首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The concentrations of Cd, Co, Cu, Mn, Ni, Pb, and Zn in natural and sea waters are too low to be directly determined with by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GFAAS). Specific sample preparations are requested that make possible the determination of these analytes by preconcentration or extraction. These techniques are affected by severe problems of sample contamination. In this work Cd, Co, Cu, Mn, Ni, Pb, and Zn were determined by inductively coupled plasma mass spectroscopy (ICP-MS) or by atomic absorption spectrometry, in fresh and seawater samples, after on-line preconcentration and following solvent elution with a flow injection system. Bonded silica with octadecyl functional group C18, packed in a microcolumn of 100-μl capacity, was used to collect diethyldithiocarbamate complexes of the heavy metals in aqueous solutions. The metals are complexed with a chelating agent, adsorbed on the C18column, and eluted with methanol directly in the flow injection system. The methanolic stream can be addressed to FAAS for direct determination of Cu, Ni, and Zn, or collected in a vial for successive analysis by GFAAS. The eluted samples can be also dried in a vacuum container and restored to a little volume with concentrated HNO3and Milli-Q water for analysis by ICP-MS or GFAAS.  相似文献   

2.
The use of rice husks as an alternative adsorbent in an on-line preconcentration system for Cd (II) and Pb (II) determination by flame atomic absorption spectrometry (FAAS) is described. The potential of rice husks as a natural adsorbent was evaluated as a material modified with 0.75 mol l−1 NaOH solution and in the unmodified form. For this task, several techniques such as spectroscopy and thermogravimetry were used for elucidation of possible functional groups responsible for the uptake of Cd (II) and Pb (II). Furthermore, based on adsorption studies and adsorption isotherms applied to the Langmüir model, it was possible to verify that modified rice husks present a higher adsorption capacity for both metals. After establishing this material as a promising natural adsorbent, it was used for on-line preconcentration of Cd (II) and Pb (II) metals. The multivariate optimisation of chemical and flow variables was performed by using a full factorial design (24) including the following factors: preconcentration time, preconcentration flow rate, concentration and volume of eluent. The optimum pH values used for on-line preconcentration were taken from prior univariate experiments. Under optimised conditions for Cd (II) determination (4 min of preconcentration at a 6 ml min−1 preconcentration flow rate, in which comprises 24 ml of preconcentration volume, 200 μl elution volume and 1.0 mol l−1 HNO3 solution as eluent), the system achieved a detection limit of 1.14 μg l−1 and an enrichment factor of 72.4. Similar conditions were used for Pb (II) determination (4 min of preconcentration, 6 ml min−1 preconcentration flow rate, 300 μl elution volume and 1.0 mol l−1 HNO3 solution as eluent) from which a detection limit of 14.1 μg l−1 and enrichment factor of 46.0 were achieved. Also, rice husks have been shown to be a homogeneous and stable adsorbent in which more than 100 preconcentration/elution cycles provide a relative standard deviation (RSD) of less than 6.0% on the analytical signal. The satisfactory accuracy of the method developed was obtained by using spiked water samples (mineral water and lake water) and spiked red wine samples. These values were confirmed by electrothermal atomic absorption spectrometry (ETAAS). The certified reference material [pig kidney (CRM 186)] and the reference material [beech leaves (CRM 100)] were also used.  相似文献   

