 共查询到20条相似文献,搜索用时 31 毫秒
1.
The Planar electrostatic ion trap expands the trapping space of the linear electrostatic ion trap, giving rise to higher tolerance to space charge. A rotational symmetrical design was made, which has a trapping field between two layers of concentric circular electrodes, and the ions are trapped to oscillate around the center plane between the electrodes. The oscillatory motions of the ions were simulated and the field distribution was optimized to achieve isochronous motion against energy spread in R, z, and φ directions. The image charge signal can be picked up by more than one circular electrode and using FFT the mass resolution for the optimized trap can reach 80,000 FWHM. While Fourier transform of the image charge signal generates many high harmonic peaks, the unwanted harmonic peaks can be eliminated by linear combination of image charge signals from multiple pick-up electrodes to give satisfactory results.   相似文献   

2.
An asymmetric trapping field was generated from an asymmetric half-round rod electrode linear ion trap (A-HreLIT), and its performance of unidirectional ion ejection was studied. Two different asymmetric structures of A-HreLITs were constructed, one rotating y electrode pairs toward an x electrode with an angle θ, and the other stretching one x electrode with a distance α. The center of trapping field was displaced away from the geometrical center of the ion trap, defined to be the midpoint along the axis of y between x electrodes, which leads to unidirectional ion ejection through one x electrode. Computer simulations were used to investigate the relationship between asymmetric geometric parameter of θ (or α) and analytical performance. Both structures could result in similar asymmetric trapping fields, which mainly composed of dipole, quadrupole, and hexapole fields. The dipole and hexapole fields were approximately proportional to the asymmetric geometric parameter of rotation angle θ (or stretch distance α). In simulation, ion trajectories and ion kinetic energy were calculated. For ions with m/z 609 Th, the simulation results showed that mass resolution of over 2400 (FWHM) and ion unidirectional ejection efficiency of nearly 90% were achieved in an optimized A-HreLIT. Ion detection efficiency of A-HreLIT could be improved significantly with only one ion detector, while maintaining a considerable mass resolution. Furthermore, the A-HreLIT could be driven by a traditional balanced RF power supply. These advantages make A-HreLIT suitable for developing miniaturized mass spectrometer with high performance.
Graphical Abstract ?
  相似文献   

3.
An orbital ion trap mass analyzer employing hybrid magnetic-electric field was designed and simulated. The trap has a rotational symmetrical structure and the hybrid trapping field was created in a toroidal space between 12 pairs of sector detection electrodes. Ion injection and ion orbital motion inside the trap were simulated using SIMION 8.1 with a user Lua program, and the required electric and magnetic field were investigated. The image charge signal can be picked up by the 12 pairs of detection electrodes and the mass resolution was evaluated using FFT. The simulated resolving power for the optimized configuration over 79,000 FWHM was obtained at the magnetic induction intensity of 0.5 Tesla in the simulation.
Graphical Abstract ?
  相似文献   

4.
A new, variable-temperature mass spectrometer system is described. By applying polyimide heating tape to the end-cap electrodes of a Bruker (Bremen, Germany) Esquire ion trap, it is possible to vary the effective temperature of the system between 40 and 100°C. The modification does not impact the operation of the ion trap and the heater can be used for extended periods without degradation of the system. The accuracy of the ion trap temperatures was assessed by examining two gas-phase equilibrium processes with known thermochemistry. In each case, the variable-temperature ion trap provided data that were in good accord with literature data, indicating the effective temperature in the ion trap environment was being successfully modulated by the changes in the set-point temperatures on the end-cap electrodes. The new design offers a convenient and effective way to convert commercial ion trap mass spectrometers into variable-temperature instruments.
Graphical Abstract ?
  相似文献   

5.
We present the first coupling of laser spray ionization inlet (LSII) and matrix assisted ionization inlet (MAII) to high-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) for generation of electrospray-like ions to take advantage of increased sensitivity, mass range, and mass resolving power afforded by multiple charging. We apply the technique to top-down protein analysis and characterization of metalloproteins. We also present a novel method for generation of multiply-charged copper–peptide complexes with varying degrees of copper adduction by LSII. We show an application of the generated copper–peptide complexes for protein charge state and molecular weight determination, particularly useful for an instrument such as a linear ion trap mass analyzer.   相似文献   

