首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple and rapid normal‐phase HPLC method for enantiospecific separation of a psychostimulant, adrafinil (ADL), and its metabolite modafinil (MDL) in rat serum and urine was developed. The separation was accomplished on a normal‐phase polysaccharide stationary phase Chiralcel OJ‐H using n‐hexane–ethanol (62:38 v/v) as a mobile phase at a flow rate of 1.0 mL/min. Detection was carried out at 225 nm using a photo diode array (PDA) detector. The elution order of the enantiomers was determined by a polarimeter connected in series with the PDA. ADL and its metabolite were recovered from rat serum and urine by solid phase extraction using Oasis HLB cartridges and the mean recoveries were ≥80%. The enantiomers were eluted within 15 min without any interference from endogenous substances. The calibration curves were linear (r2 > 0.998) in the concentration range of 1.20–500 µg/mL for ADL and MDL. The assay was specific, accurate, precise and reproducible (intra‐ and inter‐day precisions RSDs <7.2%). ADL in rat serum was stable over three freeze–thaw cycles at ambient temperature for 4 h. The method was successfully applied to pharmacokinetic studies of adrafinil after an oral administration to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A simple stereoselective high performance liquid chromatographic method was developed for the determination of the in vitro transport of the enantiomers of nateglinide (N-(trans-4-isopropylcyclohexyl-carbonyl)-phenylalanine) in the rat intestine using a Chiralcel OJ-RH column (150 x 4.0 mm, 5 microm). The effects of the mobile phase composition, pH, the flow rate, and the temperature on the chromatographic separation were investigated. The enantioseparation was achieved at 33 degrees C using a mobile phase containing 100 mM potassium dihydrogen phosphate, pH 2.5, and ACN (32:68 v/v) delivered at a flow rate of 1 mL/min. The analytes were monitored at 210 nm and linearity (r >0.99) was obtained for a concentration range of 0.5-50 microg/mL. The LOD and LOQ were 0.2 and 0.5 microg/mL for the R-enantiomer and 0.2 and 0.8 microg/mL for the S-enantiomer, respectively. Both, the intra- and interday accuracy and precision of the calibration curves were determined. The method was successfully applied to estimate the in vitro passage of the enantiomers and the racemate of nateglinide in duodenum, jejunum, and ileum of rats. Generally, higher concentrations of nateglinide and the S-enantiomer were observed when the racemate was administered compared to administration of the individual enantiomers of nateglinide.  相似文献   

3.
A capillary electrophoresis method using CDs for quality control of esomeprazole (ESO) in terms of enantiomeric purity and related substances in raw material and pellets was developed. ESO is the S‐enantiomer of omeprazole (OMZ). Several parameters were evaluated, including type and concentration of buffer and CD, concentration of additives and electrolyte pH. Resolution between the enantiomers of OMZ obtained for each parameter tested was calculated and the presence of the main related substance such as OMZ sulfone was carefully monitored. The optimized system consisted of 100 mM Tris‐phosphate buffer pH 2.5 with 20 mM 2‐hydroxypropyl‐β‐CD, 1 mM sodium dithionite, temperature at 15°C, voltage at 28 kV, and UV detection at 301 nm. Once optimized, the electrophoretic system was validated according to ICH guidelines. The limits of detection and quantification for R‐OMZ were 0.6 μg/mL (0.06% w/w of ESO) and 2.0 μg/mL (0.2% w/w of ESO), respectively. A mean concentration of R‐OMZ <0.2% limit established by the United States Pharmacopeia (USP) was found in the raw material and six‐pellet samples of ESO. No other impurities were found in the samples under these conditions. Therefore, the developed method was found to be appropriate not only for enantiomeric quality control of ESO but also for the analysis of ESO and the main related substance in raw material and pharmaceutical formulations as well as for stability indicating studies.  相似文献   

4.
A direct, isocratic, sensitive and precise liquid chromatographic method is presented for the enantiomeric separation of aminoglutethimide (AG) and its acetylated metabolite (AcAG) using cellulose tris-3,5-dimethyl phenyl carbamate (Chiralcel OD) and cellulose tris(4-methylphenyl benzoate) ester (Chiralcel OJ) columns in series. The enantiomeric elution order is determined by separate chromatography of the racemate AG and racemate AcAG and of their separate enantiomers under similar conditions. This method has been used to determine and identify the enantiomers of AG and AcAG in the urine sample collected from a metastatic breast cancer patient after administration of AG for 24 h. Large amounts of (+)-R-AG are excreted unchanged in the urine together with smaller quantities of (+)-R-AcAG, while most of the (-)-S-AG is metabolically converted into (-)-S-AcAG.  相似文献   

