1.
2.
This study used reversed-phase liquid chromatography–tandem mass spectrometry and supercritical fluid chromatography–tandem mass spectrometry for determination of the stereoisomers of chlorfenvinphos and dimethylvinphos in tobacco. Tobacco samples were extracted and purified with a modified quick, easy, cheap, effective, rugged, and safe technique using spherical carbon. The performance of both methodologies was comprehensively compared in terms of methods validation parameters (separation efficiency, linearity, selectivity, recovery, repeatability, sensitivity, matrix effect, etc.). Under optimized conditions, the calibration curves of the stereoisomers of chlorfenvinphos and dimethylvinphos in the range of 10–500 ng/mL showed excellent linearity with R2 ≥ 0.997 in both methods. The adequate recoveries of analytes from three different spiked tobaccos were obtained using reversed-phase liquid chromatography–tandem mass spectrometry (86.1–95.7%) as well as supercritical fluid chromatography–tandem mass spectrometry (86.5–94.0%). The relative standard deviations for spiked samples were all below 7.0%. Compared with supercritical fluid chromatography–tandem mass spectrometry, lower matrix effects and LODs can be obtained in reversed-phase liquid chromatography–tandem mass spectrometry.  相似文献   

3.
The use of powerful mass spectrometric detectors in combination with liquid chromatography has played a vital role to solve many problems related to food safety. Since this technique is especially well suited for, but not restricted to the analysis of food contaminants within the food safety area, this review is focused on providing an insight into this field. The basic legislation in different parts of the world is discussed with a focus on the situation within the European Union (EU) and why it favors the use of liquid chromatography–mass spectrometry (LC–MS). Main attention in this review is on the achievements that have been possible because of the latest advances and novelties in mass spectrometry and how these progresses have influenced the best control of food allowing an increase in the food safety and quality standards. Emphasis is given to the potential and pitfalls of the different LC–MS approaches as well as in its possibilities to address current hot issues in food safety, such as the development of large-scale multi-residue methods and the identification of non-target and unknown compounds. Last but not least, future perspectives and potential directions are also outlined highlighting prospects and achievements.  相似文献   

4.
5.
Non-steroidal anti-inflammatory drugs are widely used for treatment of animals. According to Council Directive 96/23/EC, residues of these drugs must be monitored because of the potential risk they pose to the consumers' health. For this reason an LC-MS-MS method was developed for detection of wide range of NSAIDs, including both "acidic" NSAIDs (carprofen, diclofenac, flunixin, meloxicam, phenylbutazone, oxyphenbutazone, tolfenamic acid, mefenamic acid, naproxen, ketoprofen, ibuprofen, firocoxib, rofecoxib, and celecoxib) and "basic" NSAIDs (four metamizole metabolites). Analytes were extracted from milk samples with acetonitrile in the presence of ammonium acetate. One portion of the extract was directly analyzed for the presence of metamizole metabolites; a second portion was cleaned with an amino cartridge. All NSAIDs were separated on a Phenomenex Luna C8(2) column and analyzed by LC-MS-MS in negative (acidic NSAIDs) and positive (metamizole metabolites) ion modes. The method was validated in accordance with the requirements of Commission Decision 2002/657/EC. Within-laboratory reproducibility was in the range 7-28%, and accuracy was in the range 71-116%. The method enabled detection of all the analytes with the expected sensitivity, below the recommended concentrations. The method fulfills the criteria for confirmatory methods and, because of its efficiency, may also be used for screening purposes. The procedure was also successfully verified in the proficiency test organized by EU-RL in 2010. As far as the authors are aware, this is one of the first methods capable of detecting diclofenac residues below the MRL in milk (0.1 μg kg(-1)). An additional advantage is the possibility of simultaneous determination of "acidic" NSAIDs and metamizole metabolites.  相似文献   

