首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The delta(13)C(VPDB), delta(2)H(VSMOW) and delta(18)O(VSMOW) values of caffeine isolated from Arabica green coffee beans of different geographical origin have been determined by isotope ratio mass spectrometry (IRMS) using elemental analysis (EA) in the "combustion" (C) and "pyrolysis" (P) modes (EA-C/P-IRMS). In total, 45 coffee samples (20 from Central and South America, 16 from Africa, six from Indonesia, and three from Jamaica and Hawaii) were analysed, as well as three reference samples of synthetic caffeine. Validation was performed by excluding isotope discrimination in the course of sample preparation and determining linear dynamic ranges for EA-P-IRMS measurements. The values for caffeine from green coffee ranged from -25.1 to - 29.9 per thousand, -109 to -198 per thousand, and +2.0 to -12.0 per thousand for delta(13)C(VPDB), delta(2)H(VSMOW), and delta(18)O(VSMOW), respectively. Data evaluation by linear discrimination analysis (LDA) and by classification and regression tree (CART) analysis revealed the delta(18)O(VSMOW) values to be highly significant. Use of LDA on the delta(2)H(VSMOW) and delta(18)O(VSMOW) data from coffee of African and Central/South American provenance led to error rates of 5.7% and 7.7% for adaption and cross validation, respectively.  相似文献   

2.
A high-precision, and rapid on-line method for oxygen isotope analysis of silver phosphate is presented. The technique uses high-temperature elemental analyzer (EA)-pyrolysis interfaced in continuous flow (CF) mode to an isotopic ratio mass spectrometer (IRMS). Calibration curves were generated by synthesizing silver phosphate with a 13 per thousand spread in delta(18)O values. Calibration materials were obtained by reacting dissolved potassium dihydrogen phosphate (KH(2)PO(4)) with water samples of various oxygen isotope compositions at 373 K. Validity of the method was tested by comparing the on-line results with those obtained by classical off-line sample preparation and dual inlet isotope measurement. In addition, silver phosphate precipitates were prepared from a collection of biogenic apatites with known delta(18)O values ranging from 12.8 to 29.9 per thousand (V-SMOW). Reproducibility of +/- 0.2 per thousand was obtained by the EA-Py-CF-IRMS method for sample sizes in the range 400-500 microg. Both natural and synthetic samples are remarkably well correlated with conventional (18)O/(16)O determinations. Silver phosphate is a very stable material and easy to degas and, thus, could be considered as a good candidate to become a reference material for the determination of (18)O/(16)O ratios of phosphate by high-temperature pyrolysis.  相似文献   

3.
The effects of the gas chromatography flow rate on the determination of the deuterium/hydrogen (D/H) ratios of natural gas utilising gas chromatography/high-temperature conversion/isotope ratio mass spectrometry (GC/TC/IRMS) have been evaluated. In general, the measured deltaD values of methane, ethane and propane decrease with increase in column flow rate. When the column flow rate is 1 mL/min or higher, which is commonly used for the determination of D/H ratios of natural gas, the organic H in gas compounds may not be completely converted into hydrogen gas. Based on the results of experiments conducted on a GC column with an i.d. of 0.32 mm, a GC flow rate of 0.6 mL/min is proposed for determining the D/H ratios of natural gas by GC/TC/IRMS. Although this value may be dependent on the instrument conditions used in this work, we believe that correct deltaD values of organic compounds with a few carbon atoms are obtained only when relatively low GC flow rates are used for D/H analysis by GC/TC/IRMS. Moreover, as the presence of trace water could significantly affect the determination of D/H ratios, a newly designed inlet liner was used to remove trace water contained in some gas samples.  相似文献   

4.
Measurements of stable carbon isotopic composition (delta13C) of carbonates or carbonate-rich soils are seldom performed in a continuous-flow isotope ratio mass spectrometer (IRMS) using an elemental analyzer (EA) as an online sample preparation device. Such analyses are routinely carried out with an external precision better than 0.1 per thousand using a GasBench II (GB) sample preparation device coupled online with a continuous-flow IRMS. In this paper, we report and compare delta13C analyses (86 total analyses) of calcium carbonates obtained by using both the GB and the EA. Using both techniques, the delta13C compositions of two in-house carbonate standards (MERCK carbonate and NR calcite) and ten selected carbonate-rich paleosol samples (of variable CaCO3 content) were analyzed, and data are reported in the VPDB scale calibrated against international standards, NBS 18 and 19. For the in-house standards analyzed by both techniques, a precision better than 0.08 per thousand is achieved. The analytical errors (1sigma) computed from multiple analyses of the delta13C of both the MERCK and NR obtained by the above two techniques are nearly identical. In general, the 1sigma (internal error) of paleosol analyses obtained in the GB is better than 0.06 per thousand, whereas that for the analyses in the EA (three repetitive analyses of the same sample) varies in the range 0.05-0.21 per thousand. However, for paleosols having more than 85% CaCO3, 1sigma is better than 0.15 per thousand (similar to the instrument precision), and in this case the delta13C(VPDB) of samples obtained by the GB is similar to that obtained by the EA. Our results suggest that the delta13C of pure calcium carbonate samples can also be analyzed using the EA technique.  相似文献   

