共查询到20条相似文献,搜索用时 15 毫秒
1.
A new generation polymeric ionic liquid (PIL), poly(1-4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (poly(VBHDIm+ NTf2−)), was synthesized and is shown to exhibit impressive selectivity towards the extraction of 12 polycyclic aromatic hydrocarbons (PAHs) from aqueous samples when used as a sorbent coating in direct-immersion solid-phase microextraction (SPME) coupled to gas chromatography (GC). The PIL was imparted with aromatic character to enhance π–π interactions between the analytes and the sorbent coating. For comparison purposes, a PIL with similar structure but lacking the π–π interaction capability, poly(1-vinyl-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide) (poly(HDIm+ NTf2−)), as well as a commercial polydimethylsiloxane (PDMS) sorbent coating were evaluated and exhibited much lower extraction efficiencies. Extraction parameters, including stir rate and extraction time, were studied and optimized. The detection limits of poly(VBHDIm+ NTf2−), poly(HDIm+ NTf2−), and PDMS coatings varied between 0.003–0.07 μg L−1, 0.02–0.6 μg L−1, and 0.1–6 μg L−1, respectively. The partition coefficients (log Kfs) of eight PAHs to the three studied fiber coatings were estimated using a static SPME approach. This study represents the first report of analyte partition coefficients to any PIL-based material. 相似文献
2.
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water). 相似文献
3.
A. Ishizaki K. Saito N. Hanioka S. Narimatsu H. Kataoka 《Journal of chromatography. A》2010,1217(35):5555-5563
A simple and sensitive automated method, consisting of in-tube solid-phase microextraction (SPME) coupled with high-performance liquid chromatography-fluorescence detection (HPLC-FLD), was developed for the determination of 15 polycyclic aromatic hydrocarbons (PAHs) in food samples. PAHs were separated within 15 min by HPLC using a Zorbax Eclipse PAH column with a water/acetonitrile gradient elution program as the mobile phase. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample using a CP-Sil 19CB capillary column as an extraction device. Low- and high-molecular weight PAHs were extracted effectively onto the capillary coating from 5% and 30% methanol solutions, respectively. The extracted PAHs were readily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME HPLC-FLD method, good linearity of the calibration curve (r > 0.9972) was obtained in the concentration range of 0.05–2.0 ng/mL, and the detection limits (S/N = 3) of PAHs were 0.32–4.63 pg/mL. The in-tube SPME method showed 18–47 fold higher sensitivity than the direct injection method. The intra-day and inter-day precision (relative standard deviations) for a 1 ng/mL PAH mixture were below 5.1% and 7.6% (n = 5), respectively. This method was applied successfully to the analysis of tea products and dried food samples without interference peaks, and the recoveries of PAHs spiked into the tea samples were >70%. Low-molecular weight PAHs such as naphthalene and pyrene were detected in many foods, and carcinogenic benzo[a]pyrene, at relatively high concentrations, was also detected in some black tea samples. This method was also utilized to assess the release of PAHs from tea leaves into the liquor. 相似文献
4.
A novel chemically bonded graphene oxide/fused-silica fiber was prepared and applied in solid-phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized in our work. Detection limits to the six polycyclic aromatic hydrocarbons were less than 0.08 μg/L, and their calibration curves were all linear (R(2)≥0.9954) in the range from 0.05 to 200 μg/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.13 and 15.87%, respectively. This novel fiber was then utilized to analyze two real water samples from the Yellow River and local waterworks, and the recoveries of samples spiked at 1 and 10 μg/L ranged from 84.48 to 118.24%. Compared with other coating materials, this graphene oxide-coated fiber showed many advantages: wide linear range, low detection limit, and good stability in acid, alkali, organic solutions and at high temperature. 相似文献
5.