6.
Electrophilic attack of aristolactam-nitrenium ion by the C7 position to the exocyclic amino group in the DNA bases led to the formation of the major adducts. In this study, liquid chromatography coupled with electrospray ionization tandem mass spectrometry was applied to the study of DNA adducts of aristolochic acid (AA). When DNA (bases and CT-DNA) was incubated with AA, dG-AAI, dG-AAII, dA-AAI, dA-AAII, dC-AAI, and dC-AAII were detected and characterized. The dC adducts of AA were identified for the first time. The soft ionization technology allowed detection of the intact DNA adducts. High-resolution MS and MS-MS capabilities of a quadrupole time-of-flight mass spectrometer were shown to be efficient for DNA adducts analysis. DNA-AA adducts showed characteristic fragmentation patterns in MS-MS analysis. The dissociative loss of 116 Da from the DNA-AA adducts, which resulted from internal hydrogen transfer and cleavage at the C-N glycosidic bond, provided a characteristic fragment for the structural elucidation.  相似文献   

7.
8.
Data precision in the analysis by purge-and-trap coupled on-line to gas chromatography–mass spectrometry (P&T-GC–MS) of honey volatiles has been studied by statistical analysis. The contribution of non-random factors to dispersion of quantitative results was proven by comparing several statistical parameters (correlation coefficients, principal component analysis (PCA) eigenvalues and loadings) from both experimental and simulated data. PCA was also useful for grouping volatiles with similar dispersion behaviour; these groups being generally related to compounds with common properties or structural features. The use of area ratios improves data precision for compounds within the same group. Results from this study could be used for a better selection of internal standards in quantitative analysis of volatiles by P&T-GC–MS.  相似文献   

9.
Current strategies in the LC–MS analysis of pesticides and related compounds in environmental samples, fruits and vegetables, and biological samples mostly rely on the selection of appropriate precursor/product-ion combinations (transitions) for selected reaction monitoring (SRM), often based on automated parameter optimization and selection of the transition. Such a procedure does not require any information on the type of fragmentation reaction involved in the generation of the product ion from the selected precursor ion. However, such information does become important in untargeted screening for unknown contaminants in environmental and food samples, which are generally based on a combination of high-resolution mass spectrometry and (multistage) tandem mass spectrometry. With this in mind, the group-specific fragmentation behaviour has been studied for six classes of pesticides and herbicides, i.e., triazines, organophosphorous pesticides, phenylurea herbicides, carbamates, sulfonylurea herbicides, and chlorinated phenoxy acid herbicides. When relevant, some comparison was made between fragmentation of protonated molecules in MS–MS and of molecular ions generated by electron ionization in GC–MS.  相似文献   

10.
In this study, fourteen highly polar aminoglycoside (AGs) antibiotics were selected. Various stationary phases were tested, including Obelisc R, ZIC-HILIC, BEH amide and aminopropyl. The nature of the stationary phase, mobile phase (water or buffer solutions and acetonitrile), pH (percentage of formic acid), gradient conditions and injection solvents were systematically studied as relevant parameters for tuning retention selectivity and detectability of AGs in liquid chromatography electrospray tandem mass spectrometry (LC–(ESI)–MS/MS). Only the two zwitterionic phases (Obelisc R and ZIC-HILIC) achieved a proper chromatographic separation considering interferences due to the crosstalk effect in low resolution mass spectrometers. The water/acetonitrile mobile phase containing 1% formic acid used with Obelisc R provided more sensitivity than the highly concentrated buffered mobile phases required for ZIC-HILIC. A solid phase extraction (SPE) clean-up procedure with polymeric weak cation exchange (WCX) cartridges was optimized for honey, milk and liver samples. Different brands of cartridges and elution solvents were tested, and the Taurus WCX offered the best recovery rate with a buffer elution at pH 3. The final optimized method was validated in these matrices according to Decision 2002/657/EC. A monitoring campaign for sixty honey, milk and liver samples was carried out at the Food Authority Control in Geneva. The concentration of dihydrostreptomycin (DSTP) found in one ovine liver exceeded the established maximum residue levels (MRLs) within the European and Swiss legislations but it was compliant taking into account the validation data.  相似文献   