5.
Site-specific carbon isotope composition of organic compounds can provide useful information on their origin and history in natural environments. Site-specific isotope analyses of small amounts of organic compounds (sub-nanomolar level), such as short-chain carboxylic acids and amino acid analogues, have been performed using gas chromatography/pyrolysis/isotope ratio mass spectrometry (GC/pyrolysis/IRMS). These analyses were previously limited to volatile compounds. In this study, site-specific carbon isotope analysis has been developed for non-volatile aromatic carboxylic acids at sub-micromolar level by decarboxylation using a continuous flow elemental analysis (EA)/pyrolysis/IRMS technique. Benzoic acid, 2-naphthylacetic acid and 1-pyrenecarboxylic acid were pyrolyzed at 500-1000 degrees C by EA/pyrolysis/IRMS to produce CO2 for delta13C measurement of the carboxyl group. These three aromatic acids were most efficiently pyrolyzed at 750 degrees C. Conventional sealed-tube pyrolysis was also conducted for comparison. The delta13C values of CO2 generated by the continuous flow technique were within 1.0 per thousand of those performed by the conventional technique, indicating that the new continuous flow technique can accurately analyze the carbon isotopic composition of the carboxyl group in aromatic carboxylic acids. The new continuous flow technique is simple, rapid and uses small sample sizes, so this technique will be useful for characterizing the isotopic signature of carboxyl groups in organic compounds.  相似文献   

6.
In doubly labelled water studies, biological sample enrichments are mainly measured using off-line techniques (equilibration followed by dual-inlet introduction) or high-temperature elemental analysis (HT-EA), coupled with an isotope-ratio mass spectrometer (IRMS). Here another continuous-flow method, (CF-EA/IRMS), initially dedicated to water, is tested for plasma and urine analyses.The elemental analyser configuration is adapted for each stable isotope: chromium tube for deuterium reduction and glassy carbon reactor for 18O pyrolysis. Before on-line conversion of water into gas, each matrix is submitted to a short and easy treatment, which is the same for the analysis of the two isotopes. Plasma is passed through centrifugal filters. Urine is cleaned with black carbon and filtered (0.45 microm diameter).Tested between 150 and 300 ppm in these fluids, the D/H ratio response is linear with good repeatability (SD<0.2 ppm) and reproducibility (SD<0.5 ppm). For 18O/16O ratios (from 2000 to 2200 ppm), the same repeatability is obtained with a between-day precision lower than 1.4 ppm. The accuracy on biological samples is validated by comparison to classical dual-inlet methods: 18O analyses give more accurate results. The data show that enriched physiological fluids can be successfully analysed in CF-EA/IRMS.  相似文献   

7.
This paper describes the application of a simple chromium reduction furnace which can be interfaced with a dual inlet isotope-ratio mass spectrometer thus providing the capacity for cheap, fast, accurate and precise measurement of deltaD(V-SMOW) by dynamic mass spectrometry. Measurements are precise to the order of < or =0.5 per thousand. Mean 95% confidence intervals for the Vienna Standard Mean Ocean Water (V-SMOW) to Standard Light Antarctic Precipitation (SLAP) range are in the order of 2.5 per thousand and the system is linear over the range -428 to 23,000 per thousand. Memory effects do exist, but are small for natural abundance samples and can be minimised by careful planning of the analytical load.  相似文献   

