首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The ability of reversed-phase high-performance liquid chromatography (RP-HPLC) to separate some positionally isomeric disaturated and monounsaturated triacylglycerols (TAGs) as intact species is demonstrated for the first time. Mobile phases of acetonitrile modified with methanol, ethanol, 2-propanol, 1-propanol, 1-butanol, acetone, or dichloromethane were tested for the separation of POP-PPO, PLP-PPL, PEP-PPE, and PDP-PPD (P-palmitic, O-oleic, L-linoleic, E-eicosapentaenoic, D-docosahexaenoic acid residue) on a single RP-HPLC column. The resolution improved with increasing number of double bonds in the acyl residues. While POP and PPO were only partially resolved, PDP and PPD were fully separated with all tested mobile phases, except those containing methanol. Also separated were the four TAGs having the same equivalent carbon number (ECN = 42), PEP, PPE, PDP, and PPD, on a single RP-HPLC column with mobile phase acetonitrile-2-propanol (70:30, v/v) at 0.8 mL/min. In all cases the isomer with the unsaturated acyl residue in either 1- or 3-position was retained more strongly than the respective 2-isomer.  相似文献   

2.
An HPLC-based method has been developed for composition analysis of six positional isomers of phosphatidylinositol (PI), of which the phosphatidyl group was connected to different positions of the myo-inositol moiety. The method employed a combination of two types of HPLC analyses. One was direct separation of the six PI isomers into four peaks of 1(3)-PI, 2-PI, 4(6)-PI and 5-PI on a normal-phase silica gel column. The second method was for the separations of 1-PI from 3-PI and 4-PI from 6-PI, which were not separable on the normal-phase column. This method involved conversion of PI isomers into pentakis-(R)-1-phenylethylcarbamate (PEC) derivatives, which were separated on a reversed-phase column. Using the established method, positional specificity of several engineered phospholipases D in enzymatic synthesis of PI from myo-inositol and phosphatidylcholine was investigated. This was performed by analyzing the isomeric composition of PIs synthesized by the mutant enzymes. Among five mutant enzymes tested, two showed strong specificity to 1-OH, one showed moderate preference to 1-OH, one preferred 3-OH, and one showed broad specificity towards 1-, 3-, 4- and 6-OH.  相似文献   

3.
N. Mellor 《Chromatographia》1982,16(1):359-363
Summary Many analysts are not taking full advantage of the high speed possibilities of modern LC. Some analytical procedures reported in the literature, and many in regular use in control laboratories, could be achieved in less time without loss in precision. Some factors which affect retention times are discussed and the advantages and disadvantages of employing shorter column lengths and finer packing materials in reversed-phase HPLC are examined. The effect on efficiency of increased flow rates with 10,5 and 3 m ODS materials is shown. The ability to couple shorter column lengths without loss of efficiency is also demonstrated. This allows a minimum length to be selected that gives adequate resolution. Examples of high speed separations are shown and limitations in state of the art HPLC equipment and chromatographic data systems are discussed briefly.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

4.
Summary Differences in retention time and relative elution order were observed when a standard mixture of 11 PAH was injected on three C-18 columns from different manufacturers under equivalent conditions.Working on a grant from the Swedish Natural Science Research Council.  相似文献   

5.
Summary The chromatographic behavior of ten peptide isomers was investigated using isocratic eluting with reversedphase high-performance liquid chromatography. These peptides are growth hormone releasing factor, consisting of 29 amino acid residues and its isomers where on amino acid residue in the sequence was replaced with the corresponding D-amino acid. Linear relationship was observed between the logarithm of the capacity factors of the isomers and the acetonitrile concentration in the mobile phase with correlation coefficients of 0.995–0.998. The regression coefficients were almost the same for all the isomers with a relative standard deviation of 5.3%. These results suggest that the chromatographic behavior of peptide isomers is also predictable from the solvophobic theory. The regression coefficient reflects the molecular weight and the Y-intercept represents the hydrophobicity of the isomer. The peptide isomers can be separated from one another, based on the differences in the hydrophobicity of each isomer.  相似文献   

6.
Summary The dependence of column efficiency on the eluent (MeOH/H2O) composition in a reversed-phase liquid chromatography system within a wide concentration range has been systematically examined. It is shown that when the intracolumn effect of mass transfer and diffusion is the main factor controlling band broadening the column efficiency decreases with the increase of the viscosity of the MeOH/H2O mixture; on the other hand, when the extra-column effect is the main factor an increase in the viscosity of the eluents will help in improving column efficiency. The column efficiency is also related to the properties of the sample.  相似文献   