Aguinaga N Campillo N Viñas P Hernández-Córdoba M 《Analytical and bioanalytical chemistry》2008,391(4):1419-1424
This paper describes a headspace solid-phase microextraction (HS-SPME) procedure coupled to gas chromatography with mass spectrometric
detection (GC–MS) for the determination of eight PAHs in aquatic species. The influence of various parameters on the PAH extraction
efficiency was carefully examined. At 75 °C and for an extraction time of 60 min, a polydimethylsiloxane–divinylbenzene (PDMS/DVB)
fiber coating was found to be most suitable. Under the optimized conditions, detection limits ranged from 8 to 450 pg g−1, depending on the compound and the sample matrix. The repeatability varied between 7 and 15% (RSD). Accuracy was tested using
the NIST SRM 1974b reference material. The method was successfully applied to different samples, and the studied PAHs were
detected in several of the samples.
Figure Headspace SPME sampling followed by GC–MS facilitates routine monitoring of PAHs in aquatic species 相似文献
6.
Headspace solvent microextraction and gas chromatographic determination of some polycyclic aromatic hydrocarbons in water samples 总被引:1,自引:0,他引:1
Headspace solvent microextraction (HSME) was shown to be an efficient preconcentration method for extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions. A microdrop of 1-butanol (as extracting solvent) containing biphenyl (as internal standard) was used in this investigation. Extraction occurred by suspending a 3 μl drop of 1-butanol from the tip of a microsyringe fixed above the surface of solution in a sealed vial. After extraction for a preset time, the microdrop was retracted back into the syringe and injected directly into a GC injection port. The effects of nature of extracting solvent, microdrop and sample temperatures, stirring rate, microdrop and sample volumes, ionic strength and extraction time on HSME efficiency were investigated and optimized. Finally, the enrichment factor, dynamic linear range (DLR), limit of detection (LOD) and precision of the method were evaluated by water samples spiked with PAHs. The optimized procedure was successfully applied to the extraction and determination of PAHs in different water samples. 相似文献
7.
Verónica Pino 《Analytica chimica acta》2003,477(1):81-91
A method for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments using microwave-assisted extraction with a micellar medium combined with solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been developed. Two kinds of SPME fibers (100 μm polydimethylsiloxane and 85 μm polyacrylate) and different micellar media were compared for the extraction efficiency of the 16 EPA priority PAHs. The polyacrylate fiber with a micellar medium of polyoxyethylene-10-laurylether provides the highest extraction efficiency. The method is remarkable for presenting lower equilibrium times and considerably higher reproducibilities than the obtained in aqueous medium. The LODs obtained ranged between 0.28 ng/ml for fluorene and 7.66 ng/ml for indeno[1,2,3-cd]pyrene. The method has been applied to the determination of PAHs in a certified marine sediment (SRM 1941a), obtaining recoveries between 58.6 and 111.5% for three- to five-ring PAHs with precision close to or lower than the certified values. 相似文献
8.
Wang Y Zhang W Dong Y Fan R Sheng G Fu J 《Analytical and bioanalytical chemistry》2005,383(5):804-809
A high-performance liquid chromatographic method with fluorescence detection has been developed to determine the urinary polycyclic
aromatic hydrocarbon metabolites 2-hydroxynaphthalene, 2-hydroxyfluorene, 9-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenz[a]pyrene.
Solid phase extraction (SPE) was used to clean up the samples, and washing with 30% methanol was found to be the best way
to remove interferences in the matrix. The method detection limits ranged from 0.044 μg/L for 1-hydroxypyrene to 1.615 μg/L
for 3-hydroxybenz[a]pyrene, and the recoveries ranged between 40% for 3-hydroxybenz[a]pyrene and 99% for 2-hydroxynaphthalene.
The within-day relative standard deviation was lowest for 2-hydroxynaphthalene at 0.67% and went up to 2.42% for 3-hydroxybenz[a]pyrene,
and the between-day relative standard deviation ranged from 3.84% for 9-hydroxyphenanthrene to 10.42% for 2-hydroxyfluorene.
The correlation coefficients were between 0.9962 and 0.9998. The developed method was successfully used to analyze samples
from student volunteers in a high school. 相似文献
9.
