensor response to some phenol and catechol derivatives was also investigated.  相似文献   

7.
A novel biosensor, comprised of electrode of gold/multi-walled carbon nanotubes–glucose oxidase (Au/MWNTs–GOD), has been developed. The MWNTs were produced by microwave plasma enhanced chemical vapor deposition. The enzyme of GOD was immobilized using MWNTs. Performance and characteristics of the fabricated glucose biosensor were assessed with respect to response time, detection limit, pH value and storage stability. The results show that the fabricated biosensor is sensitive and stable in detecting glucose, indicating that MWNTs are a good candidate material for the immobilization of enzyme in glucose biosensor construction.  相似文献   

8.
《Electroanalysis》2003,15(7):608-612
A new type of organically modified sol‐gel/chitosan composite material was developed and used for the construction of glucose biosensor. This material provided good biocompatibility and the stabilizing microenvironment around the enzyme. Ferrocene was immobilized on the surface of glassy carbon electrode as a mediator. The characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The effects of enzyme‐loading, buffer pH, applied potential and several interferences on the response of the enzyme electrode were investigated. The simple and low‐cost glucose biosensor exhibited high sensitivity and good stability.  相似文献   

9.
Screen-printing technology for electrode fabrication enables construction of amperometric devices suitable for combination of several enzyme electrodes. To develop a biosensor array for characterisation of wastewaters, tyrosinase and horseradish peroxidase (HRP) or cholinesterase-modified electrodes were combined on the same array. The behaviour of the tyrosinase-modified electrode in the presence of hydrogen peroxide (required co-substrate for the HRP-modified electrode) and acetylthiocholine chloride (required co-substrate for cholinesterase) was studied. Performance of bi-enzyme biosensor arrays in the batch mode and in the flow-injection system are discussed.  相似文献   

10.
《Electroanalysis》2005,17(1):54-58
A disposable biosensor based on acetylcholinesterase‐functionalized acid purified multi‐wall carbon nanotubes (CNTs) modified thick film strip electrode for organophosphorus (OP) insecticides was developed. The degree of inhibition of the enzyme acteylcholinesterase (AChE) by OP compounds was determined by measuring the electrooxidation current of the thiocholine generated by the AChE catalyzed hydrolysis of acteylthiocholine (ATCh). The large surface area and electro‐catalytic activity of carbon nanotubes lowered the overpotential for thiocholine oxidation to 200 mV (vs. Ag/AgCl) without the use of mediating redox species and enzyme immobilization by physical adsorption. The biosensor detected as low as 0.5 nM (0.145 ppb) of the model organophosphate nerve agent paraoxon with good precision, electrode to electrode reproducibility and stability. Analysis of real water sample using the sensor demonstrated the feasibility of the application of the sensor for on site monitoring of OP compounds.  相似文献   

11.
We propose an electron transfer-mediated amperometric enzyme biosensor based on plasma-polymerized thin film of dimethylaminomethylferrocene (DMAMF) on a sputtered gold electrode. The DMAMF plasma-polymerized film is deposited directly onto the surface of the electrode under dry conditions. The resulting thin film not only has redox sites but also is extremely thin (approximately 20 nm), adheres well onto the substrate (electrode), has a flat surface and a highly-crosslinked network structure, and is hydrophilic in nature. Glucose oxidase is densely immobilized onto the surface of DMAMF plasma-polymerized film on the gold electrode. From the electrochemical measurement, the biosensor can cover the wide range of glucose concentration (1.3 - 81 mM) at +350 mV of applied potential. The current response of the glucose biosensor was decreased by less than 5% in an aerobic solution as compared to that in an anaerobic solution. These show that the DMAMF plasma-polymerized films play a role as the electron transfer mediators between the reaction center of enzyme and the electrode.  相似文献   

