首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A method based on MCE coupled with chemiluminescence (CL) detection was developed for the determination of taurine (Tau) and amino acids including alanine (Ala), glycine (Gly), tryptophan (Trp), glutamic acid (Glu) and aspartic acid (Asp) present in mice single fibrosarcoma (S180) cells. Cell injection, loading, cytolysis, electrophoretic separation and CL detection were integrated onto a simple double‐T microfluidic chip. The intracellular constituents were electrophoretically separated within 150 s. The CL detection was based on the enhancement effects of Tau and amino acids on the CL reaction of luminol with H2O2 and Cu2+. The average amounts of Tau, Trp, Gly, Ala, Glu and Asp in per S180 cell from a cell population were 4.73, 1.23, 2.65, 1.94, 1.61 and 1.99 fmol. Ten S180 cells were analyzed, and the contents of Tau, Trp, Gly, Ala, Glu and Asp in mice single S180 cells were found to be in the range of 1.78–8.84, 0.95–2.31, 1.08–6.87, 1.03–4.05, 0.84–2.61 and 0.82–3.68 fmol, respectively. This work demonstrates that MCE coupled with CL detection is a useful analytical tool that is simple, quick and highly sensitive for single‐cell analysis.  相似文献   

2.
An analytical method based on microchip electrophoresis (MCE) and chemiluminescence detection (CL) was developed for the determination of intracellular sulphydryl compounds. Cell injection/loading, cytolysis, electrophoretic separation, and CL detection were integrated onto a simple cross-microfluidic chip. Selective CL detection of sulphydryl compounds was achieved by deploying the luminol–Na2S2O8 reaction. Under the CL conditions selected, many endogenous compounds in biological systems such as amino acids, biogenic amines, peptides and proteins did not produce any CL signal, which further ensured a high selectivity of the proposed MCE–CL assays. Sulphydryl compounds including cysteine (Cys), glutathione (GSH), and hemoglobin (Hb) were selected as the test compounds. The MCE separation was completed within 120 s. The detection limits were estimated to be 7 amol for Cys, 32 amol for GSH and 69 amol for Hb, respectively. The present method was applied to analyze individual red blood cells collected from both healthy subjects and cancer patients. It was found that the average intracellular contents of Cys, GSH and Hb were in the ranges of 26–43 amol/cell, 128–323 amol/cell and 522–667 amol/cell, respectively for cancer patients, compared to 579–609 amol Hb/cell and not detectable Cys and GSH for healthy subjects.  相似文献   

3.
Under conditions when amino acids were effectively neutral and the membrane was near its point of zero charge, crossflow nanofiltration experiments revealed an extended duration before steady-state permeate concentrations were attained for tryptophan and phenylalanine compared with glycine and alanine. Valine showed an intermediate behavior compared with Trp and Phe on one hand and Gly and Ala on the other. Additionally, steady-state rejections of Trp and Phe were lower than that expected from predominantly steric and electrostatic considerations (Gly, Ala, and Val), consistent with enhanced diffusion across the active layer of the membrane due to partitioning onto the polymeric matrix (polymer phase diffusion plus pore diffusion). Batch tests substantiated the unsteady-state removals during crossflow nanofiltration by revealing significant uptake of Phe and Trp, limited uptake of Val, and no measurable uptake of Gly and Ala on the polymeric membrane. Hence, sorption can lead to the overestimation of Trp and Phe, (and possibly Val) rejection capabilities of nanofiltration membranes in the short-term. In other words, even sorption of solutes with low octanol–water partition coefficients (log Kow < 0) such as Trp and Phe requires more careful long-term measurements since it substantially increases the time to achieve steady-state conditions.  相似文献   