8.
The doubly labelled water method is valuable for measuring energy expenditure in humans. It usually involves blood or urine sampling, which might be difficult in neonates and children with cerebral palsy or other disabilities. We therefore aimed to validate a method making use of saliva samples analyzed by automated thermal conversion elemental analyzer in combination with isotope ratio mass spectrometry (TC‐EA/IRMS). The subjects received labelled water orally and urine and saliva samples were collected and analyzed. Deuterium as well as oxygen18 was measured in one single run using a peak jump method. Excellent linearity was found for measurement of enrichments of deuterium (R2 = 0.9999) and oxygen18 (R2 = 0.9999). The intra‐assay precision and the inter‐assay precision of the measurement of two standards were good for both deuterium and oxygen18. The variation between urine and saliva samples was small (4.83% for deuterium and 2.33% for oxygen18 n = 40). Saliva sampling is to be preferred, therefore, as it can be easily collected and is non‐invasive. Moreover, its time of production is almost exactly known. The TC‐EA/IRMS method is a good alternative to the more laborious off‐line IRMS measurements. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A continuous-flow technique has been developed to analyse the deltaD and delta(13)C values for CH(4) from gas samples, in a single run. This is achieved by splitting the sample gas stream and directing the streams simultaneously through a CuNiPt combustion reactor and an alumina pyrolysis reactor. The CO(2) from CH(4) combustion is trapped in a liquid nitrogen trap while the H(2) exiting the pyrolysis reactor is directed to the mass spectrometer for deltaD(CH4) determination. The CO(2) is then sublimed and directed to the mass spectrometer for delta(13)C(CH4) determination. Sample runs take approximately 10 minutes. This technique gives accurate delta(13)C(CH4) results to within +/-0.3-0.5 per thousand and deltaD(CH4) results to within +/-2-5 per thousand. Injection volumes between 0.5 and 2.5 microL of CH(4), equivalent to between 20 and 100 nmol CH(4), are required for accurate delta(13)C and deltaD analyses, respectively, using sample injection into a split flow with a split ratio of 10. This method provides rapid, accurate and reproducible results on multiple sample runs and is, therefore, an ideal method for analysing natural gas samples from a variety of sources.  相似文献   

10.
We describe a modified version of the equilibration method and a correction algorithm for isotope ratio measurements of small quantities of water samples. The deltaD and the delta(18)O of the same water sample can both be analyzed using an automated equilibrator with sample sizes as small as 50 microL. Conventional equilibration techniques generally require water samples of several microL. That limitation is attributable mainly to changes in the isotope ratio ((18)O/(16)O or D/H) of water samples during isotopic exchange between the equilibration gas (CO(2) or H(2)) and water, and therefore the technique for microL quantities of water requires mass-balance correction using the water/gas (CO(2) or H(2)) mole ratio to correct this isotopic effect. We quantitatively evaluate factors controlling the variability of the isotopic effect due to sample size. Theoretical consideration shows that a simple linear equation corrects for the effects without determining parameters such as isotope fractionation factors and water/gas mole ratios. Precisions (1-sigma) of 50-microL meteoric water samples whose isotopic compositions of -1.4 to -396.2 per thousand for deltaD are +/-0.5 to +/-0.6 per thousand, and of -0.37 to -51.37 per thousand for delta(18)O are +/-0.01 to +/-0.11 per thousand.  相似文献   

11.
Gas chromatography/pyrolysis/isotope ratio mass spectrometry (GC/P/IRMS) is a relatively new method for on-line determination of (2)H/(1)H isotope ratios. The influence of different parameters on the (2)H/(1)H isotope ratios obtained in GC/P/IRMS has been thoroughly studied using several flavor compounds, such as 5-nonanone, linalool, menthol, linalyl acetate and 4-decanolide. The requirement of "conditioning" the pyrolysis reactor to obtain reliable delta(2)H(V-SMOW) values is discussed. Furthermore, the influence of the carrier gas flow of the gas chromatograph on the completeness of pyrolysis and subsequently on the delta(2)H(V-SMOW) values is investigated in detail. The linear range of the compounds investigated is determined. The results show that calibrating the GC/P/IRMS system with secondary standard substances is absolutely necessary in order to obtain reliable delta(2)H(V-SMOW) values. In view of interlaboratory comparability, validation procedures are recommended.  相似文献   

