首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A microwave-assisted extraction (MAE) and ultra high performance liquid chromatography coupled with diode array detection and time-of-flight mass spectrometry (UHPLC-DAD-TOF-MS) method was developed for simultaneous determination of 14 phenolic compounds in the root of Pueraria lobata (Wild.) Ohwi and Pueraria thomsonii Benth. Operational conditions of MAE were optimized by central composite design (CCD). The optimized result was 65% ethanol as extraction solvent, 17 mL of extraction volume, 100 °C of extraction temperature and 2 min of hold time. A Zorbax SB C18 (50 mm × 4.6 mm I.D., 1.8 μm) and gradient elution were used during the analysis. The chromatographic peaks of 14 investigated compounds in samples were successfully identified by comparing their retention time, UV spectra and TOF mass data with the reference substances. All calibration curves showed good linearity (r > 0.9997) within the test ranges. The intra-day and inter-day variations were less than 1.77% and 2.88%, respectively. The developed method was successfully applied to determine the investigated compounds in 10 samples of Radix Puerariae Lobatae and Radix Puerariae Thomsonii, respectively. The result indicated that MAE and UHPLC-DAD-TOF-MS system might provide a rapid method for the quality control of Radix Puerariae.  相似文献   

2.
A liquid-phase microextraction method for the determination of trihalomethanes (THMs) including chloroform (CHCl3), bromodichloromethane (CHBrCl2), dibromochloromethane (CHBr2Cl) and bromoform (CHBr3) in water samples was developed, with analysis by gas chromatography-electron capture detection (GC-ECD). After the determination of the most suitable solvent and stirring rate for the extraction, several other parameters (solvent drop volume, extraction time and ionic strength of the sample) were optimized using a factorial design to obtain the most relevant variables. The optimized extraction conditions for 5 mL of sample volume in a 10 mL vial were as follows: n-hexane an organic solvent; a solvent drop volume of 2 μL; an extraction time of 5.0 min; a stirring rate of 600 rpm at 25 °C; sample ionic strength of 3 M sodium chloride. The linear range was 1-75 μg L−1 for the studied THMs. The limits of detection (LODs) ranged from 0.23 μg L−1 (for CHBr2Cl) to 0.45 μg L−1 (for CHCl3). Recoveries of THMs from fortified distilled water were over 70% for a fortification level of 15 μg L−1, and relative standard deviations of the recoveries were below 5%. Real samples collected from tap water and well water were successfully analyzed using the proposed method. The recovery of spiked water samples was from 73% to 78% with relative standard deviations below 7%.  相似文献   

3.
At the present study, a new and rapid headspace solvent microextraction (HSME), for the extraction and pre-concentration of the volatile components of plant sample into a microdrop was applied. The extraction occurred by suspending a microliter drop of the solvent from the tip of a microsyringe to the headspace of a ripen and powdered dry fruit sample (Iranian Pimpinella anisum seed) in a sealed vial for a preset extraction time, then the microdrop was retracted back into the microsyringe and injected directly into a GC injection port. The chemical composition of the HSME extracts were confirmed according to their retention indexes and mass spectra (EI, 70 eV); and quantitative analysis was performed by GC-FID.Parameters such as the nature of the extracting solvent, particle size of the sample, temperatures of the microdrop and sample, volume of sample and the extraction time were studied and optimized, and the method's performance was evaluated. The optimized conditions were: sample particle size, 1 mm; sample volume, 5 ml (in a 15 ml vial); sample temperature, 60 °C; microsyringe needle temperature, 0 °C; and extraction time, 10 min. Finally, accordingly, the percentage of trans-anethole (the major compound of P. anisum) and the relative standard deviation for extraction and determination of trans-anethole (seven-replicated analysis) were determined to be 90% and 3.9%, respectively.  相似文献   

4.
Fengli Hu 《Talanta》2009,77(4):1299-374
The chlorogenic acid (CA) in Honeysuckle is determined and identified by nano-liquid chromatography-electrospray ionization mass spectrometry (nano-LC-ESI/MS) after extraction with microwave-assisted extraction (MAE). As a new sample preparation method for Honeysuckle, the MAE procedure is optimized, validated and compared with conventional methods including reflux extraction (RE) and ultrasonic extraction (USE). It is found that MAE gives the best result due to the highest extraction efficiency within shortest extraction time (only 4 min). Here, CA is determined by nano-LC-ESI/MS based on the calibration curve of its authentic standard. The method linearity, detection limit, precision and recovery are studied. The results show that the combined MAE and nano-LC-ESI/MS method has a linearity (R2 0.991, 0.8-20 ng mL−1), a low limit of detection (0.5 ng mL−1), good precision (R.S.D. = 2.54%) and a recovery (84.8%). The experiment has demonstrated that the nano-LC-ESI/MS following MAE is a fast and reliable method for quantitative analysis of CA in Honeysuckle.  相似文献   

