首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple and rapid method has been developed and validated for the quantitation of vincristine in human plasma by liquid chromatography/tandem mass spectrometry (LC/MS/MS) with atmospheric pressure chemical ionization using on-line solid-phase extraction. The method uses vinblastine as internal standard and the sample preparation is limited just to a plasma protein precipitation step. Further sample clean-up is carried out on-line through a perfusion column preceding an analytical phenyl LC column, the latter directly connected to the mass spectrometer. Quantitation is performed in multiple reaction monitoring mode using the transitions of m/z 825.3 --> 765.3 and 811.3 --> 751.3 for vincristine and vinblastine respectively. The assay was linear (r2 > or =0.99) in a concentration range from 0.1 to 500 ng/mL. Carry-over, measured on the experimental set-up, was less than 0.04%. Recovery for vincristine and the internal standard was within 90-95%. The intra-day and inter-day assay precision ranged from 1.2% to 6.8% RSD while mean percentage deviation from nominal value ranged from 0.01% to 6.1%. The proposed assay was found suitable for pharmacokinetics investigations and clinical therapeutic drug monitoring especially in pediatric cancer patients.  相似文献   

2.
A sensitive and selective high-performance analytical method based on liquid chromatography with tandem mass spectrometric detection (LC/MS/MS) was developed for the quantification of glufosfamide in rat plasma. Zidovudine was employed as internal standard. Glufosfamide was determined after methanol-mediated plasma protein precipitation using LC/MS/MS with an electrospray ionization interface in negative ion mode. Two sets of standard curves were developed, from 0.005 to 1.0 microg/mL and from 1.0 to 50.0 microg/mL. The assay was accurate (% deviations from nominal concentrations < 5%), precise and reproducible (intra- and inter-day coefficients of variation < 10%). Glufosfamide in rat plasma was stable over three freeze/thaw cycles, and at ambient temperatures, for at least 2 h. The validated method was successfully applied to the determination of glufosfamide plasma concentrations in rats for 24 h following an intravenous administration of 25 mg/kg.  相似文献   

3.
A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, has been developed for the determination of the analgesic fentanyl in human plasma. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction (SPE) was carried out using a 96-channel programmable liquid-handling workstation using a mixed-mode sorbent. The extracted samples were then dried down, reconstituted and injected onto a silica column using an aqueous/organic mobile phase with tandem mass spectrometric detection. The method has been validated over the concentration range 0.05-100 ng/mL fentanyl in human plasma, based on a 0.25-mL sample size. The assay is sensitive, specific and robust. More than 2000 samples have been analyzed using this method. The automation of the sample preparation steps not only increased the analysis throughput, but also facilitated the transfer of the method between different bioanalytical laboratories of the same organization.  相似文献   

4.
The effects of flow rate and column length on analyte response (peak area and height), total cycle time, column backpressure, and elution volume are presented. Rapid chromatographic separations and tandem mass spectrometric (MS/MS) detection are applied to the supernatant of protein-precipitated plasma standards containing four compounds from a drug discovery screen. The plasma samples were injected onto three C-18 columns (2 x 10,2.1 x 30 and 2.1 x 50 mm) at flow rates of 0.25, 0.50, 1.00 and 1.50 mL/min. The plasma samples were detected using a Sciex API 3000 tandem mass spectrometer operated in the Turbo Ionspray mode. A post-column split was used to maintain a flow rate of 0.25 mL/min into the mass spectrometer source to avoid differences in nebulization efficiency. The data show that diluted protein-precipitated plasma supernatants show average matrix effects (i.e. suppression) of 60.0% (2 x 10 mm), 89.3% (2 x 30 mm), and 76.7% (2 x 50 mm) of expected response at 10 ng/mL. Average matrix effects of 70.2% (2 x 10 mm), 88.9% (2 x 30 mm), and 81.2% (2 x 50 mm) of expected response at 1000 ng/mL plasma. The data also show if peak widths remain relatively constant, analytes are less sensitive as flow rates are increased. These data are consistent with the concentration-dependent relationship of ionspray in the range of flow rates studied. The data show that, while analyte response decreased proportionately to increases in flow rate, the analysis cycle times did not decrease proportionately.  相似文献   

5.
Two on-line configurations using multiple 6- and 10-port valves were investigated for high-flow on-line extraction of a basic drug in rat plasma and human urine using a reversed-phase and a cation-exchange SPE sorbent. The first configuration studied was a single reversed-phase extraction cartridge (2.1 x 20 mm, 25 microm) using an optimized washing protocol. The results showed that up to 1.5 mL of sample (urine or plasma diluted 1:1) can be injected with limits of quantification (LOQs) as low as 100 pg/mL. The second configuration studied was the combination of a cation exchanger and a reversed-phase cartridge using at-column dilution. The results showed better LOQs than those obtained with the single cartridge at 10 pg/mL with the same injection volume. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration curves gave an average of 5% relative standard deviation (RSD).  相似文献   