3.
A sol-gel thiocyanatopropyl-functionalized silica sorbent was synthesized and employed for an automated on-line microcolumn preconcentration platform as a front-end to inductively coupled plasma atomic emission spectroscopy (ICP-AES) for the simultaneous determination of Cd(II), Pb(II), Cu(II), Cr(III), Co(II), Ni(II), Zn(II), Mn(II), Hg(II), and V(II). The developed system is based on an easy-to-repack microcolumn construction integrated into a flow injection manifold coupled directly to ICP-AES’s nebulizer. After on-line extraction/preconcentration of the target analyte onto the surface of the sorbent, successive elution with 1.0 mol L−1 HNO3 was performed. All main chemical and hydrodynamic factors affecting the effectiveness of the system were thoroughly investigated and optimized. Under optimized experimental conditions, for 60 s preconcentration time, the enhancement factor achieved for the target analytes was between 31 to 53. The limits of detection varied in the range of 0.05 to 0.24 μg L−1, while the limits of quantification ranged from 0.17 to 0.79 μg L−1. The precision of the method was expressed in terms of relative standard deviation (RSD%) and was less than 7.9%. Furthermore, good method accuracy was observed by analyzing three certified reference materials. The proposed method was also successfully employed for the analysis of environmental water samples.  相似文献   

4.
Rojas FS  Ojeda CB  Pavón JM 《Talanta》2006,70(5):979-983
A flow injection (FI) system was used to develop an efficient on-line sorbent extraction preconcentration system for palladium by graphite furnace atomic absorption spectrometry (GFAAS). The investigated metal was preconcentrated on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The palladium is eluted with 40 μl of HCl 4 M and directly introduced into the graphite furnace. The detection limit for palladium under the optimum conditions was 0.4 ng ml−1. This procedure was employed to determine palladium in different samples.  相似文献   

5.
The use of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of trace elements in Al2O3 powders is reported. Special interest is given to a preconcentration of the trace elements by on-line coupling of chromatography to ICP-MS. This is based on the complexation of Co, Cu, Cr, Fe, Ga, Mn, Ni, V and Zn with hexamethylene-dithiocarbamate (HMDC), their preconcentration on a C18 RP column by reversed phase liquid chromatography and their elution with CH3OH-H2O mixtures. A direct coupling of the HPLC system to the ICP-MS has been realized by high pressure pneumatic nebulization using desolvation. With the Chromatographie method developed, removal of the AI by at least 99% was achieved. For the trace elements V, Fe, Ni, Co, Cu and Ga, high and reproducible recoveries (ranging from 96–99%) were reached. The method developed has been shown to considerably enhance the power of detection as compared with direct procedures, namely down to 0.02–0.16 ( for V and Fe, respectively. The possibilities of the method are shown by the determinations of V, Mn, Fe, Ni, Co, Cu, Zn and Ga at the μg/g level in A12O3 powders. The accuracy of the method at the 0.06 to 9.0 level for Co and Fe, respectively, is demonstrated by a comparison with results of independent methods from the literature.  相似文献   

6.
Summary A method is described for the determination of arsenic(III) and arsenic(V) in water samples. The sample (adjusted to pH 2.5 to 3.5 with HCl or NaOH) is passed through a chromatographic column filled with inert support modified with the organotin reagent (C8H17)2SnCl2. Under these conditions arsenate is quantitatively retained, while arsenite is not. Arsenate is eluted from the column with 2 mol/l HCl (1–2 ml). Both effluate [As(III)] and eluate [As(V)] are analyzed by flame or graphite furnace AAS. The method was applied to the analysis of waste waters from a metallurgical plant and potable water from the same region. Recoveries are in the range of 85–115%.  相似文献   

7.
This paper presents a method whereby trace elements in NH4Cl-NH3 medium are adsorbed on activated carbon in a micro-flow-injection (FI) semi-online sorbent extraction preconcentration system and then determined by graphite furnace atomic absorption spectrometry (GFAAS). The analytical performance of the proposed method for determining Cd, Mn and Pb was studied. A microcolumn packed with activated carbon was used as a preconcentration column (PCC). The metals to be determined were preconcentrated onto the column for 60 s and then rinsed with 0.02% (v/v) HNO3 and eluted with 30 μl of 2 mol l−1 HNO3. Compared with the direct injection of 30 μl of aqueous sample solution, enrichment factor of 32, 26, and 21 and detection limits (3σ) of 0.4, 4.7, and 7.5 ng l−1 for Cd, Mn and Pb, respectively, were obtained with 60 s sample loading at 3.0 ml min−1 for sorbent extraction, 30 μl of eluate injection, and peak area measurement. The precisions (RSD, n=6) were 2.8% at the 0.05 μg l−1 level for Cd, 3.0% at the 0.3 μg l−1 level for Mn, and 3.1% at the 0.5 μg l−1 level for Pb. The experimental results indicate that the procedure can eliminate the fundamental interferences caused by alkali and alkaline earth metals and the application of it to the determination of Cd, Mn and Pb in some water samples is successful.  相似文献   

