首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel three-axis gradient set and RF resonator for orthopedic MRI has been designed and constructed. The set is openable and may be wrapped around injured joints. The design methodology used was the minimization of magnetic field spherical harmonics by simulated annealing. Splitting of the longitudinal coil presents the major design challenge to a fully openable gradient set and in order to efficiently design such coils, we have developed a new fast algorithm for determining the magnetic field spherical harmonics generated by an arc of multiturn wire. The algorithm allows a realistic impression of the effect of split longitudinal designs. A prototype set was constructed based on the new designs and tested in a 2-T clinical research system. The set generated 12 mT/m/A with a linear region of 12 cm and a switching time of 100 micros, conforming closely with theoretical predictions. Preliminary images from the set are presented.  相似文献   

2.
In standard cylindrical gradient coils consisting of a single layer of wires, a limiting factor in achieving very large magnetic field gradients is the rapid increase in coil resistance with efficiency. This is a particular problem in small-bore scanners, such as those used for MR microscopy. By adopting a multi-layer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favourable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. Previously this approach has been applied to the design of unshielded, longitudinal, and transverse gradient coils. Here, the multi-layer approach has been extended to allow the design of actively shielded multi-layer gradient coils, and also to produce coils exhibiting enhanced cooling characteristics. An iterative approach to modelling the steady-state temperature distribution within the coil has also been developed. Results indicate that a good level of screening can be achieved in multi-layer coils, that small versions of such coils can yield higher efficiencies at fixed resistance than conventional two-layer (primary and screen) coils, and that performance improves as the number of layers of increases. Simulations show that by optimising multi-layer coils for cooling it is possible to achieve significantly higher gradient strengths at a fixed maximum operating temperature. A four-layer coil of 8 mm inner diameter has been constructed and used to test the steady-state temperature model.  相似文献   

3.
A series of designs is presented for restricted length, whole-body, shielded gradient coils. By using the real space optimization technique, simulated annealing (SA), it is possible to produce viable gradient sets with a length-to-diameter ratio (LDR) of just 1.0. Radially remote return paths for the transverse coils aid in producing such short coils. While the linear regions of such coils cannot be as large as longer coils, they produce homogeneous linear regions suitable for use in whole-body imaging. The coil sets are well shielded even at such small LDRs.  相似文献   

4.
A method is described for design of gradient coils of unconventional geometry for MRI that is based on the superpositions of magnetic fields arising from individual current elements calculated by the Biot-Savart Law. Use of an optimization method based on a genetic algorithm enables a wide diversity in the shapes of coil that can be modeled. To exemplify this a two axis, biplanar gradient set is presented; this geometry offers good access for rectangular objects whilst holding the coils closer to the region of interest than is possible for cylindrical configurations. The inner dimensions of the gradient set were 40.0 x 24.4 x 40.0 cm and the gradient efficiencies were 0.3 and 0.4 mT m(-1) A(-1) in the z- and y- directions respectively over a 15 cm diameter region. Correction of signals arising from regions for which gradient linearity was not optimized was successful for the monotonic region within the set; the largest cuboid from which the MR signal could be processed to produce an undistorted image is of dimensions 36.3 x 17.2 x 24.4 cm.  相似文献   

5.
We present an optimized uniplanar magnetic resonance gradient design specifically tailored for MR imaging applications in developmental biology and histology. Uniplanar gradient designs sacrifice gradient uniformity for high gradient efficiency and slew rate, and are attractive for surface imaging applications where open access from one side of the sample is required. However, decreasing the size of the uniplanar gradient set presents several unique engineering challenges, particularly for heat dissipation and thermal insulation of the sample from gradient heating. We demonstrate a new three-axis, target-field optimized uniplanar gradient coil design that combines efficient cooling and insulation to significantly reduce sample heating at sample-gradient distances of less than 5 mm. The instrument is designed for microscopy in horizontal bore magnets. Empirical gradient current efficiencies in the prototype coils lie between 3.75 G/cm/A and 4.5 G/cm/A with current and heating-limited maximum gradient strengths between 235 G/cm and 450 G/cm at a 2% duty cycle. The uniplanar gradient prototype is demonstrated with non-linearity corrections for both high-resolution structural imaging of tissue slices and for long time-course imaging of live, developing amphibian embryos in a horizontal bore 7 T magnet.  相似文献   

