首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 580 毫秒
1.
中国科学院近代物理研究所气体探测器组研制了一种大型位置灵敏的平行板雪崩计数器(PPAC)。它主要由中心阴极和X,Y位置阳极构成,灵敏面积为244 mm×284 mm,阴极为双面镀金1.5 μm厚的Mylar膜,阳极为直径20 μm,间距1 mm的镀金钨丝。位置读出选用延迟块读出法。这种探测器经测试在灵敏面积内位置分辨小于4 mm,时间分辨为0.42 ns,已在兰州放射性束流线(RIBLL)上清华大学的核反应实验中使用。该实验中使用了主束40Ar直接轰击Au靶,产生裂变碎片,使用了4个这种大型位置灵敏的PPAC,用来探测裂变碎片的飞行时间和速度,实验表明,PPAC对裂变碎片有90.3%的效率,给出了裂变碎片的位置分布,为理论分析工作提供了非常好的实验数据。A kind of large position sensitive parallel plate avalanche counter(PPAC) was developed at Gas Detector Research Group, Institute of Modern Physics of CAS. Each of the detector with large sensitive area of 244 mm×284 mm, consists of one central cathode, X anode and Y anode. The cathode plane in the middle of detector is a 1.5 μm thick Mylar foil coated with a thin Au-layer on both sides. The position resolution of the PPAC is better than 4 mm, and the time resolution is 0.42 ns. The detectors were used in the fission experiment with 30MeV/u 40Ar beam bombarding on a gold target to measure the velocity of the fission fragments at Radioactive Ion Beam Line In Lanzhou(RIBLL). Four PPACs were used and the experiment result showed that a rather high detection efficiency (90.3%) is achieved. The position distribution of fission fragments is given by PPACs, which provides very good experimental data for further theoretical analysis.  相似文献   

2.
A two dimensional multi-wire proportional chamber with delay line readout was developed, which has a large sensitive area of 30 cm× 30 cm. Two cathode planes using printed circuit boards are orthogonally placed to give two coordinates of the impact point of the particle. Signals collected from the cathode strips are amplified and discriminated from two ends of the delay line at each cathode board. By recording the time difference between the two discrimination pulses and the common gate pulse from anode wires, a coordinate position was reconstructed, and a position resolution of better than 1 mm could be obtained in the whole sensitive area along the anode wires.  相似文献   

3.
A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80mm×80mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a (55)Fe X-ray source and a 200 MeV/u(12)C beam from CSRm. A position resolution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.  相似文献   

4.
描述了RIBLL终端大型探测器之一的大面积闪烁光纤阵列探测器(LASFA)的工作原理和结构特点, 报道了LASFA的研制以及单元性能的改进与测试。 LASFA具有很高的时间分辨和空间分辨能力, 可以很好地测量RIBLL终端各种轻带电粒子的信息。 The principles and structure characteristics of Large Area Scintillating Fiber Array(LASFA) detector at RIBLL (Radioactive Ion Beam Line in Lanzhou) are described. The development of LASFA and the characteristics of the scintillating fibers unit are reported. LASFA can be used to detect the light charged particles at RIBLL terminal due to its good time and spatial resolutions.  相似文献   

5.
介绍了一种基于THGEM的X射线光斑寻迹探测器,用于X射线单光子计量技术研究和测量,探测器有效面积200 mm×200 mm,采用128路基于ASIC和FPGA的高速读出电子学,探测器分为中间高分辨区和外围低分辨区两部分,两部分共用一套读出电子学。实验在中国计量科学研究院利用X光机产生的束线,测试光斑位置、光斑精细分布以及探测器的位置分辨。实验结果表明,探测器实现了同时对光斑寻迹和光斑的精细测量,探测器中间高分辨区x方向的位置分辨率为0.63 mm(FWHM),y方向位置分辨率为0.62mm(FWHM),探测器各项性能指标均达到了预期目标。This paper introduces the detector of X-ray spot tracing based on the THGEM. It is used for X ray single photon measurement technology research and measurement with an effective area of 200 mm×200 mm. The circuit board has 128 array of high speed readout electronics based on ASIC and FPGA. And it is divided into two parts:the middle area of high sensitive and the peripheral area of low sensitive. The two parts share a set of readout electronics. The experiment tests the position and the fine structure of the beam line produced by X ray machine in National Institute of Metrology. The results of the experimental show that the detector realizes both the spot tracing and the fine structure of the spot. The position resolution is 0.63 mm in x direction and 0.62 mm in y direction in high sensitive of the detector, which achieve the desired goal of preliminary design.  相似文献   