María J. Trujillo-Rodríguez Omprakash Nacham Kevin D. Clark Verónica Pino Jared L. Anderson Juan H. Ayala Ana M. Afonso 《Analytica chimica acta》2016
This work describes the applicability of magnetic ionic liquids (MILs) in the analytical determination of a group of heavy polycyclic aromatic hydrocarbons. Three different MILs, namely, benzyltrioctylammonium bromotrichloroferrate (III) (MIL A), methoxybenzyltrioctylammonium bromotrichloroferrate (III) (MIL B), and 1,12-di(3-benzylbenzimidazolium) dodecane bis[(trifluoromethyl)sulfonyl)]imide bromotrichloroferrate (III) (MIL C), were designed to exhibit hydrophobic properties, and their performance examined in a microextraction method for hydrophobic analytes. The magnet-assisted approach with these MILs was performed in combination with high performance liquid chromatography and fluorescence detection. The study of the extraction performance showed that MIL A was the most suitable solvent for the extraction of polycyclic aromatic hydrocarbons and under optimum conditions the fast extraction step required ∼20 μL of MIL A for 10 mL of aqueous sample, 24 mmol L−1 NaOH, high ionic strength content of NaCl (25% (w/v)), 500 μL of acetone as dispersive solvent, and 5 min of vortex. The desorption step required the aid of an external magnetic field with a strong NdFeB magnet (the separation requires few seconds), two back-extraction steps for polycyclic aromatic hydrocarbons retained in the MIL droplet with n-hexane, evaporation and reconstitution with acetonitrile. The overall method presented limits of detection down to 5 ng L−1, relative recoveries ranging from 91.5 to 119%, and inter-day reproducibility values (expressed as relative standard derivation) lower than 16.4% for a spiked level of 0.4 μg L−1 (n = 9). The method was also applied for the analysis of real samples, including tap water, wastewater, and tea infusion. 相似文献
10.
Walter B. Wilson Andréia A. Costa Huiyong Wang José A. Dias Sílvia C.L. Dias Andres D. Campiglia 《Analytica chimica acta》2012
The analytical performance of BEA – a commercial zeolite – is evaluated for the pre-concentration of fifteen Environmental Protection Agency – polycyclic aromatic hydrocarbons and their subsequent HPLC analysis in tap and lake water samples. The pre-concentration factors obtained with BEA have led to a method with excellent analytical figures of merit. One milliliter aliquots were sufficient to obtain excellent precision of measurements at the parts-per-trillion concentration level with relative standard deviations varying from 4.1% (dibenzo[a,h]anthracene) to 13.4% (pyrene). The limits of detection were excellent as well and varied between 1.1 (anthracene) and 49.9 ng L−1 (indeno[1,2,3-cd]pyrene). The recovery values of all the studied compounds meet the criterion for regulated polycyclic aromatic hydrocarbons, which mandates relative standard deviations equal or lower than 25%. The small volume of organic solvents (100 μL per sample) and amount of BEA (2 mg per sample) makes sample pre-concentration environmentally friendly and cost effective. The extraction procedure is well suited for numerous samples as the small working volume (1 mL) facilitates the implementation of simultaneous sample extraction. These are attractive features when routine monitoring of numerous samples is contemplated. 相似文献
11.
Naphthalene, biphenyl, acenaphtene, anthracene and pyrene were extracted from water samples using inner walls of polytetrafluoroethylene capillary. Optimum conditions for sorption, desorption and heart-cutting of the analyte zone were found. Combined on-line solid-phase extraction and HPLC method for determination of these compounds was proposed. Limits of detection were: (μg L−1): 0.4 (naphthalene), 0.3 (biphenyl), 0.6 (acenaphtene), 0.2 (anthracene) and 0.1 (pyrene). 相似文献
12.
A method for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in milk and related products based on direct immersion-solid phase microextraction (DI-SPME) followed by gas chromatography-mass spectrometry detection (GC-MS) has been developed. The influence of various parameters on PAH extraction efficiency was carefully monitored. Good performance (recovery, precision and quantitation limits) was attained when a PDMS/DVB fiber was immersed in the sample for 60 min at 55 °C. Detection limits ranged from 0.003 to 1.5 μg L−1 at a signal-to-noise ratio of 3, depending on the compound and the sample. The proposed method was successfully applied to infant formulas, milk and related products and the presence of both fluoranthene and pyrene in two samples was confirmed. 相似文献
13.