5.
Microwave-assisted extraction (MAE) has been evaluated as an alternative to dialysis for the extraction of polybrominated diphenyl ethers (PBDEs) and polychlorinated naphthalenes (PCNs) sampled by semipermeable membrane devices (SPMDs), using gas chromatography coupled to tandem mass spectrometry (GC-MS-MS).For MAE optimization a two level full factorial design 23, plus a centre point, which involves 11 randomized runs was used. The results showed that the temperature had a significant influence on the extraction of the nine PBDEs and four PCNs tested. Also, the solvent volume had a positive influence on the extraction of PBDEs and PCNs, but only in latter compounds, it achieves statistical significance. The time had only statistical significance for the most volatile specie studied, PCN-54. The selected MAE conditions (60 mL of hexane-acetone, 1:1 (v/v), 85 °C, 1 min, two cycles) lead to recoveries between 72 and 91% for PBDEs and between 96 and 103% for PCNs. The applicability of the MAE extraction was tested in field SPMDs deployed for 20 days in a sewage treatment plant.The MAE method developed is about 300 times faster than the conventional dialysis and remarkably reduces the solvent consumption.  相似文献   

6.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of chloramphenicol (CAP) and thiamphenicol (THA) in honey. In this extraction method, 1.0 mL of acetonitrile (as dispersive solvent) containing 30 μL 1,1,2,2-tetrachloroethane (as extraction solution) was rapidly injected by syringe into a 5.00-mL water sample containing the analytes, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2000 μg kg−1 for target analytes. The enrichment factors for CAP and THA were 68.2 and 87.9, and the limits of detection (S/N = 3) were 0.6 and 0.1 μg kg−1, respectively. The relative standard deviations (RSDs) for the extraction of 10 μg kg−1 of CAP and THA were 4.3% and 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microliter level. Honey samples were successfully analyzed using the proposed method.  相似文献   

7.
A novel method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. A mixture of extraction solvent (41 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) were rapidly injected into 5.0 mL aqueous sample for the formation of cloudy solution, the analytes in the sample were extracted into the fine droplets of CCl4. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 5 to 5000 ng mL−1 for target analytes. The enrichment factors for DMP, DEP and DnBP were 45, 92 and 196, respectively, and the limits of detection were 1.8, 0.88 and 0.64 ng mL−1, respectively. The relative standard deviations (R.S.D.) for the extraction of 10 ng mL−1 of phthalate esters were in the range of 4.3-5.9% (n = 7). Lake water, tap water and bottled mineral water samples were successfully analyzed using the proposed method.  相似文献   

8.
A rapid and effective preconcentration method for extraction of rhodamine 6G was developed by using a dispersive liquid-liquid microextraction (DLLME) prior to UV-vis spectrophotometry. In this extraction method, a suitable mixture of acetone (disperser solvent) and chloroform (extractant solvent) was injected rapidly into a conical test tube containing aqueous solution of rhodamine 6G. Therefore, a cloudy solution was formed. After centrifugation of the cloudy solution, sedimented phase was evaporated, reconstituted with methanol and measured by UV-vis spectrophotometry. Different operating variables such as type and volume of extractant solvent, type and volume of disperser solvent, pH of the sample solution, salt concentration and extraction time were investigated. The optimized conditions (extractant solvent: 300 μL of chloroform, disperser solvent: 3 mL of acetone, pH: 8 and without salt addition) resulted in a linear calibration graph in the range of 5-900 ng mL−1 of rhodamine 6G in initial solution with R2 = 0.9988 (n = 5). The Limits of detection and quantification were 2.39 and 7.97 ng mL−1, respectively. The relative standard deviation for 50 and 250 ng mL−1 of rhodamine 6G in water were 2.88% and 1.47% (n = 5), respectively. Finally, the DLLME method was applied for determination of rhodamine 6G in different industrial waste waters.  相似文献   