6.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

7.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been coupled to in vivo microdialysis for on-line monitoring of melatonin in a freely moving rat for a period of 15 hours. A microdialysis probe was surgically implanted into the jugular vein of the rat, and deionized water was used as the perfusion medium at a flow rate of 1.0 microL/min. Microdialysis samples were collected in an on-line injector with sample injection every 30 minutes. Melatonin was dosed by intraperitoneal (i.p.) injection and then monitored by microdialysis/LC/MS/MS. The whole experiment, including the microdialysis sampling and sample injection into the LC/MS system, was fully automated. Metabolites of melatonin were identified off-line by LC/MSn experiments. Two metabolites were identified as 6-hydroxymelatonin and cyclic 2-hydroxymelatonin, consistent with ones found previously in the literature.  相似文献   

8.
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 microL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 microL injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-microm particles (4.6 mmx50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4-->297 (4-oxo-retinoic acids), 301.2-->205 (retinoic acids), 305.0-->209 (IS) and 269.2-->93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples.  相似文献   

10.
A novel procedure for the determination of nine selected fungicides (metalaxyl-M, azoxystrobin, myclobutanil, flusilazole, penconazole, tebuconazole, propiconazole, diniconazole and difenoconazole) in wine samples is presented. Sample enrichment and purification is simultaneously performed using mixed-mode, anion exchange and reversed-phase, OASIS MAX solid-phase extraction (SPE) cartridges. Analytes were determined by liquid chromatography coupled to tandem mass spectrometry using atmospheric pressure electrospray ionization (LC-ESI-MS/MS). Parameters affecting the chromatographic determination and the extraction-purification processes were thoroughly investigated. Under optimized conditions, 10 mL of wine were firstly diluted 1:1 with ultrapure water and then passed through the mixed-mode SPE cartridge at a flow of ca. 5 mLmin(-1). After a washing step with 5 mL of an aqueous NH(4)OH solution (5%, w:v), analytes were recovered with just 1 mL of methanol and injected in the LC-MS/MS system without any additional purification. The selective extraction process avoided significant changes in the ionization efficiency for red and white wine extracts in comparison with pure standards in methanol. Performance of the method was good in terms of precision (RSDs<11%) and accuracy (absolute recoveries>72%, determined against pure standards in methanol) reporting method LOQs in the range of 0.01-0.79 ngmL(-1) for target compounds, which are far below the EU maxima residue levels (MRLs) for fungicides in vinification grapes and wine. Several commercial wines from different geographic areas in Spain were analyzed. In most samples, metalaxyl-M and azoxystrobin were found at concentrations up to several ngmL(-1).  相似文献   

11.
A novel, sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry) method with on-line extraction and clean-up for the screening and confirmation of residues of tetracyclines in kidney has been developed. After liquid extraction of homogenised kidney with McIlvain buffer, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization followed by multiple reaction monitoring. For each tetracycline the collisional decomposition of the protonated molecule to a unique, abundant fragment ion was monitored. The method has been validated for tetracycline, oxytetracycline, chlortetracycline and doxycycline. Calibration curves resulting from spiked blank kidney samples at the 100-1200 microgram/kg level showed good linear correlation. At the level of 600 microgram/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 7%. The limits of detection (LODs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 18, 23, 24 and 21 microgram/kg, respectively. The limits of quantification (LOQs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 36, 46, 47 and 42 microgram/kg, respectively. The recoveries ranged from 71 to 91%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of tetracyclines in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

12.
A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min.  相似文献   

13.
For biological monitoring of hospital personnel occupationally exposed to antineoplastic agents, highly sensitive and specific methods are required. In order to detect trace MTX urinary concentrations, a precise and accurate high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) procedure, incorporating solid phase extraction, has been developed. Urine samples were purified by solid phase extraction (SPE) on octadecyl bonded, endcapped silica SPE columns. After eluting with methanol, the solvent was evaporated obtaining a 25-fold concentration of the analyte. This procedure was validated by using 7-OHMTX as internal standard. Calibration curves had correlation coefficients always higher than 0.999, and the limit of detection was assessed at 0.2 microg L(-1). High specificity of the HPLC-MS/MS technique assures that no interfering substances are detected rather than the analyte of interest.  相似文献   

14.
With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1, 3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs.  相似文献   

15.
A column-switching system, composed of supercritical fluid extraction (SFE) and reverse phase liquid chromatography/mass spectrometry (RPLC/MS) was constructed for on-line extraction and reverse-phase separation of capsaicinoids in capsicum fruits.  相似文献   