Vahid Khalili-Fard Kamal GhanemiYadollah Nikpour Mehdi Fallah-Mehrjardi 《Analytica chimica acta》2012
The application of sulfur microparticles as efficient adsorbents for the solid-phase extraction (SPE) and determination of trace amounts of 10 polycyclic aromatic hydrocarbons (PAHs) was investigated in sea water and wastewater samples using high performance liquid chromatography coupled with an ultraviolet detector (HPLC–UV). Parameters influencing the preconcentration of PAHs such as the amount of sulfur, solution flow rate and volume, elution solvent, type and concentration of organic modifier, and salt effect were examined. The results showed that at a flow rate of 10 mL min−1 for the sample solutions (100 mL), the PAHs could be adsorbed on the sulfur microparticles and then eluted by 2.0 mL of acetonitrile. For HPLC–UV analysis of extracted PAHs, the calibration curves were linear in the range of 0.05–80.0 μg L−1; the coefficients of determinations (r2) were between 0.9934 and 0.9995. The relative standard deviations (RSDs) for eight replicates at two concentration levels (0.5 and 4.0 μg L−1) of PAHs were lower than 7.3%, under optimized conditions. The limits of detection (LODs, <!-- no-mfc -->S/N<!-- /no-mfc --> = 3) of the proposed method for the studied PAHs were 0.007–0.048 μg L−1. The recoveries of spiked PAHs (0.5 and 4 μg L−1) in the wastewater and sea water samples ranged from 78% to 108%. The simplicity of experimental procedure, high extraction efficiency, short sample analysis, and using of low cost sorbent demonstrate the potential of this approach for routine trace PAH analysis in water and wastewater samples. 相似文献
14.
采用固相微萃取-气相色谱质谱法联用测定了水体中痕量多环麝香类化合物。对固相微萃取条件和解析条件进行了优化,确定了微萃取条件为:选用65μmPDMS-DVB萃取头、顶空萃取模式(HS),在800 r/min,60℃条件下,萃取45 min;萃取过程中保持pH 7并且不加入NaCl;解析条件为:解析时间为3 min,插入GC深度为4 cm,进样口温度为250℃。方法的检测限为0.29~0.37 ng/L,线性范围5~1000ng/L,相对标准偏差1.5%~2.2%。对实际污水厂不同类型的水样使用优化后的实验条件进行了验证试验,目标化合物的回收率在82.5%~92.8%之间,表明优化后的试验条件适用于实际水体中痕量多环麝香类化合物的分析测定。 相似文献
15.
Periodic mesoporous organosilica based on alkylimidazolium ionic liquid (PMO-IL) was prepared and used as a highly porous fiber coating material for solid-phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless steel wire for fabrication of the SPME fiber. The fiber was evaluated for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions in combination with gas chromatography–mass spectrometry (GC–MS). A one at-the-time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. In optimum conditions, the repeatability for one fiber (n = 3), expressed as relative standard deviation (R.S.D.%), was between 4.3% and 9.7% for the test compounds. The detection limits for the studied compounds were between 4 and 9 pg mL−1. The developed method offers the advantage of being simple to use, with shorter analysis time, lower cost of equipment, thermal stability of fiber and high relative recovery in comparison to conventional methods of analysis. 相似文献
16.
Xinna Zhao Xiujuan Liu Zhixu Zhao Changjiang Huang Minghua Zhang Huili Wang Xuedong Wang 《Journal of separation science》2009,32(12):2051-2057
In this article, homogeneous liquid–liquid extraction (HOLLE), combined with HPLC-fluorescence detector (HPLC-FLD), has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in vegetables. ACN was used as extraction solvent for the extraction of target analytes from vegetables. When the previous extraction process was over, the ACN extract was transferred to the water-immiscible organic phase, tetrachloroethane, used as extraction solvent in HOLLE procedures. Under the optimum conditions, repeatability was carried out by spiking PAHs at concentration level of 12.5 μg/kg, the RSDs varied between 1.1 and 8.5% (n = 3). The LODs, based on S/N of 3, ranged from 0.025 to 0.25 μg/kg. Relative recoveries of PAHs from cucumber and long crooked squash samples were in the range of 72.4–104.9% and 65.5–119.3%, respectively. Compared with the conventional extraction method, the proposed method has the advantage of being quick, easy to operate, and having low consumption of organic solvent. 相似文献
17.
