首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 93 毫秒
1.
Summary Chromium, iron and cobalt were determined in niobium by radiochemical neutron activation analysis. The main steps of the technique involved the irradiation of the samples in a medium or high-flux reactor, the post-irradiation decontamination of the sample surface, a two-step separation procedure based on anion-exchange from HF and HCl medium, and counting the separated indicator radionuclides with a well-type NaI-detector. For a 42-day irradiation at a thermal neutron flux of 8×1013 n cm–2 s–1 and a sample weight of 100 mg, the limits of detection are: 10 ppt for chromium, 1.5 ppb for iron and 4 ppt for cobalt. The results obtained by this technique are compared with data obtained by radiochemical proton activation analysis and atomic absorption spectrometry.
Bestimmung von Chrom, Eisen und Cobalt in hochreinem Niob durch radiochemische Neutronenaktivierungsanalyse
Zusammenfassung Die Hauptschritte der Methode sind die Bestrahlung der Probe in einem Mittel- oder Hochflußreaktor, eine anschließende Oberflächendekontamination und die spezifische Abtrennung der Indicatorradionuklide mittels Anionaustausch aus Flußsäure- und Salzsäure-Medium, sowie die Messung der Radionuklid-Fraktionen mit einem Natriumjodid-Detektor.Für eine 42tägige Bestrahlung mit Reaktorneutronen bei einem thermischen Fluß von 8×1013 n cm–2 s–1 konnte bei einem Probengewicht von 100 mg für Chrom eine Nachweisgrenze von 10 ppt, für Eisen von 1,5 ppb und für Cobalt von 4 ppt erreicht werden.Die mit dem Verfahren erhaltenen Ergebnisse werden mit denen der radiochemischen Protonenaktivierungsanalyse und der Atomabsorptions-Spektrometrie verglichen.
  相似文献   

2.
Summary Two methods for the determination of ascorbic acid are described. The first employs titration with iodate in presence of cyanide and hydrochloric acid and starch indicator with two end points, corresponding to the formation of iodine after reduction to iodide and conversion of iodine to iodine cyanide respectively. The titration is applied to the indirect determination of vanadium(V). In the second method ascorbic acid is treated with excess ferric solution and the ferrous iron formed is determined colorimetrically by ortho-phenanthroline.
Zusammenfassung Zwei Verfahren zur Ascorbinsäurebestimmung werden beschrieben. Bei dem ersten wird in Gegenwart von KCN und Salzsäure sowie von Stärke als Indicator mit Jodatlösung titriert. Dabei werden zwei Endpunkte erhalten, die der Reduktion von Jodat zu Jodid und damit verbundener Jodbildung bzw. der Umwandlung des Jods in JCN entsprechen. Diese Titration wird auch zur indirekten Bestimmung von Vanadium(V) verwendet. Bei dem zweiten Verfahren wird die Ascorbinsäure mit überschüssiger Eisen(III)-lösung behandelt und das gebildete zweiwertige Eisen colorimetrisch mit o-Phenanthrolin bestimmt.
  相似文献   

3.
Summary A combined anion-exchange-spectrophotometric method has been worked out for the determination of titanium in biological materials. The sample is dry-ashed at 420°C. The ash (ca. 0.5 g) is then decomposed with a mixture of nitric, perchloric and hydrofluoric acids, and is finally taken up in hydrochloric acid. The titanium is collected by anion-exchange on an Amberlite CG 400 (SCN) column from 1 M thiocyanate — 1 M hydrochloric acid solution and eluted with 4 M hydrochloric acid. Titanium is subsequently determined spectrophotometrically with diantipyrylmethane. Results of the determination of titanium in various materials of biological origin and in two NBS standard biological samples are compiled. Standard deviations are in the range of 3–9% (2.4% in synthetic mixtures).
Spurenbestimmung von Titan in biologischem Material durch Kombination von Anionenaustauscher-Trennung und Spektralphotometrie
Zusammenfassung Bei der vorgeschlagenen Methode wird die Probe bei 420° C trocken verascht, die Asche mit einer Mischung von Salpeter-, Perchlor- und Flußsäure aufgeschlossen und in Salzsäure aufgenommen. Titan wird dann aus 1 M Thiocyanat-Salzsäurelösung an dem Anionenaustauscher Amberlite CG 400 (SCN) adsorbiert und mit 4M Salzsäure eluiert. Danach erfolgt die spektralphotometrische Bestimmung mit Diantipyrylmethan. Das Verfahren wurde auf synthetische Gemische, verschiedenartige biologische Materialien und zwei NBS-Standardsubstanzen angewendet. Die Standardabweichungen liegen im Bereich von 3–9% (2,4% für synthetische Gemische).
  相似文献   

4.
Zusammenfassung Es werden einige Betrachtungen über die elektroanalytische Bestimmung des Zinns in Gegenwart von Eisen angestellt und die Folgerungen in Bezug auf die Bestimmung des Zinngehaltes von Weißblechen, die völlig oder fast frei von Blei sind, behandelt.Für die Ausführung dieser Bestimmung wird eine sehr einfache und rasche Methode vorgeschlagen, die auf der Behandlung des Weißbleches mit 10%iger Salzsäure und Elektrolyse in einem aliquoten Teil der erhalten Lösung nach Zusatz von Ammoniumoxalat und konz. Salzsäure beruht.  相似文献   

