共查询到20条相似文献,搜索用时 15 毫秒
1.
This article describes the use of a programmed temperature vaporizer injection system which overcomes many of the classical problems associated with other injection techniques employed in capillary GC. The system can be operated in three distinct modes. 相似文献
2.
S. Boneva 《Chromatographia》1991,31(3-4):171-172
Summary The GC separation of a mixture of three ethanolamines and four ethylene glycols without any preliminary derivatization, on a wide-bore capillary column coated with Carbowax 20M is described. These high-boiling and polar compounds elute giving simmetrical peaks and show good resolution. The analysis is completed in less than 14 minutes. 相似文献
3.
A cold on-column injection system for capillary gas chromatography (GC) applications was constructed. It was based upon a conventional split/splitless capillary GC inlet, which in turn was a modification of a conventional packed GC column inlet. The heart of the laboratory constructed cold on-column inlet design was a disposable pyrex micro-sampling pipet, which functioned as a needle guide for sample injection. The sample was injected through a traditional GC septum. Construction of the injection system is described and applications are illustrated by separations of a variety of complex mixtures. 相似文献
4.
A new type of capillary column for gas chromatography was proposed. A sorbent layer (for example, stationary liquid phase) is supported on the internal capillary surface, and the internal (interstitial) volume is packed with nonporous large particles of a sorbent (particle diameter is 0.1—0.6 of the capillary internal diameter). The external surface of the particles can also be coated with the sorbent layer (for example, stationary liquid phase). The specific separation efficiency (number of separation) on the new type column is by 1.6—2.3 times higher than that of the initial classical capillary column. 相似文献
5.
In this study, application of a fused silica capillary column for analysis of toxic anthraquinones and related compounds found in plants was investigated. 相似文献
6.
7.
8.
9.
10.
11.
D. Labadarios I. M. Moodie J. A. Burger G. S. Shephard 《Journal of separation science》1988,11(3):229-233
A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficients of variation for all amino acids (with the exception of aspartic acid) were better than 11% with recoveries ranging from 81% to 122%. The data are compared with the corresponding results obtained using a packed column and show significant differences (p < 0.005) between values for glycine, serine, isoleucine, proline, methionine, aspartic acid, phenylalanine, and lysine. A similar comparison between results from the wide bore and the fused-silica open tubular (FSOT) column shows better agreement. Adjustment of chromatographic conditions for the wide bore analysis yields results in good agreement with those from FSOT analysis but which still differe significantly from the backed column data. 相似文献
12.
13.
14.
By the use of a wide-bore WCOT capillary column, it was possible to obtain the first on-the-fly GC/FT-IR spectra with a WCOT column. This wide-bore WCOT column gave improved separation, as compared to a SCOT column, and yielded identifiable infrared spectra for a real sample. 相似文献
15.
16.
17.
Pengzhi Li Zemin Xu Xiupei Yang Weiwen Bi Dan Xiao Martin M.F. Choi 《Journal of chromatography. A》2009,1216(15):3343-3348
A method for preparation of a stationary phase-adjustable column with in-column stationary phase-coated fused-silica fiber annular column was successfully developed. The surface of a 0.12 mm o.d. bare optical fiber was first coated with a stationary phase and then inserted into a fused-silica capillary (non-coated or coated) as an annular column for gas chromatographic study. The optical fiber and capillary were coated with polydimethylsiloxane (SE-30) and polyethylene glycol 20M (PEG-20M) as nonpolar and polar stationary phases, respectively. Among the investigated annular and open tubular columns, the PEG-20M-coated fiber-in-PEG-20M-coated capillary annular column showed the highest column efficiency with a minimum plate height of 0.35 mm and an optimum gas velocity of 25 cm/s. When a SE-30/PEG-20M-coated fiber-in-uncoated capillary annular column was applied to separate a 9-component complex mixture, the total analysis time was 5.3 min and the column length was 12 m. By contrast, when a SE-30-coated fiber-in-PEG-20M-coated capillary annular column was used to separate the same 9-component mixture, the analysis time was reduced to 3.5 min and the column length was shortened by half to 6 m. Our results show that the stationary phase-coated fiber-in-stationary phase-coated capillary annular column is a better choice for gas chromatographic separation as it is more efficient and flexible. In addition, the proposed annular column design provides flexibility in using two or even more types of stationary phases to achieve optimal analytical separation. 相似文献
18.
19.
Summary A new PLOT column (CP-LOWOX) designed specifically for the analysis of oxygenated compounds has been used for the gas chromatographic
determination of semi-volatile carbonyl compounds. The separation behavior of the new column was investigated by comparing
it with the widely used non-polar polydimethylsiloxane and polar poly(ethylene glycol) columns. The CP-LOWOX column has unique
selectivity for aldehydes and ketones enabling a selective separation of these analytes from predominating hydrocarbon matrices.
Application of the CP-LOWOX column for the analysis of polar compounds in ambient air is demonstrated. Sampling was performed
by adsorptive enrichment coupled with thermal desorption. The suitability of Tenax TA and a multi-bed adsorbent trap Carbotrap
C and Carbotrap) was tested for the sampling of semivolatile carbonyl compounds.
Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999 相似文献
20.
Summary Reaction products of the pyrolysis of n-dodecylpentane and n-hexylcyclohexane had been separated and identified on a glass capillary column coated with Polydimethylsiloxane OV-1.The identification of the components in the pyrolysis products and of the corresponding hydrogenated samples was performed from structure retention correlations, especially retention index increments (1CH2), homomorphy values (HOV-1) and the temperature coefficients of retention indices (I/T). Hence the presence of homologous 1-alkenes and of monoalkenylcycloalkanes could be confirmed. Based on the addition principle of index increments the determination of the side chain structure of alkenylcycloalkanes (straight chain) and the position of the double bond was ascertained. The calculation of the retention indices of these compounds was performed with high accuracy (deviation <1 index unit). Retention indices of 10 1-alkenes, 11 monoalkenyl-cyclopentanes, 11 monoalkylcyclopentanes, 5 monoalkenylcyclohexanes and 5 monoalkylcyclohexanes were determined on the liquid phase Polydimethylsiloxane OV-1. 相似文献