首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This paper proposes a solid-phase microextraction (SPME) method for the passive sampling and determination of N,N-dimethylacetamide (DMA) and N,N-dimethylformamide (DMF) in air by capillary GC with flame ionization detection. The optimized conditions for SPME method were grab sampling, polydimethylsiloxane/divinylbenzene fiber, extraction for 90 min at 25 +/- 2 degrees C, desorption for 3 min at 220 degrees C, and relative humidity 45 +/- 2%. Under these conditions, the method presented good linearity (R = 0.996), repeatability (%RSD 2.79 and 9.85 for DMF and DMA, respectively), and detection limit (0.021 and 0.024 mg/m3 for DMF and DMA, respectively).  相似文献   

2.
申书昌  张文治  王文波 《色谱》2002,20(3):269-271
 采用顶空气相法测定了氯乙烯生产过程产生的盐酸溶液中的乙炔和氯乙烯。使用氢氧化钠将试样中的氯化氢中和 ,从而消除其在气相分析乙炔和氯乙烯中的影响。顶空平衡温度为 35℃ ,平衡时间为 4 5min ,柱为填充了GDX 2 0 2固定相的 2m× 3mmi d 不锈钢柱 ,柱温 14 0℃。顶空气体进样量为 1mL。以外标法定量 ,乙炔含量测定结果的相对标准偏差为 0 85 % ;当其含量为 30 0 μg/g~ 15 0 μg/g时 ,回收率为 98 9%~10 3%。氯乙烯含量测定结果的相对标准偏差为 1 4 % ;当其含量为 2 0 0 μg/g~ 10 0 μg/g时 ,回收率为 98 8%~10 2 %。  相似文献   

3.
Kinetic adsorption isotherms were obtained by gravimetric determination of water adsorption into fully hydroxylated mesoporous silicas using samples exposed to controlled humidity air at 22+/-2 degrees C. Twenty kinetic isotherms at several relative humidities (11, 33, 43, 51, 75, and 85%) were obtained with 11 different batches of silica using this simple procedure to obtain quantitative information on the formation of H2O adsorbates. The H2O surface concentrations obtained from the plateau data of individual kinetic adsorption isotherms at 43 and 51% RH, typically precise to about +/-1%, show that a complete monolayer is formed with negligible second-layer adsorption at these relative humidities. This monolayer has a surface concentration of 7.68+/-0.30 micromol H2O/m2, which is lower than the quasi-equilibrium concentration at these relative humidities obtained by the conventional equilibrium-isotherm procedure. Comparison with the Kiselev-Zhuravlev concentration of silanol groups on fully hydroxylated silicas (7.6+/-0.8 micromol SiOH/m2) confirms 1:1 H2O:SiOH stoichiometry of this monolayer. The presence of partial-layer structures at 2.85+/-0.1 and 5.7+/-0.1 micromol H2O/m2 is suggested by isotherms at 11 and 33% RH, respectively, while a bilayer at approximately 14+/-1 micromol H2O/m2 is suggested by kinetic isotherms at 75 and 85% RH.  相似文献   

4.
Water-Nafion phase equilibria and proton conductivities were measured in two ways. First, Nafion was in contact with saturated water vapor. Second, Nafion was in contact with liquid water at the same temperature. At 29 degrees C, for preboiled, vapor-equilibrated Nafion exposed to water with an activity = 1 and air pressures ranging from 0 to 0.96 bar, the water content was lambda = 23 +/- 1 mol H(2)O/mol SO3-. For the preboiled, liquid-equilibrated membrane, lambda = 24 +/- 2. At 100% relative humidity (RH), the water content of preboiled Nafion decreased as the temperature rose from 30 to 80 degrees C but did not recover its initial water content when the temperature returned to 30 degrees C. The water content of predried Nafion at 1 atm and 30 degrees C was lambda = 13.7 +/- 0.2 when vapor-equilibrated and lambda = 13.1 +/- 0.5 when liquid-equilibrated. A Nafion membrane originally boiled in water had much higher liquid- and 100% RH vapor-equilibrated proton conductivities than the same membrane originally dried at 110 degrees C with a RH less than 2%. The liquid-equilibrated and 100% RH vapor-equilibrated membrane conductivities were the same when the membrane had the same thermal history. The conductivity data was fit to a model, and the water content was determined at different temperatures. The predried membrane water content increased with temperature, and the preboiled membrane's water content changed slightly with temperature. Both water sorption and proton-conductivity data do not exhibit Schroeder's paradox. These studies and previous results suggest that Schroeder's paradox is resolved when attention is given to the thermal history of the absorbing polymer.  相似文献   