8.
Vanadium in Italian waters: monitoring and speciation of V(IV) and V(V)   总被引:1,自引:0,他引:1  
In this work, a highly sensitive method was developed to separate vanadium (IV) from vanadium (V), which are both contained in water at trace levels. A suitable strong anionic exchange column (SAX) loaded with disodium ethylendiaminetetraacetic acid (Na2EDTA) was used to trap both vanadium species dissolved in 10–100 ml of water at pH 3. The vanadyl ion was selectively eluted by means of 15 ml of an aqueous solution containing Na2EDTA, tetrabutylammonium hydroxide (TBA+OH), and isopropanol (iPr-OH) and was subsequently determined by atomic absorption spectroscopy with electrothermal atomization. The concentration of vanadate ion was calculated by subtracting the vanadyl concentration from the total concentration of vanadium. The optimal conditions for a selective elution were evaluated. The recovery of vanadium (IV) was 95% or better. The proposed method provides a simple procedure for the speciation of vanadium in aqueous matrices. The collection of the two forms could easily be carried out at the sampling site. Therefore, the risk of changing the concentration ratio between vanadium species was widely reduced. The detection limits were 1 μg/l for both species, when a 10-ml sample was eluted through the column. The method was applied successfully to vanadium speciation on different kinds of Italian volcanic water: Mount Etna (Sicily), Lake Bracciano and Castelli Romani (Latium).  相似文献   

9.
Arsenic(III) can be quantitatively extracted using sodium diethyldithiocarbamate (NaDDTC) as the complexing agent and C18 reversed phase packing as the column material for solid phase extraction. Arsenic(V) must be reduced to its trivalent oxidation state prior to extraction. A mixture of sodium sulphite, hydrochloric acid, sodium thiosulphate and potassium iodide was found to be optimum for on-line reduction. When the sorbent extraction is carried out without and with the addition of the reduction mixture, arsenic(III) and total arsenic can be determined sequentially by graphite furnace atomic absorption spectrometry with detection limits (3 σ) of 0.32 ng for As(III) and 0.43 ng for total arsenic. A 7.6-fold enhancement in peak area compared to direct injection of 40 μl samples was obtained after 60 s preconcentration. Results obtained for sea water standard reference materials, using aqueous standards for calibration, agree well with certified values. A precision of 5.5% RSD was obtained for total arsenic in a sea water sample (1.65 As). Results obtained for synthetic mixtures of trivalent and pentavalent arsenic agreed well with expected values.  相似文献   

10.
Summary Traces of molybdenum in sea water have been preconcentrated by anion-exchange from acidified samples in the presence of sodium azide. Molybdenum adsorbs strongly on a column of Bio-Rad AG 1 (Cl) and can be stripped easily by elution with 2 mol/l NH4Cl — 2 mol/l NH4OH solution. Molybdenum in the effluent is determined by graphite furnace atomic absorption spectrometry. The combined method allows to determine traces of molybdenum in sea water as well as non-saline water on a 100 ml sample basis. The method gives a relative standard deviation of better than 8% at a molybdenum level of 10 g 1–1 of sea water.
Bestimmung von Molybdänspuren in Meereswasser mit Hilfe einer Kombination von Anionenaustausch und elektrothermischer Atomabsorptionsspektrometrie
  相似文献   

