首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The ion-exchange separation of organic anions of varying molecular mass has been demonstrated using ion chromatography with isocratic, gradient and multi-step eluent profiles on commercially available columns with UV detection. A retention model derived previously for inorganic ions and based solely on electrostatic interactions between the analytes and the stationary phase was applied. This model was found to accurately describe the observed elution of all the anions under isocratic, gradient and multi-step eluent conditions. Hydrophobic interactions, although likely to be present to varying degrees, did not limit the applicability of the ion-exchange retention model. Various instrumental configurations were investigated to overcome problems associated with the use of organic modifiers in the eluent which caused compatibility issues with the electrolytically derived, and subsequently suppressed, eluent. The preferred configuration allowed the organic modifier stream to bypass the eluent generator, followed by subsequent mixing before entering the injection valve and column. Accurate elution prediction was achieved even when using 5-step eluent profiles with errors in retention time generally being less than 1% relative standard deviation (RSD) and all being less than 5% RSD. Peak widths for linear gradient separations were also modelled and showed good agreement with experimentally determined values.  相似文献   

2.
Reversed-phase ultra-performance liquid chromatography was used for biopolymer separations in isocratic and gradient mode. The gradient elution mode was employed to estimate the optimal mobile phase flow rate to obtain the best column efficiency and the peak capacity for three classes of analytes: peptides, oligonucleotides and proteins. The results indicate that the flow rate of the Van Deemter optimum for 2.1 mm I.D. columns packed with a porous 1.7 microm C18 sorbent is below 0.2 mL/min for our analytes. However, the maximum peak capacity is achieved at flow rates between 0.15 and 1.0 mL/min, depending on the molecular weight of the analyte. The isocratic separation mode was utilized to measure the dependence of the retention factor on the mobile phase composition. Constants derived from isocratic experiments were utilized in a mathematical model based on gradient theory. Column peak capacity was predicted as a function of flow rate, gradient slope and column length. Predicted peak capacity trends were compared to experimental results.  相似文献   

3.
The linear-solvent strength (LSS) model of gradient elution has been applied to estimate parameters of lipophilicity and acidity of a series of drugs and model chemicals. Apparent pKa values and log kw values for individual analytes were determined in 2-3 gradient runs. The first experiment (or first two experiments) uses a wide-range organic modifier gradient with pH chosen for suppressed ionization of the analyte. The result of this experiment allows an estimate of contents of organic modifier of the mobile phase (%B) providing the required retention coefficient, k, for the non-ionized analyte. The following experiment is carried out with the latter %B and a pH-gradient of the aqueous component of the eluent that is sufficient to overlap the possible pKa-value of the analyte. The initial pH of the buffer used to make the mobile phase is selected to insure that the analyte is in non-ionized form. The resulting retention time allows an estimate of PKa in a solvent of the selected %B. At the same time, estimates of log kw can also be obtained. The log kw parameter obtained from gradient HPLC by the approach proposed correlated well with the corresponding value obtained by standard procedure of extrapolation of retention data determined in a series of isocratic measurements. Correlation between log kw and the reference parameter of lipophilicity, log P, was very good for a series of test analytes and satisfactory for a structurally diverse series of drugs. The approach supported with specific detection procedures can be recommended for fast screening of lipophilicity of individual components of complex mixtures like those produced by combinatorial chemistry. The values of pKa obtained in a study were found to correlate with the literature pKa data determined in water for a set of aniline derivatives studied. In case of a series of drugs the correlation was less than moderate if the general procedure of pKa determination was applied.  相似文献   