4.
Amino acids Trp, Gly, Ala, Leu are extracted efficiently from aqueous solution at pH 1.5–4.0 (Lys and Arg at pH 1.5–5.5) into the room temperature ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BmimPF6) with dicyclohexano-18-crown-6 (CE). The most hydrophilic amino acids such as Gly are extracted as efficiently as the less hydrophilic (92–96%). The influence of pH, amino acid and crown ether concentration, volume ratio of aqueous and organic phases, and presence of some cations on amino acid recovery were studied. The ratio of amino acid to crown ether in the extracted species is 1:1 for cationic Trp, Leu, Ala, and Gly and to 1:2 for dicationic Arg and Lys. This ionic liquid extraction system was used successfully for the recovery of amino acids from pharmaceutical samples and fermentation broth, and was followed by fluorimetric determination.These results were published in part in Smirnova SV (2002) Ph.D. Thesis, Moscow State University.  相似文献   

5.
Su R  Lin JM  Uchiyama K  Yamada M 《Talanta》2004,64(4):1024-1029
A glass electrophoresis microchip integrated a flow-type chemiluminescence (CL) detection cell has been developed and evaluated. The chip pattern is a double-T-type electrophoretic sample injection and separation combining with a Y-type chemiluminecent detector. The double-T geometry allows for high-efficiency sample injection and geometric definition of sample plug size. The branch of Y was used as CL reagent channel, and the CL reagent was delivered by a lab-made micropump. Bis[(2,4,6-trichlorophenyl)]oxalate-H2O2 CL system was employed to detect dansyl amino acids. On this microchip, dansyl-phenylalanine and -sarcosine were successfully separated by electrophoresis and detected within 250 s. The detection limits (S/N=3) of dansyl-phenylalanine and -sarcosine could reach to 2.8 and 3.2 μM, respectively, due to the vigorous dilution of sample with CL reagent and timely removal of the waste solution from reaction area.  相似文献   

6.
The concept of sequential injection chromatography (SIC) was exploited to automate the fluorimetric determination of amino acids after pre-column derivatization with o-phthaldialdehyde (OPA) in presence of 2-mercaptoethanol (2MCE) using a reverse phase monolithic C18 stationary phase. The method is low-priced and based on five steps of isocratic elutions. The first step employs the mixture methanol: tetrahydrofuran: 10 mmol L−1 phosphate buffer (pH 7.2) at the volumetric ratio of 8:1:91; the other steps use methanol: 10 mmol L−1 phosphate buffer (pH 7.2) at volumetric ratios of 20:80, 35:65, 50:50 and 65:35. At a flow rate of 10 μL s−1 a 25 mm long-column was able to separate aspartic acid (Asp), glutamic acid (Glu), asparagine (Asn), serine (Ser), glutamine (Gln), glycine (Gly), threonine (Thr), citruline (Ctr), arginine (Arg), alanine (Ala), tyrosine (Tyr), phenylalanine (Phe), ornithine (Orn) and lysine (Lys) with resolution >1.2 as well as methionine (Met) and valine (Val) with resolution of 0.6. Under these conditions isoleucine (Ile) and leucine (Leu) co-eluted. The entire cycle of amino acids derivatization, chromatographic separation and column conditioning at the end of separation lasted 25 min. At a flow rate of 40 μL s−1 such time was reduced to 10 min at the cost of resolution worsening for the pairs Ctr/Arg and Orn/Lys. The detection limits varied from 0.092 μmol L−1 for Tyr to 0.51 μmol L−1 for Orn. The method was successfully applied to the determination of intracellular free amino acids in the green alga Tetraselmis gracilis during a period of seven days of cultivation. Samples spiked with known amounts of amino acids resulted in recoveries between 94 and 112%.  相似文献   