16.
Acetaminophen (APAP) is a widely used analgesic and antipyretic drug. It is mainly metabolized by phase 1 and 2 reactions in the liver, and thus it could be involved in many drug–drug interactions. Therefore, the study of APAP metabolism is important in toxicological and pharmacokinetic studies. The objective of this study was to develop a rapid and sensitive method for the determination of APAP and its six metabolites in rat plasma for the pharmacokinetic studies. APAP and its metabolites were separated through a Capcell Pak MGII C18 column and quantitated with a 16 min run in a triple‐quadruple mass spectrometer. The mobile phases were composed of 0.1% formic acid in either 95% water or 95% acetonitrile and analysis was performed twice in positive and negative modes. Validations such as accuracy, precision, recovery, matrix effect and stability were found to be within acceptance criteria of validation guidelines, indicating that the assay was applicable to the determination of the plasma concentrations of drug and its six metabolites. In conclusion, we developed an LC‐MS/MS method for the quantitative analysis of APAP and its six metabolites in rat plasma, and this method appears to be useful for pharmacokinetic/toxicokinetic studies of APAP and its metabolites in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A simple, automated and rapid method has been developed for the determination of a novel antiviral peptide sifuvirtide in monkey plasma. Raw plasma samples were directly loaded onto an on-line solid-phase extraction (SPE) column, which removes the time-consuming and laborious sample pretreatment. Following a timed valve-switching event, the analyte was eluted on-line to a reversed-phase high-performance liquid chromatography (RP-HPLC) column and subsequently introduced into a linear ion trap mass spectrometer, LTQ-MS, via an electrospray ionization (ESI) interface. The multiply charged peptides were specified and quantitatively analyzed using selective reaction monitoring (SRM). A highly pure four iodine-sifuvirtide was synthesized using an optimized iodogen method and proved to be a suitable internal standard (IS). A single analysis run takes about 18 min. Validation of the method demonstrated that the linear calibration curves covered the range of 4.88-5000 ng/mL, and the correlation coefficients were above 0.9923. The limit of detection (LOD) with the signal-to-noise (S/N) ratio higher than 12 was calculated as 1.22 ng/mL. The intra- and inter-batch precisions were less than 12.7% and 9.1%, and the mean accuracy ranged from -5.2% to 3.6%, respectively. Any carry-over effect from the system was negligible. In a pharmacokinetic (PK) study of sifuvirtide after a single intravenous or subcutaneous dose in monkeys, the on-line SPE-LC/MS/MS system was successfully utilized to determine hundreds of samples with only one extraction column, which indicated the feasibility and the reliability of this method for application in preclinical and clinical PK studies of peptide drugs.  相似文献   

18.
19.
A two-dimensional capillary array liquid chromatography system coupled with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) was developed for high-throughput comprehensive proteomic analysis, in which one strong cation-exchange (SCX) capillary chromatographic column was used as the first separation dimension and 10 parallel reversed-phase liquid chromatographic (RPLC) capillary columns were used as the second separation dimension. A novel multi-channel interface was designed and fabricated for on-line coupling of the SCX to RPLC column array system. Besides the high resolution based on the combination of SCX and RPLC separation, the developed new system provided the most rapid two-dimensional liquid chromatography (2D-LC) separation. Ten three-way micro-splitter valves used as stop-and-flow switches in transferring SCX fractions onto RPLC columns. In addition, the three-way valves also acted as mixing chambers of RPLC effluent with matrix. The system enables on-line mixing of the LC array effluents with matrix solution during the elution and directly depositing the analyte/matrix mixtures on MALDI plates from the tenplexed channels in parallel through an array of capillary tips. With the novel system, thousands of peptides were well separated and deposited on MALDI plates only in 150min for a complex proteome sample. Compared with common 2D-LC system, the parallel 2D-LC system showed about 10-times faster analytical procedure. In combination with a high throughput tandem time of flight mass spectrometry, the system was proven to be very effective for proteome analysis by analyzing a complicated sample, soluble proteins extracted from a liver cancer tissue, in which over 1202 proteins were identified.  相似文献   

20.
Hemimicelles of tetradecanoate chemisorbed onto magnetic nanoparticles (MNPs) are here proposed as a sorbent for the single-step extraction and cleanup of bisphenol A (BPA) in soft drinks. The purpose of this work was to develop a simple, rapid and low-cost sample treatment suitable to assess the human exposure to BPA from this type of high consumption food. The nanoparticles were easily coated by mixing commercially available magnetite of 20–30 nm mean particle diameter with tetradecanoate at 85 °C for 30 min. The extraction/cleanup procedure involved stirring the samples (3 mL) with 200 mg of tetradecanoate-coated MNPs for 20 min, isolating the sorbent with a Nd–Fe–B magnet and eluting BPA with methanol. The extraction efficiency was not influenced by salt concentrations up to 1 M and pH values over the range 4–9. No cleanup of the extracts was needed, and the method proved matrix-independent. The extracts were analyzed by liquid chromatography, electrospray ionization tandem mass spectrometry. Quantitation was performed by internal standard calibration using BPA-13C12. The limit of quantitation obtained for the method, 0.03 ng mL−1, was below the usual range of concentrations reported for BPA in soft drinks (0.1–3.4 ng mL−1). The proposed method was successfully applied to the determination of BPA in different samples acquired from various supermarkets in southern Spain; the concentrations found ranged from 0.066 to 1.08 ng mL−1. Recoveries from samples spiked with 0.33 ng mL−1 of BPA ranged from 91% to 105% with relative standard deviations from 3% to 8%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号