6.
Collision induced dissociation (CID) is one of the most established techniques for tandem mass spectrometry analysis. The CID of mass selected ion could be realized by ion resonance excitation with a digital rectangular waveform. The method is simple, and highly efficient CID result could be obtained by optimizing the experimental parameters, such as digital waveform voltage, frequency, and q value. In this work, the relationship between ion trapping waveform voltage and frequency at preselected q value, the relationship between waveform frequency and the q value at certain ion trapping voltage for optimum CID efficiency were investigated. Experiment results showed that the max CID efficiency of precursor reserpine ions can be obtained at different trapping waveform voltage and frequency when q and β are different. Based on systematic experimental analysis, the optimum experimental conditions for high CID efficiency can be calculated at any selected β or q. By using digital ion trap technology, the CID process and efficient fragmentation of parent ions can be realized by simply changing the trapping waveform amplitude, frequency, and the β values in the digital ion trap mass spectrometry. The technology and method are simple. It has potential use in ion trap mass spectrometry.
Graphical Abstract ?
  相似文献   

7.
Space charge effects play important roles in ion trap operations, which typically limit the ion trapping capacity, dynamic range, mass accuracy, and resolving power of a quadrupole ion trap. In this study, a rhombic ion excitation and ejection method was proposed to minimize space charge effects in a linear ion trap. Instead of applying a single dipolar AC excitation signal, two dipolar AC excitation signals with the same frequency and amplitude but 90° phase difference were applied in the x- and y-directions of the linear ion trap, respectively. As a result, mass selective excited ions would circle around the ion cloud located at the center of the ion trap, rather than go through the ion cloud. In this work, excited ions were then axially ejected and detected, but this rhombic ion excitation method could also be applied to linear ion traps with ion radial ejection capabilities. Experiments show that space charge induced mass resolution degradation and mass shift could be alleviated with this method. For the experimental conditions in this work, space charge induced mass shift could be decreased by ~50%, and the mass resolving power could be improved by ~2 times at the same time.
Graphical Abstract ?
  相似文献   

8.
We have investigated the photoionization and photofragmentation yields of gas-phase multiply protonated melittin cations for photon energies at the K-shell absorption edges of carbon, nitrogen, and oxygen. Two similar experimental approaches were employed. In both experiments, mass selected [melittin+qH]q+ (q=2–4) ions were accumulated in radiofrequency ion traps. The trap content was exposed to intense beams of monochromatic soft X-ray photons from synchrotron beamlines and photoproducts were analyzed by means of time-of-flight mass spectrometry. Mass spectra were recorded for fixed photon energies, and partial ion yield spectra were recorded as a function of photon energy. The combination of mass spectrometry and soft X-ray spectroscopy allows for a direct correlation of protein electronic structure with various photoionization channels. Non-dissociative single and double ionization are used as a reference. The contribution of both channels to various backbone scission channels is quantified and related to activation energies and protonation sites. Soft X-ray absorption mass spectrometry combines fast energy deposition with single and double ionization and could complement established activation techniques.
Graphical Abstract ?
  相似文献   

9.
Secular frequency scanning is implemented and characterized using both a benchtop linear ion trap and a miniature rectilinear ion trap mass spectrometer. Separation of tetraalkylammonium ions and those from a mass calibration mixture and from a pesticide mixture is demonstrated with peak widths approaching unit resolution for optimized conditions using the benchtop ion trap. The effects on the spectra of ion trap operating parameters, including waveform amplitude, scan direction, scan rate, and pressure are explored, and peaks at black holes corresponding to nonlinear (higher-order field) resonance points are investigated. Reverse frequency sweeps (increasing mass) on the Mini 12 are shown to result in significantly higher ion ejection efficiency and superior resolution than forward frequency sweeps that decrement mass. This result is accounted for by the asymmetry in ion energy absorption profiles as a function of AC frequency and the shift in ion secular frequency at higher amplitudes in the trap due to higher order fields. We also found that use of higher AC amplitudes in forward frequency sweeps biases ions toward ejection at points of higher order parametric resonance, despite using only dipolar excitation. Higher AC amplitudes also increase peak width and decrease sensitivity in both forward and reverse frequency sweeps. Higher sensitivity and resolution were obtained at higher trap pressures in the secular frequency scan, in contrast to conventional resonance ejection scans, which showed the opposite trend in resolution on the Mini 12. Mass range is shown to be naturally extended in secular frequency scanning when ejecting ions by sweeping the AC waveform through low frequencies, a method which is similar, but arguably superior, to the more usual method of mass range extension using low q resonance ejection.
Graphical Abstract ?
  相似文献   

10.
A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (>?300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (>?300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MSn), as well as the cross sections of ions measured using CDMS.
Graphical Abstract
  相似文献   