7.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

8.
A highly sensitive microchip electrophoresis (MCE) method with chemiluminescence (CL) detection was developed for the determination of biogenic amines including agmatine (Agm), epinephrine (E), dopamine (DA), tyramine, and histamine in human urine samples. To achieve a high assay sensitivity, the targeted analytes were pre-column labeled by a CL tagging reagent, N-(4-aminobutyl)-N-ethylisoluminol (ABEI). ABEI-tagged biogenic amines after MCE separation reacted with hydrogen peroxide in the presence of horseradish peroxidase (HRP), producing CL emission. Since no CL reagent was added to the running buffer, the background of the CL detection was extremely low, resulting in a significant improvement in detection sensitivity. Detection limits (S/N = 3) were in the range from 5.9 × 10−8 to 7.7 × 10−8 M for the biogenic amines tested, which were at least 10 times lower than those of the MCE–CL methods previously reported. Separation of a urine sample on a 7 cm glass/poly(dimethylsiloxane) (PDMS) microchip channel was completed within 3 min. Analysis of human urine samples found that the levels of Agm, E and DA were in the ranges of 2.61 × 10−7 to 4.30 × 10−7 M, 0.81 × 10−7 to 1.12 × 10−7 M, and 8.76 × 10−7 to 11.21 × 10−7 M (n = 4), respectively.  相似文献   

9.
Reaction of formaldehyde with amino acids followed by oxidation with hydrogen peroxide to produce a fluorophore Norharman product is well known and was used for the spectrofluorimetric determination of l-tryptophan (Trp). This study aimed to use graphene oxide (GO) to enhance the selectivity and sensitivity of Trp in presence of other amino acids and possible interfering compounds. Different parameters such as pH, temperature, incubation time, and concentrations of formaldehyde, H2O2 and GO were studied to optimize the condition of determination. Experimental data showed that the maximum fluorescence intensity was achieved in pH 7.0–9.0 phosphate buffer mixed with 7–10% (v/v) formaldehyde and 1–2% (v/v) H2O2 as oxidizing agent at 60 ?C for 1 h. On the basis of calibration curve of various concentrations of Trp in the presence of 20 μg mL−1 GO, the lower limit of detection (LOD) of Trp was determined as 0.092 nmol mL−1 and the lower limit of quantification (LOQ) was 0.3 nmol mL−1. The selectivity of Trp in presence of other amino acids and possible interfering compounds were studied with and without GO. The data obtained after inner filter effect corrections revealed that the selectivity of Trp in presence of amino acids and other possible interfering agents was improved in the range of 76–96%, compared with that in absence of GO. The enhancement of selectivity in the presence of GO indicates that the Trp and other amino acid and possible interfering compounds were adsorbed by GO, and the selective uptaking of Trp-by the reaction with formaldehyde followed by oxidation with H2O2 at 60 ?C with high selectivity and sensitivity was achieved successfully.  相似文献   

10.
KIA7, a peptide with a highly restricted set of amino acids (Lys, Ile, Ala, Gly and Tyr), adopts a specifically folded structure. Some amino acids, including Lys, Ile, Ala, Gly and His, form under the same putative prebiotic conditions, whereas different conditions are needed for producing Tyr, Phe and Trp. Herein, we report the 3D structure and conformational stability of the peptide KIA7H, which is composed of only Lys, Ile, Ala, Gly and His. When the imidazole group is neutral, this 20‐mer peptide adopts a four‐helix bundle with a specifically packed hydrophobic core. Therefore, one‐pot prebiotic proteins with well‐defined structures might have arisen early in chemical evolution. The Trp variant, KIA7W, was also studied. It adopts a 3D structure similar to that of KIA7H and its previously studied Tyr and Phe variants, but is remarkably more stable. When tested for ribonucleolytic activity, KIA7H, KIA7W and even short, unstructured peptides rich in His and Lys, in combination with Mg++, Mn++ or Ni++ (but not Cu++, Zn++ or EDTA) specifically cleave the single‐stranded region in an RNA stem–loop. This suggests that prebiotic peptide–divalent cation complexes with ribonucleolytic activity might have co‐inhabited the RNA world.  相似文献   