11.
A new LC–MS/MS method for the separation and detection of the most prominent marine lipophilic toxin groups comprising okadaic acid, dinophysistoxins, yessotoxins, azaspiracids, pectenotoxins, spirolides and some okadaic acid fatty acid esters has been developed. With this method 28 different marine lipophilic biotoxins can be analysed in a single run. Separation was achieved with an acetonitrile/water gradient containing ammonium hydroxide (pH 11). All toxins were stable under these basic conditions. Compared to chromatography using an acidic gradient, the limit of detection (LODs) for okadaic acid, yessotoxin, gymnodimine and 13-desmethyl spirolide C were improved two- to three-fold, mainly due to better peak shapes. The azaspiracids and pectenotoxins-2 showed comparable LODs under acidic and basic conditions. A major advantage of the developed method is that toxins can be clustered in retention time windows separated for positively and negatively ionized molecular ions. Therefore, there is no need for rapid polarity switching or two separate runs for one sample. The new method showed good repeatability and reproducibility and is an important step in the development of alternatives to the animal tests currently in use for shellfish toxin analysis.  相似文献   

12.
The present work describes the development and validation of an analytical method based on liquid chromatography (LC), coupled with tandem mass spectrometry (MS/MS) that allows the determination and confirmation of several endocrine-disrupting chemicals (EDCs) in honey. The EDCs studied were nine phenols of different nature: chlorophenols (2,4-dichlorophenol, 2,4,5-trichlorophenol, and pentachlorophenol), alkylphenols (4-tert-butylphenol, 4-tert-octylphenol, and 4-n-octylphenol) bisphenols (bisphenol-A and bisphenol-F), and 4-tert-butylbenzoic acid. The method incorporates a restricted-access material (RAM), coupled on-line to the LC-MS/MS system, which allows direct injection of the matrix into the RAM-LC-MS/MS system. The optimized method developed, RAM-LC-MS/MS, was applied to fortified honey samples, affording detection limits in the 0.6–7.2 ng g−1 range, calculated for a signal-to-noise ratio of 3. In addition, the method was validated as a quantitative confirmatory method according to European Union Decision 2002/657/EC. The validation criteria evaluated were linearity, repeatability, reproducibility, recovery, decision limits, detection capabilities, specificity, and ruggedness. Repeatability and within-laboratory reproducibility were evaluated at two concentration levels, being ±11% or below at 20 ng g−1. The decision limits (CCα) and detection capabilities (CCβ) were in the 1.7–12.6 and 2.8–21.6 ng g−1 range, respectively.  相似文献   

13.
An efficient method for fast elucidation of the electrochemical reactions of polycyclic aromatic hydrocarbons (PAH) has been set up by applying post-column electrochemistry in liquid chromatography–mass spectrometry (LC–MS). With this set-up strong improvement of sensitivity in the LC–MS analysis of PAH is observed. Due to their low redox potentials, the non-polar PAH are converted into the respective radical cations, which may further react with constituents of the mobile phase and in additional electrochemical oxidation steps. Among other products, mono-, di-, and trioxygenated species are observed in aqueous solutions, alkoxylated compounds in alcohols, and solvent adducts in the presence of acetonitrile. While more different products are observed by using atmospheric pressure chemical ionization in the positive-ion mode (APCI(+)), the deprotonation of hydroxylated species results in very clear spectra in the negative-ion mode (APCI(–)). Deuterated PAH and deuterated solvents were used to gain additional information on the formation of the reaction products.  相似文献   

