首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
The use of a single prederivatization step in conjunction with high-performance liquid chromatography (h.p.l.c.) is described for the determination of methylmalonic acid (MMA). The method is based on the reaction of MMA and 4-diazobenzenesulfonic acid, which produces a derivative that has a molar absorptivity of about 9 × 103 l mol?1 cm?1 at 353 nm. The derivatization reaction is optimized for various parameters. A reagent concentration of 3.3 mM at a reaction pH of 4.6 and a temperature of 100°C are optimal. The reaction product is separated from the excess of reagent and other interfering components by using a polystyrene-divinylbenzene column and a highly aqueous mobile phase. After a simple clean-up step, it is possible to quantify MMA in urine at about 0.8 mg l?1 with linear response up to 32 mg l?1.  相似文献   

2.
A new HPLC method for the determination of oxidative breakdown products of aminopolyphosphonates is presented. The phosphonate nitrilotrismethylenephosphonic (NTMP) acid undergoes catalytic oxidation by molecular oxygen in the presence of manganese(II). The two diphosphonates iminodimethylenephosphonic acid (IDMP) and formyliminodimethylenephosphonic acid (FIDMP) are formed. The analytical method employs the derivatization of the aldehyde group in FIDMP by 2,4-dinitrophenylhydrazine and of the imine group in IDMP by 9-fluorenyl methylchloroformate. The two derivatives are quantified in separate runs using the same acidic phosphate-acetonitrile eluent with detection at 370 nm for FIDMP and 260 nm for IDMP. The detection limit for FIDMP is 0.01 microM, for IDMP 0.02 microM. The method is suitable for the determination of the breakdown products in wastewater.  相似文献   

3.
A high-performance liquid chromatography (HPLC) method with diode-array detection (DAD) to identify and quantify formaldehyde (FA) in spirits is described. Formaldehyde was quantified with DAD after derivatization with ethyl 3-oxobutanoate and ammonia to yield the diethyl 2,6-dimethyl-1,4-dihydropyridine-3,5-dicarboxylate. The response of the detection system was linear within the range of 0.25-2.00 μg/ml with a correlation coefficient of 0.9998. The average formaldehyde concentration in the samples ranged between 0.27 and 3.01 mg/l. The coefficient of variation was lower than 4.84% and recoveries ranged from 93.4 to 100.4%. Purity of formaldehyde derivative peak was confirmed by spectral data.  相似文献   

4.
In this study the possibility of derivatizing sugars using microwave irradiation was investigated. The amount of reagent, irradiation intensity, and derivatization time were optimized. In the derivatization of sugars with p-nitroaniline the reaction is complete within 5 min at 600 W when the p-nitroaniline-to-sugar and NaBH3CN-to-sugar mole ratios were above 1.4 and 3.1, respectively. A Doehlert design was used to optimize the mobile phase for separation of p-nitroaniline-labeled sugars; and the best separation was obtained by use of 0.01 mol L−1 acetate buffer at pH 4.40 containing 11.0% acetonitrile. Analysis using this method was highly sensitive and analysis time was short. Finally, a food sample was analyzed using the proposed method.  相似文献   

5.
A new, simple and sensitive pre-column fluorescence derivatization high-performance liquid chromatographic method for the determination of the oxidative DNA stress marker, 8-oxo-7,8-dihydro-2'-deoxyguanosine, was developed. Solid-phase extraction using an Oasis HLB cartridge avoided troublesome sample preparation steps, interference from charged species and frequent and essential electrode maintenance in electrochemical procedures. 8-Oxo-7,8-dihydro-2'-deoxyguanosine and other guanine compounds were selectively derivatized with glyoxal reagents (phenylglyoxal, 3,4-methylenedioxyglyoxal, 2-naphtylglyoxal and 6-methoxynaphthylglyoxal) at 40-60 degrees C. Derivatization with 6-methoxynaphthylglyoxal at 40 degrees C for 30 min gave the strongest fluorescence product. The fluorescence derivatives from reaction with 6-methoxynaphthylglyoxal were separated on a Capcell Pak C18 SG 120A column (4.6 mm i.d. x 150 mm, 5 microm) with acetonitrile-5 mM phosphate buffer (pH 6.0; 3:7, v/v) as mobile phase. The detection wavelength of the fluorescence derivative of 8-oxo-7,8-dihydro-2'-deoxyguanosine was lambda(ex) 400 nm and lambda(em) 510 nm. The detection limit of 8-oxo-7,8-dihydro-2'-deoxyguanosine was 1 ng/mL using 50 mL of urine. The calibration graphs were linear up to 30 microg/mL for 8-oxo-7,8-dihydro-2'-deoxyguanosine. The relative standard deviation of 20 ng/mL of 8-oxo-7,8-dihydro-2'-deoxyguanosine was 7.0%. The proposed method was compared with the enzymatic ELISA 8-oxo-7,8-dihydro-2'-deoxyguanosine analysis method (8-OH-dG Check, JaICA, Shizuoka, Japan). The correlation coefficient was 0.79 (n = 20) and y = 0.85x + 5.34. The proposed method was applied to the monitoring of 8-oxo-7,8-dihydro-2'-deoxyguanosine in urine from male heavy smokers.  相似文献   