7.
Ge L  Yong JW  Tan SN  Yang XH  Ong ES 《Electrophoresis》2005,26(9):1768-1777
A micellar electrokinetic chromatography (MEKC) method was developed for the separation of six positional isomers of hydroxylated aromatic cytokinins (topolin and topolin riboside), including ortho-topolin, meta-topolin, para-topolin, ortho-topolin riboside, meta-topolin riboside, and para-topolin riboside. Optimum resolution and analysis time (ca. 20 min) for the six aromatic cytokinin standards were achieved with a running buffer at pH 8.0 consisting of 20 mM boric acid, 50 mM sodium dodecyl sulfate (SDS), and 20% v/v methanol. The method has good reproducibility and has been successfully applied to detect the presence of a putative ortho-topolin in coconut water extract sample purified using C(18) and mixed-mode solid-phase extraction (SPE) columns. Other advantages of this MEKC method are short analysis time, low solvent consumption, and separation of positional isomers which could be achieved by a simple aqueous buffer system without the use of expensive chromatographic columns. In addition, a high-performance liquid chromatography (HPLC) method with baseline separation of the six topolin and topolin riboside standards was developed for the confirmation of the endogenous ortho-topolin in coconut water sample. Finally, the presence of ortho-topolin was further confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) based on its characteristic fragmentation pattern.  相似文献   

8.
A normal-phase HPLC system using an amino column has been developed to characterise oligomers of poly(ethylene glycol)s (PEGs) of average Mr 400 to 2000 with derivatisation by dinitrobenzoate. Normal-phase HPLC with gradient elution using ternary solvents of hexane, dichloromethane and methanol has produced a baseline resolution for oligomers of PEG 400, 600 and 1000, while PEG 1000 and 2000 were analysed by using binary solvents of acetonitrile and water. Mixtures of PEGs have been determined by these HPLC systems. PEG 400 in a textile finish has also been determined with satisfactory recovery. It has been found that the hydroxyl group of solvents in normal-phase HPLC plays an important role in resolution and retention of PEG oligomers. Derivatisation efficiency for PEGs by dinitrobenzoyl chloride and quantitative determination of derivatised PEGs by HPLC have been studied. A reversed-phase (RP) mode of HPLC was examined for determination of PEG 400 oligomers. The normal-phase system provided greater resolution for oligomers of PEGs.  相似文献   

9.
Separation of porphyrin isomers by high-performance liquid chromatography   总被引:2,自引:0,他引:2  
A high-speed reversed-phase high-performance liquid chromatographic method using an octadecylsilyl 3 cm long (3 microns particle size) column to separate the free acids of uroporphyrins I and III and coproporphyrins I and III from each other, and from the type I isomers of several other porphyrin carboxylic acids, is described. Separation of the porphyrins was achieved in less than 8 min, and injections were possible every 12 min. The detection limits of uroporphyrin, coproporphyrin, and mesoporphyrin were 75, 45, and 35 fmol (at a signal-to-noise ratio of 2), respectively. Application of the method to the determination of urinary and liver porphyrin patterns is shown.  相似文献   

10.
Complete regioselective separation of five pairs of isomeric dipalmitoyl polyalkenoyl glycerols with two to six double bonds in the unsaturated acyl residues has been achieved by RP-HPLC on a single ODS column. Four ODS columns with stationary phases containing different percentages of free silanol groups have been tested. Binary mobile phases of ACN admixed with dichloromethane, tetrahydrofuran, 1-propanol, 2-propanol, ethanol, or acetone have been examined. The choice of modifier depended on the nature of the stationary phase. The more polar solvents were better suited for stationary phases with higher percentage of free silanol groups. Isomeric species were eluted according to chain length, number of double bonds, and the position of the unsaturated acyl chain in the glycerol molecule. Retention increases in the order 20:5 < 22:6 < 18:3 < 20:4 < 18:2. Within each isomeric pair, the species with unsaturated acyl chain occupying either the sn-1- or the 3-position were retained preferentially. Complete simultaneous regioselective separation of 10 isomeric triacylglycerols in a single isocratic run on a single ODS column was demonstrated.  相似文献   

11.
Summary A rapid and specific reversed-phase high-performance liquid chromatographic method (RPHPLC) is described for the determination of mebeverine hydrochloride in tablets. Elution was performed on an octyl silane column with a methanol-water mixture (75-25), containing 0.05% hexylamine as silanol-blocking agent, adjusted to pH 5.0 with phosphoric acid. The method gave accurate, precise and reproducible results. The mean recovery of the drug from six synthetic tablet mixtures was 100.0% with a relative standard deviation (RSD) of 0.94%. In order to test the specificity of the method, the interference of the degradation compounds of mebeverine hydrochloride and of the intermediates from the synthesis was investigated. None of them did interfere. By means of mass spectrometry and UV-spectrophotometry, the degradation compounds of mebeverine were identified as veratric acid and as 4-|ethyl-[2-(4-methoxyphenyl)-1-methylethyl]amino| 1-butanol. The stability study proved that mebeverine hydrochloride is very stable in tablets; the tablets still contain more than 95% of the declared drug potency after storage for more than one year at 50°C.Colofac; Duspatal; Duspatalin  相似文献   

