首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Summary Retention behavior of anions and cations on anion-exchangers modified with dextran sulfate has been investigated. Retention of anions was remarkably reduced by the modification, and the retention factor decreased with decreasing eluent concentration when sodium sulfate was used as the eluent. Cations were also retained on the modified stationary phase, and alkali and alkaline-earth metal ions were separated using copper sulfate or tris(2,2′-bipyridyl)ruthenium chloride as eluent. The size of the dextran sulfate strongly affected the retention behavior of analyte ions.  相似文献   

2.
An ion chromatography method for rapid and direct determination of iodide in seawater and edible salt is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm x 0.32 mm i.d.) modified with poly(ethylene glycol) (PEG). Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration when lithium chloride, sodium chloride, potassium chloride, sodium sulfate, magnesium sulfate were used as the eluent, while it decreased with increasing eluent concentration when ammonium sulfate was used as the eluent. The detection limit for iodide obtained by injecting 0.2 microl of sample was 9 microg/l (S/N = 3). The present method was successfully applied to the rapid and direct determination of iodide in seawater and edible salt samples. Partition may be involved in the present separation mode.  相似文献   

3.
An ion chromatographic method for rapid and direct determination of iodide in seawater samples is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm × 0.32 mm i.d.) modified with polyoxyethylene oleyl ether, with an aqueous solution of 300 mM sodium chloride as eluent and using UV detection at 220 nm. Samples containing iodate, nitrate, iodide and thiocyanate were eluted within 8 min, and the relative standard deviations of the retention time, peak area and peak height were all smaller than 4.19% for all of the analyte anions. Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention time of analytes. When inorganic eluents, such as ammonium chloride, ammonium sulfate, lithium chloride, sodium chloride, sodium sulfate, magnesium chloride and magnesium sulfate were used, the retention time of analytes increased with increasing eluent concentration. The limit of detection of iodide was 19 μg l−1 (S/N = 3), while the limit of quantitation was 66 μg l−1 (S/N = 10). The present method was successfully applied to the rapid and direct determination of iodide in seawater samples.  相似文献   

4.
The common eluents used with a bifunctional ion-exchange column (IonPac CS5A) for separating transition metals are pyridine-2,6-dicarboxylic acid and oxalic acid (Ox). When Ox is used, cadmium and manganese co-elute. Although much research has been done to overcome the Cd2+–Mn2+ co-elution problem, the role of lithium hydroxide in separating the transition metals has received little attention. In this study, it is found that when the Ox concentration is higher than 35 mM, Cu2+ elutes after Pb2+ and Ox plays a predominant role in the retention behavior of the seven metals. When Ox concentration is lower than 35 mM especially when its concentration (25 mM) is half of the usually used standard concentration (50 mM), Cu2+ elutes before Pb2+, and at the same time, Mn2+and Cd2+ can also be baseline separated. Lithium hydroxide plays a predominant role in the separation of the metals separated by cation exchange. So, lithium hydroxide is used to adjust the pH of the eluent. The use of an isocratic elution (25 mM Ox/LiOH/2 mM Na2SO4, pH 3.88) allows the separation of seven metals (Cu2+, Pb2+, Co2+, Mn2+, Cd2+, Zn2+ and Ni2+) in a single run. The effects of inorganic modifiers such as NaNO3, Na2SO4 and Na4P2O7 on retention behavior of the metals are also investigated.  相似文献   

5.
Seven theoretical retention models, namely the linear solvent strength model (using the dominant equilibrium approach and competing ion effective charge approach), the dual eluent species model, the Kuwamoto model, the extended dual eluent species model, the multiple species eluent/analyte model and the empirical end-points model, were used to describe the retention behaviour of anions in suppressed ion chromatography (IC). An extensive set of experimental retention data was gathered for 24 anions (fluoride, formate, bromate, chloride, hexanesulfonate, bromide, chlorate, nitrate, iodide, thiocyanate, perchlorate, sulfite, succinate, sulfate, tartrate, selenate, oxalate, tungstate, phthalate, molybdate, chromate, thiosulfate and phosphate) on a Dionex AS4A-SC column using carbonate eluents of varying concentration and HCO3:CO32− ratios. Statistical comparison of the predicted and experimentally obtained retention factors showed that the performance of the theoretical models improved with the complexity of the model. However the empirical model (in which a linear relationship is assumed between the logarithm of retention factor and the logarithm of eluent strength, but the slope is determined empirically) gave the most consistent performance across the widest range of anions. The empirical end-points model was also shown to be the most satisfactory model due to its low knowledge requirements and easy solution. Compared with non-suppressed IC (see Part I), the retention behaviour in suppressed IC was found to be easier to model by all retention models.  相似文献   