11.
A flow injection (FI) on-line preconcentration procedure by using a nanometer-sized alumina packed micro-column coupled to inductively coupled plasma mass spectrometry (ICP-MS) was described for simultaneous determination of trace metals (V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb) in the environmental samples. The effects of pH value, sample flow rate, preconcentration time, and interfering ions on the preconcentration of analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the nanometer-sized alumina for V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb were found to be 11.7, 13.6, 15.7, 9.5, 12.2, 13.3, 17.1, 17.7 and 17.5 mg g−1, respectively. With 60 s preconcentration time and 60 s elution time, an enrichment factor of 5 and the sampling frequency of 15 h−1 were obtained. The proposed method has been applied to the determination of trace metals in environmental certified reference materials and natural water samples with satisfactory results.  相似文献   

12.
A flow injection procedure for the separation and pre-concentration of inorganic arsenic based on the complexation with ammonium diethyl dithiophosphate (DDTP) and sorption on a C-18 bonded silica gel minicolumn is proposed. During the sample injection by a time-based fashion, the As3+-DDTP complex is stripped from the solution and retained in the column. Arsenic(V) and other ions that do not form complexes are discarded. After reduction to the trivalent state by using potassium iodide plus ascorbic acid, total arsenic is determined by electrothermal atomic absorption spectrometry (ETAAS). Arsenic(V) concentration can be calculated by difference. After processing 6 ml sample volume, the As3+-DDTP complexes were eluted directly into the autosampler cup (120 μl). Ethanol was used for column rinsing. Influence of pH, reagent concentration, pre-concentration and elution time and column size were investigated. When 30 μl of eluate plus 10 μl of 0.1% (w/v) Pd(NO3)2 were dispensed into the graphite tube, analytical curve in the 0.3–3 μg As l−1 range was obtained (r=0.9991). The accuracy was checked for arsenic determination in a certified water, spiked tap water and synthetic mixtures of arsenite and arsenate. Good recoveries (97–108%) of spiked samples were found. Results are precise (RSD 7.5 and 6% for 0.5 and 2.5 μg l−1, n=10) and in agreement with the certified value of reference material at 95% confidence level.  相似文献   

13.
A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometer. The combination results in an integrated system for the determination of trace amounts of heavy metals. Silica bonded with octadecyl functional groups (C18) was used as a sorbent in a 15-μL conical microcolumn. The metals to be determined were preconcentrated as diethyl dithiocarbamate chelates onto the column for 60 s and then rinsed with deionized water and eluted with 40 μL of ethanol. Compared with direct injection of 40 μL of aqueous sample solution, enrichment factors of 30, 32, and 29 and detection limits (3ς) of 7.8, 12.8, and 3.9 ng/L for cobalt, nickel, and lead, respectively, were obtained with 60-s sample loading at 3.0 mL/min for sorbent extraction, 40 μL of eluate injection, and peak area measurement. The results obtained for trace amounts of cobalt, nickel, and lead in reference materials showed that there were no significant differences between the certified and determined values.  相似文献   

14.
The anion-exchange behaviour of chitosan toward metavanadate was studied in salt solutions at different pH values. Filtered and acidified sea water was passed through a 500-mg chitosan column. Vanadium was determined by atomic absorption spectrometry with a graphite furnace and a deuterium background corrector on 5-mg aliquots of the homogenized column. The method was assessed for the 0.2–12.0 μg V 1-1 interval on the basis of the linear response for proportional amounts of vanadium in saline solutions and sea water and in the absence of interferences from smoke during atomization. Two sea-water samples gave 0.71±0.09 and 0.52±0.04 μg V 1-1.  相似文献   