5.
Zusammenfassung Für salzsaure Lösungen bereits bekannte Anionenaustauschertrennungen von Zr-Nb, Zr-Mo und Mo-Tc konnten zu einer Trennung von Zr-Nb-Mo-Tc zusammengefaßt werden, deren quantitativer Verlauf nachgewiesen wurde.Durch Zusatz von Alkohol zu den salzsauren Elutionslösungen konnte ein Trennungsgang zur Isolierung von Zr, Nb, Mo, Tc und U aufgestellt werden. Die Elemente werden aus hochmolarer Salzsäure adsorbiert und durch stufenweise Elution mit gemischten Lösungsmitteln sinkender Gesamtacidität getrennt. Tc, das mit Salzsäure oder Mischungen aus Salzsäure und Alkohol nicht desorbierbar ist, wird mit Salpetersäure eluiert.Es konnte gezeigt werden, daß Te in das Trennschema zur Auftrennung von Zr, Nb, Mo, Tc und U eingefügt werden kann. Eine Trennung von Np und Zr innerhalb des Trennschemas — also durch Adsorption aus hochmolarer Salzsäure und stufenweise Elution — war wegen der Ähnlichkeit der Verteilungskoeffizienten von Np und Zr nicht möglich. Es konnte jedoch eine Vortrennung in eine kleine Np-Fraktion und eine stark mit Np verunreinigte Zr-Fraktion erreicht werden. Für die Nachtrennung von Np und Zr wurde ein bei kleinen HCl-Molaritäten gefundenes Maximum des Verteilungskoeffizienten von NpV ausgenützt, das eine Trennung beider Elemente durch Aufbringen aus 1,3 m Salzsäure auf den Anionenaustauscher ermöglicht. Zr wird nicht adsorbiert. Np bricht erst mit einer größeren Elutionsmenge 1,3 m Salzsäure durch. Da der ausgearbeitete Trennungsgang an die bereits bekannte Elution des Pu mit 12 m Salzsäure (unter Zusatz von NH2OH · HCl und NH4J) angeschlossen werden kann, war es möglich, ein Trennschema aufzustellen, das die Isolierung von Pu, Np, Zr, Nb, Mo, Tc, Te und U aus Spaltproduktlösungen gestattet.
Summary A procedure has been worked out for the total separation of Zr-Nb-Mo, and Tc by anion-exchange in hydrochloric acid solutions using known single separations of Zr-Nb, Zr-Mo, and Mo-Tc, and proved to be quantitative.Utilizing hydrochloric acid solutions containing alcohol as eluents, a method for the separation of Zr-Nb-Mo-Tc, and U has been developed. Highly concentrated hydrochloric acid solutions of these elements are added to the resin column and eluted sequentially with mixed solvents of decreasing over-all acidity. Tc is not desorbed with hydrochloric acid or mixtures of hydrochloric acid and alcohol; it is removed from the column with nitric acid. Investigations indicated that the separation of Zr-Nb-Mo-Tc-U, and Te is possible. Experiments to include Np in the sequential separation scheme developed, did not yield satisfying results because of the similarity of the elution curves of ZrIV and NpV. The eluted Zr was contaminated with Np and required further purification. Based on the measurement of the distribution coefficients of NpV in hydrochloric acid solutions, showing a maximum of adsorption at low concentrations of hydrochloric acid, a method for the separation of Zr from Np has been developed. The elements in 1.3 M HCl solution are added to the resin column; Zr is not absorbed. The elution is continued with 1.3 M HCl solution to remove Np, which is eluted only with larger volumes of this acid.Since Pu can be removed from the resin column with highly concentrated hydrochloric acid solutions prior to the other elements, the sequential separation scheme makes possible the isolation of Pu-Np-Zr-Nb-Mo-Tc-Te, and U from fission product mixtures.
  相似文献   

6.
Summary Pyrite is digested in a (3 + 1) nitric-hydrochloric acid mixture. Nitrate is removed by warming the solution after addition of sulphuric acid. Strong hydrochloric acid is added to hydride prior generation to eliminate interference from iron. The result is compared with that obtained by neutron activation analysis. Standard deviation was in the range of 1–2 ppm.
Selenbestimmung in Pyrit über das Hydrid mit Hilfe der AAS
Zusammenfassung Die Pyritprobe wird mit Salpetersäure/ Salzsäure aufgeschlossen und anschließend werden die Nitrationen durch Erhitzen mit Schwefelsäure entfernt. Zur Hydriderzeugung wird starke Salzsäure zugesetzt, um Störungen durch Eisen zu verhindern. Die Ergebnisse wurden mit denen der Neutronenaktivierung verglichen, wobei sich gute Übereinstimmung ergab. Die Standardabweichung liegt im Bereich von 1–2 ppm.
  相似文献   