5.
A simple reversed‐phase high‐performance liquid chromatography method for the chiral separation of the active pharmaceutical ingredient (S)‐clopidogrel has been developed on the cellulose‐based Chiralcel OJ‐RH chiral stationary phase. The S enantiomer was baseline resolved from its R impurity (impurity C) with a mobile phase consisting of methanol/water (100:15) without any interference coming from the other two potential chiral impurities A and B. The enantio‐ and chemoselective method was partially validated and compared with that reported in the United States Pharmacopoeia for the drug product. The versatility of the Chiralcel OJ‐RH allowed separating the enantiomers of the impurity B also under normal phase and setting up an efficient strategy to convert the racemic sample into the enantiomeric S form on a semipreparative scale.  相似文献   

6.
The enantiomers of vildagliptin, an orally available and selective dipeptidyl‐peptidase‐4 inhibitor used for the treatment of type II diabetes, have been separated by CD‐modified CZE, using uncoated fused‐silica capillary. After screening 13 negatively charged CD derivatives as potential chiral selectors, sulfobutyl‐ether‐α‐CD (SBE‐α‐CD) was selected for the enantioseparation. For the optimization, a factorial analysis study was performed by orthogonal experimental design. Six experimental factors were chosen as variable parameters: temperature, applied voltage, chiral selector and BGE concentrations, pH, and the parameters of the hydrodynamic injection. The optimized system still was not considered final as the second peak (S‐enantiomer) migrated too close to the EOF, resulting in a potential inaccuracy during the determination of the chiral impurity. To fine‐tune the method “one factor at a time” variation approach was applied. The final method (applying 15°C capillary temperature, 40 mbar × 4 s hydrodynamic injection, 25 kV voltage in 75 mM acetate‐Tris buffer [pH 4.75] containing 20 mM SBE‐α‐CD as chiral selector) was validated according to the ICH guideline. RSD percentage of the resolution value, migration times, and corrected peak areas were below 5% during testing repeatability and intermediate precision. LOD and LOQ values were found to be 2.5 and 7.5 μg/mL, respectively. The method is considered linear in the 7.5–180 μg/mL range for the R‐enantiomer. The robustness of the method was justified using Plackett–Burmann statistical experimental design.  相似文献   

7.
Yanru Liu  Xia Wang  Jia Yu  Xingjie Guo 《Electrophoresis》2021,42(14-15):1461-1472
Enantiomeric separation of six antihistamine agents was first systematically investigated on a cellulose-based chiral stationary phase (CSP), that is, cellulose tris-(3,5-dimethyl phenyl carbamate) (Chiralcel OD-RH), under the reversed-phase mode. Orphenadrine, meclizine, terfenadine, dioxopromethazine, and carbinoxamine enantiomers were completely separated under the optimized mobile phase conditions with resolutions of 5.02, 1.93, 1.68, 1.67, and 1.54, respectively. Mequitazine was partially separated with a resolution of 0.77. The influences of type and concentration of buffer salt, the pH of buffer solution, and the type and ratio of organic modifier on the chiral separation were evaluated and optimized. For a better insight into the enantiorecognition mechanisms, molecular docking was carried out via the Autodock software. The lowest binding energy and the optimal conformations of the analytes/CSP complexes were supplied, and the mechanisms of chiral recognition were determined. According to the results, the key interactions for the chiral recognition of these six analytes on CDMPC were π–π interactions, hydrophobic interactions, hydrogen bond interactions, and some special interactions.  相似文献   

8.
This article presents the validation results of a chiral liquid chromatographic (LC) method previously developed for the quantitative determination of R-timolol in S-timolol maleate samples. A novel validation strategy based on the accuracy profiles was used to select the most appropriate regression model, to assess the method accuracy within well defined acceptance limits and to determine the limits of quantitation as well as the concentration range.The validation phase was completed by the investigation of the risk profiles of various acceptable regression models in order to ensure the risk of obtaining the future measurements outside the acceptance limits fixed a priori.On the other hand, the present paper also shows how data used in this validation approach can be used to estimate the measurement uncertainty. The uncertainty derived from β-expectation tolerance interval (), which is equal to the uncertainty of measurements as well as the expanded uncertainty (Ux) using a coverage factor k = 2 was estimated. The uncertainty estimates obtained from validation data were finally compared with those obtained from interlaboratory and robustness studies.  相似文献   