11.
The performance of miniaturized ion trap mass analyzers is limited, in part, by the accuracy with which electrodes can be fabricated and positioned relative to each other. Alignment of plates in a two-plate planar LIT is ideal to characterize misalignment effects, as it represents the simplest possible case, having only six degrees of freedom (DOF) (three translational and three rotational). High-precision motorized actuators were used to vary the alignment between the two ion trap plates in five DOFs—x, y, z, pitch, and yaw. A comparison between the experiment and previous simulations shows reasonable agreement. Pitch, or the degree to which the plates are parallel along the axial direction, has the largest and sharpest impact to resolving power, with resolving power dropping noticeably with pitch misalignment of a fraction of a degree. Lateral displacement (x) and yaw (rotation of one plate, but plates remain parallel) both have a strong impact on ion ejection efficiency, but little effect on resolving power. The effects of plate spacing (y-displacement) on both resolving power and ion ejection efficiency are attributable to higher-order terms in the trapping field. Varying the DC (axial) trapping potential can elucidate the effects where more misalignments in more than one DOF affect performance. Implications of these results for miniaturized ion traps are discussed.
Graphical Abstract ?
  相似文献   

12.
离子阱阵列的理论模拟研究   总被引:1,自引:0,他引:1  
罗婵  丁传凡 《分析化学》2012,40(7):989-995
采用电脑模拟的方法对一种新型的离子阱质量分析器——离子阱阵列进行了电极结构的优化.该离子阱质量分析器为一种多通道质量分析器,可以同时对不同的离子进行储存和质量分析.本实验主要研究了该离子阱质量分析器的性能和电极结构之间的关系.通过对离子运动轨迹的计算分析,可以得到模拟的离子质谱峰.通过对模拟离子质谱峰的分析,可以区分出使得离子阱性能较优的电极结构.在对模拟质谱峰的分析中,峰形和离子弹出效率都作为性能指标被考虑.有部分模拟的数据与实验结果进行了对比.  相似文献   

13.
We present a new two-plate linear ion trap mass spectrometer that overcomes both performance-based and miniaturization-related issues with prior designs. Borosilicate glass substrates are patterned with aluminum electrodes on one side and wire-bonded to printed circuit boards. Ions are trapped in the space between two such plates. Tapered ejection slits in each glass plate eliminate issues with charge build-up within the ejection slit and with blocking of ions that are ejected at off-nominal angles. The tapered slit allows miniaturization of the trap features (electrode size, slit width) needed for further reduction of trap size while allowing the use of substrates that are still thick enough to provide ruggedness during handling, assembly, and in-field applications. Plate spacing was optimized during operation using a motorized translation stage. A scan rate of 2300 Th/s with a sample mixture of toluene and deuterated toluene (D8) and xylenes (a mixture of o-, m-, p-) showed narrowest peak widths of 0.33 Th (FWHM).
Graphical Abstract ?
  相似文献   

14.
Ozone-induced dissociation (OzID) is an alternative ion activation method that relies on the gas phase ion-molecule reaction between a mass-selected target ion and ozone in an ion trap mass spectrometer. Herein, we evaluated the performance of OzID for both the structural elucidation and selective detection of conjugated carbon-carbon double bond motifs within lipids. The relative reactivity trends for [M + X]+ ions (where X = Li, Na, K) formed via electrospray ionization (ESI) of conjugated versus nonconjugated fatty acid methyl esters (FAMEs) were examined using two different OzID-enabled linear ion-trap mass spectrometers. Compared with nonconjugated analogues, FAMEs derived from conjugated linoleic acids were found to react up to 200 times faster and to yield characteristic radical cations. The significantly enhanced reactivity of conjugated isomers means that OzID product ions can be observed without invoking a reaction delay in the experimental sequence (i.e., trapping of ions in the presence of ozone is not required). This possibility has been exploited to undertake neutral-loss scans on a triple quadrupole mass spectrometer targeting characteristic OzID transitions. Such analyses reveal the presence of conjugated double bonds in lipids extracted from selected foodstuffs. Finally, by benchmarking of the absolute ozone concentration inside the ion trap, second order rate constants for the gas phase reactions between unsaturated organic ions and ozone were obtained. These results demonstrate a significant influence of the adducting metal on reaction rate constants in the fashion Li > Na > K.   相似文献   

15.
Electron transfer dissociation (ETD) is commonly employed in ion traps utilizing rf fields that facilitate efficient electron transfer reactions. Here, we explore performing ETD in the HCD collision cell on an Orbitrap Velos instrument by applying a static DC gradient axially to the rods. This gradient enables simultaneous three dimensional, charge sign independent, trapping of cations and anions, initiating electron transfer reactions in the center of the HCD cell where oppositely charged ions clouds overlap. Here, we evaluate this mode of operation for a number of tryptic peptide populations and the top-down sequence analysis of ubiquitin. Our preliminary data show that performing ETD in the HCD cell provides similar fragmentation as ion trap-ETD but requires further optimization to match performance of ion trap-ETD.   相似文献   