7.
Summary A selective preconcentration technique for copper using the kerateine gel is described. The gel is prepared by partial oxidation of kerateine which is obtained by reducing the disulphide bonds of wool fiber. Copper is selectively adsorbed on the gel at pH 3.5. It is eluted with 3 M hydrochloric acid and is determined by atomic-absorption spectrometry. This method has been applied to the determination of copper in river water.
Selektive Anreicherung von Kupfer aus wäßriger Lösung mit Hilfe von Keratein-Gel
Zusammenfassung Ein selektives Anreicherungsverfahren für Kupfer mit Hilfe von Keratein-Gel wurde ausgearbeitet. Das Gel wird durch teilweise Oxidation von Keratein hergestellt, das aus Wollfaser durch Reduktion der Disulfidbindungen gewonnen wird. Kupfer wird bei pH 3,5 selektiv an diesem Gel adsorbiert und kann mit 3 M Salzsäure eluiert werden. Die Bestimmung erfolgt mit Hilfe der AAS. Das Verfahren kann zur Kupferbestimmung in Flußwasser angewendet werden.
  相似文献   

8.
    
Zusammenfassung Obgleich die Bestimmung von Kalium mit Tetraphenylbornatrium in Mischdüngern — nach Maskierung des Ammoniaks mit Formaldehyd und anderer störender Stoffe mit Komplexon — elegant und schnell ausgeführt werden kann, wurde wegen der hohen Kosten des Reagenses versucht, die Kalibestimmung mit Überchlorsäure zu verbessern.Nach einem Studium der in verschiedenen Ländern für diese Mischdünger verwendeten Methoden, wurde ein Verfahren entwickelt, in dem nach Auslaugen des Musters mit Wasser das Sulfat mittels eines Kationenaustauschers entfernt wird. Die vom Austauscher gebundenen Kalium- und Ammonium-Ionen werden nachher durch Salzsäure aus der Säule gewaschen; im sauren Durchlauf wird das Ammoniak durch Behandlung mit Natriumhydrogencarbonat entfernt und die Kalimenge mit Überchlorsäure bestimmt.Die Kaliumbestimmung in Mischdüngern kann in Gegenwart von Harnstoff ausgeführt werden. Bei Anwendung auf Patentkali und schwefelsaures Kali kann eine Vereinfachung durchgeführt werden.  相似文献   

9.
F. Licci 《Mikrochimica acta》1977,67(1-2):37-46
Summary A sensitive and accurate method is described for determining microgram amounts of ferrous iron associated with a large excess of ferric iron and various bivalent cations, in hexagonal ferrites. Ferrous iron is complexed with bathophenanthroline, extracted into a chloroform-ethanol mixture and spectrophotometrically measured at 540 nm against a 13 v/v chloroform-ethanol mixture. Ferric iron is masked with ammonium dihydrogen phosphate. The analytical conditions are stated for determination of iron(II) in both solvents used for ferrites, viz., hydrochloric and phosphoric acids. Cobalt, copper, and nickel do not interfere if the procedures suggested are used. Ferrous iron down to 0.02% can be determined in samples weighing only a few milligrams.
Zusammenfassung Eine empfindliche und genaue Methode zur Bestimmung von Mikrogrammengen Eisen(II) in Gegenwart eines großen Überschusses von Eisen(III) und verschiedener zweiwertiger Kationen in hexagonalen Ferriten wurde beschrieben. Eisen(II) wird mit Bathophenanthrolin komplex gebunden, mit einer Chloroform-Äthanol-Mischung extrahiert und bei 540 nm gegen eine Chloroform-Äthanol-Mischung (13 v/v) spektrophotometrisch gemessen. Eisen(III) wird mit NH4 · H2PO4 maskiert. Die Arbeitsbedingungen für die Bestimmung von Eisen(II) in beiden für Ferrite verwendeten Lösungsmitteln — Salzsäure und Phosphorsäure — wurden festgelegt. Co, Cu und Ni stören die empfohlenen Verfahren nicht. Bis zu 0,02% Eisen(II) können in Einwaagen von wenigen Milligramm bestimmt werden.
  相似文献   

10.
Summary Flow injection analysis is proposed using the reaction of the sample with a buffer solution containing an indicator. Acetic acid-acetate pH-buffer containing methyl red and nitrilotriacetic acid-magnesium buffer containing calmagite were employed as carrier solutions for the analysis of acids and bases or for chelatometric analysis, respectively. Successful determinations of hydrochloric acid, ammonia, magnesium and calcium and their mixtures are presented, as examples of the proposed method.
Fließinjektionsanalyse mit Säure-Basenoder Metall-Ligand-Puffern und Farbindicatoren
Zusammenfassung Für die Fließinjektionsanalyse wird ein Verfahren vorgeschlagen, bei dem die Probe mit einer Indicator-haltigen Pufferlösung reagiert. Für die Säure/Base-Analyse wird ein Essigsäure/Acetat-Puffer mit Methylrot und für die chelatometrische Analyse ein Nitrilotriessigsäure/ Magnesium-Puffer mit Camalgit verwendet. Als Anwendungsbeispiele werden Bestimmungen von Salzsäure, Ammoniak sowie Magnesium und Calcium und ihren Gemischen beschrieben.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号