首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A microchip pressure-driven liquid chromatography (LC) with a packed column and an electrochemical flow cell has been developed by using polystyrene (PS) and poly(dimethylsiloxane) (PDMS). The cylindrical separation column with packed octadecyl silica particles was fabricated in the PS substrate. The three electrode system (working, reference, and counter electrode) for amperometric detection was fabricated onto the PS substrate, using the Au deposition, photolithography, and chemical etching. The detector flow cell was formed by sealing the electrode system with a PDMS chip containing a channel. In this flow cell, the effect of working electrode width (in the direction of flow) on chromatographic parameters, such as peak width and peak resolution were studied in electrode width ranging 50-5,000 microm. The effect of electrode width on sensitivity (current intensity, current density, and S/N ratio) was also examined. The sensitivity was discussed by simulating the concentration profile generated around the working electrode. The effects of the column packing size and the column size on the separation efficiency were examined. In this study, a good separation of three catechins was successfully achieved and the detection limits for (+)-catechin, epicatechin, and epigallocatechin gallate were 350, 450, and 160 nM, respectively.  相似文献   

2.
Johann R  Renaud P 《Electrophoresis》2004,25(21-22):3720-3729
Selective transport and sorting of particles in microfluidic devices by electroosmosis is complicated due to superposition of uncontrolled hydrodynamic pressure contributions on the electroosmotic force. In this paper, we present a microfluidic concept for the reliable and simple separation and sorting of particles in a microchip by electroosmosis combined with pressure-driven flow. The presented device allows fluid quantities to be switched and particles to be sorted within a channel manifold using only a single power supply with fixed voltage and an electric switch. Consequently, chip operation and fluid switching procedure are greatly simplified compared to a situation, in which several independent power sources are used for flow balancing, as is the common procedure. With the triple-T channel design presented, backpressure flow disturbing the electrokinetic fluid and particle separation process is eliminated by introducing controlled opposed hydrodynamic flow of buffer from side channels. This pressure-driven flow is generated on-chip by setting up differences in the reservoir pressures in a defined manner. A detailed flow analysis based on the equivalence of fluid flow and electric current is performed and the conditions for reliable chip function are worked out.  相似文献   

3.
Qu P  Zhang L  Sheng J  Lei J  Ju H 《Electrophoresis》2011,32(12):1522-1529
A microchip integrated with a monolithic imprinted capillary has been manufactured for performing the chip-based capillary electrochromatographic enantioseparation. The microporous monolith anchored on the inner wall of the microchannel was prepared by in situ chemical copolymerization, and characterized with scanning electron microscopy, IR spectroscopy, and solid-state UV-vis spectroscopy. The monolithic network with high porosity gave a large surface area, good permeability, low mass-transfer resistance, and thus high separation efficiency. A portable microchip was conveniently constructed by integrating an imprinted capillary with 5-cm length as the separation channel and a carbon fiber microdisk working electrode for amperometric detection. Using L-tyrosine (L-Tyr) as the template molecule, Tyr enantiomers could be baseline separated within 55 s under the optimized preparation and separation conditions. The linear ranges for online amperometric detection of both Tyr enantiomers were from 20 to 2400 μM. The microporous monolithic chip strategy exhibited excellent separation efficiency and promising analytical application in enantioseparation. It opens an avenue for high-throughput screening of chiral compounds.  相似文献   

4.
A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.  相似文献   

5.
微流控芯片实验室   总被引:3,自引:0,他引:3  
林炳承  秦建华 《色谱》2005,23(5):456-463
以作者所在课题组近年来的研究工作为基础,就芯片实验室平台建设及相应的以系统生物学为最终目标的功能化研究作一说明,对在分子和细胞层面,甚至是单分子、单细胞水平上实现以规模集成为特征的临床诊断和药物筛选的努力予以特别的关注。  相似文献   

6.
In this article, we report the design of a microchip based hydraulic pump that employs a sodium silicate derived sol–gel structure for generating pressure-driven flow within a microfluidic network. The reported sol–gel structure was fabricated in a chosen location of our device by selectively retaining sodium silicate solution within a sub-micrometer deep segment via capillary forces, and then providing the precursor material appropriate thermal treatment. It was shown that while the molecular weight cut-off for these membranes is at least an order of magnitude smaller than their photo-polymerized counterparts, their electrical conductance is significant. Moreover, unlike their polymeric counterparts these structures were found to be capable of blocking electroosmotic flow, thereby generating a pressure-gradient around their interface with an open microchannel upon application of an electric field across the microchannel–membrane junction. In this work, a fraction of the resulting hydrodynamic flow was successfully guided to an electric field-free analysis channel to implement a pressure-driven assay. Our experiments show that the pressure-driven velocity produced in the analysis channel of our device varied linearly with the voltage applied across the sol–gel membrane and was nearly independent of the cross-sectional dimensions of the membrane and the microfluidic channels. With our current design pressure-driven velocities up to 1.7 mm/s were generated for an applied voltage of 2 kV, which easily covers the range of flow speeds that can minimize the plate height in most microfluidic separations. Finally, the functionality of our device was demonstrated by implementing a reverse phase chromatographic separation in the analysis channel of our device using the pressure-driven flow generated on-chip.  相似文献   