4.
Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

5.
The universality of the response of the Corona Charged Aerosol Detector (CoronaCAD) has been investigated under flow-injection and gradient HPLC elution conditions. A three-dimensional model was developed which relates the CoronaCAD response to analyte concentration and the mobile phase composition used. The model was developed using the response of four probe analytes which displayed non-volatile behavior in the CoronaCAD and were soluble over a broad range of mobile phase compositions. The analyte concentrations ranged from 1μg/mL to 1mg/mL, and injection volumes corresponded to on-column amounts of 25ng to 25μg. Mobile phases used in the model were composed of 0-80% acetonitrile, mixed with complementary proportions of aqueous formic acid (0.1%, pH 2.6). An analyte set of 23 compounds possessing a wide range of physicochemical properties was selected for the purpose of evaluating the model. The predicted response was compared to the actual analyte response displayed by the detector and the efficacy of the model under flow-injection and gradient HPLC elution conditions was determined. The average error of the four analytes used to develop the model was 9.2% (n=176), while the errors under flow-injection and gradient HPLC elution conditions for the evaluation set of analytes were found to be 12.5% and 12.8%, respectively. Some analytes were excluded from the evaluation set due to considerations of volatility (boiling point <400°C), charge and excessive retention on the column leading to elution outside the eluent range covered by the model. The two-part response model can be used to describe the relationship between response and analyte concentration and also to offer a correction for the non-linear detector response obtained with gradient HPLC for analytes which conform to the model, to provide insight into the factors affecting the CoronaCAD response for different analytes, and also as a means for accurately determining the concentration of unknown compounds when individual standards are not available for calibration.  相似文献   

6.
The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed tR vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.  相似文献   

7.
孙小丽  郝卫强  王俊德  狄斌  陈强  庄韦  俞强  张培培 《色谱》2013,31(8):753-757
根据前期得到的梯度液相色谱保留时间计算公式,在不指定溶剂强度模型形式的前提下,探讨了梯形梯度洗脱的一些特点。对于溶质在梯形梯度坡度上流出时的情形,推导得到溶质流出色谱柱所对应的流动相组成(φR)随梯度斜率(B)变化的表达式。该公式表明,在该情形中φR将会随着B值的增加而增加。对于溶质在梯形梯度最后一个等度区间流出时的情形,如果初始和终止流动相组成保持不变而仅有梯度的斜率发生变化时,从理论上证明了溶质保留时间(tR)与梯度斜率的倒数(1/B)之间呈线性关系。实验中以C18色谱柱为固定相,甲醇-水为流动相,联苯为样品,测定了不同流动相组成以及梯形梯度条件下的保留时间,所得到的实验值与理论值吻合,从而验证了理论方法的正确性。  相似文献   

8.
9.
The transferability of retention data among isocratic and gradient RPLC elution modes is studied. For this purpose, 16 beta-blockers were chromatographed under both isocratic and gradient elution with acetonitrile-water mobile phases. Taking into account the elution mode where the experimental data come from, and the mode where the retention should be predicted, the following combinations are possible: isocratic predictions from (i) isocratic or (ii) gradient experimental designs; and gradient predictions from (iii) isocratic or (iv) gradient data. Each of these possibilities was checked using three retention models that relate the logarithm of the retention factor: (a) linearly and (b) quadratically with the volume fraction of organic solvent, and (c) linearly with a normalised mobile phase polarity parameter. The study was carried out under two different perspectives: a straightforward examination of the prediction errors and the analysis of the uncertainties derived from the variance-covariance matrix of the fitted models. The best combinations of prediction mode and model were: (i)-(b), (ii)-(c), (iii)-(b), and (iv)-(a) or (c).  相似文献   

10.
The dual gradient column, in which both the chemical property of the stationary phase and the flow velocity in the mobile phase are heterogeneous longitudinally along the column, is developed to obtain the mobile phase gradient-like elution in an isocratic condition. Here, the step-wise dual gradient columns were prepared by connecting an inlet column (I.D. 50 microm, packed with ODS) serially to an outlet column (I.D. 100-200 microm, packed with the mixture of ODS and C1 [9:1]). The retention behavior of alkylbenzenes was able to be controlled in the dual gradient column depending on the variation in the flow velocity. Moreover, the change in retention behavior induced by the flow velocity variation for the dual gradient columns was quite different from that by the variation in organic modifier content of the mobile phase in isocratic elution for a single gradient column and can induce the similar effect with an ordinary gradient elution in a mobile phase composition.  相似文献   