14.
Terpene-conjugated curcuminoids are conjugates of curcuminoids and bisabolanes in the rhizomes of Curcuma longa L. The fragmentation pathways of known three terpene-conjugated curcuminoids (bisabolocurcumin-ether, bisabocurcumin, and demethoxybisabolocurcumin ether) and curcumin, demethoxycurcumin, and bisdemethoxycurcumin were investigated using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry in negative mode to rapidly search and discover similar unknown compounds of the acetone fraction of turmeric. Subsequently, compounds 1–3 were founded in the acetone fraction based on molecular weight and above fragmentation pathways (the characteristic fragment ions, the most and second most abundant fragment ions produced in MS2 spectra). Terpecurcumin X ( 1 ) and terpecurcumin Y ( 3 ) were further separated by liquid chromatography–tandem mass spectrometry guided isolation technique to verify their structures by nuclear magnetic resonance, electrospray ionization high-resolution mass spectroscopy, ultraviolet and visible spectra and infrared spectra. Interestingly, 1 and 3 were new compounds. The results indicate the feasibility and significant advantages of liquid chromatography–tandem mass spectrometry for the rapid discovery and analysis of new constituents in traditional Chinese medicine. In vitro, Terpene-conjugated curcuminoids had better nitric oxide inhibitory activity than the other seven curcuminoids (demethoxycurcumin, bisdemethoxycurcumin, curdione, curcumenone, bisacurone, curcumenol, and germacron).  相似文献   

15.
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 μm, 50 mm × 2.1 mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0–103.4%, with the RSD < 15%. The calibration curves for alkylphenols were linear within the range of 0.01–0.4 μg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 μg/kg.  相似文献   

16.
Penindolone (PND) is a novel influenza A virus dual inhibitor that blocks hemagglutinin-mediated adsorption and membrane fusion. A sensitive and specific ultra-performance liquid chromatography–tandem mass spectrometry method was developed and validated to determine PND in rat plasma. Plasma sample preparation was a simple deproteinization with acetonitrile followed by centrifugation. Chromatographic separation was performed on a C18 column with a gradient mobile phase of acetonitrile–water containing 0.1% formic acid. Detection was carried out by electrospray ionization in negative ion multiple reaction monitoring mode. Linear detection responses were obtained for PND ranging from 1 to 1,000 ng/ml. The intra- and inter-day precision (relative standard deviations, RSD) were within 6.5%, and accuracy (relative error, RE) was within ±11.0%. The extraction recovery data for PND and internal standard (IS) were >96.0%. PND was proved to be stable during the sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic and bioavailability studies for PND in rats. The results showed the existence of twin peaks, gender difference and nonlinear pharmacokinetics for PND. In addition, two oxidation metabolites and three glucuronidation metabolites of PND were detected by ultra-high-performance liquid chromatography–high resolution mass spectrometry.  相似文献   

17.
A new, fast and efficient multiple reaction monitoring (MRM) high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for the determination of cyclopiazonic acid (CPA) in mixed feed, wheat, peanuts and rice is presented. The analytical methodology involves sample extraction with an alkaline methanol–water mixture, defatting with hexane and quantification using HPLC–MS/MS without further treatment of sample extracts. Reversed-phase liquid chromatography using a C18 stationary phase coupled to negative mode electrospray triple quadrupole tandem mass spectrometry was applied. The limit of detection was 5 μg/kg while the limit of quantification was 20 μg/kg in the matrices investigated. The detector response was found to be linear over the range 25–250 μg/kg in feed and 25–500 μg/kg in wheat, peanuts and rice. The mean overall recoveries (n = 18) of CPA varied from 79% to 114% in the range of concentrations studied over a period of 4 months. Mean recoveries (n = 3 or 6) of CPA in wheat, peanuts and rice varied from 70% to 111%, 77% to 116% and 69% to 92%, respectively. The method was successfully applied to the analysis of feed and rice samples artificially infected with the fungal strain Penicillium commune, where the toxin was found at different levels.  相似文献   