12.
We investigated a L ‐phenylalanine (L ‐phe) biosensor, functionalized through enzyme immobilization on a polymer‐blend film. The electron mediator 3,4‐dihydroxybenzaldehyde (3,4‐DHB) was employed at the electrode surface to improve direct oxidation of NADH to NAD+ and no additional reagents is required to be added to the sample solution. The bioactivated electrode was coated with a semi‐permeable cellulose acetate membrane in order to prevent dissolution of biofunctionalized polymer‐blend film. This constructed enzyme electrode is the first selective biosensor for phenylketonuria (PKU) detection. The sensitivity of the enzyme electrode was determined as 12.014 mA/M cm2. The Michaelis–Menten and current responses as well as sensitivity of the electrode showed improved values than those of previous works. This selective biosensor presented an excellent electroanalytical response for L ‐phe, with a high steady‐state current being obtained after 20 s. The sensitivity of our biodevice is quite sufficient for the purpose of PKU detection because the reference range of clinical concern for L ‐phenylalanine concentration is CL ‐phe>0.5 mM. This surface‐bioactivated enzyme electrode retained more than 80 % of its electrocatalytic activity after 16 days.  相似文献   

13.
杨绍明  林贤福 《分析试验室》2003,22(Z1):390-390
A surface-renewable glucose biosensor is reported. The glucose biosensor is developed using glucose oxidase (GOD) encapsulated in organically modified solgel glass (ORMOSIL) network in the composite matetial. The organic group in the ORMOSIL network controls the hydrophobicity of the electrode surface and thus limits the wettability of the electrode surface. The graphite powder provides the conductivity for the electrode.Ferrocenecarboxylic acid in phosphate buffer solution (pH 7.0) transfers electron between enzyme and electrode. Cyclic volammetry and amperometric measurements have been used to exmine the electrochemical behavior of glucose biosensor as shown in Fig. 1 and Fig.2. The electrode gives a linear response range of 1 -20mM glucose with a sensitivity of 3.26 μA· mM-1. The electrode can be renewed easily in reproducible manner by a simple polishing step.  相似文献   

14.
The urease enzyme of Helicobacter pylori was isolated from biopsy sample obtained from antrum big curvature cell extracts. A new urea biosensor was prepared by immobilizing urease enzyme isolated from Helicobacter pylori on poly(vinylchloride) (PVC) ammonium membrane electrode by using nonactine as an ammonium ionophore. The effect of pH, buffer concentration, and temperature for the biosensor prepared with urease from H. pylori were obtained as 6.0, 5 mM, and 25 °C, respectively. We also investigated urease concentration, stirring rate, and enzyme immobilization procedures in response to urea of the enzyme electrode. The linear working range of the biosensor extends from 1 × 10(-5) to 1 × 10(-2) M and they showed an apparent Nernstian response within this range. Urea enzyme electrodes prepared with urease enzymes obtained from H. pylori and Jack bean based on PVC membrane ammonium-selective electrode showed very good analytical parameters: high sensitivity, dynamic stability over 2 months with less decrease of sensitivity, response time 1-2 min. The analytical characteristics were investigated and were compared those of the urea biosensor prepared with urease enzyme isolated from Jack bean prepared at the same conditions. It was observed that rapid determinations of human serum urea amounts were also made possible with both biosensors.  相似文献   

15.
Glucose sensitive biosensor containing pyrroloquinoline quinone (PQQ)‐dependent glucose dehydrogenase immobilized on Prussian blue (PB)‐modified graphite electrode was designed. Properties of the biosensor were investigated in the cathodic and anodic response detection regions. It was shown, that anodic response of the biosensor is sum of two signals: direct electron transport from reduced PQQ to the electrode and by formation of the PQQ‐oxygen‐PB‐carbon ternary complex. Cathodic response of the biosensor is based on the oxidation of the reduced PQQ by PB‐oxygen‐PB complex. Electrochemical regeneration of the enzyme does not produce free hydrogen peroxide.  相似文献   