6.
介绍了一种双维位置灵敏CsI(Tl)闪烁探测器, 利用GEANT4对它进行了蒙特卡罗模拟, 得到了RIB 17N的位置分布谱及探测器的空间位置分辨, 模拟结果与实验测量值很好地吻合。给出了影响探测器分辨的主要因素及改进方案。A two dimensional position sensitive CsI(Tl) scintillation detector readout with PSPMT was introduced. The performance of detector was simulated by using Monte Carlo code GEANT4. The position spectrum of RIB 17N and the detector’s position resolution were obtained, and the simulation results accorded with the experimental ones. The main factors, which can affect performance of the detector, and some planned detector improvements were presented.  相似文献   

7.
中国散裂中子源( CSNS ) 的建造对中子探测器提出了非常高的要求,如更大的有效面积、二维位置灵敏、高计数率、高探测效率和低的 灵敏度等。与传统的模拟读出方法相比,数字法读出具有更高的计数率, 更小的数据传输量,更简单的电子学设计以及更高的信噪比。对数字法读出进行了理论计算,利用GEM探测器的原始数据分析了数字法读出的位置分辨率与读出条宽度的关系。结果表明,数字法读出对于位置分辨要求较低( 小于4 mm) 的大面积位置灵敏探测器是一种较好的选择,如CSNS 小角谱仪探测器。Efficient thermal neutron detectors with large area, two-dimensional position sensitive, high counting rate high detection efficiency and low gamma sensitivity are required to satisfy the demands for the China Spallation Neutron Source (CSNS). Compared with the traditional analog readout method, the digital readout method has the advantages of higher counting rate, smaller quantity of data transmission, simpler readout system and higher signal to noise ratio. The theoretical analysis of the digital readout method is reported in this paper. Used the raw data of GEM detector, the relationship between the position resolution and the width of the readout strip was studied. The results indicate that the digital readout method could be a good choice for the large area position sensitive detector where the requirement of position resolution is less than 4 mm, e.g. the detector of Small-Angle Neutron Scattering (SANS) diffractometer of CSNS.  相似文献   

8.
Three large sized glass resistive plate chambers (RPCs) are built and applied to measure the spatial resolution of the detector. The readout strips are collected to a LC delay-line and the time difference is used to determine the position. Cosmic rays are triggered by a set of two scintillation counters and the coincidently measured positions from the three RPCs are used to deduce the position uncertainty. In average a spatial resolution of 0.90 mm (FWHM) is obtained for a single RPC, with a good uniformity across the detection area. This result suggests that large sized glass RPC operating in the avalanche mode is a promising candidate for the muon tomography detection system.  相似文献   

9.
气体探测器有成本低廉、制备简单、性能可靠和方便使用等特点。研制了一种5层板结构的延迟线平行板雪崩电离室(PPAC),用于兰州放射性束流线(RIBLL)上开展的实验。在57.6 MeV/u的6He束流条件下测试了这种探测器对高能轻粒子的适用性,得到了位置分辨为1.8 mm (FWHM), 时间分辨为2.6 ns, 以及可靠的探测效率。The gas detectors have the characteristics of low cost, easy preparation, reliable capability and convenient for use etc. A delay line parallel plate avalanche counter(PPAC) with five plates has been developed for the experiments at Radioactive Ion Beam Line in Lanzhou(RIBLL). The applicability of counter for high energy light ion has been tested with 57.6 MeV/u 6He beam. A position resolution of ~1.8 mm(FWHM) and a timing resolution of ~2.6 ns are achieved. The detection efficiency is reasonable.  相似文献   

10.
针对高流强粒子束与绝缘毛细管相互作用的特点, 设计制作了一套64通道一维位置灵敏电流分布探测器及其配套的数据获取系统, 该探测器可分辨最小直径为1 mm的束斑, 通过数据获取系统可实现可视化自动数据采集。 用2 nA和200—2000 eV电子对探测器进行了定标, 并用10 μA和2000 eV的电子束穿越锥形毛细管后的出射电子, 对探测器及数据获取系统进行测试, 获得了出射粒子的位置分布谱及能量信息。 A 64 channel position sensitive current distribution detector with 1 mm position resolution was developed, while the data acquisition system is based on the LabVIEW software. The test result obtained by using a 2 nA, 200—2000 eV electron beam deflecting by different voltages and the position spectra of 10 μA, 2000 eV electrons transmitted through a glass capillary was measured. The result indicated that the detector can be used to detect the charged particles with strong beam current through the capillary.  相似文献   

