首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The potential of electrospray ionization quadrupole-quadrupole-time-of-flight mass spectrometry (ESI-QqTOF-MS) for the characterization of synthetic nucleic acids was evaluated. Oligonucleotides ranging in size from 12 up to 51 nucleotides were analyzed via direct infusion MS as well as via liquid chromatography (LC) online hyphenated to MS. These experiments proved the outstanding mass spectrometric performance of the TOF mass analyzer in regard of accuracy, reproducibility, resolution, and sensitivity. During a 1-min run, the monoisotopic mass of (dT)(24) was measured with a maximum relative mass deviation of 7.64 ppm proving the high mass accuracy of the TOF analyzer. Over a period of 1 h, mean deviations were determined in the range between -3.58 ppm and 3.06 ppm demonstrating the high stability of the applied external calibration. The molecular mass of a 51-mer was measured with a deviation smaller than 3.23 ppm from the theoretical value. The resolution exceeded a value of m/Deltam = 20 000 (m is the measured mass and Deltam the full peak width at half-maximum), which enabled the separation of the isotopic peaks of all investigated oligonucleotides. Because of the outstanding transmission and detection efficiency of the TOF mass analyzer, detection limits in the amol/microl to low fmol/microl range were reached. The usability of LC-ESI-QqTOF-MS for the qualitative and quantitative analysis of synthetic oligonucleotide mixtures was demonstrated.  相似文献   

2.
The utility of liquid chromatography combined with time-of-flight mass spectrometry (LC/TOFMS) was demonstrated for studies on chiral unsaturated epoxy compounds, sex pheromones produced mainly by female moths in the family Geometridae. By electrospray ionization (ESI), each synthetic epoxyalkadiene derived from (Z,Z,Z)-3,6,9-triene with a C(18)-C(23) straight chain showed three ion series, [M + NH(4)](+), [M + H](+) and [M - OH](+), with high resolution and good sensitivity, indicating its molecular formula. In addition to these, characteristic fragment ions at m/z M - 57 and M - 71 for the 3,4-epoxides and at m/z M - 123 and 123 for the 9,10-epoxides were detected, whereas the 6,7-epoxides did not produce fragment ions that reflected their structures. Monitoring these diagnostic ions during the LC/MS analysis of a gland extract, the natural sex pheromone of the mulberry looper was confirmed to be (Z,Z)-cis-9,10-epoxy-3,6-octadecadiene, which was separable from the other positional isomers on an ODS column. Furthermore, (Z,Z)-cis-3,4-epoxy-6,9-nonadecadiene secreted by the Japanese giant looper was analyzed with a chiral column, and the stereochemistry was determined directly.  相似文献   

3.
An electrospray ionisation (ESI) mass spectrometric method for the determination of the equilibrium constant and free energy (DeltaG) of protein unfolding was used to monitor the denaturation process at different pH of three metallo-proteins, i.e. wild-type copper azurin, zinc azurin and wild-type amicyanin. The time course of the unfolding process was followed by dissolving the proteins under denaturing conditions (methanol-water (1 : 1, v/v)) at different pH (2.5, 3.0, 3.5) and recording ESI spectra at time intervals. The spectra showed two series of peaks, corresponding to the native holo-protein and the unfolded apo-protein. From the intensity ratio of these two series of peaks at increasing time and at equilibrium, the equilibrium constants for the unfolding process for the three proteins could be determined. From these equilibrium constants a DeltaG degrees derivation was attempted. The DeltaG degrees values obtained decrease with decrease in pH, in agreement with the expected reduction of conformational stability of proteins at lower pH. The results obtained confirm that ESI-MS can be used for monitoring of unfolding process and to derive quantitative thermodynamic data.  相似文献   

4.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

5.
Interaction of carboplatin with cytochrome c (Cyt. c) has been investigated by electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS). ESI-MS studies revealed that the ring-opened adducts of carboplatin with Cyt. c were formed in the stoichiometric ratio of 1:1 and 2:1 at pH 5.0 and 37 degrees C and in the stoichiometric ratio of 1:1 only at pH 7.0 and 37 degrees C. It was also found that Cyt. c could be cleaved by carboplatin at pH 2.5 and 50 degrees C. The cleaved fragments of Cyt. c were determined by ESI-MS and MS/MS analysis to be Glu66 approximately Met80, Ac-Gly01 approximately Met65, Glu66 approximately Glu104, Ac-Gly01 approximately Met80 and Ile81 approximately Glu104. The carboplatin prefers to anchor to Met65 first, then to Met80. To further confirm the binding site of Met, AcMet-Gly was used as the model molecule to investigate its interaction with carboplatin and its hydrolysis reaction. On the basis of species detected during the reaction monitored by ESI-MS, a possible pathway of the cleavage reaction was proposed.  相似文献   