6.
A retention model is derived for complex anions eluted from an anion-exchange column with multiple ionic eluents containing hydrogencarbonate, carbonate, and hydroxyl species and the sample solution, containing transition metals, anions and complexing ligand. The theory is based on the generalized ion-exchange equilibrium, protonation and complex-formation equilibria. The unknown parameters of chromatographic ion-exchange equilibrium constants for sample and eluent species are determined from the experimental retention data by iterative minimization, using a non-linear regression algorithm. The model was utilized to predict the retention behaviour of CdEDTA2−, CoEDTA2−, MnEDTA2− and NiEDTA2− ions. The capacity factors of complex ions were determined for wide ranges of pH values and eluent concentrations. Good agreement was obtained between the observed and predicted retentions.  相似文献   

7.
Inorganic anions were separated on hydrophobic stationary phases such as triacontyl-functionalized silica. Eluent conditions were examined in detail, and iodate, nitrate, iodide, and thiocyanate could be separated by using aqueous solutions. The effect of the eluent concentration on the retention of analyte anions was examined for a wide range of sodium sulfate concentrations of up to 1 M. The retention factor of hydrophobic anions decreased with increasing sodium sulfate concentration in the lower concentration region, while it increased with increasing sodium sulfate concentration in the higher concentration region. The addition of a small amount of an organic substance such as acetonitrile and tetraethylene glycol increased the retention of iodide and thiocyanate, while the addition of alcohols decreased their retention. Operating at lower temperature also increased the retention of analyte anions. It was expected that inorganic anions were retained on the stationary phase via hydrophobic interactions. The retention mechanism was discussed, considering the results obtained.  相似文献   

8.
A nonlinear function retention model for anion chromatography is developed, which is able to predict the retention behavior of polyvalent weak acid anions using sodium hydroxide as eluent. The relationship between the retention factors of phosphate and resorcinol and eluent concentration was studied with sodium hydroxide as the eluent. Both retention factors of the analyte anions first increase then decrease with the increase of sodium hydroxide concentration. The estimated values agree with the measured values with correlation coefficients for phosphate and resorcinol of 0.9920 and 0.9916, respectively, which shows the nonlinear function model is a useful addition to the theory of anion chromatography. The model is able to optimize the separation of polyvalent weak acid anions.  相似文献   

9.
The retention behavior of biologically relevant monovalent (formic, acetic, propionic, lactic and pyruvic) and divalent (oxalic, malonic, succinic, fumaric, maleic and tartaric acids) car☐ylic acids together with inorganic analytes (chloride and sulphate) has been studied. The separation was performed on a latex-based strong anion-exchange resin using carbonate buffer systems in suppressed IC. The retention behaviour of analytes was investigated at different pH values and [HCO3]+[CO32−] concentrations. A theoretical model, involving ion-exchange equilibria of sample and eluent anions, was derived and applied to the chromatographic data obtained. Chromatographic ion exchange selectivity values were determined and retention data were calculated for the anions using different carbonate eluent conditions. The average of errors between the predicted and the measured retention volumes of the analytes studied does not exceed 4.0%. The study effectively characteristics the behaviour of different analytes under elution conditions of practical importance.  相似文献   

10.
A vitamin U-bonded stationary phase was prepared and the retention behavior of inorganic anions was examined using ion chromatography. Inorganic anions were retained on the vitamin U-bonded stationary phase under acidic as well as neutral eluent conditions in the ion-exchange mode. The elution order of the examined anions under neutral eluent conditions was nearly the same as that observed in common ion exchange mode, while the elution order observed under acidic eluent conditions was completely different from that observed in common ion exchange mode. The retention of the analyte anions under the neutral eluent conditions was due to the sulfonium groups of the vitamin U, while protonated primary amino groups caused retention of the analyte anions with different selectivity under acidic conditions. The retention factor of the analyte anions increased with decreasing eluent concentration under both eluent conditions. The present system was applied to the determination of bromide and nitrate contained in seawater.  相似文献   

