共查询到20条相似文献,搜索用时 0 毫秒
1.
This paper deals with the global reduction of axial flow fan noise in ducts in a building using a hybrid passive-active noise control method. The effectiveness of using an infra-red device as a reference signal source is also investigated. It is shown that using such a hybrid noise control system over an axial-flow fan reduces the overall sound pressure level by 5 dB(A) in the surrounding environment and global control of the blade passing frequency can also be achieved. This paper also shows that using an infra-red device as a reference signal source produces marginally better control as compared with using a microphone reference sensor. Moreover, long term stability is guaranteed and the possibility of acoustic feedback is eliminated. 相似文献
2.
3.
4.
5.
In the adaptive feedback active noise control system based on the internal model control (IMC) structure, the reference signal is regenerated by synthesizing the error signal and the secondary signal filtered with the estimation of the secondary path, hence more computation load and extra programming are required. Motivated by the engineering truth that the primary noise cannot be completely cancelled in most practical active noise control applications and the error signal still contains some portions of the primary noise, a simplified adaptive feedback active noise control system is proposed in this paper, which adopts the error signal directly as the reference signal in an adaptive feedforward control system and utilizes the leaky filtered-x LMS algorithm to update the controller. The convergence properties of the proposed system are investigated and its advantages are discussed by comparing with other feedback control systems as well as the weakness. Finally, simulations and experiments are carried out to demonstrate the effectiveness of the proposed system. 相似文献
6.
Active noise control (ANC) systems employing adaptive filters suffer from stability issues in the presence of impulsive noise. New impulsive noise control algorithms based on filtered-x recursive least square (FxRLS) algorithm are presented. The FxRLS algorithm gives better convergence than the filtered-x least mean square (FxLMS) algorithm and its variants but lacks robustness in the presence of high impulsive noise. In order to improve the robustness of FxRLS algorithm for ANC of impulsive noise, two modifications are suggested. First proposed modification clips the reference and error signals while, the second modification incorporates energy of the error signal in the gain of FxRLS (MGFxRLS) algorithm. The results demonstrate improved stability and robustness of proposed modifications in the FxRLS algorithm. However, another limitation associated with the FxRLS algorithm is its computationally complex nature. In order to reduce the computational load, a hybrid algorithm based on proposed MGFxRLS and normalized step size FxLMS (NSS-FXLMS) is also developed in this paper. The proposed hybrid algorithm combines the stability of NSS-FxLMS algorithm with the fast convergence speed of the proposed MGFxRLS algorithm. The results of the proposed hybrid algorithm prove that its convergence speed is faster than that of NSS-FxLMS algorithm with computational complexity lesser than that of FxRLS algorithm. 相似文献
7.
The purpose of this work is to study computationally the possibility of the application of a hybrid active noise control technique for magnetic resonance imaging (MRI) acoustic noise reduction. A hybrid control system combined with both feedforward and feedback loops embedded is proposed for potential application on active MRI noise reduction. A set of computational simulation studies were performed. Sets of MRI acoustic noise emissions measured at the patient's left ear location were recorded and used in the simulation study. By comparing three different control systems, namely, the feedback, the feedforward and the hybrid control, our results revealed that the hybrid control system is the most effective. The hybrid control system achieved approximately a 20-dB reduction at the principal frequency component. We concluded that the proposed hybrid active control scheme could have a potential application for MRI scanner noise reduction. 相似文献
8.
9.
Based on the analysis of active noise control system with multi-channel monopole secondary sources, a kind of compound secondary source is proposed in this paper. The proposed compound secondary source consists of two closely located monopole sources with their distance much smaller than a wavelength. The characteristics of the compound source are analyzed, and the performances of the active noise control system with the compound secondary sources on the monopole primary sound field and sound radiated by a plate are investigated both numerically and experimentally. It has been found that the proposed compound secondary sources control system can provide higher noise reduction for free field noise radiation control with the same number of control channels. It is shown that the better performance in noise reduction of the compound secondary sources control system is mainly due to the directivity of the secondary sources where the energy radiation pattern of the compound sources is similar to that of the primary sources. 相似文献
10.