5.
Adsorption of water vapour from humid air by selected carbon adsorbents   总被引:2,自引:0,他引:2  
The water uptake by carbon molecular sieves (CMS) and graphitized carbons, all of which are used to determine volatile organic compounds in air, was investigated using a direct experimental approach. CMS, e.g. Carboxen 1002, Carboxen 1003 and Anasorb CMS adsorb substantial amounts of water, in the range 400 to 450 mg per gram of adsorbent. Graphitized carbons, e.g. Carbrogaph 5TD and Carbopack X show low water trapping, less than 30 mg g(-1) and Carbopack Y as little as 5 mg g(-1) or less. The water sorption capacity for graphitized carbons is strongly dependent on the relative humidity (RH). The change of RH from 95 to 90% decreases the amount of adsorbed water by more than a factor of 2. Two different water adsorption mechanisms are operative: adsorption on polar centers and micropore volume filling. For graphitized carbons and CMS at low RH, adsorption on polar centers is involved. For CMS, once the threshold value of relative humidity (RHth) is surpassed, micropore volume filling becomes predominant. RHth is 44 +/- 3 and 42 +/- 3% for Carboxen 1002 and 1003, respectively, and 32 +/- 3% for Anasorb CMS. The CMS mass in the trap was found not to affect the mass of retained water under condition of incomplete saturation of adsorbent bed with water. Thus, the restrictions commonly imposed on the CMS mass are not necessary. The dry purging technique is suggested to remove adsorbed water. Carbograph 5TD and Carbopack X require only a few hundred ml of dry air to remove adsorbed water entirely. Water can also be purged out from CMS; however, much larger volumes of dry air are needed.  相似文献   

6.
The relative humidity (RH) of air is an important parameter that needs to be measured in many industries. Brook et al.[1,2] studied the response of Nafion films containing Crystal Violet to the relative humidity; Raimundo et al.[3] investigated the composition of Nafion-Crystal Violet films and their casting processes. In this paper, the sensing film was prepared by entrapped Crystal Violet in the commercial Nafion film. The dry air was commercially available and the 100% RH air was obtained by bubbling dry air into a series of bubbling flasks filled with deionized water. A spectrophotometer was employed to monitor the absorption changes of the film at the range of 400nm to 700 nm.  相似文献   

7.
Nalophan bags made from poly(ethylene terephtalate) film are often used to collect odorous gases. In this paper, the sample water removal method, based on humidity diffusion through the sample bag film, was applied using Nalophan bags and Tedlar bags to sample volatile organic compounds (VOCs) at low concentration (10 microg/m(3)). The removal of water with Nalophan bags enabled a reduction in relative humidity (RH) in a 10-L air sample from 80% to 20% in 2h at 20 degrees C. The use of Nalophan bags for the removal of water did not involve significant VOC loss among the 11 compounds studied.  相似文献   

8.
Water vapor can be a significant interference in the analysis of air for non-methane volatile organic compounds (NMVOCs) using solid-adsorbent sampling techniques. The adsorbent materials used in sampling cartridges have different hydrophobic characteristics, and it is therefore necessary to characterize solid-adsorbent cartridges over a wide range of humidity. Controlled humidity experiments were performed to assess the extent of water vapor interference when samples are collected onto AirToxics solid-adsorbent cartridges. It was found that elevating the temperature of the cartridge to 10 degrees C above the temperature of the air sample greatly reduced water vapor adsorption and interferences and resulted in > or = 90% recovery of NMVOCs, biogenic VOCs and chlorofluorocarbons. Similar collection efficiencies were obtained at ambient temperature by reducing the relative humidity to > or = 60% in the sample by dilution with dry, scrubbed ambient air. A procedure also was developed and optimized for dry-purging cartridges prior to analysis. However, under optimized conditions, significant losses of C3-C5 compounds still occurred under highly humid conditions. It was determined that these losses were due to reduced retention during sampling rather than loss during the dry purge procedure. The dry purge method was shown to be adequate at high humidities for sampling NMVOCs with retention indices greater than 500.  相似文献   