11.
An ion chromatography method was developed to determine trace anionic contamination in matrices that have a high concentration of nitrate ion. Contaminant anions of interest were separated on an IonPac AS15 high-capacity anion-exchange column and detected by suppressed conductivity detection. An EG40 eluent generator was used to prepare high-purity and carbonate-free potassium hydroxide. Using the EG40, performance at trace levels was enhanced because background conductivity decreased and retention time reproducibility improved. Trace anionic contamination from the mobile phase was minimized when using the eluent generator compared to using conventionally prepared sodium hydroxide eluents. The signal-to-noise ratio was also improved with the use of a temperature controlled conductivity cell and chromatography hardware in the microbore (2-mm) format. The eluent concentration was optimized to separate the contaminant anions from the excess of the nitrate matrix ions. The procedure was demonstrated for a solution of reagent-grade sodium nitrate and high-purity 0.7% nitric acid. Method detection limits for chloride, sulfate and phosphate of 150 μg/l and lower were achieved.  相似文献   

12.
Acetylated amino acids (Nac-AA) are separated as anions on a reversed stationary phase from a mobile phase containing a quaternary ammonium (R4N+) salt as a mobile phase additive. If the counteranion accompanying the R4N+ or ionic strength salt is detector active than the separated NAc-AA derivatives can be detected by an indirect detection strategy. Variables influencing the separations are NAc-AA side chain structure and the mobile phase parameters such as hdyrophobicity of the alkyl groups in the R4N+ salt, R4N+ salt concentration, counteranion eluent strength, counteranion concentration, solvent composition, and pH. Indirect detection is influenced by these same mobile phase parameters as well as the properties of the detector active counteranion. The detection limit for indirect photometric detection at 287 nm using a tetrapentylammonium salt with a disodium 1,5-naphthalenedisulfonate—sodium benzoate counteranion mixture was about 70 pmol of NAc-AA depending on the amino acid injected as a 10-μ1 sample.  相似文献   

13.
The utility of cation chromatography has been developed by the application of -histidine as a multiprotic and dipolar (zwitterionic) eluent component. The method simplifies the cation analysis. The chromatographic characteristics of this system were studied in detail with a view to determining the selectivity and the mechanism by which the cations (Na+, K+, Mg2+, Ca2+) are retained. Complete separations were observed in the isocratic run over the eluent concentration range 3.0–6.0 mM at pH below 2.0. Sensitive detection was achieved using suppressed conductivity at the pH of isoelectric point of the histidine. Retention equations are derived for mono- and divalent cations eluted from ion-exchange separation column with multiple ionic eluents. The theory is based on the extension of ion-exchange equilibrium by protonation equilibria. The selectivity data for analyte and eluent species are determined using the model from the experimental retention data by computer-assisted iterative calculations. The model was utilized to predict retention data. The results in three-dimensional retention surfaces together with species distribution graphs are presented.  相似文献   

14.
A monitoring system consisting of a portable-type conductimetric ion-exclusion–cation-exchange chromatographic (CEC) analyzer and a meteorological satellite data analyzer has been investigated for the evaluation of the effects of acid precipitation on natural and urban environments in East Asia. The portable ion-exclusion–CEC analyzer uses a polymethacrylate-based weakly acidic cation-exchange resin column in the H+-form and a weak-acid eluent (tartaric acid–methanol–water) and is applied for the simultaneous determination of anions (SO42−, NO3, and Cl) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) in precipitation transported from mainland China to central Japan, as mapped by the meteorological satellite data analyzer. Linear calibration graphs of peak area versus concentration for anions and cations were observed in the concentration range 0–1.0 mM for the anions and 0–0.5 mM for the cations. Detection limits at a signal-to-noise ratio of 3 were in the range 5.18–12.1 ppb for the anions and 6.58–16.5 ppb for the cations. The practical utility of this monitoring system is presented.  相似文献   

15.
A novel bipolar stationary phase (HCPS–MO) was prepared by impregnation of hypercrosslinked polystyrene (HCPS) with methyl orange (MO; 4-dimethylamino-4′-sulfoazobenzene) and its ion-exchange properties were studied. Simultaneous separation of cations and anions on HCPS–MO is possible, although it behaves preferentially as a cation-exchanger. Unusual selectivity of HCPS-MO for alkali and alkaline-earth metal cations: Na++K++4++ and Mg2+2+2+2+ was observed. The effect of temperature on retention of alkali and alkaline-earth metal cations was studied. Separation of Na+, K+, Rb+, NH4+, Cs+, Mg2+ and Ca2+ on HCPS–MO with diluted cerium(III) nitrate solution as an eluent in single run is presented.  相似文献   