9.
A fast, sensitive and selective procedure employing a combination of microwave-assisted extraction (MAE) and solid phase extraction (SPE) was applied prior to liquid chromatographic identification and quantification of phenolic compounds in plant materials. MAE has been tested and optimized for the isolation of phenolic acids (gallic, protocatechuic, p-hydroxybenzoic, chlorogenic, vanilic, caffeic, syringic, p-coumaric, ferulic, sinapic, benzoic, m-coumaric, o-coumaric, rosmarinic, cinnamic acids) and 3,4-dihydroxybenzaldehyde, syringaldehyde, p-hydroxybenzaldehyde, and vanillin in various plants. The effects of experimental conditions on MAE efficiency, such as solvent composition, temperature, extraction time, have been studied. The extraction efficiencies were compared with those obtained by computer-controlled, two-step Soxhlet-like extractions. Plant extracts were purified and phenolic compounds were pre-concentrated using SPE on polymeric RP-105 SPE sorbent prior to HPLC analysis. Chromatographic separation was carried out on a Hypersil BDS C18 column using a mobile phase consisted of 0.3% (v/v) acetic acid in water (solvent A) and methanol (solvent B) at flow rate 0.6 ml min−1 and column temperature 30 °C with gradient elution.  相似文献   

10.
Ultrasonic solvent extraction of organochlorine pesticides from soil   总被引:1,自引:0,他引:1  
Ultrasonic solvent extraction of the organochlorine pesticides (OCP) including α-, β-, γ- and Δ-hexachlorocyclohexane (HCH), heptachlor, aldrin, o,p′-DDE, dieldrin, p,p′-DDE, p,p′-DDT, methoxychlor, mirex from soil is reported. The extraction procedure was optimized with regard to the solvent type, amount of solvent, duration of sonication and number of extraction steps. Determination of pesticides was carried out by gas chromatography (GC) equipped with electron capture detection (ECD). Twice ultrasonic extraction using 25 mL of a mixture of petroleum ether and acetone (1/1 v/v) for 20 min of sonication showed satisfactory extraction efficiency. Recoveries of pesticides from fortified soil samples are over 88% for three different fortification levels between 15 and 200 μg kg−1, and relative standard deviations of the recoveries are generally below 6%. Real soil samples were analyzed for OCP residues by optimized ultrasonic solvent extraction and shake-flask as well as soxhlet extraction technique. Investigated all extraction methods showed comparable extraction efficiencies. Optimized ultrasonic solvent extraction is the most rapid procedure because the use of time in ultrasonic extraction was considerably reduced compared to shake-flask and soxhlet extraction.  相似文献   

11.
In this work, for the first time, capillary zone electrophoresis (CZE) technique combined with microwave-assisted extraction (MAE) was developed for the fast quantification of chlorogenic acid (CA) in tobacco residues. CA in tobacco residue samples were extracted by MAE technique, and then analyzed by CZE. As a new sample preparation method for tobacco residues, the MAE procedure is optimized, validated and compared with conventional methods including ultrasonic extraction (USE) and reflux extraction (RE). It is found that MAE gives the best result due to the highest extraction efficiency within shortest extraction time (only 4.0 min). Here, CA is determined by CZE based on the calibration curve of its authentic standard. The method linearity, detection limit, precision and recovery are studied. The results show that the combined MAE and CZE method has a linearity (R2 0.991, 0.003-0.5 mg ml−1), a limit of detection (0.003 mg ml−1), a limit of quantification (0.01 mg ml−1), good precision (R.S.D. = 4.28%) and a finer recovery (89.0%). The proposed method was successfully applied to the analysis of CA in tobacco residue samples. The experiment results have demonstrated that the CZE combined with MAE is a convenient, fast, economical and reliable method for the determination of CA in tobacco residues.  相似文献   

12.
A low temperature microwave-assisted extraction method (MAE) is reported for the analysis of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter (PM). The main parameters affecting the extraction efficiency (choice of extractants, microwave power, and extraction time) were investigated and optimized. The optimized procedure requires a 20 ml mixture of acetone:n-hexane (1:1) for extraction of PAHs in PM at 150 W of microwave energy (20 min extraction time). Clean-up of MAE extracts was not found to be necessary. The optimized method was validated using two different SRM (1648-urban particulate matter and 1649a, urban dust). The results obtained are in good agreement with certified values. PAHs recoveries for both reference materials were between 79 and 122% with relative standard deviation ranging from 3 to 21%. Detection limits were determined based on blank determination using two kinds of quartz filter substrates (n = 10), which ranged from 0.001 (0.03) ng m−3 (pg/μg) for B(k)Ft to 1.119 (37.3) for Naph in ng m−3 (pg/μg), respectively. The repeatability and day-to-day reproducibility obtained in this study were in the range of 4-16 and 3-25% for spiked standards and SRM 1649, respectively. The optimized and validated MAE technique was applied to the extraction of PAHs from a set of real world PM samples collected in Singapore. The sum of particulate-bound PAHs in outdoor PM ranged from 1.05 to 3.45 ng m−3 while that in indoor PM (cooking emissions) ranged from 27.6 to 75.7 ng m−3, respectively.  相似文献   