Determination of polycyclic aromatic hydrocarbons in water samples using high-performance liquid chromatography with amperometric detection 总被引:2,自引:0,他引:2
The determination of polycyclic aromatic hydrocarbons (PAHs) using high-performance liquid chromatography (HPLC) with UV and fluorescence detection has been well established. Although most of the PAHs can be detected by these methods, some environmentally important polyaromatic compounds, such as acenaphthylene, do not show fluorescence and can only be determined by UV detection at higher concentrations. A sensitive and selective determination of acenaphthylene, acenaphthene and the six PAHs listed in the TVO, the German drinking water standard, is also possible by amperometric detection following HPLC separation. The method was applied to the determination of PAHs in different water samples after solid-phase extraction (SPE). The efficiency of the amperometric determination was found to be superior to UV detection (λ = 300 nm). 相似文献
18.
A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L−1) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 μL), then back-extracted into the 6 μL acidified aqueous solution (acceptor phase, HCl 0.5 mol L−1) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 μL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L−1 NaOH with 10% NaCl; organic phase: 20 μL of toluene; acceptor phase: 6 μL of 0.5 mol L−1 HCl and 600 m mol L−1 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 μg L−1 (R > 0.9991), and also the limits of detection were in the range of 0.01-0.1 μg L−1. The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions. 相似文献
19.
Development of a dispersive liquid–liquid microextraction method using a lighter‐than‐water ionic liquid for the analysis of polycyclic aromatic hydrocarbons in water 下载免费PDF全文
A dispersive liquid–liquid microextraction method using a lighter‐than‐water phosphonium‐based ionic liquid for the extraction of 16 polycyclic aromatic hydrocarbons from water samples has been developed. The extracted compounds were analyzed by liquid chromatography coupled to fluorescence/diode array detectors. The effects of several experimental parameters on the extraction efficiency, such as type and volume of ionic liquid and disperser solvent, type and concentration of salt in the aqueous phase and extraction time, were investigated and optimized. Three phosphonium‐based ionic liquids were assayed, obtaining larger extraction efficiencies when trihexyl‐(tetradecyl)phosphonium bromide was used. The optimized methodology requires a few microliters of a lighter‐than‐water phosphonium‐based ionic liquid, which allows an easy separation of the extraction solvent phase. The obtained limits of detection were between 0.02 and 0.56 μg/L, enrichment factors between 109 and 228, recoveries between 60 and 108%, trueness between 0.4 and 9.9% and reproducibility values between 3 and 12% were obtained. These figures of merit combined with the simplicity, rapidity and low cost of the analytical methodology indicate that this is a viable and convenient alternative to the methods reported in the literature. The developed method was used to analyze polycyclic aromatic hydrocarbons in river water samples. 相似文献
20.
Geng Leng Guibin Lui Yong Chen Hui Yin Dezhong Dan 《Journal of separation science》2012,35(20):2796-2804
A simple, rapid, and efficient method, vortex‐assisted extraction followed by dispersive liquid–liquid microextraction (DLLME) has been developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) in sediment samples prior to analysis by high performance liquid chromatography fluorescence detection. Acetonitrile was used as collecting solvent for the extraction of PAHs from sediment by vortex‐assisted extraction. In DLLME, PAHs were rapidly transferred from acetonitrile to dichloromethane. Under the optimum conditions, the method yields a linear calibration curve in the concentration range from 10 to 2100 ng g?1 for fluorene, anthracene, chrysene, benzo[k]fluoranthene, and benzo[a]pyrene, and 20 to 2100 ng g?1 for other target analytes. Coefficients of determinations ranged from 0.9986 to 0.9994. The limits of detection, based on signal‐to‐noise ratio of three, ranged from 2.3 to 6.8 ng g?1. Reproducibility and recoveries was assessed by extracting a series of six independent sediment samples, which were spiked with different concentration levels. Finally, the proposed method was successfully applied in analyses of real nature sediment samples. The proposed method extended and improved the application of DLLME to solid samples, which greatly shorten the extraction time and simplified the extraction process. 相似文献