6.
Two designs (one rectangular, one elliptical) are proposed as efficient alternatives to noncylindrical birdcage RF coils. These designs are based on the slotted-tube resonator and their performance relies on the natural current distribution in the conductors due to the eddy current effects at high frequencies. A Finite element method program, solving the full set of Maxwell's equations, has been employed to accurately characterize and optimize the field homogeneity of the proposed noncylindrical coils. The optimum configuration of each design is presented, taking into account the effect of the RF shield. The proposed designs are compared to several configurations presented in the literature. Two coils (one rectangular, one elliptical) have been constructed and tested in a 0.6 T imaging system. A rectangular coil has been built to operate at 300 MHz. MR images substantiate the usefulness of these coils.  相似文献   

7.
A set of plate form three-dimensional magnetic gradient coils was developed and used in electron spin resonance imaging (ESRI) experiment. The coils were processed with whole copper plates instead of wound with copper wires, which made its structure so compact that it was much thinner and smaller comparing to those traditionally used in ESRI. The coil set had a pie-like appearance of which the total thickness was only 14 mm and the outer diameter was 250 mm. The efficiency of the coils could be greater than 10 mT/m/A when distance between the two side-pieces was 63 mm. A maximum gradient strength of more than 200 mT/m could be obtained with driving current of about 20 A in each dimension coil. The spatial linearity was better than 5% in all three dimensions within the available spatial linearity area of larger than a sphere of 40 mm in diameter. The stability of the gradients strength could reach the level of 10(-5). An imaging resolution of better than 1 mm could be achieved with the coil set. Some preliminary practical imaging results show that the developed gradient coil set is suitable for L-band ESRI experiment of biological samples or even in vivo small animals.  相似文献   

8.
A four-element phased array coil for MR imaging of the knee was designed, built and tested for clinical use at 1.5 Tesla. In routine imaging, it provides over twofold increase in signal-to-noise (SNR) compared to two commercially available knee coils, and supports higher spatial image resolution. The phased array knee coil was also tested for its compatibility with parallel MR imaging that reduces imaging time by several folds over conventional MR technique. Results obtained using SiMultaneous Acquisition of Spatial Harmonics (SMASH) technique shows that our phased array knee coil can be used with parallel MR imaging. These improvements may enhance knee diagnosis with higher image quality and reduced scan time.  相似文献   

9.
In standard cylindrical gradient coils consisting of wires wound in a single layer, the rapid increase in coil resistance with efficiency is the limiting factor in achieving very large magnetic field gradients. This behavior results from the decrease in the maximum usable wire diameter as the number of turns is increased. By adopting a multilayer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favorable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. By extending the theory used to design standard cylindrical gradient coils, we have developed mathematical expressions which allow the design of multilayer coils, and the evaluation of their performance. These expressions have been used to design a four-layer,z-gradient coil of 8 mm inner diameter, which has an efficiency of 1.73 Tm−1A−1, a resistance of 1.8 Ω, and an inductance of 50 μH. This coil produces a gradient which deviates from linearity by less than 5% within a central cylindrical region of 4.5 mm length and 4.5 mm diameter. A coil has been constructed from this design and tested in simple imaging and pulsed gradient spin echo experiments. The resulting data verify the predicted coil performance, thus demonstrating the advantages of using multilayer coils for experiments requiring very large magnetic field gradients.  相似文献   