11.
When facing separation problems in ion chromatography, chromatographers often lack guidelines to decide a priori if isocratic elution will give enough separation in a reasonable analysis time or a gradient elution will be required. This situation may be solved by the prediction of retention in gradient elution mode by using isocratic experimental data. This work describes the development of an ion chromatographic gradient elution retention model for fluoride, chloride, nitrite, bromide, nitrate, sulfate and phosphate by using isocratic experimental data. The isocratic elution retention model was developed by applying a polynomial relation between the logarithm of the retention factor and logarithm of the concentration of competing ions; the gradient elution retention model was based on the stepwise numerical integration of the corresponding differential equation. It was shown that the developed gradient elution retention model was not significantly affected by transferring data form isocratic experiment. The root mean squared prediction error for gradient elution retention model was between 0.0863 for fluoride and 0.7027 for bromide proving a very good predictive ability of developed gradient elution retention model.  相似文献   

12.
Iron(II) 1,10-phenanthroline, Fe(phen)3(2+), salts are used as mobile phase additives for the liquid chromatographic separation of alkyl sulfonates and sulfates on the reversed-phase PRP-1. As alkyl chain length increases retention increases. For a given chain length an alkyl sulfate is more retained than the corresponding alkyl sulfonate. Major elution variables that affect retention are mobile phase solvent and counteranion concentration. Indirect photometric detection is used to detect alkyl sulfonates and sulfates at 510 nm where Fe(phen)3(2+) salts absorb. Conditions for isocratic and gradient elution of multicomponent mixtures are described. Detection limits depending on analyte approached 0.1 nmol for isocratic elution and 3 nmol for gradient elution.  相似文献   

13.
This paper describes the results of the evaluation of retention dependence on the physicochemical properties of solutes in linear gradient elution by reversed-phase liquid chromatography (RPLC) based on linear solvation energy relationships (LSERs). Retention time data on Inertsil ODS(3) column by linear gradient elution were collected for both acetonitrile-water and methanol-water binary mobile phases under various gradient steepness. Based on the LSERs, the retention times were linearly correlated with the physicochemical properties (size, dipolarity, and hydrogen bond donor-acceptor acidity and basicity) of solutes. As predicted by LSERs, very acceptable linear relationships are observed for both mobile phases. While the magnitudes of the coefficients are modified by the gradient steepness, their signs are consistent with those obtained by isocratic elution. As obtained for isocratic elution, the dominant factors to retention in linear gradient elution of RPLC are the solutes' size and hydrogen bond acceptor basicity. The conclusions of the study allow us to predict retention in chromatographic method development by gradient elution.  相似文献   

14.
Chromatographers are cautioned to avoid gradient elution when isocratic elution will do. In this work, we compared the analytical properties of gradient and isocratic separations of a sample which can be done quite readily under isocratic conditions. We found that gradient elution gave a shorter overall analysis with similar resolution of the critical pair compared to isocratic elution without sacrificing repeatability in retention time, peak area and peak height or linearity of the calibration curve. We also obtained acceptable repeatability in peak area/height and linearity of calibrations curves for a sample that required gradient elution using a practical baseline subtraction technique. Based on these results and related work which show that columns can be reequilibrated by flushing with less than two column volumes of the initial eluent, we conclude that many of the reasons given to avoid gradient elution deserve serious reconsideration, especially for those samples which are easily separated isocratically. However, we believe isocratic elution will remain preferable when: (1) the sample contains less than 10 weakly retained components (i.e. the last peak elutes with k' < 5) or (2) the gradient baseline impedes trace analysis.  相似文献   

15.
Summary A general chromatographic model has been set up starting from a set of equations based on the concept of the velocity of a solute along the column. The composition of the mobile phase is taken into account solely as a numerical factor entering into suitable equations and totally independent of the chemical-properties of the constituents. A few isocratic experimental runs are necessary as input data, and subsequently a small amount of computational effort is sufficient to make predictions of retention times under gradient elution conditions for solutes of whatever chemical structure. The prediction errors are dependent on the steepness of the linear gradient chosen but are, in any case, acceptably low.  相似文献   