16.
A mesh-electrode linear ion trap (ME-LIT) mass analyzer was developed and its performance was primarily characterized. In conventional linear ion trap mass analyzers, the trapped ions are mass-selected and then ejected in a radial direction by a slot on a trap electrode. The presence of slots can strongly affect the electric field distribution in the ion trapping region and distort the mass analysis performance. To compensate for detrimental electric field effects, the slot is usually designed and fabricated to be as small as possible, and also has very high mechanical accuracy and symmetry. A ME-LIT with several mesh electrodes was built to compensate for the effects caused by slots. Each mesh electrode was fabricated from a plate electrode with a relatively large slot and the slot was covered with a conductive mesh. Our preliminary experimental results show that the ME-LIT could considerably diminish the detrimental electric field effects caused by slots, and increase the mass resolving power and ion detection efficiency. Even with 4-mm-wide slots, a mass resolution in excess of 600 was obtained using the ME-LIT. Mass resolution could be remarkably improved using mesh electrodes in ion traps with asymmetric electrodes. The stability diagram of the ME-LIT was mapped, and highly efficient tandem mass spectrometry was demonstrated. The ME-LIT was qualified as a LIT mass analyzer. The ME-LIT can improve the mass resolution and decrease the requirements of mechanical accuracy and symmetry of slots, so it shows potential for a wide range of practical uses.
Figure
?  相似文献   

17.
Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolution on the LTQ is better than unit at scan speeds of ~?400 Th/s, whereas peak widths on the Mini 12, on average, range from 0.5 to 2.0 Th full width at half maximum and depend heavily on the precursor ion Mathieu q parameter as well as the pump down time that precedes the mass scan. Both sensitivity and resolution are maximized under higher pressure conditions (short pump down time) on the Mini 12. The effective mass range of the product ion ejection waveform was found to be 5.8 Th on the Mini 12 in the precursor ion scan mode vs. that of 3.9 Th on the LTQ. In the neutral loss scan mode, the product ion selectivity was between 8 and 11 Th on the Mini 12 and between 7 and 8 Th on the LTQ. The effects of nonlinear resonance lines on the Mini 12 were also explored.
Graphical Abstract ?
  相似文献   

18.
Targeted multiplex imaging mass spectrometry utilizes several different antigen-specific primary antibodies, each directly labeled with a unique photocleavable mass tag, to detect multiple antigens in a single tissue section. Each photocleavable mass tag bound to an antibody has a unique molecular weight and can be readily ionized by laser desorption ionization mass spectrometry. This article describes a mass spectrometry method that allows imaging of targeted single cells within tissue using transmission geometry laser desorption ionization mass spectrometry. Transmission geometry focuses the laser beam on the back side of the tissue placed on a glass slide, providing a 2 μm diameter laser spot irradiating the biological specimen. This matrix-free method enables simultaneous localization at the sub-cellular level of multiple antigens using specific tagged antibodies. We have used this technology to visualize the co-expression of synaptophysin and two major hormones peptides, insulin and somatostatin, in duplex assays in beta and delta cells contained in a human pancreatic islet.   相似文献   

19.
In this article, we investigated the nonlinear resonance effect in the Paul trap with a superimposed hexapole field, which was assumed as a perturbation to the quadrupole field. On the basis of the Poincare-Lighthill-Kuo (PLK) perturbation method, ion motional equation, known as nonlinear Mathieu equation (NME) was expressed as the addition of approximation equations in terms of perturbation order. We discussed the frequency characteristics of ion axial-radial (z-r) coupled motion in the nonlinear field, derived the expressions of ion trajectories and nonlinear resonance conditions, and found that the mechanism of nonlinear resonance is similar to the normal resonance. The frequency spectrum of ion motion in nonlinear field includes not only the natural frequency series but also nonlinear introduced frequency series, which provide the driving force for the nonlinear resonance. The nonlinear field and the nonlinear effects are inevitable in practical ion trap experiments. Our method provides better understanding of these nonlinear effects and would be helpful for the instrumentation for ion trap mass spectrometers.   相似文献   

20.
We reported the use of ion mobility (IM) combined with mass spectrometry (MS) as an analytical tool to investigate low generation polyamidoanine (PAMAM) dendrimers. This analytical approach has been employed to separate ions of defective structures with different charge state but exactly the same m/z value. Tandem mass spectrometry (MS/MS) after IM separation allowed a comprehensive structural characterization of defective dendrimers. In addition, IM was used to evaluate the collision cross-sections of ions of perfect dendrimers. They showed a good correlation with calculated collision cross-sections obtained by the trajectory method (TM) and were also consistent with dimensions reported by other established analytical methods.   相似文献   