15.
An innovative procedure for the on-line coupling of ion chromatography with graphite furnace atomic absorption spectrometry is described, which is particularly effective for the determination of trace metals in seawater samples. The Capillary Injection Device (CID) is used as an interface which allows the eluent to be transferred from the chromatographic column into the graphite tube at a flow rate of as high as 2 ml/min. The analytical procedure is based on the metal complex formation with 8-hydroxyquinoline in the sample solution, followed by the preconcentration of the complexes in a chromatographic column packed with XAD-2 resin. The complexes were then eluted from the column with methanol, and quantitatively injected into the furnace. The procedure was validated by determining cadmium and lead in certified reference seawater samples at a level of 30–40 pg/g, with a typical reproducibility of 10% and an accuracy of better than 5%. Finally, it was tested on a real sample of seawater. Due to the high reproducibility, a pg/g concentration level can be measured.  相似文献   

16.
Silica-supported hierarchical graphitic carbon sheltering cobalt nanoparticles Co-HGC@SiO2 (1) were prepared by pyrolysis at 850 °C of [Co(phen)(H2O)4]SO4·2H2O complex with silica in the presence of pyrene as a carbon source under nitrogen atmosphere. Nanocomposites (2) and (3) were obtained by acid treatment of (1) with HCl and HF acid, respectively. The nanocomposites showed rough hierarchical carbon microstructures over silica support decorated with irregular cobalt nanospheres and nanorods 50 to 200 nm in diameter. The nanoparticles consist of graphitic shells and cobalt cores. SEM, EDAX and TEM elemental mapping indicate a noticeable loss of cobalt in the case of (2) and loss of cobalt and silica in the case of (3) with an increase in porosity. Nanocomposite (3) showed the highest BET surface area 217.5 m2g−1. Raman spectrum shows defect D-band and graphitic G-band as expected in carbon nanostructures. PXRD reveals the presence of cobalt(0) nanoparticles. XPS indicates the presence of Co(II) oxides and the successful doping of nitrogen in the nanocomposites. Moreover, TEM elemental mapping provides information about the abundance of Si, Co, C, N and S elements in zones. Nanocomposite (1) showed maximum uptake capacity of 192.3 and 224.5 mg/g for crystal violet CV and methyl orange MO dyes, respectively. Nanocomposite (2) showed a capacity of 94.1 and 225.5 mg/g for CV and MO dyes, respectively. Nanocomposite (4) obtained after treatment of (1) with crystal violet proved successful adsorption of CV. Co-HGC (5) prepared without addition of silica has a capacity for CV equal to 192 mg/g, while it is 769.2 mg/g with MO. Electrostatics and π–π interactions of graphite and cobalt species in the nanocomposites with aromatic rings of cationic and anionic dyes are responsible for the adsorption. Yan et al. was the best model to describe column kinetics. The thomas column adsorption model showed that the maximum uptake capacity of (1) was 44.42 mg/g for CV and 32.62 mg/g for MO. for a column packed with 0.5 gm of (1) and dye concentration of 100 mg/L at a flow rate of 1 mL/min. The column was recycled three times with no noticeable clogging or degradation of nanocomposites. Thus, Co-HGC@SiO2 adsorbents can be used efficiently to treat water contaminated with cationic and anionic dyes.  相似文献   

17.
A system for molybdenum separation and enrichment aiming its determination in water and biological samples by graphite furnace atomic absorption spectrometry (GFAAS) is proposed. The procedure is based on the sorption of the molybdenum (VI) thiocyanate complex onto a mini-column packed with polyurethane foam (PUF). The elution is accomplished by a 3.0 mol l−1 nitric acid solution. Flow variables were optimized and an enrichment factor of 10 as well as a limit of detection (LOD) (3 s) of 0.08 μg l−1 in the sample solution were achieved. The coefficient of variation showed values of 3 and 2% for molybdenum solutions of 2.0 and 10.0 μg l−1, respectively. The accuracy of the method was confirmed by the good concordance between found and certified values in the analysis of certified reference materials (CRMs) (CASS-3 Nearshore Seawater, NIST 1547 Peach Leaves, NIST 1515 Apple Leaves and NIST 1572 Citrus Leaves). The procedure was also applied for the molybdenum determination in mineral waters as well as in produced water samples. The results obtained for the mineral water samples compared well with those obtained by ICP-MS. Concerning the produced water samples, in spite of their large salinity, recoveries of 90 to 120% at the 1 μg l−1 were observed.  相似文献   