16.
The objective of this study was to investigate the retention of phosphate anions, H2PO4 and HPO42−, by nanofiltration. The first part of this study deals with the characterisation of the NF200 membrane used in permeation experiments with aqueous solutions of neutral organic and charged inorganic solutes. In the second part the effects of feed pressure, ionic strength, concentration and pH on the retention of phosphate anions were investigated. Results show that the membrane is negatively charged, its pore radius is around 0.5 nm and the retention order for the salts tested was R(Na2SO4) > R(NaCl) > R(CaCl2). The retentions of phosphate anions are in the order of 85% for H2PO4 and 96% for HPO42−. They are relatively high when compared to retentions of other anions with the same charge. The retentions of phosphate anions, particularly the monovalent species, depend on the chemical parameters (feed concentration, ionic strength, and pH) and applied pressure. The experimental data were analysed using the Speigler–Kedem model and the transport parameters, i.e., the reflection coefficient (σ) and solute permeability (Ps) have been determined.  相似文献   

17.
研究了Keggin结构钼磷杂多化合物Na5[PM(H2O)Mo11O39]·nH2O(M=Mn2+,Co2+,Ni2+,Cu2+,Zn2+在溶液中的氧化还原性质,发现环境的改变可对杂多阴离子的极谱半波电位产生影响,其影响程度的大小决定于过渡金属离子本身的性质。取代后的钼磷杂多阴离子的半波电位顺序为Ni2+>Co2+>Zn2+>Cu2+>Mn2+,pH值的变化影响氧化还原性质,并阐述了变价金属Cu2+对杂多阴离子氧化还原性质的影响.  相似文献   

18.
The rapid separation of inorganic anions was determined by capillary ion chromatography using monolithic silica capillary columns modified with dilauryldimethylammonium bromide. The stability of the modified stationary phase was satisfactory owing to a strong hydrophobic interaction between the lauryl groups of the reagent, even if the eluent did not contain dilauryldimethylammonium ion. Bromide in seawater samples could be determined by the present system. The repeatability of a retention time of bromide for six successive measurements was around 1.8% when a 500 mM sodium chloride aqueous solution was used as the eluent. Seawater samples were directly injected onto the prepared column without any interference of matrix ions, because an aqueous solution of high-concentration sodium chloride could be used as the eluent. Bromide in seawater samples could be determined within 2 min.  相似文献   

19.
傅厚暾 《色谱》2002,20(5):423-426
 对几年前建立的使用碳酸钠 碳酸氢钠淋洗液体系时阴离子保留值预测模型进行了改进 ,改进了的预测模型能适用于更宽的碳酸钠 碳酸氢钠浓度变化范围。通过实验测得使用不同浓度的碳酸钠 碳酸氢钠作为淋洗液时硝酸根、硫酸根、磷酸根、砷酸根、草酸根、硒酸根、碘离子等 7种阴离子的保留因子数据 ,对数据进行了二元线性回归处理 ,在较宽的淋洗液浓度范围内 ,硝酸根、硫酸根、草酸根、硒酸根、碘离子的保留因子和碳酸钠 碳酸氢钠浓度的相关系数都在 0 999以上 ,磷酸根、砷酸根的保留因子和碳酸钠 碳酸氢钠浓度的相关系数分别为 0 9971和0 995 7。  相似文献   

20.
以硅胶为核,马来海松酸丙烯酸乙二醇酯和甲基丙烯酸为功能单体,采用涂覆悬浮聚合法合成了核壳型SiO2@松香基阳离子交换树脂(SiO2@RCER),研究了其对水中微量Cd2+的静态吸附性能。结果表明,在Cd2+溶液浓度为0.5 mg·L-1,pH=6.0,温度为303 K,吸附剂用量为10 g·L-1时,Cd2+去除率可达到100%;SiO2@RCER对Cd2+的吸附符合准二级动力学方程以及Langmuir吸附等温线,表明吸附过程为单分子层化学吸附。吸附前后材料的XPS图谱表明:SiO2@RCER对Cd2+吸附主要涉及Na+以及溶液中的Cd2+的阳离子交换。该吸附剂在对Cd2+、Pb2+浓度超标的矿区废水吸附处理后,高毒重金属浓度均达到国家生活饮用水水源水质一级标准(CJ3020-93),其他离子浓度也有所降低。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号