11.
12.
13.
This paper presents passive and active vibro-acoustic noise control methods for attenuating the interior noise level in box structures which can be an analogy of cabins of vehicle and aircraft. The structural intensity (SI) approach is adopted to identify the predominant vibration panels and interior noise sources for box structures. In the study, the finite element method is used to determine the structural vibration and structural intensity in the box surfaces. According to structural intensity vectors plot and structural intensity stream lines presentation, the possible effective control positions where the dampers may be attached and the active control forces may act to reduce vibration and interior noise, are identified. From the study, it can be demonstrated that the structural intensity approach and stream line presentation are possible methods for identifying the vibro-acoustic interior noise source and predominant panels which may be modified to reduce the interior noise level. The structural intensity methodology, passive and active noise control results can be extended to the further study of the vibration and interior noise control of actual cabins of vehicles and aircraft. 相似文献
14.
Jing Yuan 《Applied Acoustics》2007,68(1):86-96
Feedforward controllers are used in many active noise control (ANC) systems to generate destructive interference in noise fields. An ideal feedforward ANC controller should have an infinite impulse response (IIR) transfer function, but most available feedforward ANC controllers have finite impulse responses (FIR) instead. The main reason is related to the adaptation algorithms of ANC systems. In general, adaptive FIR filters converge faster with guaranteed stability. In this study, the adaptive Laguerre filter is proposed and tested in an ANC application with positive experimental effects. The new ANC controller is an IIR filter, but its adaptation is similar to that of a FIR filter with fast convergence and guaranteed stability. Detailed explanations and analysis are presented in the main text. 相似文献
15.
16.
17.
18.
19.
Tonal noise emitted from large-diameter spray dryer exhaust stacks used in the dairy industry can give rise to complaints from nearby communities. In many cases, the tone at the fan blade passing frequency is characterized by a frequency above the first mode cut on frequency of the exhaust stack and both its amplitude and the frequency are time varying. The variation in amplitude is a result of turbulence and temperature variations in the duct which cause angular variations in the nodal plane of modes with diametrical nodes. This in turn results in large fluctuations in sound pressure with time at any specified location in the duct, thus presenting a significant challenge for an ANC system with fixed control source and error sensor locations. In many food processing industries, the use of sound absorptive materials in silencers is not acceptable and, particularly when the fan speed is variable, it is difficult to achieve an acceptable passive solution at a reasonable cost. Here, the design and implementation of an active noise control system for tonal noise propagating above the cut-on frequency of the first higher order mode in large size cylindrical industrial exhaust stack is discussed, where the frequency and amplitude vary significantly and relatively rapidly with time. Physical system design principles and control algorithm optimization for a practical active noise control system are presented. Finally, real time control results which were achieved by a prototype installation on a large-diameter, in-service exhaust stack are given. Significant noise reductions were achieved in the community. 相似文献
20.
Francesco Borchi Monica Carfagni Lorenzo Martelli Alessio Turchi Fabrizio Argenti 《Applied Acoustics》2016
Active noise control (ANC) techniques are based on the emission of an antiphase signal in order to cancel the noise produced by a primary source. ANC has been successfully applied especially for reducing noise in confined environments, such as headphones and ducts. In this study, we present an application of ANC concepts to the design of an anti-noise barrier for an outdoor environment and its experimental testing. Even though passive techniques are effective in noise reduction at middle-high frequencies, they become less efficient at low frequencies (below 300 Hz) due to the limited dimensions of commonly deployable barriers. In this paper, we analyze the properties of a low-cost active noise system able to efficiently operate on stationary, almost pure-tone, low-frequency noise, such as that produced by electrical transformers and reactors in power and transformation plants. A prototype has been implemented and on-the-field experimental tests have been carried out. The results (confirmed also by numerical simulations) demonstrate a remarkable efficiency in the far field, with a reduction up to 15 dB with respect to the absence of the ANC system. 相似文献