16.
We describe a liquid chromatography method development approach for the separation of intact proteins using hydrophobic interaction chromatography. First, protein retention was determined as function of the salt concentration by isocratic measurements and modeled using linear regression. The error between measured and predicted retention factors was studied while varying gradient time (between 15 and 120 min) and gradient starting conditions, and ranged between 2 and 15%. To reduce the time needed to develop optimized gradient methods for hydrophobic interaction chromatography separations, retention‐time estimations were also assessed based on two gradient scouting runs, resulting in significantly improved retention‐time predictions (average error < 2.5%) when varying gradient time. When starting the scouting gradient at lower salt concentrations (stronger eluent), retention time prediction became inaccurate in contrast to predictions based on isocratic runs. Application of three scouting runs and a nonlinear model, incorporating the effects of gradient duration and mobile‐phase composition at the start of the gradient, provides accurate results (improved fitting compared to the linear solvent‐strength model) with an average error of 1.0% and maximum deviation of –8.3%. Finally, gradient scouting runs and retention‐time modeling have been applied for the optimization of a critical‐pair protein isoform separation encountered in a biotechnological sample.  相似文献   

17.
Under the elution of methanol‐based mobile phase, the isocratic resolution of 12 biogenic amines, including 1 aromatic, 2 heterocyclic and 9 aliphatic amines, as the dansylated derivatives has been accomplished in less than 25 minutes on a 15 cm C8‐bonded column. The resolution can not be reproduced on other examined alkyl‐bonded phases (e.g., C4 and C18) under the same chromatographic conditions, or in the reversed‐phase mode. The retention, mainly as a result of hydrophobic interaction between analyte and stationary phase, can be adjusted by varying the percentage of methanol in the mobile phase. Also, incorporating acetic acid as additive to the mobile phase to protonate the analyte and silanol groups that are little shielding on the surface of silica gel reduces the dipole‐dipole interaction, and thus the retention scale, which in turn deteriorates the resolution. Furthermore, the elution reversal is plausible for some of analytes as a greater percent of acetic acid is used in the elution. Values of correlation coefficients (R2) range between 0.9995 and 0.9996, indicating good linearity.  相似文献   

18.
The regeneration of ion-pairing reagent distribution on liquid chromatography columns after gradient elution has been well recognized as the cause for long column equilibration time, a major drawback associated with gradient elution reverse phase ion-pair chromatography. To date, the majority of studies have focused on optimizing the separation conditions to shorten the equilibration time. There is limited understanding of the ion-pairing reagent distribution process between the mobile phase and stationary phase in the course of gradient elution, and subsequent column re-equilibration. The focus of this work is to gain a better understanding of this process. An ion-pair chromatographic system, equipped with a YMC ODS C(18) column and a mobile phase containing tetrabutylammonium (TBA) hydroxide as the ion-pairing reagent, was used in the study. The TBA distribution profile was established by measuring its concentration in the eluent fractions collected during the gradient cycle using different column equilibration times with an ion chromatographic method. Furthermore, the analyte retention time was evaluated as the function of the column equilibration time and TBA concentration in the mobile phase. The column equilibration and its impact on the method robustness will also be discussed.  相似文献   

19.
Previous studies of peptide separation by normal-phase liquid chromatography have shown a linear relationship between the logarithm of the capacity factor and the logarithm of the volume fraction of modifier in the mobile phase. This permitted the use of a model to predict isocratic and gradient retention times based on data obtained by two initial gradient runs. In the present study, chromatographic behavior of 25 peptides in normal-phase liquid chromatography with isocratic elution have been studied and a linear relationship between the slope (S) and intercept [log k(0)] was obtained. This relationship was combined with the algorithm of prediction reported in the previous paper. The prediction of peptide retention times with only a single experimental gradient retention data was investigated.  相似文献   

20.
Using isocratic retention parameters, the gradient elution retention time for several proteins has been calculated. The gradient retention time calculation is based on fitting the isocratic retention data to an equation of the form: log k' = m log (1/[Ca2+]) + log K and on applying well-established principles of gradient elution. A good correlation between the observed and calculated retention times for several test proteins was obtained at various total gradient times and column flow-rates. Conversely, isocratic retention parameters characterizing protein retention can be calculated from gradient elution retention data. However, even with retention data of high quality, small errors are amplified by the log-log nature of the ion-exchange isocratic retention model employed. Based on the close correlation between predicted and observed gradient retention times, no evidence for protein denaturation resulting from immobilization of the protein at high initial k' values at or near the column inlet was observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号