11.
For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector.  相似文献   

12.
A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mmx200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the 55Fe X-ray test of the detector.  相似文献   

13.
 介绍了北京正负电子对撞机直线加速器附设e,p试验束多丝室的结构及工作机理。该室间隙6 mm,窗口面积80 mm×80 mm,位置灵敏面积50 mm×50 mm;阳极丝和阴极丝分别采用直径为20 mm和50 mm镀金钨丝,阳极丝距2 mm,阴极丝距0.7 mm,每6根阴极丝并联构成阴极条,阴极条间距4.2 mm。采用阴极条感应重心读出分辨位置,对5.9 keV的γ光子,获得优于0.3 mm (FWHM)的位置分辨;对1.1 GeV电子束流,获得0.224 mm (FWHM)的位置分辨。  相似文献   

14.
In a multi-wire proportional chamber detector(MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector's stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure3 He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate,portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable.  相似文献   

15.
二维位置灵敏硅探测器的应用研究   总被引:2,自引:0,他引:2  
对二维位置灵敏硅探测器进行了239Puα源刻度测试,并在弹性散射实验中使用了二维位置灵敏硅探测器.考察了两种定位方法在实验中与测试中的一致性.测量了二维位置灵敏硅探测器的能量分辨率、位置分辨率和位置畸变.对位置畸变进行了定性理论解释.  相似文献   

16.
通过模拟研究,找到了一种采用非均匀电极高压来改善探测器视差效应的方法;考察了该方法对多丝正比室的电子收集效率、增益一致性等性能的影响。结果表明:该方法可以显著减小探测器的视差效应,不会影响探测器的电子收集效率,引起的阳极丝增益一致性的变化也基本不会对探测器的总体性能造成影响。  相似文献   

17.
S S Desai  J N Joshi  A M Shaikh 《Pramana》2002,59(4):611-619
A 2-D multi-wire position sensitive detector for X-ray diffraction and small angle X-ray scattering studies is described. The detector has an active area of 100 mm × 100 mm and consists of an anode plane with 10 μm SS wires at 3 mm spacing and a pair of orthogonal cathode readout planes with 25 μm SS wires placed at 1.5 mm spacing. The position information is obtained using charge division method and recorded using a laboratory built data acquisition system. The resolution and gas gain was measured for 5.9 keV X-rays (55Fe-source) as a function of the anode wire voltage and gas pressure. It was observed that the proportional region of the PSD at 100 kPa pressure extended up to a high voltage value of around 1.5 kV and it shifted to high values up to 2 kV for gas pressure of 300 kPa. The energy resolution improved from 18% (FWHM) to 12% with increase in pressure. The spatial resolution of the PSD also showed improvement, with a value of 1.2 mm × 1.4 mm at 300 kPa gas pressure. A maximum gain of 5 × 104 is obtained.  相似文献   

18.
RIBLL1 experimental setup consists of RIB identification system,secondary target control system and secondary reaction products measurement system.The high gain x-y position sensitive PPAC with delay cable grouped readout,the scintillation foil time pickup detector focusing with ellipsoidal surface,the traverse field IC,the large area two dimensional position sensitive scintillatillator with PMT matrix readout,the Compton suppressed HPGe γ-ray detectors and twin longitudinal field iC are major components.This setup has been installed at RIBLL1.The performance measurements and test experiments are in progress.  相似文献   

19.
一种新型二维X射线探测器   总被引:1,自引:0,他引:1  
侯瑶 《光子学报》2001,30(9):1138-1140
本文建立一种新型X射线探测器,它是一种矩阵寻址方式的二维探测器,由两块玻璃基板组成,分别称作阴极板和阳极板,阴极板内侧镀有行电极和X射线阴级(例如CsI),阳极板上有寻址电极,障壁,两块基板对位封接,使行电要与寻址电极互相垂直,封接后先抽高真空,然后充入氩气与CO2混合气体,本探测器具有薄,轻,图象无畸变并可以利用PDP显示器件的工艺制作大尺寸器件及大量制造等优点。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