7.
An integrated microchip for monitoring carbamate pesticides in environmental water using continuous flow chemical processes is under development, i. e., the integration of hydrolysis, azo-derivatization, liquid-liquid extraction, electrophoretic separation, and quantification. The separation of the derivatives of four carbamate pesticides (carbaryl, carbofuran, propoxur, and bendiocarb) extracted in the continuous flow of a 1-butanol phase was studied in a silica microchip using micellar EKC. A baseline separation of four pesticide derivatives was achieved on a silica chip using hydrodynamic injection with electroosmotic gating. Detection using a thermal lens microscope showed good linearity in the concentration range of 10(-6 )-10(-5 )M with an LOD of 5 x 10(-7) M, which is superior to that of conventional CE with UV absorption detection at a level of 10(-4) M.  相似文献   

8.
Wistuba D  Schurig V 《Electrophoresis》2000,21(15):3152-3159
A chiral monolithic stationary phase was prepared by packing a capillary with bare porous silica and sintering the silica bed at high temperature. The resulting silica monolith was polymer-coated with Chirasil-Dex, a permethylated beta-cyclodextrin covalently linked via an octamethylene spacer to dimethylpolysiloxane. Subsequently, Chirasil-Dex was thermally immobilized on the silica support and a chiral monolith of very high stability (30 kV, more than 400 bar pressure) was obtained. The enantiomer separation of various chiral compounds by monolithic (rod) capillary electrochromatography (rod-CEC) was feasible. This method was compared with capillary liquid chromatography (LC) in a single-column mode using unified equipment. About two to three times higher efficiency was found in the rod-CEC mode as compared to rod-LC. The influence of pressure-driven flow support on efficiency, resolution, elution time and baseline stability was investigated. The amount and nature of organic modifier strongly influences efficiency and resolution.  相似文献   

9.
Microfluidic device for capillary electrochromatography-mass spectrometry   总被引:2,自引:0,他引:2  
Lazar IM  Li L  Yang Y  Karger BL 《Electrophoresis》2003,24(21):3655-3662
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.  相似文献   

10.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

11.
Analyses of amino acids and peptides were performed using a quartz microchip and an interface for microchip electrophoresis-electrospray ionization mass spectrometry (MCE-ESI-MS). In MCE-ESI-MS, negative pressure caused by ESI increased band broadening and deteriorated separation. We tried to suppress the negative pressure and improve separation using a microchip with a long separation channel. Separations of peptide standards were compared using two microchips with long separation channel (58.9 mm) and short one (22.9 mm). Theoretical plate numbers and resolution were improved significantly using the former. The theoretical plate numbers of [Val4]angiotensin was 8600 using the former and 1700 using the latter. When background electrolytes of low pH were used in an uncoated quartz microchip, electrokinetic injection was difficult because of weak electroosmotic flow. The use of successive multiple ionic polymer layers coating of the microchip channel stabilized electrokinetic injection and permitted analysis of amino acids and peptides even under low pH conditions. Separation of amino acids was successfully performed using formic acid solution (pH 2.5) as background electrolyte.  相似文献   

12.
Vrouwe EX  Luttge R  van den Berg A 《Electrophoresis》2004,25(10-11):1660-1667
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.  相似文献   

13.
在简单综述了微流控芯片发展的基础上,详细讨论了芯片电泳过程数学模型包括电场、流场、浓度分布弯管道传质控制方程的建立及其求解方法,进而讨论了借助计算机模拟计算辅助芯片电泳系统网络管道设计的研究进展,重点包括进样管道及分离管道设计。  相似文献   

14.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

15.
Robust monolithic silica-based on-chip electro-osmotic micro-pump   总被引:1,自引:0,他引:1  
Nie FQ  Macka M  Barron L  Connolly D  Kent N  Paull B 《The Analyst》2007,132(5):417-424
A robust, compact, on-chip, electro-osmotic micro-pump (EOP) for micro-flow analysis, based on parallel, encased, 10 x 0.1 mm I.D. monolithic silica capillary columns has been developed. A 15 x 40 x 2 mm poly(methyl methacrylate) (PMMA) chip, containing a total of nine parallel EOP systems was fabricated, allowing the use of single, double or triple monolithic columns to produce increased flow as required. The monolithic silica was compatible with both aqueous and organic solvents without swelling or shrinking problems, with the triple column EOP capable of generating flow of up to 0.6 microL min(-1) under zero pressure load and over 0.1 microL min(-1) with an applied pressure of ca. 2.4 bar using an applied voltage of just 2 kV. Current generated at the 2 kV applied voltage for a 2 mM acetate buffer solution (pH 4.5) was under 4 microA, allowing stable, bubble-free flow. The developed triple column EOP was incorporated within a micro-fluidic chip (5.0 x 2.0 x 0.4 cm) integrated with a second single 10 x 0.1 mm column EOP, for combined sample injection and simple on-chip micro-flow analysis.  相似文献   