6.
A styrene/divinylbenzene polymer column and an amino column are compared for the non-aqueous separation of primary, secondary and tertiary alkylamines. Post-column derivatization with o-phthalaldehyde/2-mercaptoethanol is selective for primary amines and derivatization with 7-chloro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) is selective for secondary amines after on-line masking of primary amines. This procedure can tolerate 0.4 M butylamine. The limit of detection is 18.5 mM for dioctylamine (with NBD-Cl) and 0.18 mM for decylamine and tetraethylenepentamine (with o-phthalaldehyde/2-mercaptoethanol).  相似文献   

7.
A simple, selective, and sensitive liquid chromatographic method with ultraviolet detection was developed for the analysis of penicillin G in bovine plasma. The assay utilizes a simple extraction of penicillin G from plasma (with a known amount of penicillin V added as internal standard) with water, dilute sulphuric acid and sodium tungstate solutions, followed by concentration on a conditioned C18 solid-phase extraction column. After elution with 500 microliters of elution solution, the penicillins are derivatized with 500 microliters of 1,2,4-triazole-mercuric chloride solution at 65 degrees C for 30 min. The penicillin-mercury mercaptide complexes are separated by reversed-phase liquid chromatography on a C18 column. The method, which has a detection limit of 5 ng/ml (ppb) in bovine plasma, was used to quantitatively measure the concentrations of penicillin G in plasma of steers at a series of intervals after the intramuscular administration of a commercial formulation of procaine penicillin G.  相似文献   

8.
New fluorescence derivatization techniques are introduced for the quantitative determination of arginine- or tyrosine-containing peptides by high-performance liquid chromatography with fluorescence detection. The methodology offers enhancement of both sensitivity and specificity. It is thus suitable for trace (0.1–10 pmol) analysis of the bioactive peptides such as angiotensins and enkephalins.  相似文献   

9.
Summary On-column endcapping and derivatization or regeneration of C8 and C18 reversed-phase HPLC columns with newly introduced reagents were studied. These treatments can increase column life expectancy by restoring retention times and original chromatographic characteristics of the columns. This is illustrated by examples. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

10.
In this paper, we describe a highly specific, sensitive and reliable method for total metallothionein (MT) quantification by RP-HPLC coupled to fluorescence detection following reaction with monobromobimane of thiols from metal-depleted MT after heat-denaturation of extracts in the presence of sodium dodecyl sulphate (SDS). SDS-polyacrylamide gel electrophoresis (SDS-PAGE) confirmed the identity of the peak resolved (t(R)=16.44) with MT: a highly fluorescent protein of approximately 8.3 kDa, in agreement with the high thiol content and low MT size. Other heat-resistant and Cys-containing proteins of 35 kDa were efficiently separated. The new method was successfully used to quantify MT content in digestive gland of clams from southern Spanish coastal sites with different metal levels, and is proposed as a tool for using MTs as biomarker in monitoring programmes.  相似文献   

11.
A high-performance liquid chromatographic procedure with a postcolumn fluorescence derivatization is developed for the analysis of oleandrin in bovine blood. Oleandrin is separated by an octadecylsilane-bonded column with a mobile phase containing dehydroascorbic acid. The effluent of the column is mixed with concentrated hydrochloric acid and passed through poly(tetrafluoroethylene) tubing maintained at 70 degrees C. The resultant fluorophores are detected at 465 nm with excitation at 348 nm. Simple solid-phase extraction using Sep-Pak tC2 is effective for sample purification. We found the minimal detectable quantity of oleandrin in plasma to be 1.5 ng/mL at a signal-to-noise ratio of 3:1.  相似文献   