13.
Homogeneous liquid-liquid extraction method was studied based on a phase separation phenomenon in a ternary solvent system. According to this procedure, mononitrotoloenes were extracted by single-phase extraction in a water/methanol/chloroform, homogeneous ternary solvent system. Methanol and chloroform were used as consolute and extraction solvents, respectively. The homogeneous solution was broken by the addition of salt and a cloudy solution was formed. After centrifugation, the fine droplets of the extraction solvent were sedimented in the bottom of the conical test tube. Analysis of the extracts was carried out by gas chromatography. The optimization procedure was performed using Box-Behnken design. The variables involved were: sample and extraction solvent volumes, consolute solvent volume and phase separator reagent concentration. Optimum results were obtained under the following conditions: sample volume of 5 mL, extraction solvent volume of 55 μL, consolute solvent volume of 1 mL and phase separator reagent concentration; 5% (w/v). Under these conditions, the enrichment factors of 354, 311 and 300, dynamic linear ranges of 0.5-500, 1-500 and 1-500 μg L−1, and limit of detections (LODs) of 0.09, 0.09 and 0.1 μg L−1 were obtained for o-nitrotoluene, m-nitrotoluene and p-nitrotoluene, respectively. Finally, the method was successfully applied to the extraction and determination of MNTs in the waste water samples in the range of micrograms per liter with R.S.Ds. < 13.2%.  相似文献   

14.
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detector (GC-FID) was developed for preconcentration and determination of some nitroaromatic compounds in wastewater samples. The effects of different variables on the extraction efficiency were studied simultaneously using experimental design. The variables of interest in the DLLME process were extraction and disperser solvent volumes, salt effect, sample volume, extraction temperature and extraction time. A Plackett-Burman design was performed for screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a central composite design (CCD) and the response surface equations were derived. The optimum experimental conditions found from this statistical evaluation included: sample volume, 9 mL; extraction solvent (CCl4) volume, 20 μL; disperser solvent (methanol) volume, 0.75 mL; sodium chloride concentration, 3% (w/v); extraction temperature, 20 °C and extraction time, 2 min. Under the optimum conditions, the preconcentration factors were between 202 and 314. Limit of detections (LODs) ranged from 0.09 μg L−1 (for 2-nitrotoluene) to 0.5 μg L−1 (for 2,4-dinitrotoluene). Linear dynamic ranges (LDRs) of 0.5-300 and 1-400 μg L−1 were obtained for mononitrotoluenes (MNTs) and dinitrotoluenes (DNTs), respectively. Performance of the present method was evaluated for extraction and determination of nitroaromatic compounds in wastewater samples in the range of microgram per liter and satisfactory results were obtained (RSDs < 10.1%).  相似文献   

15.
Chen L  Ding L  Yu A  Yang R  Wang X  Li J  Jin H  Zhang H 《Analytica chimica acta》2007,596(1):164-170
This paper describes a new method for the determination of total flavonoids in Platycladus orientalis (L.) Franco. The method was based on dynamic microwave-assisted extraction (DMAE) coupled with on-line derivatization and ultraviolet-visible (UV-vis) detection. The influence of the experimental conditions was tested. Maximum extraction yield was achieved using 80% aqueous methanol of extraction solvent; 80 W of microwave output power; 5 min of extraction time; 1.0 mL min−1 of extraction solvent flow rate. The derivatization reaction between aluminium chloride and flavonoid is one of the most sensitive and selective reactions for total flavonoids determination. The optimized derivatization conditions are as follows: derivatization reagent 1.5% aluminium chloride methanol solution; reaction coil length 100 cm; derivatization reagent flow rate 1.5 mL min−1. The detection and quantification limits obtained are 0.28 and 0.92 mg g−1, respectively. The intra-day and inter-day precisions (R.S.D.) obtained are 1.5% and 4.6%, respectively. Mean recovery is 98.5%. This method was successfully applied to the determination of total flavonoids in P. orientalis (L.) Franco and compared with heat reflux extraction. The results showed that the higher extraction yield of total flavonoids was obtained by DMAE with shorter extraction time (5 min) and small quantity of extraction solvent (5 mL).  相似文献   