16.
甲基丙烯酸基质的毛细管电色谱整体柱的制备与应用   总被引:1,自引:0,他引:1  
以甲基丙烯酸(MAA)为功能单体,同时又作电渗流改性剂, 乙二醇二甲基丙烯酸酯(EDMA)为交联剂,甲苯和异辛烷为致孔剂,Irgacure 1800为光引发剂,采用紫外光引发原位聚合反应制备出毛细管电色谱整体柱.对影响电渗流的因素如pH、乙腈含量及离子强度等进行了讨论.使用制备的整体柱在3种模式(加压电色谱、气压驱动和电色谱)下对7种中性物质(硫脲、苯、甲苯、乙苯、萘、联苯和菲)的混合物实现基线分离,同时还可实现酸性物质(邻羟基苯甲酸、苯甲酸、苯乳酸、扁桃酸)和碱性物质(苯胺、甲苯胺、乙酰基苯胺和N-甲基苯胺)的快速分离.  相似文献   

17.
选择了L-精氨酸和L-苯丙氨酸为分离样品体系,根据电泳实验提出样品基本参数,通过模拟计算考察了进样管道宽度和进样时间对进样方差的贡献;根据分离度与分离长度拟合曲线确定电泳芯片的有效分离长度;对化学发光柱后衍生管道施加的夹流电压进行了模拟优化,得出氨基酸体系分离分析的电泳芯片设计方案和操作参数为:进样管道宽度为分离管道宽度的1/2,简单进样充样时间应大于5 s,分离管道有效分离长度为30 mm,衍生夹流比1.0~1.6。根据模拟优化结果提出了电泳芯片设计方案,采用整体浇注法制作带有柱后衍生反应器的PDMS电泳芯片,按照模拟计算提出的电压操作参数实现了精氨酸和苯丙氨酸样品体系的准确进样、芯片电泳分离和柱后衍生化学发光检测。电泳过程模拟结果和实验结果相结合,考察了柱后衍生对样品谱带展宽的影响,简单进样过程样品泄露引起的谱峰拖尾现象,并讨论了夹流进样法对减小进样方差和抑制样品泄露的贡献。  相似文献   

18.
Enantioseparations in nonaqueous capillary electrochromatography (CEC) are reported in this study for the first time, using wide-pore aminopropyl silica gel coated with helically chiral poly(diphenyl-2-pyridylmethyl methacrylate) (PDPM) as chiral stationary phase (CSP). The anodic electroosmotic flow (EOF) in a methanolic solution of ammonium acetate was used for the migration of neutral analytes through the packed bed in the capillaries. Four different techniques, high-performance liquid chromatography (HPLC) in common-size columns, capillary HPLC, pressure-assisted CEC and CEC were compared from the viewpoint of separation parameters. The latter three were performed with the same experimental setup, varying the relative contribution of the pressure-driven and the electrically driven flow to the overall mobility of the analyte. Capillary HPLC offers clear advantages compared to enantioseparations in common-size columns. However, for a given particle size of the packing material, CEC was not obviously advantageous compared to pressure-driven separations.  相似文献   

19.
《Analytical letters》2012,45(8):1468-1476
Abstract

Monolithic silica fabricated in microchannel by adding Methyltrimethoxysilane in starting composition of the sol used for preconcentration of volatile organic compounds was investigated in this study. Fabrication of monolithic silica in microchannel is difficult because of the shrinkage of monolithic silica. By adding Methyltrimethoxysilane in starting composition, the monolithic silica was successfully fabricated in a microchannel of a microchip. The developed microchip was used for preconcentration of VOCs followed by thermal desorption and GC/MS detection. It provides a good preconcentration method for developing an on-site VOCs monitoring micro total analysis system.  相似文献   

20.
An ionspray microchip is introduced. The chip is based on the earlier presented nebulizer microchip that consists of glass and silicon plates bonded together. A liquid inlet channel, nebulizer gas inlet, and nozzle are etched on the silicon plate and a platinum heater is integrated on the glass plate. The nebulizer microchip has been previously used in atmospheric pressure chemical ionization, atmospheric pressure photoionization, sonic spray ionization, and thermospray ionization modes. In this work we show that the microchip can be operated also in ionspray mode by introducing high voltage to the silicon plate of the microchip. The effects of operation parameters (voltage, nebulizer gas pressure, sample solution flow rate, solvent composition, and analyte concentration) on the performance of the ion spray microchip were studied. Under optimized conditions the microchip provides efficient ionization of small and large compounds and good quantitative performance. The feasibility of the ion spray microchip in liquid chromatography/mass spectrometry (LC/MS) was demonstrated by the analysis of tryptic peptides of bovine serum albumin. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号