9.
A passive air sampler, using 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole, was evaluated for the determination of formaldehyde in indoor environments. Chromatography paper cleaned using a 3% hydrogen peroxide solution was experimentally determined as being the optimum absorption filter for the collection of formaldehyde (0.05 microg cm(-2) formaldehyde). From a linear-regression analysis between the mass of formaldehyde time-collected on a passive air sampler and the formaldehyde concentration measured by an active sampler, the sampling rate of the passive air sampler was 1.52 L h(-1). The sampling rate, determined for the passive air sampler in relation to the temperature (19 - 28 degrees C) and the relative humidity (30 - 90%), were 1.56 +/- 0.04 and 1.58 +/- 0.07 L h(-1), respectively. The relationship between the sampling rate and the air velocity was a linear-regression within the observed range. In the case of exposed samplers, the stability of the collected formaldehyde decreased with increasing storage time (decrease of ca. 25% after 22 days); but with the unexposed samplers the stability of the blank remained relatively unchanged for 7 days (decrease of ca. 37% after 22 days). The detection limits for the passive air sampler with an exposure time of 1 day and 7 days were 10.4 and 1.48 microg m(-3), respectively.  相似文献   

10.
Steger HF 《Talanta》1976,23(9):643-648
The stability of three certified reference sulphide ores, MP-1, KC-1 and SU-1, towards air oxidation has been measured at 50 degrees and 40, 62 and 82% relative humidity, and at 62% relative humidity and 34 degrees and 67 degrees . Both the relative humidity and temperature affect the rate of oxidation but their relative importance depends on the mineralogical composition of the ore. Changes in the water-extractable metals and elemental sulphur content on oxidation have been determined. It is concluded that these ores may be stored safely in sealed bottles under normal laboratory conditions.  相似文献   

11.
Combustion calorimetry studies were used to determine the standard molar enthalpies of formation of o-, m-, and p-cresols, at 298.15 K, in the condensed state as Delta(f)H(m) degrees (o-CH(3)C(6)H(4)OH,cr) = -204.2 +/- 2.7 kJ.mol(-1), Delta(f)H(m) degrees (m-CH(3)C(6)H(4)OH,l) = -196.6 +/- 2.1 kJ.mol(-1), and Delta(f)H(m) degrees (p-CH(3)C(6)H(4)OH,cr) = -202.2 +/- 3.0 kJ.mol(-1). Calvet drop calorimetric measurements led to the following enthalpy of sublimation and vaporization values at 298.15 K: Delta(sub)H(m) degrees (o-CH(3)C(6)H(4)OH) = 73.74 +/- 0.46 kJ.mol(-1), Delta(vap)H(m) degrees (m-CH(3)C(6)H(4)OH) = 64.96 +/- 0.69 kJ.mol(-1), and Delta(sub)H(m) degrees (p-CH(3)C(6)H(4)OH) = 73.13 +/- 0.56 kJ.mol(-1). From the obtained Delta(f)H(m) degrees (l/cr) and Delta(vap)H(m) degrees /Delta(sub)H(m) degrees values, it was possible to derive Delta(f)H(m) degrees (o-CH(3)C(6)H(4)OH,g) = -130.5 +/- 2.7 kJ.mol(-1), Delta(f)H(m) degrees (m-CH(3)C(6)H(4)OH,g) = -131.6 +/- 2.2 kJ.mol(-1), and Delta(f)H(m) degrees (p-CH(3)C(6)H(4)OH,g) = -129.1 +/- 3.1 kJ.mol(-1). These values, together with the enthalpies of isodesmic and isogyric gas-phase reactions predicted by the B3LYP/cc-pVDZ, B3LYP/cc-pVTZ, B3P86/cc-pVDZ, B3P86/cc-pVTZ, MPW1PW91/cc-pVTZ, CBS-QB3, and CCSD/cc-pVDZ//B3LYP/cc-pVTZ methods, were used to obtain the differences between the enthalpy of formation of the phenoxyl radical and the enthalpies of formation of the three methylphenoxyl radicals: Delta(f)H(m) degrees (C(6)H(5)O*,g) - Delta(f)H(m) degrees (o-CH(3)C(6)H(4)O*,g) = 42.2 +/- 2.8 kJ.mol(-1), Delta(f)H(m) degrees (C(6)H(5)O*,g) - Delta(f)H(m) degrees (m-CH(3)C(6)H(4)O*,g) = 36.1 +/- 2.4 kJ.mol(-1), and Delta(f)H(m) degrees (C(6)H(5)O*,g) - Delta(f)H(m) degrees (p-CH(3)C(6)H(4)O*,g) = 38.6 +/- 3.2 kJ.mol(-1). The corresponding differences in O-H bond dissociation enthalpies were also derived as DH degrees (C(6)H(5)O-H) - DH degrees (o-CH(3)C(6)H(4)O-H) = 8.1 +/- 4.0 kJ.mol(-1), DH degrees (C(6)H(5)O-H) - DH degrees (m-CH(3)C(6)H(4)O-H) = 0.9 +/- 3.4 kJ.mol(-1), and DH degrees (C(6)H(5)O-H) - DH degrees (p-CH(3)C(6)H(4)O-H) = 5.9 +/- 4.5 kJ.mol(-1). Based on the differences in Gibbs energies of formation obtained from the enthalpic data mentioned above and from published or calculated entropy values, it is concluded that the relative stability of the cresols varies according to p-cresol < m-cresol < o-cresol, and that of the radicals follows the trend m-methylphenoxyl < p-methylphenoxyl < o-methylphenoxyl. It is also found that these tendencies are enthalpically controlled.  相似文献   