12.
Anthocyanins, which confer the characteristic color to red wine, can be used as markers to classify wines according to the grape variety. It is a complex separation that requires very high chromatographic efficiency, especially in the case of aged red wines, due to the formation of pyranoanthocyanins. A coelution between these kinds of compounds can affect the Rac/coum ratio of aged wines, and might lead to false results when classifying the wine variety. In 2007, the use of a novel mixed-mode ion-exchange reversed-phase column was reported to separate anthocyanins extracted from grapes of Vitis labrusca with different selectivity than C-18 columns. In the present work, the separation of anthocyanins including pyranoanthocyanins in young and aged Cabernet Sauvignon wines and other varieties is evaluated. The most interesting contributions of this research are the different elution order and selectivity obtained for anthocyanins and pyranoanthocyanins (only formed in wine), compared with those observed in C-18 stationary phases. Also interesting is the separation of the polymeric fraction, which elutes as a clearly separated peak at the chromatogram's end. However, a comparison with a high efficiency C-18 column with the same dimensions and particle size demonstrated that the tested mixed-mode column shows broader peaks with a theoretical plate number below 8000, for malvidin-3-glucoside peak, while it can be up to 10 times higher for a high efficiency C-18 column, depending on the column manufacturer. Under the tested conditions, in mixed-mode phase, the analysis time is almost twice that of a C-18 column with the same dimensions and particle size. A mixed-mode phase with increased efficiency should provide an interesting perspective for separation of anthocyanins in wine, due to its improved selectivity, combined with a useful role in a second-dimension separation in preparative anthocyanin chromatography.  相似文献   

13.
Silver ion chromatography, utilizing two commercially available HPLC columns connected in series, was used to separate a variety of triacylglycerol positional isomers. The isomers had a fatty acid composition of ABA and AAB, where A and B were fatty acids containing zero to three double bonds. Isocratic solvent systems of 0.5% to 1.0% acetonitrile in hexane were used to separate the triacylglycerol isomers. This methodology can be used to rapidly determine the isomeric purity of synthesized or isolated triacylglycerols and to isolate specific positional isomers.  相似文献   

14.
15.
16.
Six kinds of cytochrome c of different origin, i.e., bovine, chicken, dog, horse, rabbit and tuna, were subjected to separation by reversed-phase high-performance liquid chromatography on three commercial packing materials; octadecyl-, octyl- and cyanoalkyl-silicas. The effects of reversed-phase material, mobile phase and temperature on the separation of cytochromes c were examined. The parameters of the mobile phase were the organic modifier, the pH, the salt concentration and additives. Under optimal conditions, five of the six cytochromes c were resolved in 10 min. The relative retention values cannot be explained in terms of the relative lipophilicities of the side-chains of the amino acid residues.  相似文献   

17.
Chromatographic behavior and separation conditions of pyrimidine derivatives were studied by high-performance liquid chromatography using a reversed-phase column and a multiwave UV detector.  相似文献   

18.
Summary The influence of different reversed-phase packings and the addition of acidic modifiers to the mobile phase was observed on the separation of basic and neutral polypeptide antibiotics by gradient elution. A dependence of pore size, coverage, reaction type and endcapping of the packings was not observed. Nevertheless, not all reversed-phase packings were suitable for the separation of polypeptides, especially of basic molecules. The addition of phosphoric or perchloric acid to the mobile phase prevented adsorption of the basic polypeptide antibiotics on the stationary phase.  相似文献   

19.
When properly solubilized with trifluoroacetic acid (TFA), alpha- and beta-tubulin subunits from a variety of sources may be resolved at high yield by reversed-phase high-performance liquid chromatography (HPLC), using a Waters muBondapak C18 column and simple linear aqueous acetonitrile gradients containing TFA. The tubulin subunits are typically the most non-polar proteins present, with the beta-tubulin subunit eluting before the alpha. Column temperature above ambient improve both the resolution and the yield; less polar solvent systems do not. Tubulins not freely soluble in aqueous TFA may be solubilized in 6 M guanidine-hydrochloric acid with no change in retention time. Other columns with shorter carbon chain lengths and larger pore size produce a single, unresolved tubulin peak. Reversed-phase HPLC analysis provides an independent comparative evaluation of organelle-specific tubulins, with characteristic retention time differences observed between homologous ciliary and flagellar outer doublet tubulin subunits and also between them and their cytoplasmic counterparts.  相似文献   

20.
Summary On-column endcapping and derivatization or regeneration of C8 and C18 reversed-phase HPLC columns with newly introduced reagents were studied. These treatments can increase column life expectancy by restoring retention times and original chromatographic characteristics of the columns. This is illustrated by examples. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号