11.
In the present work, a tube-like structure of graphene hybrid as modifier to fabricate electrode for simultaneous detection of ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp) was reported. The hybrid was synthesized by a simple method based on graphene sheets (GS) and 3,4,9,10-perylenetetracarboxylic acid (PTCA) via π–π stacking interaction under ultrasonic condition. The combination of GS and PTCA could effectively improve the dispersion of GS, owing to PTCA with the carboxylic-functionalized interface. Comparing with pure GS or PTCA modified electrode, GS–PTCA displayed high catalytic activity and selectivity toward the oxidation of AA, DA, UA, and Trp. Moreover, cyclic voltammetry, different pulse voltammetry and scanning electron microscopy were employed to characterize the sensors. The experiment results showed that the linear response range for simultaneous detection of AA, DA, UA, and Trp were 20–420 μM, 0.40–374 μM, 4–544 μM and 0.40–138 μM, respectively, and the detection limits were 5.60 μM, 0.13 μM, 0.92 μM and 0.06 μM (S/N = 3). Importantly, the proposed method offers promise for simple, rapid, selective and cost-effective analysis of small biomolecules.  相似文献   

12.
A novel electrode was developed through electrodepositing gold nanoparticles (GNPs) on overoxidized-polyimidazole (PImox) film modified glassy carbon electrode (GCE). The combination of GNPs and the PImox film endowed the GNPs/PImox/GCE with good biological compatibility, high selectivity and sensitivity and excellent electrochemical catalytic activities towards ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). In the fourfold co-existence system, the peak separations between AA–DA, DA–UA and UA–Trp were large up to 186, 165 and 285 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 210.0–1010.0 μM, 5.0–268.0 μM and 6.0–486.0 μM with detection limits (S/N = 3) of 2.0 μM, 0.08 μM and 0.5 μM, respectively. Two linear calibrations for Trp were obtained over ranges of 3.0–34.0 μM and 84.0–464.0 μM with detection limit (S/N = 3) of 0.7 μM. In addition, the modified electrode was applied to detect AA, DA, UA and Trp in samples using standard addition method with satisfactory results.  相似文献   

13.
Amino acids in individual human lymphocytes were determined by capillary zone electrophoresis with electrochemical detection (ED) at a carbon fiber bundle electrode after on-column derivatization with naphthalene-2,3-dicarboxaldehyde (NDA) and CN. In order to inject cells easily, a cell injector was designed. In this method, a single human lymphocyte and then the lysing/derivatizing buffer were electrokinetically injected into the front end of the separation capillary as a chamber to lyse the lymphocyte and derivatize amino acids in the cell. Four amino acids (serine (Ser), alanine (Ala), taurine (Tau), and glycine (Gly)) in single human lymphocytes have been identified. Quantitation has been accomplished through the use of calibration curves.  相似文献   

14.
A rapid and simple method using capillary electrophoresis (CE) with chemiluminescence (CL) detection was developed for the determination of levodopa. This method was based on enhance effect of levodopa on the CL reaction between luminol and potassium hexacyanoferrate(III) (K3[Fe(CN)6]) in alkaline aqueous solution. CL detection employed a lab-built reaction flow cell and a photon counter. The optimized conditions for the CL detection were 1.0 × 10−5 M luminol added to the CE running buffer and 5.0 × 10−5 M K3[Fe(CN)6] in 0.6 M NaOH solution introduced postcolumn. Under the optimal conditions, a linear range from 5.0 × 10−8 to 2.5 × 10−6 M (r = 9991), and a detection limit of 2.0 × 10−8 M (signal/noise = 3) for levodopa were achieved. The precision (R.S.D.) on peak area (at 5.0 × 10−7 M of levodopa, n = 11) was 4.1%. The applicability of the method for the analysis of pharmaceutical and human plasma samples was examined.  相似文献   