12.
The HO2 uptake coefficient (gamma) for inorganic submicrometer wet and dry aerosol particles ((NH4)2SO4 and NaCl) under ambient conditions (760 Torr and 296 +/- 2 K) was measured using an aerosol flow tube (AFT) coupled with a chemical conversion/laser-induced fluorescence (CC/LIF) technique. The CC/LIF technique enabled experiments to be performed at almost the same HO2 radical concentration as that in the atmosphere. HO2 radicals were injected into the AFT through a vertically movable Pyrex tube. Injector position-dependent profiles of LIF intensity were measured as a function of aerosol concentration. Measured gamma values for dry aerosols of (NH4)2SO4 were 0.04 +/- 0.02 and 0.05 +/- 0.02 at 20% and 45% relative humidity (RH), respectively, while those of NaCl were <0.01 and 0.02 +/- 0.01 at 20% and 53% RH, respectively. For wet (NH4)2SO4 aerosols, measured gamma values were 0.11 +/- 0.03, 0.15 +/- 0.03, 0.17 +/- 0.04, and 0.19 +/- 0.04, at 45%, 55%, 65%, and 75% RH, respectively, whereas for wet NaCl aerosols the values were 0.11 +/- 0.03, 0.09 +/- 0.02, and 0.10 +/- 0.02 for 53%, 63%, and 75% RH, respectively. Wet (NH4)2SO4 and NaCl aerosols doped with CuSO4 showed gamma values of 0.53 +/- 0.12 and 0.65 +/- 0.17, respectively. These results suggest that compositions, RH, and phase for aerosol particles are significant to HO2 uptake. Potential HO2 loss processes and their atmospheric contributions are discussed.  相似文献   

13.
Atmospheric humidity causes the major problem using ion mobility spectrometers (IMS) under ambient conditions. Significant changes of the spectra are decreasing sensitivity as well as selectivity. Therefore, the influence of humidity on the IMS signal was investigated in case of direct introduction of the analyte into the ionisation chamber and in case of pre-separation by help of a multi-capillary column (MCC). For direct analyte introduction, a significant decrease of the total number of ions in the range of 28-42% with increasing relative humidity was found. Simultaneously additional peaks in the spectra were formed, thus complicating the identification of the analytes. In case of pre-separation of the analyte, the spectra do not change with increasing relative humidity, due to the successive appearance of the analyte and the water molecules in the ionisation chamber. Detection limits were found in the range of 5 μg/m3 (about 1 ppbv) for selected terpenes and—with pre-separation—independent on relative humidity of the analyte. Without pre-separation, detection limits are in the same range for dry air as carrier gas but in the range of 200-600 μg/m3 when relative humidity reaches 100%. Thus, MCC-UV ion mobility spectrometry is optimally capable for the detection of trace substances in ambient air (e.g. indoor air quality control, process control, odour detection) without further elaborate treatment of the carrier gas containing the analyte and independent on relative humidity.  相似文献   