18.
《Microchemical Journal》2004,78(1):71-76
Thiamine (vitamin B1) was determined in human serum and urine by HPLC with fluorimetric detection of its oxidation product, thiochrome. The samples were injected directly into the chromatographic system without previous treatment or dilution. A column filled with an ultra-high molecular weight surface-modified polyethylene (PE) was able to separate matrix components from analyte and also to allow a good chromatographic resolution of thiamine. The interaction of thiamine, thiocrome and both matrices (serum and urine) with PE was studied off- and on-line to determine the optimal procedure for vitamin B1 determination. When carried off-line, matrix adsorption yield was 49 mg serum proteins/g polymer and components of 1000 μl urine/g polymer. In an on-line arrangement, the yield dropped to 10 mg/g and 150 μl/g, respectively. The matrix/analyte separation was carried out in an on-line procedure on a 50×4.6-mm, 25-μm PE column, using a water-sodium phosphate-methanol gradient elution. Part of the matrix was eluted within the first 2 min and thiamine after 3.8 min. The rest of the matrix retained on the column was eluted after thiamine at the last step of the gradient elution. Analysis time was 12 min. The within-day and day-to-day precision gave C.V. varying from 3.6% to 14.5% and recoveries from spiked samples were in the range of 84.8-98.8%.  相似文献   

19.
Methods are described for the determination of ultratrace amounts of copper and cadmium in seawater by graphite furnace atomic absorption spectrometry with flow-injection, microcolumn preconcentration. A new type of C18 column loaded with sodium diethyldithiocarbamate (sodium-DDC) was used to extract copper and cadmium from seawater as the DDC chelates. The analytical effects of the pH of the mixture of the sample and sodium-DDC solutions and the concentration of the chelating reagent were studied. Sodium-DDC-loaded columns and unloaded C18 columns with different shapes and volumes were compared. To determine copper in seawater, a simple aqueous calibration was made with a mixture of palladium and magnesium nitrate as a matrix modifier, while for cadmium no matrix modifier was necessary. This method required only small seawater volumes, 600 and 400 μl for the determination of copper and cadmium respectively, with preconcentration factors of 15-fold for copper and 10-fold for cadmium. Detection limits for the preconcentration of aqueous solutions of copper and cadmium were 0.024 and 0.004 μg liter−1 (3σ), respectively. Results for determinations of copper and cadmium in National Research Council of Canada, CASS-2, Nearshore Seawater Reference Material showed no significant differences between the certified values and the measured values, based on Student′s t test at the 95% confidence level. The relative standard deviations of the various measurements varied between 2 and 8%.  相似文献   

20.
Summary A flow-system utilizing a miniature column packed with silica-immobilized 8-hydroxyquinoline (I-8-HOQ) was used for the preconcentration of Cd, Pb, Zn, Cu, Fe, Mn, Ni, and Co from seawater prior to their determination by graphite furnace atomic absorption spectrometry (GFAAS). Enrichment factors sufficient to permit the analysis of an open ocean seawater reference material using 50 ml sample volumes (100 ml for Co determinations) were obtained. Recoveries of the above elements from seawater averaged 93% (range 87–97%) with absolute blanks ranging between 0.04 ng (Ni) and 4.0 ng (Fe). Estimated detection limits for these elements vary from 0.2 ng l–1 (Co) to 40 ng l–1 (Fe) based on a 50 ml sample volume (100 ml for Co).
Bestimmung von Spurenmetallen in Meereswasser durch Graphitofen-AAS mit Anreicherung an Kieselgel-immobilisiertem 8-Hydroxychinolin in einem Durchflu\system