6.
The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I–IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H]+ or [M + H–nH2O]+ in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05–20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05–1, 2–5 and 10–20 ng/mL, respectively. Steroids including the conjugated keto‐functional group at C3 showed good proton affinity and stability, and generated the [M + H]+ ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H]+ ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H ? H2O]+ or [M + H ? 2H2O]+ ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC‐MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I–V) in human urine. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
This paper reports notable observations regarding the ion charge states of thermally stable cytochrome c, generated using an alternating current (AC) electrospray ionization (ESI) device. An AC ESI sprayer entrains low-mobility ions to accumulate at the meniscus cone tip prior to the ejection of detached aerosols to produce analyte ions. Therefore, as the solvent acidity varies, protein ions entrained in the AC cone tip are found to change conformation less significantly compared with those in the direct current (DC) cone. We acquired the AC ESI mass spectra of cytochrome c at pH range from 2 to 4. Unlike the DC ESI mass spectra showing clear conformation changes due to denaturing, the AC spectra indicated that only partial denaturing occurs even at extremely acidic pH 2. More native cytochrome c in lower charge states therefore remained. Moreover, with a solvent mixture of aqueous buffer and acetonitrile (70:30), partially denatured cytochrome c was still preserved at pH 2 by using AC ESI. Completely denatured proteins are observed at pH 2 by using DC ESI.  相似文献   

8.
A mass spectrometric-based procedure for anthocyanin profiling was set up to distinguish authentic Vitis vinifera from hybrid red grapevine cultivars. 3-O-Monoglucoside and the related acetyl-, p-coumaryl- and caffeoyl-monoglucoside anthocyanins occurred only in Vitis vinifera, whereas 3,5-O-diglucoside and the substituted acetyl-, p-coumaryl-, feruloyl- and caffeoyl-diglucoside anthocyanins were the additional pigments in hybrid grapevines. The procedure was applied expressly to identify red grape cultivars based on the anthocyanin chemo-type determination. In particular, a red grape cultivar, having 3,5-O-diglucoside anthocyanins and a novel class of anthocyanin monoglucosides, such as cyanidin-3-O-, cyanidin-3-O-(6-O-acetyl)- and cyanidin-3-O-(6-O-p-coumaryl)pentoside, was classified as hybrid. A second vine cultivar, characterized exclusively by 3-O-monoglucoside anthocyanins, was included among the Vitis vinifera species. Anthocyanin profiling by mass spectrometry could represent the core of a chemotaxonomic procedure for distinguishing American and European grapevines based on the identification of post-synthetic anthocyanidin modification.  相似文献   

9.
Two model peptides, des-Arg1-bradykinin (DAB) and bradykinin (B), were cationized by Ag+ after their separation by reversed-phase liquid chromatography (RPLC) prior to mass spectrometry (MS). Silver nitrate solution was used as a post-column reagent. The RPLC and MS experimental conditions were optimized using flow injection in order to obtain sufficiently abundant silver adducts to permit MS/MS experiments. The use of water-methanol with 0.1% formic acid as mobile phase allowed a good chromatographic separation of the two peptides with a polymeric stationary phase and sufficiently abundant silver-containing adducts, [M + Ag + H]2+ and [M + 2Ag]2+. The gas-phase dissociation of [DAB + Ag + H]2+ and [DAB + 2Ag]2+ led to interpretable mass spectra during the on-line cationization experiment. Most of the ions obtained by dissociating [DAB + Ag + H]2+ and [DAB + 2Ag]2+ species are silver-containing ions but the ions produced depend on the parent. The ions coming from the dissociation of the doubly charged silver adducts [DAB + Ag + H]2+ or [DAB + 2Ag]2+ are of interest compared with those coming from the singly charged silver species or doubly charged protonated species. The fragmentation of the doubly charged silver adducts provides ions over the entire mass range. Although the presence of several prolines in des-Arg1-bradykinin prevents the formation of some expected ions, the observation of triplets [an-H + Ag]+, [bn-H + Ag]+ and [bn + OH + Ag]+ produced by the dissociation of on-line Ag(+)-cationized peptides could contribute to greater success of automatic sequencing of peptides.  相似文献   