16.
《Electroanalysis》2017,29(10):2300-2306
High‐performance biosensors were fabricated by efficiently transferring enzyme onto Pt electrode surfaces using a polydimethylsiloxane (PDMS) stamp. Polypyrrole and Nafion were coated first on the electrode surface to act as permselective films for exclusion of both anionic and cationic electrooxidizable interfering compounds. A chitosan film then was electrochemically deposited to serve as an adhesive layer for enzyme immobilization. Glucose oxidase (GOx) was selected as a model enzyme for construction of a glucose biosensor, and a mixture of GOx and bovine serum albumin was stamped onto the chitosan‐coated surface and subsequently crosslinked using glutaraldehyde vapor. For the optimized fabrication process, the biosensor exhibited excellent performance characteristics including a linear range up to 2 mM with sensitivity of 29.4±1.3 μA mM−1 cm−2 and detection limit of 4.3±1.7 μM (S/N=3) as well as a rapid response time of ∼2 s. In comparison to those previously described, this glucose biosensor exhibits an excellent combination of high sensitivity, low detection limit, rapid response time, and good selectivity. Thus, these results support the use of PDMS stamping as an effective enzyme deposition method for electroenzymatic biosensor fabrication, which may prove especially useful for the deposition of enzyme at selected sites on microelectrode array microprobes of the kind used for neuroscience research in vivo .  相似文献   

17.
《Analytical letters》2012,45(6):859-877
Abstract

A model of an oximeter-based two-substrate enzyme electrode is presented. The simplifications of the general model lead to a solution to differential equations describing the influence of the rate of the enzyme reaction in combination with the diffusion phenomena on measurable oxygen flux. Both transient phase and steady state conditions for experimental data can be considered within the frames of the model and provide possibilities for the calibration of the biosensor. The optimal parameters for the biosensor calibration can be used in practical design of enzyme electrodes.  相似文献   

18.
Studies on the immobilization of acetylcholinesterase onto a SAM gold electrode and the use of the fabricated biosensor for the determination of carbaryl and parathion are presented. The influence of pH, ionic strength, enzyme loading and concentration of glutaraldehyde on the response of the biosensor was investigated . The amperometric biosensor developed in this study provided linearity to parathion and carbaryl in the 2.0 a 30.0×10?6 mol L?1 concentration range. The detection limits under the optimum working conditions were found to be 9.3 μg L?1 for parathion and 9.0 μg L?1 for carbaryl. The enzyme electrode was found to be stable for 7 days.  相似文献   

19.
在碳纳米管(CNTs)和K3Fe(CN)6修饰的铂电极上吸附固定胆碱氧化酶,以鲁米诺为发光试剂,研制了胆碱电化学发光(ECL)生物传感器。CNTs可有效提高电极表面的电荷传输能力、提高电极表面的生物相容性和对酶分子的固载能力;K3Fe(CN)6对酶活性具有激活作用,同时对H2O2增敏的鲁米诺ECL有增强作用,均有利于提高传感器的检测灵敏度。研究表明,将CNTs分散液与K3Fe(CN)6混合,滴涂修饰在Pt电极上,吸附固定胆碱氧化酶,制备传感器。此传感器在含有8×10-6mol/L鲁米诺的磷酸盐缓冲液(pH7.4)、30℃条件下产生的ECL强度与胆碱浓度在1×10-7~4×10-3mol/L范围内呈线性关系,相关系数为0.994,检出限为1.2×10-8 mol/L。此生物传感器应用于鼠血样中胆碱的测定,测得结果为2.68 mg/L,平均回收率为101.1%。传感器具有快速、稳定和重现性好等特点,有望应用于常规分析。  相似文献   

20.
Multiwalled carbon nanotube (CNT) modified glassy carbon electrode immobilized with horseradish peroxidase (HRP) in Nafion coating showed direct electron transfer between HRP enzyme and the CNT‐modified electrode. A mediator‐free bienzyme glucose biosensor based on horseradish peroxidase and glucose oxidase was constructed. The bienzyme biosensor exhibited a high sensitivity for glucose detection at zero applied potential.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号