18.
Evodiamine and rutecarpine are two kinds of indole alkaloids contained in the fruit of Evodiae fructus, which have been shown to exhibit various bioactivities in humans. A liquid chromatography–tandem mass spectrometric method (LC–MS/MS) was developed for the determination of evodiamine and rutecarpine in human serum. The serum was extracted by solid-phase extraction (SPE) and analyzed using a C18 column and a mobile phase consisting of methanol–water (85:15) solution containing 5 mmol/L ammonium formate at a flow rate of 0.5 mL/min. The mass spectrometer was operated in positive mode, employing the extracted ion chromatogram (EIC) for detection and quantitation of evodiamine (m/z 288) and rutecarpine (m/z 304). Good linear relationships between the peak area and the concentration were obtained in the ranges of 5.2–1040 ng/mL and 10.2–1020 ng/mL, with correlation coefficients (r) of 0.999 and 0.998, for evodiamine and rutecarpine, respectively. The repeatabilities (RSD, n=6) of quantitation for evodiamine and rutecarpine were 2.18–4.00% and 2.99–5.67%, respectively, and the recovery ranged from 90.5% to 98.1%. A comparative study of the different ionization and quantitation modes, including ESI–MS, ESI–MS/MS, APCI–MS and APCI–MS/MS, was also accomplished. The MS/MS fragmentation mechanism of the base peak ([M+H]+, m/z 304) of evodiamine was investigated in order to identify the analytes in more complicated body fluid samples.   相似文献   

19.
A method for the simultaneous analysis of nucleosides and nucleotides in infant formula using reversed-phase liquid chromatography–tandem mass spectrometry is described. This approach is advantageous for compliance testing of infant formula over other LC-MS methods in which only nucleotides or nucleosides are measured. Following sample dissolution, protein was removed by centrifugal ultrafiltration. Chromatographic analyses were performed using a C18 stationary phase and gradient elution of an ammonium acetate/bicarbonate buffer, mass spectrometric detection and quantitation by a stable isotope-labelled internal standard technique. A single laboratory validation was performed, with spike recoveries of 80.1–112.9 % and repeatability relative standard deviations of 1.9–7.2 %. Accuracy as bias was demonstrated against reference values for NIST1849a certified reference material. The method has been validated for the analysis of bovine milk-based, soy-based, caprine milk-based and hydrolysed milk protein-based infant formulae.
Figure
LC-MS/MS MRM chromatogram of mixed nucleoside and nucleotide standard  相似文献   

20.
A gas chromatography–tandem mass spectrometric (GC-MS/MS) method has been developed for the determination of carbofuran (2,3-dihydro-2,2-dimethylbenzofuran-7-yl methylcarbamate), carbaryl (1-naphthyl-N-methylcarbamate) and their main metabolites in human blood plasma. Optimization of the isolation of the compounds from plasma matrix included the precipitation, denaturation and digestion of plasma proteins. Derivatization was achieved by the use of trifluoroacetic acid anhydride and was optimized for temperature, time and volume of derivatization agent. In the proposed method, a mild precipitation technique was applied using β-mercaptoethanol and ascorbic acid in combination with solid-phase extraction technique using Oasis HLB (Hydrophobic Lipophilic Balance) cartridges for further clean up of samples. Carbamate linkage was not hydrolyzed to its phenol product, but both carbamate phenol and ketones were transformed into trifluoroacetyl derivatives in order to become volatile compounds and were determined using tandem mass spectrometry. The linearity of the method was shown for nine concentrations in the range of 0.50–250 ng mL−1 in fortified plasma aliquots. Limits of detection (LODs) for all compounds ranged from 0.015–0.151 ng mL−1. Inter-day and intra-day assays (RSD) for all compounds, at three concentration levels of 2.5, 25 and 100 ng mL−1 (n=3) in fortified plasma samples were less than 18%. Accuracy (%E r) was calculated at three concentration levels, 8, 80 and 160 ng mL−1 (n=3), and ranged from −12.0 to 15.0%. Matrix effect was evaluated so mean recoveries were calculated for all compounds and ranged from 81–107%. Specificity for the use of this method to biological monitoring studies was achieved including four main metabolites of CF, 1-naphthol and 2-naphthol from the naphthalene metabolism pathways, and both the parent compound of carbofuran and carbaryl. The proposed method was applied to plasma samples of pesticide users.  相似文献   