10.
Fast Optimization of a Biplanar Gradient Coil Set   总被引:1,自引:0,他引:1  
This work presents an approach for fast optimization of gradient coils, using the simulated annealing method. The shielding condition derived from a target field method and the analytical evaluation of the fields produced by simple geometries were used to reduce the computing time. This method is applied to the optimization of a shielded biplanar gradient coil set. Efficiency, inductance, and homogeneity of the gradient fields produced by the optimized geometries were studied as a function of the number of wires, for the longitudinal and transverse gradient coils. A prototype of the gradient set was made to test the proposed design method. The resulting experimental values of coil efficiency, inductance, field linearity, and shielding performance exhibit good agreement between theory and experiment.  相似文献   

11.
A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from −5 °C to 45 °C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties.  相似文献   

12.
The task of designing the geometry of a set of current-carrying coils that produce the magnetic field required to confine a given plasma equilibrium in stellarators is expressed as a minimization principle, namely that the coils minimize a suitably defined error expressed as a surface integral, which is recognized as the quadratic-flux. A penalty on the coil length is included to avoid pathological solutions. A simple expression for how the quadratic-flux and coil length vary as the coil geometry varies is derived, and an expression describing how this varies with variations in the surface geometry is derived. These expressions allow efficient coil-design algorithms to be implemented, and also enable efficient algorithms for varying the shape of the plasma surface in order to simplify the coil geometry, and a numerical illustration of this is given.  相似文献   

13.
The use of flat RF coils allows considerable gains in the sensitivity of static field gradient (SFG) nuclear magnetic resonance (NMR) experiments. In this article, this effect is studied theoretically as well as experimentally. Additionally, the flat coil geometry has been studied theoretically depending on magnetic field gradient, pulse sequence and amplifier power. Moreover, detecting the signal directly from the free induction decay (FID) turned out to be quite attractive for STRAFI-like microimaging experiments, especially when using flat coils. In addition to wound rectangular flat coils also spiral flat coils have been developed which can be manufactured by photolithography from printed circuit boards.  相似文献   

14.
基于小型射频线圈的核磁共振检测探头在波谱分析和成像研究中具有广泛的应用,如化学位移波谱分析、磁共振成像和勘探测井等技术领域。但是,由于外加静磁场作用下,自旋体系发生塞曼能级分裂后,高低能态之间的核自旋数量之差很小,普遍存在检测信噪比很低的问题,而且初级磁共振接收信号的质量受所用探头线圈电气参数的影响较大。研究结果表明,在特定的被测样品和接收线圈占空比以及静磁场等条件不变的情况下,检测信噪比与单位电流产生的射频磁场成正比,而与线圈高频电阻的平方根成反比。在永磁0.39Tesla主磁场条件下,研究了趋肤效应影响下小型螺线管线圈几何参数的优化设计方法。理论仿真和实际的测量结果表明,几何参数为线径0.5 mm、直径5.5 mm的10匝微螺线管线圈,在16.9 MHz谐振频率上,相对信噪比取得一个极大值点,对应的Q值约为199.8,与阻抗分析仪测得结果有较好的吻合,验证了该核磁共振检测线圈设计新方法是合理的。本文提出的基于线圈电磁特性的高信噪比检测探头设计方法,可推广到目前的质子密度成像、岩心弛豫谱分析等应用中。  相似文献   

15.
A surface coil for MRI was designed and built based on the principles of the petal resonator proposed by Mansfield [J Phys D Appl Phys 21 (1988) 1643]. This resonator coil design was named the petal resonator surface (PERES) coil and is composed of an eight-petal coil array and a central circular coil. A minimum separation of three times the petal coil radius is necessary to significantly decrease the mutual inductance. An analytical function for the PERES Signal-to-noise ratio (SNR) is obtained based on the quasistatic method. Theoretical plots of SNR enhancement yielded 26% and 35% more SNR over the circular coil and phased-array coils. Imaging experiments were first performed using a spectroscopy phantom on a 1.5-T commercial imager. Subsequently, brain images of healthy volunteers were obtained. Clinical MR imager compatibility allows this resonator coil to be used with conventional pulse sequences and imaging protocols. This coil design offers a new alternative to existing surface coils because it significantly increases the SNR.  相似文献   