12.
Accurate and efficient measurement of the oxygen isotope composition of carbonates (delta(C) (18)O) based on the mass spectrometric analysis of CO(2) produced by reacting carbonate samples with H(3)PO(4) is compromised by: (1) uncertainties associated with fractionation factors (alpha(CO)(2)C) used to correct measured oxygen isotope values of CO(2)(delta(CO(2)(18)O) to delta(C) (18)O; and (2) the slow reaction rates of many carbonates of geological and environmental interest with H(3)PO(4). In contrast, determination of delta(C) (18)O from analysis of CO produced by high-temperature (>1400 degrees C) pyrolytic reduction, using an elemental analyser coupled to continuous-flow isotope-ratio mass spectrometry (TC/EA CF-IRMS), offers a potentially efficient alternative that measures the isotopic composition of total carbonate oxygen and should, therefore, theoretically be free of fractionation effects. The utility of the TC/EA CF-IRMS technique was tested by analysis of carbonates in the calcite-dolomite-magnesite solid-solution and comparing the results with delta(C) (18)O measured by conventional thermal decomposition/fluorination (TDF) on the same materials. Initial results show that CO yields are dependent on both the chemical composition of the carbonate and the specific pyrolysis conditions. Low gas yields (<100% of predicted yield) are associated with positive (>+0.2 per thousand) deviations in delta(C(TC/EA) (18)O compared with delta(C(TDF) (18)O. At a pyrolysis temperature of 1420 degrees C the difference between delta(C) (18)O measured by TC/EA CF-IRMS and TDF (Delta(C(TC/EA,TDF) (18)O) was found to be negatively correlated with gas yield (r = -0.785) and this suggests that delta(C) (18)O values (with an estimated combined standard uncertainty of +/-0.38 per thousand) could be derived by applying a yield-dependent correction. Increasing the pyrolysis temperature to 1500 degrees C also resulted in a statistically significant correlation with gas yield (r = -0.601), indicating that delta(C) (18)O values (with an estimated uncertainty of +/-0.43 per thousand) could again be corrected using a yield-dependent procedure. Despite significant uncertainty associated with TC/EA CF-IRMS analysis, the magnitude of the uncertainty is similar to that associated with the application of poorly defined values of alpha(CO)(2), (C) used to derive delta(C) (18)O from delta(CO(2) (18)O measured by the H(3)PO(4) method for most common carbonate phases. Consequently, TC/EA CF-IRMS could provide a rapid alternative for the analysis of these phases without any effective deterioration in relative accuracy, while analytical precision could be improved by increasing the number of replicate analyses for both calibration standards and samples. Although automated gas preparation techniques based on the H(3)PO(4) method (ISOCARB, Kiel device, Gas-Bench systems) have the potential to measure delta(CO)(2) (18)O efficiently for specific, slowly reacting phases (e.g. dolomite), problems associated with poorly defined alpha(CO)(2), (C) remain. The application of the Principle of Identical Treatment is not a solution to the analysis of these phases because it assumes that a single fractionation factor may be defined for each phase within a solid-solution regardless of its precise chemical composition. This assumption has yet to be tested adequately.  相似文献   

13.
A gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) method is described and validated for measurement of delta(13)C values of the acetate derivatives of urinary etiocholanolone and androsterone. The analysis was performed with only 2 mL of urine. The sample preparation consisted of deconjugation with beta-glucuronidase, solid phase extraction, and derivatization with acetic anhydride and pyridine. The within-assay precision of two quality control (QC) urine samples ranged from 0.5 to 2.1 CV%. The between-assay precision in the same QC urines ranged from 1.7 to 3.4 CV%. Administration of testosterone enanthate to a subject resulted in a 6 per thousand decrease in delta(13)C values from -25 per thousand (baseline) to -31 per thousand. Two weeks after testosterone administration was discontinued, the delta(13)C values remained abnormally low while the urine testosterone/epitestosterone (T/E) ratio returned to less than 6. This relatively simple method is useful for rapidly screening a large number of urine samples, including those with T/E <6.  相似文献   

14.
Isotope-ratio detection for gas chromatography   总被引:1,自引:0,他引:1  
Instrumentation and methods exist for highly precise analyses of the stable-isotopic composition of organic compounds separated by GC. The general approach combines a conventional GC, a chemical reaction interface, and a specialized isotope-ratio mass spectrometer (IRMS). Most existing GC hardware and methods are amenable to isotope-ratio detection. The interface continuously and quantitatively converts all organic matter, including column bleed, to a common molecular form for isotopic measurement. C and N are analyzed as CO2 and N2, respectively, derived from combustion of analytes. H and O are analyzed as H2 and CO produced by pyrolysis/reduction. IRMS instruments are optimized to provide intense, highly stable ion beams, with extremely high precision realized via a system of differential measurements in which ion currents for all major isotopologs are simultaneously monitored. Calibration to an internationally recognized scale is achieved through comparison of closely spaced sample and standard peaks. Such systems are capable of measuring 13C/12C ratios with a precision approaching 0.1 per thousand (for values reported in the standard delta notation), four orders of magnitude better than that typically achieved by conventional "organic" mass spectrometers. Detection limits to achieve this level of precision are typically < 1 nmol C (roughly 10 ng of a typical hydrocarbon) injected on-column. Achievable precision and detection limits are correspondingly higher for N, O, and H, in that order.  相似文献   