9.
The present study describes the development and validation of a selective liquid chromatographic (LC) method for the analysis of tenofovir disoproxil fumarate (TDF) and its related substances. The gradient method uses a base deactivated C18 column (Hypersil BDS column; 25 cm×4.6 mm I.D.) maintained at a temperature of 30°C. The mobile phases consist of acetonitrile, tetrabutylammonium/phosphate buffer pH 6.0 and water: (A; 2:20:78 v/v/v) and (B; 65:20:15 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 260 nm. Good separation of TDF and 21 impurities was achieved. A system suitability test (SST) to check the quality of separation is also specified. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. The method is proved to be robust, precise, sensitive and linear between 0.1 μg/mL and 0.15 mg/mL. The limit of detection and limit of quantification are 0.03 and 0.1 μg/mL, respectively. The method was successfully applied to the quantification of related substances and assay of commercial TDF samples (bulk substances and tablets).  相似文献   

10.
A high‐throughput liquid chromatography–electrospray ionization mass spectrometric (LC–ESI‐MS) method for screening of sirolimus on dried blood spots (DBS) was developed and validated. It involves solvent extraction of a punch of DBS followed by reversed‐phase LC on a relatively new monolithic column consisting of a silica rod with bimodal pore structure and detection by ESI‐MS. The run time was less than 3 min with a very low backpressure at a flow rate of 0.5 mL/min. The method can analyze more than 100 samples in an 8 h working day, including sample preparation. The assay was linear from 1 to 100 ng/mL. The mean recovery was 92.42%. The mean inter‐day and intra‐day precisions were 1.23 and 1.41%, respectively. The developed method is simple, rapid and useful for clinical applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
ABSTRACT: A simple reversed phase high performance liquid chromatographic method with diode array detector (HPLC-DAD) has been developed and subsequently validated for the determination of fexofenadine hydrochloride (FEX) and its related compounds; keto fexofenadine (Impurity A), meta isomer of fexofenadine (Impurity B), methyl ester of fexofenadine (Impurity C) in addition to the methyl ester of ketofexofenadine (Impurity D). The separation was based on the use of a Hypersil BDS C-18 analytical column (250 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of a mixture of phosphate buffer containing 0.1 gm% of 1-octane sulphonic acid sodium salt monohydrate and 1% (v/v) of triethylamine, pH 2.7 and methanol (60:40, v/v). The separation was carried out at ambient temperature with a flow rate of 1.5 ml/min. Quantitation was achieved with UV detection at 215 nm using lisinopril as internal standard, with linear calibration curves at concentration ranges 0.1-50 μg/ml for FEX and its related compounds. The optimized conditions were used to develop a stability-indicating HPLC-DAD method for the quantitative determination of FEX and its related compounds in tablet dosage forms. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. Complete separation was achieved for the parent compounds and all degradation products. The method was validated according to ICH guidelines in terms of accuracy, precision, robustness, limits of detection and quantitation and other aspects of analytical validation.  相似文献   

12.
A new chiral analytical method based on CE‐MS is proposed for the identification and simultaneous quantification of D /L ‐carnitine in infant formulas. Previous derivatization of carnitine with FMOC enabled the optimization of the chiral separation using CE with UV detection. An optimization of electrospray‐MS parameters using a partial filling of the non‐volatile chiral selector (succinyl‐γ‐CD) was performed. A selective fragmentation using MS2 experiments with an ion trap analyser was carried out to confirm the identity of D /L ‐carnitine according to the current legislation. Satisfactory results were obtained in terms of linearity, precision, and accuracy. Interestingly, the CE‐MS2 method developed allowed a sensitivity enhancement with respect to UV detection of 100‐fold, obtaining an LOD of 100 ng/g for D ‐carnitine. The determination of L ‐carnitine and its enantiomeric purity in 14 infant formulas supplemented with carnitine was successfully achieved, sample preparation only requiring an ultrafiltration with centrifugal filter devices to retain the components with the highest molecular weights.  相似文献   