16.
A topology optimization method based on the solid isotropic material with penalization interpolation scheme is utilized for designing gradient coils for use in magnetic resonance microscopy. Unlike the popular stream function method, the proposed method has design variables that are the distribution of conductive material. A voltage-driven transverse gradient coil is proposed to be used as micro-scale magnetic resonance imaging(MRI) gradient coils, thus avoiding introducing a coil-winding pattern and simplifying the coil configuration. The proposed method avoids post-processing errors that occur when the continuous current density is approximated by discrete wires in the stream function approach. The feasibility and accuracy of the method are verified through designing the z-gradient and y-gradient coils on a cylindrical surface.Numerical design results show that the proposed method can provide a new coil layout in a compact design space.  相似文献   

17.
A high-frequency RF volume coil based on the use of microstrip transmission line (MTL) has been developed for in vivo 1H MR applications on the human head at 4T. This coil is characterized by major advantages: (i) completely distributed coil circuit, (ii) high-quality factor (Q), (iii) simple coil structure, and (iv) better sensitivity and less signal-intensity variation in the MR image of the human head compared with an RF shielded birdcage coil of similar coil size. The proposed MTL volume coil does not require additional RF shielding for preventing Q degradation from radiation losses due to the unique MTL structure; thus, it provides a maximal useable space inside the volume coil when compared with most volume coils available at high fields with the same overall coil size. The intrinsic B(1) distribution of the MTL volume coil effectively compensates for the dielectric resonance effect at 4T and improves the signal homogeneity in human head MR images in the transaxial planes. The results of this study demonstrate that the MTL volume coil design provides an efficient and simple solution to RF volume coil design for human MR studies at high fields.  相似文献   

18.
《Magnetic resonance imaging》1995,13(7):1003-1012
The design of a radiofrequency coil of U-shaped geometry, specifically intended to image individual knuckle joints of the hand, has been investigated. The coil geometry is that of a “split and opened” birdcage coll. The optimum leg positions for such a U-shaped coil have been theoretically predicted using a novel technique that considers both the signal-to-noise ratio and the homogeneity of the field-of-view. Two particular coils of this type have been constructed, each optimum for a different size of image space and assuming a different source of image noise (sampledominated or coil-dominated). The experimentally determined radiofrequency fields produced by the coils correspond well to theory. Either coil can be used to obtain good-quality, high-resolution (130 μm × 130 μm in-plane) images in vivo of the first, second, or fifth metacarpophalangeal joints of the hand, sites of particular interest in the study of arthritis.  相似文献   

19.
A new analytical approach is used in the design of disc-like gradient coils suitable for magnet geometries with main field direction perpendicular to the surface of the disc. An inverse procedure is used to optimize the coil's characteristics, subject to the restrictions imposed by the desired field behavior over a certain set of constraint points inside a predetermined imaging volume. Excellent agreement between the expected values of the gradient magnetic field and the numerical values generated by applying the Biot-Savart law to a discrete current pattern of the perspective disc coil was found. A Finite Element Analysis package was used to predict the fringe gradient field levels for a non-shielded axial disc coil and for a self-shielded transverse disc coil in the vicinity of the magnet poles. The numerical results indicate that for the self-shielded design the gradient fringe field is 1000 times smaller than the corresponding fringe field for the non-shielded disc case. Also no significant spatial dependence was noticed for the shielded coil's fringe field.  相似文献   

20.
Radio-frequency receiver phased-array coils in magnetic resonance imaging systems are used to pick up the signals emitted by the nuclei with high signal-to-noise ratio and a large region of sensitivity. Since the quality of obtained images strongly depends upon the correct choice of the coil geometry and position, array coils have to be designed by minimizing the mutual interaction among nearby coil elements and this is generally achieved by overlapping such adjacent elements. In this paper, we describe the use of a numerical solver based on finite-difference time-domain method to determine the optimal overlap distance, which guarantees the maximum decoupling level between the coil loops, for array coils constituted by various geometry elements. A novel array coil was designed, constituted by a couple of elliptical geometry elements in “folding” version around the animals’ spine curvature, for small animals’ imaging applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号