15.
A method for isotope ratio analysis of water samples is described comprising an on-line high-temperature reduction technique in a helium carrier gas. Using a gas-tight syringe, injection of 0.5 to 1 microL sample is made through a heated septum into a glassy carbon reactor at temperatures in excess of 1300 degrees C. More than 150 injections can be made per day and both isotope ratios of interest, delta2H and delta18O, can be measured with the same setup. The technique has the capability to transfer high-precision stable isotope ratio analysis of water samples from a specialized to a routine laboratory task compatible with other common techniques (automated injection for GC, LC, etc.). Experiments with an emphasis on the reactor design were made in two different laboratories using two different commercially available high-temperature elemental analyser (EA) systems.In the Jena TC/EA unit, sample-to-sample memory (single injection) has been reduced to approximately 1% and high precision of about 0.1 per thousand for delta18O and < 1 per thousand for delta2H has been achieved by a redesign of the glassy carbon reactor and by redirecting the gas flow of the commercial TC/EA unit. With the modified reactor, the contact of water vapour with surfaces other than glassy carbon is avoided completely. The carrier gas is introduced at the bottom of the reactor thereby flushing the outer tube compartment of the tube-in-tube assembly before entering the active heart of the reactor.With the Leipzig high-temperature reactor (HTP) similar precision was obtained with a minor modification (electropolishing) of the injector metal sleeve. With this system, the temperature dependence of the reaction has been studied between 1100 and 1450 degrees C. Complete yield and constant isotope ratio information has been observed only for temperatures above 1325 degrees C. For temperatures above 1300 degrees C the reactor produces an increasing amount of CO background from reaction of glass carbon with the ceramic tube. This limits the usable temperature to a maximum of 1450 degrees C. Relevant gas permeation through the Al2O3 walls has not been detected up to 1600 degrees C.  相似文献   

16.
Oxygen isotope values of biogenic apatite have long demonstrated considerable promise for paleothermometry potential because of the abundance of material in the fossil record and greater resistance of apatite to diagenesis compared to carbonate. Unfortunately, this promise has not been fully realized because of relatively poor precision of isotopic measurements, and exceedingly small size of some substrates for analysis. Building on previous work, we demonstrate that it is possible to improve precision of δ18OPO4 measurements using a ‘reverse‐plumbed’ thermal conversion elemental analyzer (TC/EA) coupled to a continuous flow isotope ratio mass spectrometer (CF‐IRMS) via a helium stream [Correction made here after initial online publication]. This modification to the flow of helium through the TC/EA, and careful location of the packing of glassy carbon fragments relative to the hot spot in the reactor, leads to narrower, more symmetrically distributed CO elution peaks with diminished tailing. In addition, we describe our apatite purification chemistry that uses nitric acid and cation exchange resin. Purification chemistry is optimized for processing small samples, minimizing isotopic fractionation of PO4?3 and permitting Ca, Sr and Nd to be eluted and purified further for the measurement of δ44Ca and 87Sr/86Sr in modern biogenic apatite and 143Nd/144Nd in fossil apatite. Our methodology yields an external precision of ± 0.15‰ (1σ) for δ18OPO4. The uncertainty is related to the preparation of the Ag3PO4 salt, conversion to CO gas in a reversed‐plumbed TC/EA, analysis of oxygen isotopes using a CF‐IRMS, and uncertainty in constructing calibration lines that convert raw δ18O data to the VSMOW scale. Matrix matching of samples and standards for the purpose of calibration to the VSMOW scale was determined to be unnecessary. Our method requires only slightly modified equipment that is widely available. This fact, and the demonstrated improvement in precision, should help to make apatite paleothermometry far more accessible to paleoclimate researchers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
Normalization of stable isotope data is important for meaningful inter-laboratory comparisons of data, especially for waters where there may be large natural variations in isotope ratios of oxygen and hydrogen. As a result, large, systematic errors may arise in continuous flow applications without correction, whereas normalization to the VSMOW/SLAP scale can facilitate inter-laboratory comparison and can be accomplished by a simple procedure in which secondary laboratory standards, carefully calibrated, are analyzed along with unknown samples. Delta values for these standards, as analyzed, are plotted against the calibrated values and a linear regression is performed. The resulting equation is applied to unknown samples to achieve the normalization. The one-sigma [1sigma] standard deviation for replicate samples by this normalization method using a Finnigan Gasbenchll should be 相似文献   