14.
Two methods for the determination of hexahydrophthalic anhydride (HHPA) in air were developed. In a solid sorbent method, HHPA was sampled in Amberlite XAD-2 tubes, eluted in toluene and analysed by gas chromatography with flame ionization detection. The sampling rates were 0.2 and 1.0 l/min. At 15 micrograms/m3 (relative humidity less than 2%) and 27 micrograms/m3 (relative humidity 70%) no breakthrough was observed. However, at 160 micrograms/m3 (relative humidity less than 2%), 6% breakthrough was found. The sampling efficiency of the sampling rates 0.2 and 1.0 l/min did not differ. In a bubbler method, HHPA was sampled in bubblers filled with 0.1 M sodium hydroxide solution. The sodium salt of hexahydrophthalic acid was formed. No breakthrough was observed using a sampling rate of 1.0 l/min. The samples were stable during storage for eight weeks in a refrigerator. The HHP acid was esterified with methanol-boron trifluoride and analysed by gas chromatography-flame ionization detection. Apparatus for the generation of standard atmospheres of HHPA, in the range of 10-3000 micrograms/m3, was developed using the diffusion principle. For the solid sorbent method the precision (coefficient of variation) of the overall method was 2-7%, and for the bubbler method 3-19% (range 15-160 micrograms HHPA/m3; relative humidity = less than 2-70%). A comparison between the two methods was performed using the standard atmosphere. The concentrations found by the solid sorbent method were 86-98% of those found by the bubbler method (range 15-160 micrograms HHPA per m3; relative humidity = less than 2-70%). In work environment air, 93% was found using the solid sorbent method relative to the bubbler method at a mean concentration of 330 micrograms/m3 (coefficient of variation = 39%; range 200-540 micrograms/m3). For both methods, concentrations greater than 3 micrograms/m3 could be quantified at 60 min sampling with a sampling rate of 1.0 l/min.  相似文献   

15.
A new standard for the calibration of refractometers has been developed. Standard Reference Material (SRM) 1922 is a mineral oil with a refractive index nD = 1.46945 at 20 degrees C, which is within the range of the Brix scale (% sucrose). The change in refractive index with temperature (dn/dT) has been characterized for the range 15 degrees C to 35 degrees C to allow for calibrations within that range of temperatures. The refractive indices were measured at 5 wavelengths in the visible spectrum by using the method of minimum deviation with a +/- 2-3 x 10(-5) uncertainty at 20 degrees C. The values of nD and dnD/dT were determined by fits of a two-term Cauchy function to the values at the measured wavelengths with a +/- 6 x 10(-5) uncertainty in nD at 20 degrees C.  相似文献   

16.
Twenty-three laboratories participated in a collaborative study to compare the relative effectiveness of Rappaport-Vassiliadis (RV) medium incubated at 42 degrees C, selenite cystine (SC) broth (35 degrees C), and tetrathionate (TT) broth (35 and 43 degrees C) for recovery of Salmonella from the following foods with a low microbial load: dried egg yolk, dry active yeast, ground black pepper, guar gum, and instant nonfat dry milk. For dry active yeast, lauryl tryptose (LT) broth, incubated at 35 degrees C, was used instead of SC broth. All of the foods were artificially inoculated with single Salmonella serovars, that had been lyophilized before inoculation, at high and low target levels of 0.4 and 0.04 colony forming units/g food, respectively. For analysis of 870 test portions, representing all of the foods except yeast, 249 Salmonella-positive test portions were detected by RV medium, 265 by TT broth (43 degrees C), 268 by TT broth (35 degrees C), and 269 by SC broth (35 degrees C). For analysis of 225 test portions of yeast, 79 Salmonella-positive test portions were detected by RV medium, 79 by TT broth (43 degrees C), 84 by TT broth (35 degrees C), and 68 by LT broth (35 degrees C). RV medium was comparable to, or even more effective than, the other selective enrichments for recovery of Salmonella from all of the foods except guar gum. It is recommended that RV (42 degrees C) and TT (35 degrees C) be used with foods that have a low microbial load, except for guar gum for which SC (35 degrees C) and TT (35 degrees C) are recommended.  相似文献   

17.
Coenzyme Q10 (CoQ10), a highly lipophilic compound present in the inner mitochondrial membrane, is essential for production of cellular energy in the form of ATP. CoQ10 is used as an antioxidant and also in the treatment of various cardiovascular disorders. The relative bioavailabilities of powder filled capsule (I) and oil-based formulation (II) of CoQ10 were compared in beagle dogs in an open, randomized, multiple dose, cross-over design. Poor and slow absorption characteristics were observed for both the formulations. The AUC, Cmax, and Tmax for formulation I and II are comparable (p < 0.05) where the values for formulation I are 22.84 +/- 6.3 micrograms ml-1 h, 0.51 +/- 0.11 microgram/ml, and 6.1 +/- 2.0 h whereas the values for formulation II are 24.32 +/- 5.6 micrograms ml-1 h, 0.55 +/- 0.16 microgram/ml, and 6.6 +/- 2.3 h, respectively. Stability of CoQ10 at various temperature and humidity conditions and its photostability were studied. Various antioxidants were evaluated to determine the type and amount of antioxidant(s) required to improve the stability of CoQ10. Large extent of degradation was observed at 45 degrees C and 55 degrees C. The effect of humidity conditions on degradation was insignificant. Among the various antioxidants studied, mixture of ascorbic acid (5%) and EDTA (0.1%) offered better protection than phenolic antioxidants such as butylated hydroxy anisole (BHA), butylated hydroxy toluene (BHT), or propyl gallate (PG). Further, increasing concentrations of phenolic antioxidants (from 0.1 to 0.3%) accelerated the degradation.  相似文献   