15.
A novel in-capillary reduction and capillary electrophoretic (CE)-chemiluminescence (CL) method was developed for the sensitive and selective determination of chromium(III) and chromium(VI). The proposed method was based on the in-capillary reduction of Cr(VI) with acidic H2O2 to form Cr(III) using the zone-passing technique and chemiluminescence detection of Cr(III). The sample [Cr3+ and CrO42−], hydrochloric acid, and H2O2 (reductant) solution segments were injected for specified periods of time in this order from the anodic end of a capillary, followed by application of an appropriate running voltage between both ends. As both chromium species have opposite charges, Cr3+ migrates to the cathode while CrO42− ion, moving oppositely to the anode, reacts with acidic H2O2, resulted in formation of Cr3+. Based on the migration time difference of both Cr3+ ions, they were separated by zone electrophoresis. Running buffer was composed of 0.02 mol l−1 HAc-NaAc (pH 4.7) with 1×10−3 mol l−1 EDTA. Parameters affecting CE-CL separation and detection, such as reductant concentration, mixing mode of the analytes with CL reagent, CL reaction reagent pH and concentration, stability of luminol-hydrogen peroxide mixed solution were optimized. The limits of detection for chromium(III) and chromium(VI) (3σ) were 6×10−13 mol l−1 (mass concentration 12 zmol) and 8×10−12 mol l−1 (160 zmol), respectively. This method offered potential advantages of simplicity, sensitivity, selectivity and applicability to the determination of Cr(III) and Cr(VI) in environmental water.  相似文献   

16.
The decomposition of 59 different cluster ions (generated by fast atom bombardment) consisting of two different amino acids and a sodium ion was analysed. The only fragment ions of significant abundance could be assigned to sodium ion-bound amino acids. Assuming that the most abundant ion in the fragment ion spectrum corresponds to the amino acid with the highest sodium ion affinity (SIA), the 20 common α-amino acids could be ordered with increasing sodium ion affinity as follows: Gly, Ala, Cys, Val, (Leu, Ile), Ser, Met, Thr, (Phe, Pro), Asp, Tyr, (Glu, Lys), Trp, Asn, Gln, His, Arg. Quantitative determinations were carried out by comparison of the lithium ion affinity (LIA) of Ala with that of dimethylformamide (DMF) in a fragment ion scan of the ion-bound dimer Ala—Li+—DMF. LIA(Ala) was calculated from LIA(Ala) = LIA(DMF) – (1/C)ln[I(AlaLi+)/I(DMF—Li+)], where the constant C was estimated from measurements of proton-bound amine–amino acid clusters. From fragment ion analysis of nine other Li+-bound α-amino acid dimers, the following lithium ion affinities were obtained: Gly 51.0, Ala 52.6, Sar 53.5, α-aminobutyric acid 53.7, glycine methyl ester 54.7 and Val 54.8. SIA(Ala) was estimated to be 75% of the lithium ion affinity and from fragment ion analysis of ten Na+-bound α-amino acid dimers the following sodium ion affinities were obtained: Gly 37.9, Ala 39.4, α-aminobutyric acid 40.3, Val 41.0, glycine methylster 41.0 and Sar 41.2.  相似文献   

17.
Young-Teck Kim  Ji Hoon Lee 《Talanta》2009,78(3):998-1507
Based on the principle of liquid core waveguide, a novel microfluidic device with micro-scale detection window capable of sensing flashlight emitted from rapid 1,1′-oxalyldi-4-methylimidazole (OD4MI) chemiluminescence (CL) reaction was fabricated. Light emitted from OD4MI CL reaction occurring in the micro-dimensional pentagonal detection window (length of each line segment: 900.0 μm, depth: 50.0 μm) of the microfluidic device with two inlets and one outlet was so bright that it was possible to take an image every 1/30 s at the optimal focusing distance (60 cm) using a commercial digital camera. Peaks obtained using a flow injection analysis (FIA) system with the micro-scale detection window and OD4MI CL detection show excellent resolution and reproducibility without any band-broadening observed in analytical devices having additional reaction channel(s) to measure light generated from slow CL reaction. Maximum height (Hmax) and area (A) of peak, reproducibility and sensitivity observed in the FIA system with the microfluidic device and OD4MI CL detection depends on (1) the mole ratio between bis(2,4,6-trichlorophenyl) oxalate and 4-methyl imidazole yielding OD4MI, (2) the flow rate to mix OD4MI, H2O2 and 1-AP in the detection window of the microfluidic device, and (3) H2O2 concentration. We obtained linear calibration curves with wide dynamic ranges using Hmax and A. The detection limit of 1-AP determined with Hmax and A was as low as 0.05 fmole/injection (signal/background = 3.0).  相似文献   