10.
In this study, rapid quantitative detection of histamine in beer was achieved by using nano extractive electrospray ionization mass spectrometry (nano EESI‐MS) coupling with standard addition method. Based on the MS2 experiment, histamine concentrations in three beer samples were determined to be 1.10 ± 0.12 µg/ml, 0.81 ± 0.09 µg/ml and 0.79 ± 0.09 µg/ml. The limit of detection for this method was calculated to be 0.02 µg/ml. These results show that this novel method can be used for direct, rapid and sensitive detection of histamine in beer without any tedious sample pretreatment. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Novel methods for the determination of inorganic oxyanions by electrospray (ES) ionization mass spectrometry have been developed using dehydration reactions between oxyanions and carboxylic acids at the ES interface. Twelve oxyanions (VO3?, CrO42?, MoO42?, WO42?, BO33?, SiO32?, SiO44?, AsO44?, AsO2?, SeO42?, SeO32? and NO2?), out of 16 tested, reacted with at least one of four aminopolycarboxylic acids, i.e. iminodiacetic acid (IDA), nitrilotriacetic acid (NTA), trans‐1,2‐diaminocyclohexane‐N,N,N′,N′‐tetraacetic acid and triethylenetetramine‐N,N,N′,N″,N′″,N′″‐hexaacetic acid, at the ES interface to produce the dehydration products that gave intense mass ion responses, sufficient for trace analysis. As examples, trace determinations of CrVI and silica in water samples were achieved after online ion exchange chromatography, where the dehydration product of CrO42? and NTA (m/z 290) and that of SiO44? and IDA (m/z 192) were measured. The limits of detection of the respective methods were 17 nM (0.83 ng Cr/ml) for CrVI and 0.17 μM (4.8 ng Si/mL) for SiO44?. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
Structural studies of the high molecular mass (HMM) glutenin subunits 1Bx7 (from cvs Hereward and Galatea) and 1Bx20 (from cv. Bidi17) of bread wheat were conducted using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry (RP-HPLC/ESI-MS). For all three proteins, MALDI-TOFMS analysis showed that the isolated fractions contained a second component with a mass about 650 Da lower than the major component. The testing and correction of the gene-derived amino acid sequences of the three proteins were performed by direct MALDI-TOFMS analysis of their tryptic peptide mixture. Analysis of the digest was performed by recording several MALDI mass spectra of the mixture at low, medium and high mass ranges, optimizing the matrix and the acquisition parameters for each mass range. Complementary data were obtained by RP-HPLC/ESI-MS analysis of the tryptic digest. This resulted in coverage of about 98% of the sequences. In contrast to the gene-derived data, the results obtained demonstrate the insertion of the sequence QPGQGQ between Trp716 and Gln717 of subunit 1Bx7 (cv. Galatea) and a possible single amino acid substitution within the T20 peptide of subunit 1Bx20. Moreover, the mass spectrometric data demonstrated that the lower mass components present in all the fractions correspond to the major components but lack about six amino acid residues, which are probably lost from the protein C-terminus. Finally, the results obtained provide evidence for the lack of glycosylation or other post-translational modifications of these subunits.  相似文献   

13.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

14.
The reactions of ethyl pyruvate with acetic anhydride and pyridine were studied by electrospray ionization mass spectrometry (ESI-MS). Ethyl 2-acetoxy-2-pyridiniumpropionate (1) (m/z 238) resulting from the reaction of the acetylpyridinium cation with ethyl pyruvate, and the adduct of ethyl 2-acetoxyacrylate with a pyridinium cation (2), bound together by non-covalent interactions (m/z 238), were identified by ESI-MS for the first time. Structures 1 and 2 cannot be distinguished, probably because one may be converted into the other and vice versa.  相似文献   