12.
A sensitive determination method for melatonin was developed. Melatonin was derivatized under alkaline conditions in the presence of hydrogen peroxide. The resultant fluorophore was excited at 247 nm and the emission wavelength was 384 nm. The Stokes shift was 137 nm, which was longer than that of melatonin itself (lambda ex 280 nm, lambda em 330 nm). The melatonin derivative was separated by reversed-phase HPLC in about 15 min and the calibration curve was linear from 500 amol to 5 pmol (r > 0.999) with the detection limit of 500 amol (S/N = 5). The sensitivity of this method was about ten times higher than that of previous methods. Both the day-to-day precision and within-day precision were about 5%, and the derivative of melatonin in the aqueous solution was stable for more than 10 days. This method was successfully applied to the determination of melatonin in rat pineal gland.  相似文献   

13.
A high-performance liquid chromatographic method was developed for the determination of citrulline and homocitrulline using a post-column colorimetric reaction with o-phthaladehyde and N-(1-naphthyl)-ethylenediamine. Citrulline and homocitrulline were determined with no interferences from protein amino acids. The results show that the level of citrulline in the plasma of patients with uremia on intermittent hemodialysis is higher than that in healthy human plasma, and that homocitrulline is excreted into the urine of healthy adults.  相似文献   

14.
15.
A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was <3% for all 6 concentration levels. The correlation coefficient for the linearity within the concentration range was determined to be > 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.  相似文献   

16.
Summary The use of diacetyldihydrofluorescein (DADF) for derivatization of dihydroartemisinin (dihydroqinghaosu, DHQHS) is proposed. The reaction between DHQHS and this reagent in the presence of 4-dimethylaminopyridine (DMAP) and N,N′-dicyclohexylcarbodiimide (DCC) was complete in 8 hours at room temperature giving about 80 per cent theoretical yield. The derivative showed intense UV absorption, thus providing a sensitivity of 0.1 nanogram by UV detection after column separation. The influences of the ratio of the reagents, reaction temperature, chromatographic conditions and the extent of detection linearity were investigated. The reaction gave consistent results and chromatographic separation was not affected by an excess of the reagent or side products.  相似文献   

17.
Structures and related enantioselectivities of the respective chiral derivatization reagents (CDRs) for drug enantioseparation by high-performance chromatography based upon pre-column derivatization and diastereomeric formation are reviewed. The elution order of diastereomers caused reaction of some CDRs with enantiomeric amino acids and carboxylic acids. The development of new CDRs available for indirect HPLC methods is also discussed. (c) 2001 John Wiley & Sons, Ltd.  相似文献   

18.
19.
A simple and economical high-performance liquid chromatographic method has been developed for the simultaneous determination of betamethasone and dexamethasone. The method is based on the derivatization of the structural epimers of betamethasone and dexamethasone with a homochiral reagent, N-carbobenzoxy-L-phenylalanine. The derivatives obtained were easily recognized by a non-chiral silica column with n-hexane-dichloromethane-isopropanol (100:100:4, v/v/v) as a mobile phase and a good separation was obtained for quantitation. The method was satisfactorily applied to the determination of betamethasone and dexamethasone in tablets.  相似文献   

20.
A novel method based on solid-phase extraction was studied for the extraction of amitrole (3-amino-1,2,4-triazole), and its residue determination in apples has been developed. The samples were derivatized with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF). The derivatization conditions and the influence of elution composition on the separation were investigated. In pH 9.5 H3BO3–Na2B4O7 media, the reaction of amitrole with CNBF was complete at 60°C after 30 min. The separation of derivatized amitrole was achieved at room temperature within 13 min by gradient elution mode with cetyltrimethylammonium bromide in mobile phase as ion-pair reagent. The method correlation coefficient was 0.9996, in concentrations ranging from 1.66 to 415 mg L−1. The calculated recoveries of the proposed method were from 94.17% to 105.67%, and relative standard deviations were 1.57% to 6.44% in the application to the quantitative determination of amitrole in apples. The detection limit of amitrole was 0.10 mg L−1 with a signal-to-noise ratio of 3. Figure Residue determination of amitrole in apple by ion-pairing high-performance liquid chromatography  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号