18.
Islam MS  Kang SH 《Talanta》2011,84(3):752-758
A novel, quantitative analytical method for measuring C-reactive protein (CRP) levels in human serum has been developed based on the catalytic activity of gold nanoparticles (GNPs) and luminol-H2O2 chemiluminescence (CL). The CL intensity in the presence of CRP and its ligand, O-phosphorylethanolamine (PEA), was greatly enhanced due to the aggregation of GNPs after the addition of 0.5 M NaCl. Any pretreatment steps, such as covalent functionalization of GNPs, addition of antibodies, or labeling of CRP, were not needed for CL detection. The CL enhancement was linearly proportional to CRP concentration in the range of 1.88 fM to 1.925 pM. The detection limit of CRP in serum samples was estimated to be as low as 1.88 fM. The detection sensitivity was increased more than 164 times of magnitude over that of the conventional, enzyme-linked immunosorbent assay (ELISA) method. This proposed GNP-based CL detection method offers the advantages of simplicity, rapidity, and sensitivity.  相似文献   

19.
Songmei Hou  Hongbo He  Hongtu Xie 《Talanta》2009,80(2):440-384
Determination of amino acids by mass spectrometry (MS) is an important technique to investigate soil nitrogen transformation and cycling as amino acids being the major nitrogen-containing compounds in soil organic matter. However, researchers have long faced a critical problem in coupling an efficient separation technique to a sensitive MS detection system simultaneously. In this context, we established a new method of liquid chromatography coupled to mass spectrometry based on the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) derivatization method for convenient and accurate quantification of amino acids in soil samples. Baseline separation of 17 amino acid AQC-derivatives was achieved on an XTerraR MS C18 column using ammonium formate as a mobile phase modifier. The concentration of ammonium formate and the pH of the mobile phase were optimized in order to obtain sensitive MS signals. The response curves were linear over the range of 50-800 μmol L−1 amino acids. The detection limits were 0.20-0.60 pmol μL−1 on column and 0.07-0.24 μg g−1 soil under the optimized conditions. The method has been applied successfully for the first time to determine amino acids in 4 types of soil samples, in which 15 amino acids were quantified by MS detector but methionine and cystine were below the detection limits. Both the recovery and the precision were satisfactory. Hence, this proposed technique shows a potential for the identification of amino acids in soil as well as tracing the transformation of soil amino acids with isotope dilution technique in nitrogen cycling investigation.  相似文献   

20.
The enthalpies of dissolution of glycine (Gly) and L-α-alanine (Ala) in water at 288.15–318.15 K were measured. The results were compared with the earlier obtained data for L-α-phenylalanine (Phe) and L-α-histidine (His). The standard enthalpies of dissolution (Δsoln H 0) and differences (ΔC p 0 ) between the limiting partial molar heat capacity of the amino acids in solution and the heat capacity of the amino acids in the crystalline state were calculated in the temperature interval 273–373 K. Changes in the entropy of dissolution (ΔΔsoln S 0) and reduced Gibbs energy [Δ (Δsoln G 0/T)] in the temperature interval from 273 to 373 K were determined from the known thermodynamic relationships. The ΔC p 0 value is negative for hydrophilic glycine and positive for other amino acids. The ΔΔsoln S 0 values increase with an increase in the hydrophobicity of the amino acids. The Δ(Δsoln G 0/T) values become more negative in the order Ala, Phe, Gly, His. Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 4, pp. 711–714, April, 2007.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号