15.
16.
Disulfide polymers obtained by ring‐opening polymerization have been considered to have a possibility of a cyclic catenane structure as judged from their test properties on the loss modulus and stress–strain. Electrospray ionization mass spectrometry (ESI‐MS) was used to detemine molecular structure of polydithiane and polyoxyethylene to find whether they are present as a cyclic or as a linear structure. The results indicated that the polydithiane possesses the cyclic structure, and analysis of the isotope distribution of the spectral ions further showed that the polymer consists entirely of the cyclic structure without contamination of a linear polymer. A linear chain polymer with a benzylmercaptan end group was synthesized, and the ESI‐MS analysis revealed that the polymer was a mixture of both the cyclic and the linear polymer. The cyclic polymer is probably formed by back‐biting of the highly reactive sulfur radicals that had been formed during the polymerization reaction. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 4403–4406, 2000  相似文献   

17.
Sangoi MS  Todeschini V  Steppe M 《Talanta》2011,84(4):905-1079
In the present study, a rapid validated stability-indicating LC method was established and comprehensive stress testing of fesoterodine was carried out according to ICH guidelines. Fesoterodine was subjected to stress conditions of acid and basic hydrolysis, oxidation, photolysis and thermal decomposition. The degradation products formed under stress conditions were investigated by LC-UV and LC-ESI-MS. Successful separation of the drug from its degradation products was achieved on a monolithic C18 column (100 mm × 4.6 mm i.d.) maintained at 45 °C using acetonitrile-methanol-0.03 mol L−1 ammonium acetate (pH 3.8) (30:15:55, v/v/v) as the mobile phase. The flow rate was 2.4 mL min−1 and the detection wavelength was 208 nm. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated. Chromatographic separation was obtained within 2.5 min and it was suitable for high-throughput analysis. Fragmentation patterns of degradation products formed under different stress conditions were studied and characterized through LC-ESI-MS fragmentation. Based on the results, a drug degradation pathway was proposed, and the validated LC method was successfully applied to the quantitative analysis of fesoterodine in tablet dosage forms, helping to improve quality control and to assure therapeutic efficacy.  相似文献   

18.
A novel, sensitive and specific method for the quantitative determination of ivermectin B(1a) in animal plasma using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is presented. Abamectin was used as the internal standard. Extraction of the samples was performed with a deproteinization step using acetonitrile. Chromatographic separation was achieved on a Nucleosil ODS 5 microm column, using gradient elution with 0.2% (v/v) acetic acid in water and 0.2% (v/v) acetic acid in acetonitrile. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1 and 100 ng ml(-1) showed a good linear correlation (r > or = 0.9989, goodness-of-fit coefficient < or =8.1%). The trueness at 2 and 25 ng ml(-1) (n = 6) was +4.2 and -17.1%, respectively. The trueness and between-run precision for the analysis of quality control samples at 25 ng ml(-1) was -4.0 and 11.0%, respectively (n = 16). The limit of quantification of the method was 1.0 ng ml(-1), for which the trueness and precision also fell within acceptable limits. Using a signal-to-noise ratio of 3 : 1, the limit of detection was calculated to be 0.2 ng ml(-1). The specificity was demonstrated with respect to ivermectin B(1b).The method was successfully used for the quantitative determination of ivermectin B(1a) in plasma samples from treated bovines, demonstrating the usefulness of the developed method for application in the field of pharmacokinetics.  相似文献   

19.
A sensitive high‐performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for measuring vinorelbine was developed. A 100 µL aliquot of plasma was spiked with deuterium‐labeled internal standard and subjected to solid‐phase extraction using an Oasis HLB μ‐elution plate. Two microliters of the extracted samples was directly injected into LC/MS/MS. Chromatographic separation was achieved on a Capcell Pak C18 UG column (2 × 75 mm) with a gradient elution of methanol (mobile phase B) against 0.05% formic acid in aqueous 10 mm ammonium formate (mobile phase A). The LC flow rate was set to 0.28 mL/min and the gradient (solvent B concentration) was processed from 40 to 90%. In mass spectrometric detection, observation of the reaction from a double‐charged precursor ion [M + 2H]2+ (m/z 390) to product ion m/z 122 provided very high sensitivity. The method was validated with a lower limit of detection of 0.2 ng/mL with 0.1 mL of plasma, and the method was used to determine the plasma pharmacokinetics of vinorelbine in dogs. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号