18.
An off-line technique is described for the preparation of H(2) from water prior to analysis of delta(2)H by dual-inlet isotope ratio mass spectrometry. H(2) is produced from sample water by reaction with LiAlH(4). This provides a rapid and inexpensive method for the analysis of delta(2)H in small (10 microL) samples of water. Precision was +/- 4.2 to 8.0 (1sigma(n), n = 8) delta(2)H(VSMOW) for samples between 428 and 1500 delta(2)H(VSMOW), +/- 14.5 delta(2)H(VSMOW) for water enriched to 3750 delta(2)H(VSMOW) and +/- 26.0 delta(2)H(VSMOW) for water enriched to 6100 delta(2)H(VSMOW). Accuracy was +/- 1.1 to 4.2 delta(2)H(VSMOW) for water standards from natural abundance to 1000 delta(2)H(VSMOW) (the highest enrichment at which water of accepted delta(2)H is currently available). This method for delta(2)H determination is most appropriate for use with small (<50 microL) samples of high delta(2)H enrichment such as those produced from doubly labelled water studies of small animals. The levels of measurement precision of delta(2)H would contribute 2.6-3.8% to the precision error in estimates of small animal energy expenditure made using the doubly labelled water technique when duplicate analyses are performed.  相似文献   

19.
The thermal conversion/elemental analyzer‐isotope ratio mass spectrometer (TC/EA‐IRMS) is widely used to measure the δ18O value of various substances. A premise for accurate δ18O measurement is that the oxygen in the sample can be converted into carbon monoxide (CO) quantitatively or at least proportionally. Therefore, a precise method to determine the oxygen yield of TC/EA‐IRMS measurements is needed. Most studies have used the CO peak area obtained from a known amount of a solid reference material (for example, benzoic acid) to calibrate the oxygen yield of the sample. Although it was assumed that the oxygen yield of the solid reference material is 100%, no direct evidence has been provided. As CO is the analyte gas for δ18O measurement by IRMS, in this study, we use a six‐port valve to inject CO gas into the TC/EA. The CO is carried to the IRMS by the He carrier gas and the CO peak area is measured by the IRMS. The CO peak area thus obtained from a known amount of the injected CO is used to calibrate the oxygen yield of the sample. The oxygen yields of commonly used organic and inorganic reference materials such as benzoic acid (C6H5COOH), silver phosphate (Ag3PO4), calcium carbonate (CaCO3) and silicon dioxide (SiO2) are investigated at different reactor temperatures and sample sizes. We obtained excellent linear correlation between the peak area for the injected CO and its oxygen atom amount. C6H5COOH has the highest oxygen yield, followed by Ag3PO4, CaCO3 and SiO2. The oxygen yields of TC/EA‐IRMS are less than 100% for both organic and inorganic substances, but the yields are relatively stable at the specified reactor temperature and for a given quantity of sample. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
This paper validates the use of high-temperature conversion elemental analyser isotope-ratio mass spectrometry (TC-EA/IRMS) for measuring the [(2)H/H] enrichment of plasma [(2)H(5)]cholesterol. From a molecular point of view, the free cholesterol is initially separated from plasma by thin-layer chromatography (TLC) and then injected onto the TC-EA reactor which converts cholesterol molecules into CO and H(2) gases. The slope of the curve of the experimental mole percent excess (MPE((exp.))) versus MPE((theor.)) was very close to 1, demonstrating that no significant isotopic fractionation was observed during all processing of the samples (i.e., isolation of plasma free cholesterol by TLC and pyrolysis in the TC-EA reactor). Excellent linearity (r(2) = 0.9994, n = 4) of delta ( per thousand ) of [(2)H/H] isotopic measurements versus mole percent (MP) was assessed over the range 0 to 0.1 MP. The precision of the [(2)H/H] measurement, evaluated with two calibration points processed with TLC, was delta(2)H(V-SMOW) = -192.5 +/- 3.4 per thousand and delta(2)H(V-SMOW) = -136.9 +/- 2.9 per thousand. The standard deviations of the within-assay and between-assay repeatabilities of the analytical process, evaluated using the quality control (QC) of plasma samples, were 4.6 and 6.1 per thousand, respectively. Plant sterols are known to reduce cholesterol absorption and therefore were used as a positive control in a clinical study performed with normocholesterolemic volunteers. This present method produces biological results consistent with those already reported in the literature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号