16.
Wenyan Ma  Ruilin Hu  Zizhang Zhang 《Talanta》2010,80(3):1292-113
The application of ionic liquids based microwave-assisted extraction (ILMAE) was successfully developed for extracting three alkaloids N-nornuciferine, O-nornuciferine, and nuciferine from lotus leaf. Seven kinds of 1-alkyl-3-methylimidazolium with different cations and anions were investigated in this work and 1.0 M 1-hexyl-3-methylimidazolium bromide ([C6MIM]Br) solution was selected as solvent. In addition, the microwave parameters including irradiation power, extraction time and solid-liquid ratio were optimized. Compared with the regular MAE and conventional heat-reflux extraction (HRE), the proposed approach exhibited higher efficiency (0.9-43.7% enhanced) and shorter extraction time (from 2 h to 2 min), which indicated ILMAE was an efficient, rapid and simple sample preparation technique. Moreover, the proposed method was validated by the linearity, reproducibility, and recovery experiments. Good linearity was observed with the regression coefficients (r2) between 0.9998 and 0.9999. The recoveries of all methods were in the range of 94.6% and 105.5% with RSD lower than 6.6%, which indicated that the proposed method was credible.  相似文献   

17.
Zhu X  Su Q  Cai J  Yang J 《Analytica chimica acta》2006,579(1):88-94
In the present study, a new method using microwave-assisted solvent extraction (MASE) technique followed directly GC analysis was developed for the extraction of volatile organic acids (VOAs) in tobacco. The MASE conditions (heating time, volume of extracting solvent and extraction temperature) were optimized by means of an orthogonal array design (OAD) procedure. The results suggested that extractant, temperature and heating time were statistically the most significant factors. The extracts were directly analyzed with capillary GC operating in splitless-injection mode on an Agilent HP-FFAP capillary column. Under optimum operating conditions, MASE showed significantly better recoveries than those obtained by the conventional extraction method (ultrasonic and reflux extraction), ranging from 90.6% to 103.2%. In addition, a drastic reduction of the extraction time (20 min versus 4 h) and solvent consumption (20 mL versus 100 mL) was achieved with an outstanding reproducibility (CV ≤5%).  相似文献   

18.
A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0 mg of graphene as sorbent into a 100 μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2–4000 pg mL−1 with correlation coefficients (r2) ≥ 0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD) ≤ 6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10 mL) at a small amount of sorbent (1 mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.  相似文献   

19.
Microwave-assisted extraction (MAE) of nonylphenols (NP), nonylphenol mono- and diethoxylates (NP1EO and NP2EO, respectively) and phthalate esters was optimised using an experimental design approach. A D-optimal mixture design was used to optimise the pressure inside the extraction vessel (110-207 kPa), the extraction time (5-25 min) and the extraction solvent (methanol, acetone or n-hexane) or the solvent mixture for the microwave-assisted extraction. Percentage of microwave power (80%) and solvent volume (15 ml) were fixed in all the experiments. As a consequence, the optimum extraction of these compounds was carried out at an intermediate pressure (159 kPa) with pure methanol and during 15 min. Moreover, solid phase extraction was also optimised for the clean-up of the extracts and C-18, LiChrolut® and Oasis® cartridges were studied in order to obtain the best recoveries of the compounds of interest. The highest recoveries were obtained with LiChrolut® cartridges after the elution with ethyl acetate. The cleaned extracts were analysed in a gas chromatograph with mass spectrometric detection and in a liquid chromatograph with diode array and fluorescence detection (HPLC-DAD-UV-FLD). The same sediment was also extracted twice in order to check that an exhaustive extraction of the analytes had occurred. Finally, the optimised extraction method was compared with pressurised solvent extraction (PSE), using an estuarine sediment sample.  相似文献   

20.
Li Y  Wei G  Hu J  Liu X  Zhao X  Wang X 《Analytica chimica acta》2008,615(1):96-103
A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 μL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5 s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL−1 for BDE-28 and BDE-99, and 0.1-100 ng mL−1 for BDE-47 and BDE-209, respectively. Coefficients of correlation (r2) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL−1 for BDE-28 and BDE-99, and 100 ng mL−1 for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n = 5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL−1 (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL−1 were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号