13.
A rapid and sensitive reversed-phase high-performance liquid chromatographic method (RP-HPLC) with ultraviolet detection has been developed for the determination of moclobemide and its metabolites, p-chloro-N-(-2-morpholinoethyl)benzamide N'-oxide (Ro 12-5637) and p-chloro-N-[2-(3-oxomorpholino)ethyl]-benzamide (Ro 12-8095), in human plasma. The assay was performed after single liquid-liquid extraction with dichloromethane at alkaline pH using phenacetin as the internal standard. Chromatographic separation was performed on a C(18) column using a mixture of acetonitrile and water (25:75, v/v), adjusted to pH 2.7 with ortho-phosphoric acid, as mobile phase. Spectrophotometric detection was performed at 239 nm. The method has been validated for accuracy, precision, selectivity, linearity, recovery and stability. The quantification limit for moclobemide and Ro 12-8095 was 10 ng/mL, and for Ro 12-5637 was 30 ng/mL. Linearity of the method was confirmed for the range 20-2500 ng/mL for moclobemide (r = 0.9998), 20-1750 ng/mL for Ro 12-8095 (r = 0.9996) and 30-350 ng/mL for Ro 12-5637 (r = 0.9991). Moreover, within-day and between-day precisions and accuracies of the method were established. The described method was successfully applied in pharmacokinetic studies of parent drug and its two metabolites after a single oral administration of 150 mg of moclobemide to 20 healthy volunteers.  相似文献   

14.
A highly sensitive, specific and enantioselective assay has been developed and validated for the estimation of TAK‐700 enantiomers [(+)‐TAK‐700 and (?)‐TAK‐700] in rat plasma on LC‐MS/MS‐ESI in the positive‐ion mode. Liquid–liquid extraction was used to extract (±)‐TAK‐700 enantiomers and IS (phenacetin) from rat plasma. TAK‐700 enantiomers were separated using methanol and 5 mm ammonium acetate (80:20, v/v) at a flow rate of 0.7 mL/min on a Chiralcel OJ‐RH column. The total run time was 7.0 min and the elution of (+)‐TAK‐700, (?)‐TAK‐700 and IS occurred at 3.71, 4.45 and 4.33 min, respectively. The MS/MS ion transitions monitored were m/z 308.2 → 95.0 for TAK‐700 and m/z 180.2 → 110.1 for IS. The standard curves for TAK‐700 enantiomers were linear (r2 > 0.998) in the concentration range 2.01–2015 ng/mL for each enantiomer. The inter‐ and intra‐day precisions were in the ranges 3.74–7.61 and 2.06–8.71% and 3.59–9.00 and 2.32–11.0% for (+)‐TAK‐700 and (?)‐TAK‐700, respectively. Both the enantiomers were found to be stable in a battery of stability studies. This novel method was applied to the study of stereoselective oral pharmacokinetics of (+)‐TAK‐700 and it was unequivocally demonstrated that (+)‐TAK‐700 does not undergo chiral inversion to its antipode in vivo. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
A rapid, simple and sensitive LC‐MS/MS method for the quantification of vinflunine in plasma was developed and validated. The analysis involved a simple liquid–liquid extraction. After making alkaline with NaOH, plasma was extracted with methyl tert‐butyl ether and the organic extract was then evaporated and the residue was reconstituted in mobile phase. The reconstituted solution was injected into an HPLC system and was subjected to reverse‐phase HPLC on a 5 µm ODS‐3 column at a flow‐rate of 0.2 mL/min. The mobile phase consisted of ammonium acetate (0.02 mol/L, pH = 3.0) and acetonitrile (20:80). Vinflunine was detected in the single ion monitoring mode using target ions at m/z 817.4/160.1/142.3 for vinflunine and m/z 447.2/128.3/112.1 for gefitinib (internal standard). Standard curves were linear over the concentration range of 5–1000 ng/mL. The mean predicted concentrations of the quality control samples deviated by less than 2% from the corresponding nominal values; the intra‐assay and inter‐assay precisions of the assay were within 7% relative standard deviation. The extraction recovery of vinflunine was more than 80%. The validated assay was applied to a pharmacokinetic study of vinflunine in plasma following the administration of a single vinflunine injection (2 mg/kg). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
A simple and sensitive HPLC method was developed and validated for the determination of four frequently prescribed 1,4-benzodiazepines: alprazolam (ALP), bromazepam (BRZ), diazepam (DZP), and flunitrazepam (FNZ). Separation was achieved on an Inertsil C8 analytical (250 mm x 4 mm, 5 microm) column, after selective extraction of benzodiazepine drugs from biological matrices by means of SPE. Isocratic elution was performed with a mobile phase consisting of CH3COONH4, 0.05 M CH3OH, and CH3CN (33:57:10 by volume). Quantification was performed at 240 nm with mefenamic acid (6 ng/microL) as the internal standard. DSC-18 Supelco cartridges provided high absolute recoveries (81-115%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <12%. Recoveries from biological samples ranged from 81.2 to 115%. The detection limit of the method was calculated as 3.3-10.2 ng in blood plasma and 2.6-12.6 ng in urine for 20 microL injection volume. The method was applied to spiked biological matrices. Moreover, the method was applied to real samples of urine after an oral administration.  相似文献   