18.
This paper presents a method of implementation and the results of aerosol dispersion tests in underground mine workings. Numerous tests were carried out to determine the potential risk of SARS-CoV-2 coronavirus infection in the underground environment of the mines. The influence of selected parameters of mine air on the possibility and method of aerosol transmission through ventilation routes was experimentally determined in real conditions. The concentration of additional aerosols in the class of ultrafine and fine aerosols increased with the distance from the generator, while the concentration of coarse particles decreased. Assuming the consumption of the solution with which aerosols were generated, even at a small level of 1 cm3/min., the number of additional aerosols was several hundred particles in one cubic centimeter of air at a distance of 50–70 m from the generator. The concentration of ultrafine particles in the range of 40–20,000 nm increased from 122 particles/cm3 to 209 particles/cm3 at air temperature of 12 °C and relative humidity of 95–96%, and from 90 particles/cm3 to 243 particles/cm3 at air temperature of 17 °C and relative humidity of 76–82%, with the increasing distance from the generator (10 m to 50 m).  相似文献   

19.
Vibrational sum frequency generation (SFG) spectroscopy was applied to study the phase transitions of the mixed monolayers of l-alpha-distearoyl phosphatidylethanolamine (DSPE) and DSPE covalently coupled with poly(ethylene oxide) at the amino head group (DSPE-EO(45), DSPE with 45 ethylene oxide monomers) at the air-water interface. The SFG spectra were measured for the mixed monolayers with the mole fractions of DSPE-EO(45) of 0, 1.3, 4.5, 9.0, 12.5, and 16.7% at the surface pressures of 5, 15, and 35 mN/m. The monolayer compression isotherms indicated that the mixed monolayers at 5, 15, are 35 mN/m are mainly in the so-called "pancake", "mushroom", and "brush" states, respectively. The SFG spectra in the OH stretching vibration region give rise to SFG bands near 3200 and 3400 cm(-1). The mean molecular amplitude of the former band due to the OH stretching of the "icelike" water molecules associated mainly with the hydrophilic poly(ethylene oxide) (PEO) chains, exhibits appreciable decrease on compression of the mixed monolayers from 5 to 15 mN/m. The result corroborates the model for the pancake-mushroom transition, which presumes the dissolution of the PEO chains from the air-water interface to the water subphase. Further compression of the mixed monolayers to 35 mN/m causes a slight decrease of the line amplitude, which can be explained by considering a squeezing out of water molecules from the hydrophilic groups of DSPE-EO(45) in the brush state, where the PEO chains strongly interact with each other to form a tight binding state of the hydrophilic groups. The relative intensities of the SFG bands due to the CH3 asymmetric and symmetric vibrations were used to estimate the tilt angles of the terminal methyl group of DSPE, indicating that the angle increases with increasing the mole fraction of DSPE-EO(45). The angles almost saturate at the mole fraction larger than 10%, the saturation angle being nearly 90 degrees at 5 mN/m, ca. 60 degrees at 15 mN/m, and ca. 47 degrees at 35 mN/ m. Then, the introduction of the hydrophilic PEO head group causes a large tilting of the alkyl groups of DEPE in the mixed monolayers.  相似文献   

20.
Leather samples were prepared and characterized as 'in house' matrix standards for the determination of fat. The Soxhlet standard method was used to establish the reference fat content in every standard sample. Sample homogeneity and stability were examined under specific storing conditions. The materials were subsequently used as matrix standards for the determination of fat in leather samples, using supercritical fluid extraction (SFE) with on-line piezoelectric detection. Real samples were weighed in the extraction SFE thimble, previously loaded with 1 g of diatomaceous earth. A temperature of 45 degrees C and a CO2 fluid density of 0.85 g ml-1 were used for extraction. The linear calibration range thus achieved was 0.001-0.040% m/m total fat (related to the weight of the leather) and the relative standard deviation +/- 3% (n = 11; P = 0.05). The results were compared with those obtained with the Soxhlet method and no significant differences were found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号