17.
An isocratic reversed-phase high-performance liquid chromatographic method has been developed for separation and simultaneous determination of COX-2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4-chloro-2-nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed-phase Inertsil C(18) column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0--20 microg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX-2 inhibitors with a detection limit of 0.127--1.040 microg/mL simultaneously.  相似文献   

18.
An MEKC method for the analysis of goserelin and related substances has been developed using a combination of additives including CTAB, β‐CD, and sodium hexanesulfonate. For this assay, the running buffer (pH and additives) and separation conditions (voltage and temperature) were optimized. The optimized system was the following: 200 mM 6‐aminocaproic acid buffer (pH 4.2) supplemented with 175 mM CTAB, 3.0% w/v β‐CD, and 20 mM sodium hexanesulfonate; the voltage was 10 kV in reverse polarity mode, the temperature was 20°C, and UV detection was measured at 220 nm. The method was qualified by evaluating the specificity, precision, linearity, accuracy, LOD, and LOQ. According to validation experiments, the optimized method was specific, accurate, and repeatable and satisfied the requirements for the analysis of goserelin and related substances. Compared with the RP‐HPLC method, the MEKC method better solved the problem of overlapping impurity signals, and the migration time required was shorter. This method can be used for quality control and for the analysis of goserelin and its related substances.  相似文献   

19.
Brazilin is a major homoisoflavonoid component isolated from the dried heartwood of traditional Chinese medicine Caesalpinia sappan L., which is a natural red pigment used for histological staining. Herein a sensitive, specific and rapid analytical LC‐MS/MS method was established and validated for brazilin in rat plasma. After a simple step of protein precipitation using acetonitrile, plasma samples were analyzed using an LC‐MS/MS system. Brazilin and the IS (protosappanin B) were separated on a Diamonsil C18 analytical column (150 × 4.6 mm, 5 µm) using a mixture of water and 10 mm ammonium acetate in methanol (20:80, v/v) as mobile phase at a flow rate of 0.6 mL/min. The method was sensitive with a lower limit of quantitation of 10.0 ng/mL, with good linearity (r2 ≥ 0.99) over the linear range 10.0–5000 ng/mL. All the validation data, such as accuracy and precision, matrix effect, extraction recovery and stability tests were within the required limits. The assay method was successfully applied to evaluate the pharmacokinetics parameters of brazilin after an oral dose of 100 mg/kg brazilin in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
An HPLC method was developed for the simultaneous determination of seven water-soluble vitamins, viz. thiamine, riboflavin, nicotinic acid, nicotinamide, pyridoxine, cyanocobalamin, and folic acid, in multivitamin pharmaceutical formulations and biological fluids (blood serum and urine). Separation was achieved at ambient temperature on a Phenomenex Luna C18 (150 x 4.6 mm) analytical column. Gradient elution was performed starting at a 99:1 A:B v/v composition, where A: 0.05 M CH3COONH4/CH3OH (99/1) and B: H2O/CH3OH (50/50), at a flow rate of 0.8 mL/min. After a 4-min isocratic elution the composition was changed to 100% of B in 18 min and elution continued isocratically for 8 min. Detection was performed with a photodiode array detector at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples. Detection limits were in the range of 1.6-3.4 ng, per 20-microL injection, while linearity held up to 25 ng/microL. Accuracy, intra-day repeatability (n = 6), and inter-day precision (n = 7) were found to be satisfactory. Theobromine (2 ng/microL) was used as internal standard. Sample preparation of biological fluids was performed by SPE on Supelclean LC-18 cartridges with methanol-water 85/15 v/v as eluent. Extraction recoveries from biological matrices ranged from 84.6% to 103.0%.  相似文献   